Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance assessment of 3D printed multi-material energy absorber for automotive bumper: pedestrian lower extremity protection

Designing an energy absorber for automotive bumpers involves balancing low-speed and high-speed impacts to ensure safety, reduce repair costs, and meet regulatory standards. Here, this study explores a novel design using multi-material 3D printing and structural optimization to fabricate a lightweight and cost-efficient energy absorber. The design effectively dissipates energy in low-speed collisions and minimizes force transmission in high-speed pedestrain impacts, helping to meet both safety and performance requirements. The energy absorber design combines 20% carbon fiber-reinforced acrylonitrile butadiene styrene (CF-ABS) and thermoplastic polyurethane (TPU) for optimal stiffness and flexibility. It uses 3D-printed lattice structures optimized through finite element simulations to help meet both low-speed and high-speed impact requirements. Full-scale energy absorbers were 3D-printed using optimized CF-ABS/TPU blends and tested under high-speed impact using the Flexible Pedestrian Legform Impactor (Flex-PLI). For fair comparison, a baseline bumper with a traditional triangular lattice structure, also 3D-printed from the same CF-ABS/TPU materials, was similarly tested. Interestingly, both the optimized and baseline 3D-printed energy absorbers showed nearly identical performance, successfully meeting injury limits. Their performances were also benchmarked against an injection-molded energy absorber. While both 3D-printed and injection-molded designs met injury limits, the 3D-printed absorber exhibited a higher tibia bending moment, indicating an opportunity for further optimization. A Techno-Economic Analysis compared the costs of producing energy absorbers using traditional manufacturing and 3D printing. The analysis highlighted that 3D printing offers cost benefits for low to medium production volumes, with the total cost per energy absorber at ∼ $\$$74, compared to traditional methods that become economical beyond 2000 units.

Additive manufacturing↗

The role of bioenergy in a climate-changing world

Bioenergy has been under intense scrutiny over the last ten years with significant research efforts in many countries taking place to define and measure sustainable practices. We describe here the main challenges and policy issues and provide policy recommendations for scaling up sustainable bioenergy approaches globally. The 2016 Intended Nationally Determined Contributions (INDCs defined under the UN Framework Convention on Climate Change) (UNFCCC) Conference of the Parties (COP21) will not reach global Greenhouse Gas (GHG) emission targets of 2 °C. Sustainable biomass production can make a significant contribution. Substantive evidence exists that many bioenergy cropping systems can bring multiple benefits and off-set environmental problems associated with fossil fuels usage as well as intensive food production and urbanization. We provide evidence that there are many approaches to land use for bioenergy expansion that do not lead to competition for food or other needs. We should focus on how to manage these approaches on a synergistic basis and how to reduce tradeoffs at landscape scales. Priorities include successful synergies between bioenergy and food security (integrated resource management designed to improve both food security and access to bioenergy), investments in technology, rural extension, and innovations that build capacity and infrastructure, promotion of stable prices to incentivize local production and use of double cropping and flex crops (plants grown for both food and non-food markets) that provide food and energy as well as other services. The sustainable production of biomass requires appropriate policies to secure long-term support to improve crop productivity and also to ensure environmental as well as economic and social benefits of bioenergy cropping systems. Continuous support for cropping, infrastructure, agricultural management and related policies is needed to foster positive synergies between food crops and bioenergy production. In comparison to fossil fuels, biofuels have many positive environmental benefits. Potential negative effects caused by land-use change and agriculture intensification can be mitigated by agroecological zoning, best management practices, the use of eco-hydrology and biodiversity-friendly concepts at field, watershed and landscape scales. Global climate and environmental changes related to the use of fossil fuels and inequitable development make it unethical not to pursue more equitable energy development that includes bioenergy. Here, to achieve sustainable development, competitiveness and costs of bioenergy production need to be addressed in a manner that considers not only economic gains but also development of local knowledge and social and environmental benefits.

09 BIOMASS FUELS↗

High-pressure ignition delay time measurements of a four-component gasoline surrogate and its high-level blends with ethanol and methyl acetate

Ignition delay times of a gasoline surrogate (iso-octane/toluene/n-heptane/1-hexene at 55/25/15/5% by liquid volume, developed in McCormick et al. 2017) with high-level bioblendstock-gasoline surrogate blends (50% and 85% biofuel by liquid volume of each ethanol and methyl acetate) were collected behind reflected shock waves. Post-reflected-shock temperatures ranged from 968 to 1361 K at pressures of about 4, 10, 25, and 50 atm. Data were collected for real fuel–air mixtures at fuel lean and stoichiometric conditions (φ = 0.5, 1.0) with focus on the more-practical, fuel-lean conditions. Ignition delay times were measured from OH* chemiluminescence around 307 nm using an endwall diagnostic. The RON and MON of the surrogate were 90.3 and 84.7, respectively. Ethanol was chosen due to its wide use in flex-fuel vehicles and availability, while also providing an increased octane rating. Methyl acetate was chosen for its especially high octane rating to investigate the effect of an extreme case. To validate the gasoline surrogate, the data are compared to real gasoline (RD387) and several gasoline surrogate experiments from the literature. Using the wide range of pressures studied, the gasoline surrogate’s pressure dependence was quantified to account for test-to-test variations using regression analysis. Similarly, a global correlation for gasoline and its surrogates was developed using all available data from the literature. Two modern chemical kinetics models targeting gasoline and its surrogates are compared to the ignition delay time measurements. These new high-pressure, high-bioblendstock concentration tests provide required chemical kinetic data for optimizing fuel and engine design.

42 ENGINEERING↗

Quality Assurance for the Geometric Accuracy of Cone-Beam CT Guidance in Radiation Therapy

The introduction of volumetric X-ray image-guided radiotherapy systems allows improved management of geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, we propose a daily quality assurance (QA) program for cone-beam computed tomography (CBCT) integrated with a linear accelerator. The image-guided system used in this work combines a linear accelerator with conventional X-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis. This article focuses on daily QA protocols germane to geometric accuracy of the CBCT systems and proposes tolerance levels on the basis of more than 3 years of experience with seven CBCT systems used in our clinic. Monthly geometric calibration tests demonstrate the long-term stability of the flex movements, which are reproducible within {+-}0.5 mm (95% confidence interval). The daily QA procedure demonstrates that, for rigid phantoms, the accuracy of the image-guided process can be within 1 mm on average, with a 99% confidence interval of {+-}2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MicroPET/CT Imaging of an Orthotopic Model of Human Glioblastoma Multiforme and Evaluation of Pulsed Low-Dose Irradiation

Purpose: Glioblastoma multiforme (GBM) is an aggressive tumor that typically causes death due to local progression. To assess a novel low-dose radiotherapy regimen for treating GBM, we developed an orthotopic murine model of human GBM and evaluated in vivo treatment efficacy using micro-positron-emission tomography/computed tomography (microPET/CT) tumor imaging. Methods: Orthotopic GBM xenografts were established in nude mice and treated with standard 2-Gy fractionation or 10 0.2-Gy pulses with 3-min interpulse intervals, for 7 consecutive days, for a total dose of 14 Gy. Tumor growth was quantified weekly using the Flex Triumph (GE Healthcare/Gamma Medica-Ideas, Waukesha, WI) combined PET-single-photon emission CT (SPECT)-CT imaging system and necropsy histopathology. Normal tissue damage was assessed by counting dead neural cells in tissue sections from irradiated fields. Results: Tumor engraftment efficiency for U87MG cells was 86%. Implanting 0.5 x 10{sup 6} cells produced a 50- to 70-mm{sup 3} tumor in 10 to 14 days. A significant correlation was seen between CT-derived tumor volume and histopathology-measured volume (p = 0.018). The low-dose 0.2-Gy pulsed regimen produced a significantly longer tumor growth delay than standard 2-Gy fractionation (p = 0.045). Less normal neuronal cell death was observed after the pulsed delivery method (p = 0.004). Conclusion: This study successfully demonstrated the feasibility of in vivo brain tumor imaging and longitudinal assessment of tumor growth and treatment response with microPET/CT. Pulsed radiation treatment was more efficacious than the standard fractionated treatment and was associated with less normal tissue damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional graphene/LiFePO{sub 4} nanostructures as cathode materials for flexible lithium-ion batteries

Graphical abstract: Graphene/LiFePO{sub 4} composites as a high-performance cathode material for flexible lithium-ion batteries have been prepared by using a co-precipitation method to synthesize graphene/LiFePO4 powders as precursors and then followed by a solvent evaporation process. - Highlights: • Flexible LiFePO{sub 4}/graphene films were prepared first time by a solvent evaporation process. • The flexible electrode exhibited a high discharge capacity without conductive additives. • Graphene network offers the electrode adequate strength to withstand repeated flexing. - Abstract: Three-dimensional graphene/LiFePO{sub 4} nanostructures for flexible lithium-ion batteries were successfully prepared by solvent evaporation method. Structural characteristics of flexible electrodes were investigated by X-ray diffraction (XRD), atomic force microscopy (AFM) and scanning electron microscopy (SEM). Electrochemical performance of graphene/LiFePO{sub 4} was examined by a variety of electrochemical testing techniques. The graphene/LiFePO{sub 4} nanostructures showed high electrochemical properties and significant flexibility. The composites with low graphene content exhibited a high capacity of 163.7 mAh g{sup −1} at 0.1 C and 114 mAh g{sup −1} at 5 C without further incorporation of conductive agents.

36 MATERIALS SCIENCE↗

Standardization of Head and Neck Contouring Using the Acanthiomeatal Line

The purpose of this study was to determine the perceived and actual chin position(s) used for radiotherapy of head-and-neck cancers in a variety of clinical settings. Dosimetrists were asked to describe the external landmarks used to set the chin position. The lateral treatment planning radiographic figures in Ang's textbook, Radiotherapy for Head and Neck Cancers: Indications and Techniques, were analyzed for chin position by drawing a horizontal line from the tip of the chin to the cervical spine. The physicians at 7 departments were asked to rate the chin positions used in their departments for head-and-neck simulations. Choices included: (1) mildly flexed, (2) neutral, (3) mildly extended, and (4) hyperextended. In addition, each center was asked to select 2 representative cases to show routine chin position. The dosimetrists fixed the chin in neutral position by placing a virtual plane defined by 3 points (the base of the nasal septum [acanthus] and the external auditory canals) perpendicular to the table top. The type of head holder was irrelevant. Eighty-two percent (31/38) of the figures in Ang's text showed positioning in the neutral position (tip of the chin intersected the cervical spine between C2-3/C3-4). Most (71.4%) of the radiotherapists thought their patients were treated in the hyperextended neck position but, in fact, 85.7% (12/14) of the simulations showed a neural neck position. Reproducible chin positioning can be obtained by using the acanthiomeatal line. Consistent use of this technique will create a uniformly positioned set of axial co-images that have consistent appearance of avoidance and lymphatic areas. This will simplify contouring on axial computed tomography (CT) images of the neck. Standardizing the chin position is an important step to developing a standardized atlas and developing an information tool for automated contouring.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance tests of large thin vacuum windows

Tests of thin composition vacuum windows of the type used for the Tagger in Hall B at the Thomas Jefferson National Accelerator Facility are described. Three different tests have been performed. These include: (1) measurement of the deformation and durability of a window under long term (>8 years) almost continuous vacuum load, (2) measurement of the deformation as a function of flexing of the window as it is cycled between vacuum and atmosphere, and (3) measurement of the relative diffusion rate of gas through a variety of thin window membranes.

43 PARTICLE ACCELERATORS↗

Performance of the CLAS12 Silicon Vertex Tracker modules

For the 12 GeV upgrade, the CLAS12 experiment has designed a Silicon Vertex Tracker (SVT) using single sided microstrip sensors fabricated by Hamamatsu. The sensors have graded angle design to minimize dead areas and a readout pitch of 156{micro}m, with intermediate strip. Double sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module read out by four Fermilab Silicon Strip Readout (FSSR2) chips featuring data driven architecture, mounted on a rigid-flex hybrid. Modules are assembled on the barrel using unique cantilevered geometry to minimize the amount of material in the tracking volume. Design and performance of the SVT modules are presented, focusing on results of electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deformation Mechanisms of Vertically Stacked WS 2 /MoS 2 Heterostructures: The Role of Interfaces

Here, the mechanical and optical properties generated due to the stacking of different atomically thin materials have made it possible to tune and engineer these materials for next-generation electronics. The understanding of the interlayer interactions in such stacked structures is of fundamental interest for structure and property correlation. Here, a combined approach of in situ Raman spectroscopy and mechanical straining along with molecular dynamics (MD) simulations has been used to probe one such interface, namely, the WS 2 /MoS 2 heterostructure. Vertical heterostructures on poly(methyl methacrylate), when flexed, showed signs of decoupling at 1.2% strain. Theoretical calculations showed strain-induced stacking changes at 1.75% strain. The sliding characteristics of layers were also investigated using scanning probe microscopy based nanoscratch testing, and the results are further supported by MD simulations. The present study could be used to design future optoelectronic devices based on WS 2 /MoS 2 heterostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Elucidating the mechanism of a two-step spin transition in a nanoporous metal-organic framework.

The nanoporous metal-organic framework, Fe(bpe){sub 2}(NCS){sub 2}{center_dot}3(acetone), SCOF-4(Ac) (where bpe is 1,2-bis(4'-pyridyl)ethane), displays a two-step spin crossover (SCO) transition (65--155 K) that is sensitive to the presence of acetone guest molecules. Structural analyses have revealed a structural phase transition, from tetragonal (P{sub 4}2{sub 1}c) to orthorhombic (P2{sub 1}2{sub 1}2), associated with the spin transition that defines a checkerboard-like ordering of spin sites at the high-spin:low-spin plateau. The reversible desorption of the acetone guest species is accompanied by a complex series of structural phase transitions that describe a dramatic flexing of the structure. The thermal trapping of a metastable state with {approx}20--25% high-spin character was observed both magnetically and structurally upon rapid quenching of SCOF-4(Ac) to 10 and 25 K, respectively. The light-induced excited spin state trapping (LIESST) effects for SCOF-4(Ac) show a 55% excitation of a metastable HS state at 10 K and a characteristic T(LIESST) value of 52 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical Role of Framework Flexibility and Disorder in Driving High Ionic Conductivity in LiNbOCl 4

Understanding Li-ion transport is key for the rational design of superionic solid electrolytes with exceptional ionic conductivities. LiNbOCl 4 is reported to be one of the most highly conducting materials in the recently realized new class of soft oxyhalide solid electrolytes, exhibiting an ionic conductivity of ~11 mS·cm -1 . Here, we apply X-ray/neutron diffraction and pair distribution function analysis - coupled with density functional theory/ab-initio molecular dynamics - to determine a structural model that provides a rationale for the high conductivity that we observe experimentally in this nanocrystalline solid. We show that it arises from unusually high framework flexibility at room temperature. This owes to isolated 1-D [NbOCl 4 ] - anionic chains which exhibit energetically favorable orientational disorder that is - in turn - correlated to multiple, disordered and equi-energetic Li + sites in the lattice. As the Li-ions sample the 3-D energy landscape with a fast predicted diffusion coefficient of 5.1 x 10 -7 cm 2 /s at room temperature (σ i calc = 17.4 mS·cm -1 ), the inorganic polymer chains can reorient or vice versa. The activation energy barrier for Li migration through the frustrated energy landscape is especially reduced by the elastic nature of the NbO 2 Cl 4 octahedra evident from very widely dispersed Cl-Nb-Cl bond angles in AIMD snapshots at 300 K. The phonon spectra are predominantly influenced by Cl vibrations in the low energy range, and there is strong overlap between the framework (Cl, Nb) and Li partial pDOS in the region between 1.2 - 4.0 THz. The framework flexibility is also reflected in a relatively low bulk modulus of 22 GPa. In conclusion, our findings pave the way for investigation of future “flex-ion” inorganic solids and open up a new direction for the design of high conductivity, soft solid electrolytes for all-solid-state batteries.

AIMD↗

Basement Fault Reactivation by Fluid Injection Into Sedimentary Reservoirs: Poroelastic Effects

Abstract To investigate mechanisms of seismic fault reactivation in crystalline basement in response to fluid injection in overlying sedimentary reservoirs, we conducted three‐dimensional finite element simulations to assess the effects of direct pore pressure communication and indirect poroelastic stress transfer on the change in Coulomb failure stress of favorably oriented faults of varying permeability structure in normal, strike‐slip, and reverse faulting stress regimes. We demonstrate that the direct pore pressure effect transmitted along a hydraulically conductive fault exceeds the indirect poroelastic effect, but alone is insufficient for fault reactivation in the basement. The poroelastic effect on the Coulomb failure stress results from induced normal tractions and, to a lesser extent, from induced shear tractions that relate to the flexing of the fault as the reservoir expands poroelastically with fluid injection. Assuming a higher Biot coefficient for reservoir over basement rock as previously reported, the combined direct pore pressure and indirect poroelastic effects result in reactivation of hydraulically conductive faults in the basement in normal and strike‐slip faulting stress regimes and in the reservoir in reverse faulting regimes. Sealing normal faults that are not preferentially conductive also preferentially reactivate in the reservoir. These findings apply to injection in either hanging or footwall of normal and reverse faults. Reducing the contrast in Biot coefficient between reservoir and basement favors fault reactivation in the reservoir for injection in the footwall in normal faulting stress regimes. These simulations demonstrate that geomechanical models without coupled poroelasticity underestimate the potential of fault reactivation in crystalline basement.

Fan, Zhiqiang↗

Molecular mechanism of ATP binding and ion channel activation in P2X receptors

P2X receptors are trimeric ATP-activated ion channels permeable to Na{sup +}, K{sup +} and Ca{sup 2+}. The seven P2X receptor subtypes are implicated in physiological processes that include modulation of synaptic transmission, contraction of smooth muscle, secretion of chemical transmitters and regulation of immune responses. Despite the importance of P2X receptors in cellular physiology, the three-dimensional composition of the ATP-binding site, the structural mechanism of ATP-dependent ion channel gating and the architecture of the open ion channel pore are unknown. Here we report the crystal structure of the zebrafish P2X4 receptor in complex with ATP and a new structure of the apo receptor. The agonist-bound structure reveals a previously unseen ATP-binding motif and an open ion channel pore. ATP binding induces cleft closure of the nucleotide-binding pocket, flexing of the lower body {beta}-sheet and a radial expansion of the extracellular vestibule. The structural widening of the extracellular vestibule is directly coupled to the opening of the ion channel pore by way of an iris-like expansion of the transmembrane helices. The structural delineation of the ATP-binding site and the ion channel pore, together with the conformational changes associated with ion channel gating, will stimulate development of new pharmacological agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic intercalation to measure adhesion of graphene on graphite

The interest in mechanical properties of layered and 2D materials has reemerged in light of device concepts that take advantage of flexing, adhesion and friction in such systems. Here we provide an effective measurement of the nanoscale elastic adhesion of a graphene sheet atop highly ordered pyrolytic graphite (HOPG) based on the analysis of atomic intercalates in graphite. Atomic intercalation is carried out using conventional ion sputtering, creating blisters in the top-most layer of the HOPG surface. Scanning tunneling microscopy coupled with image analysis and density functional theory are used to reconstruct the atomic positions and the strain map within the deformed graphene sheet, as well as to demonstrate subsurface diffusion of the ions creating such blisters. To estimate the adhesion energy we invoke an analytical model originally devised for macroscopic deformations of graphene. This model yields a value of 0.221 ± 0.011 J/m -2 for the adhesion energy of graphite, which is in surprisingly good agreement with reported experimental and theoretical values. This implies that macroscopic mechanical properties of graphene scale down to at least a few nanometers length. The simplicity of our method, compared to the macroscale characterization, enables analysis of elastic mechanical properties in two-dimensional layered materials and provides a unique opportunity to investigate the local variability of mechanical properties on the nanoscale.

36 MATERIALS SCIENCE↗