Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEXIBLE GENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Engineering the Spectrum of Dipole Field-Localized Spin-Wave Modes to Enable Spin-Torque Antidamping

Auto-oscillation of a ferromagnet due to spin-orbit torques in response to a dc current is of wide interest as a flexible mechanism for generating controllable high-frequency magnetic dynamics. However, degeneracies of the spin-wave modes and nonlinear magnon-magnon scattering impede coherent precession. Discretization of the spin-wave modes can reduce this scattering. Furthermore, spatial localization of the spin-wave modes by the strongly inhomogeneous dipole magnetic field of a nearby spherical micromagnet provides variable spatial confinement, thus offering the option of systematic tunability of magnon spectrum for studying multimode interactions. Here we demonstrate that field localization generates a discrete spin-wave spectrum observable as a series of well-resolved localized modes in the presence of imposed spin currents arising from the spin Hall effect in a permalloy-platinum (Py/Pt) microstrip. The observation of linewidth reduction through damping control in this micromagnetically engineered spectrum demonstrates that localized modes can be controlled efficiently, an important step toward continuously tunable spin Hall effect–driven auto-oscillators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

SU-F-J-204: Carbon Digitally Reconstructed Radiography (CDRR): A GPU Based Tool for Fast and Versatile Carbonimaging Simulation

Purpose: Research in carbon imaging has been growing over the past years, as a way to increase treatment accuracy and patient positioning in carbon therapy. The purpose of this tool is to allow a fast and flexible way to generate CDRR data without the need to use Monte Carlo (MC) simulations. It can also be used to predict future clinically measured data. Methods: A python interface has been developed, which uses information from CT or 4DCT and thetreatment calibration curve to compute the Water Equivalent Path Length (WEPL) of carbon ions. A GPU based ray tracing algorithm computes the WEPL of each individual carbon traveling through the CT voxels. A multiple peak detection method to estimate high contrast margin positioning has been implemented (described elsewhere). MC simulations have been used to simulate carbons depth dose curves in order to simulate the response of a range detector. Results: The tool allows the upload of CT or 4DCT images. The user has the possibility to selectphase/slice of interested as well as position, angle…). The WEPL is represented as a range detector which can be used to assess range dilution and multiple peak detection effects. The tool also provides knowledge of the minimum energy that should be considered for imaging purposes. The multiple peak detection method has been used in a lung tumor case, showing an accuracy of 1mm in determine the exact interface position. Conclusion: The tool offers an easy and fast way to simulate carbon imaging data. It can be used for educational and for clinical purposes, allowing the user to test beam energies and angles before real acquisition. An analysis add-on is being developed, where the used will have the opportunity to select different reconstruction methods and detector types (range or energy). Fundacao para a Ciencia e a Tecnologia (FCT), PhD Grant number SFRH/BD/85749/2012.

60 APPLIED LIFE SCIENCES↗

Transuranic Waste Facility: Evaluation of Material-at-Risk Limits

The purpose of this analysis was to provide an evaluation and justification of the differences in the safety-basis parameters of Area G and the proposed TRU Waste Facility (TWF) in response to a request from the Los Alamos Field Office. Many of the differences in safety parameters stem from physical attributes such as facility location, size, and updated safety-basis requirements, etc. However, the primary safety-basis parameter that LANL and the Los Alamos Field Office can control for the proposed TWF is the required MAR limit. Based on the following analysis, LANL has proposed to reduce the overall facility MAR from 30,000 PE Ci to 21,400 PE Ci, and the waste storage buildings from 4,550 PE Ci to 3,200 PE Ci. The recommendation balances program requirements, operational considerations, facility construction cost, and container costs. To implement the reduced MAR strategy above, the Los Alamos Field Office and LANL will need to work with WIPP to ensure two characterization/shipment campaigns are scheduled each year. The analysis in this document included a review of historical trends and potential future scenarios in activity for enduring waste containers to define the expected normal operating range. The first part of the MAR analysis resulted in a newly defined range of activity of 10.5-18.0 PE Ci per DE2= expected for the design life of the new TWF. However, for accident scenario analysis, containers will use the WIPP WAC limits because there are no other individual container controls. Specifically, accident scenarios involving less than the building MAR will use the 80-PE Ci WIPP-WAC limit for drums. The accident analyses are intended to bound the potential impacts, and are not intended to be based on normal operational ranges. The Field Office also requested that LANL evaluate a potential reduction of the waste storage building MAR Limit by a factor of two to three. LANL used the newly defined MAR range of 10.5-18.0 PE Ci/DE to define upper and lower MAR boundary requirements using three containerization scenarios. The result of the analysis showed that the most probable scenario of future operations that balances costs, drum packaging efficiency, and shipment efficiency will routinely require the use of one-third to two-thirds of the MAR limit for each building. This result, paired with scenarios that could potentially provide short-term MAR increases, demonstrates that the MAR cannot be reduced by a factor as large as two to three, but can be reduced from 4,550 PE Ci to 3,200 PE Ci for waste storage buildings (a reduction of 30%). The TWF PDSA submittal contained combustibility values for enduring waste that appeared relatively large compared to Area G. The analysis provided the basis for the initial combustibility values established in the PDSA. Although the recent data provided combustibility values that were much lower than the PDSA assumptions (27% versus 80% in PDSA), the analysis shows that there is variability in combustible loading over time. For safety-basis accident scenarios, the material composition distribution for waste containers will be included in the MAR requirement by assuming all waste is combustible instead of applying a control for combustible loading. For operations and programs, it is better to assume 100% combustibles and maintain flexibility for waste generator containerization rather than to maintain a requirement for administrative controls of combustible loading. Controlling MAR through administrative controls is difficult for both the generator and waste management operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating the Value of Utility-Scale Solar Technologies in California Under a 40% Renewable Portfolio Standard

Concentrating solar power with thermal energy storage (CSP-TES) is a unique source of solar energy in that its output can be shifted over time. The ability of CSP-TES to be a flexible source of generation may be particularly valuable in regions with high overall penetration of solar energy, such as the state of California. California's Renewable Portfolio Standard (RPS) requires the state to increase generation from eligible renewable energy resources to reach 33% of retail electricity sales by 2020. Beyond 2020, California targets a further reduction in greenhouse gas emissions. To help reach this goal, current California governor Jerry Brown has stated that a higher 40% RPS might be reachable in the near term. The levelized cost of energy is generally emphasized when assessing the economic viability of renewable energy systems implemented to achieve the RPS. However, the operational and capacity benefits of such systems are often ignored, which can lead to incorrect economic comparisons between CSP-TES and variable renewable generation technologies such as solar photovoltaics (PV). Here we evaluate a 40% RPS scenario in a California grid model with PV or CSP-TES providing the last 1% of RPS energy. We compare the technical and economic implications of integrating either solar technology under several sensitivities, finding that the ability to displace new conventional thermal generation capacity may be the largest source of value of CSP-TES compared to PV at high solar penetrations.

14 SOLAR ENERGY↗

An approach for shear-stress based scour prediction

Scour beneath seafloor pipelines, cables, and other offshore infrastructure is a well-known problem. Recent interest in seafloor mounted wave energy converters brings another dynamic element into the traditional seafloor scour problem. In this paper, we consider the M3 Wave APEX device, which utilizes airflow between two flexible chambers to generate electricity from waves. In an initial at-sea deployment of a demonstration/experimental APEX in September 2014 off the coast of Oregon, scour beneath the device was observed. As sediment from the beneath the device was removed by scour, the device's pitch orientation was shifted. This change in pitch orientation caused a degradation in power performance. Characterizing the scour associated with seafloor mounted wave energy conversion devices such as the M3 device is the objective of the present work.

16 TIDAL AND WAVE POWER↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.9, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

13 HYDRO ENERGY↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Operationally Flexible Diafiltration Membrane Systems for Critical Mineral Separations

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Yao, Jason↗

Treatment and Mineral Recovery from Combustion Residual Leachate and Produced Water

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Able, Chad↗

Distribution Grid Model Publication Investigation

Interest in the external exchange of distribution grid model data is growing around the world, driven largely by the challenges and opportunities presented by the increasing amount of generation, storage, and flexible load being embedded within the distribution grid. This report provides an overview of the current state of distribution grid model data sharing, with a focus on the industry-leading activities currently underway in Great Britain (GB). A second report will explore opportunities for external distribution grid model sharing in the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Measure Documentation: Lighting Control for Load Shedding

This report describes the modeling methodology for a single end-use savings shape measure - lighting control for load shedding - and briefly introduces key results. The lighting control for load shedding measure applies lighting dimming control to reduce the lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then adjusts the lighting dimming level by a percentage reduction from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 2%-7% daily peak demand reduction performance for applicable buildings, and 0.43% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPACITY MEASUREMENT AND THEORETICAL INVESTIGATION OF HOT SILICON PLASMA

We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm{sup −3} in the photon energy range of 1790–1880 eV. A 23 μg cm{sup −2} Si foil tamped by 50 μg cm{sup −2} CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s − 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.

79 ASTRONOMY AND ASTROPHYSICS↗

SICOPOLIS-AD v1: an open-source adjoint modeling framework for ice sheet simulation enabled by the algorithmic differentiation tool OpenAD

We present a new capability of the ice sheet model SICOPOLIS that enables flexible adjoint code generation via source transformation using the open-source algorithmic differentiation (AD) tool OpenAD.The adjoint code enables efficient calculation of the sensitivities of a scalar-valued objective function or quantity of interest (QoI) to a range of important, often spatially varying and uncertain model input variables, including initial and boundary conditions, as well as model parameters.Compared to earlier work on the adjoint code generation of SICOPOLIS, our work makes several important advances:(i) it is embedded within the up-to-date trunk of the SICOPOLIS repository – accounting for 1.5 decades of code development and improvements – and is readily available to the wider community;(ii) the AD tool used, OpenAD, is an open-source tool;(iii) the adjoint code developed is applicable to both Greenland and Antarctica, including grounded ice as well as floating ice shelves, with an extended choice of thermodynamical representations.A number of code refactorization steps were required. They are discussed in detail in an Appendix as they hold lessons for the application of AD to legacy codes at large.As an example application, we examine the sensitivity of the total Antarctic Ice Sheet volume to changes in initial ice thickness, austral summer precipitation, and basal and surface temperatures across the ice sheet.Simulations of Antarctica with floating ice shelves show that over 100 years of simulation the sensitivity of total ice sheet volume to the initial ice thickness and precipitation is almost uniformly positive, while the sensitivities to surface and basal temperature are almost uniformly negative. Sensitivity to austral summer precipitation is largest on floating ice shelves from Queen Maud to Queen Mary Land. The largest sensitivity to initial ice thickness is at outlet glaciers around Antarctica. Comparison between total ice sheet volume sensitivities to surface and basal temperature shows that surface temperature sensitivities are higher broadly across the floating ice shelves, while basal temperature sensitivities are highest at the grounding lines of floating ice shelves and outlet glaciers. A uniformly perturbed region of East Antarctica reveals that, among the four control variables tested here, total ice sheet volume is the most sensitive to variations in austral summer precipitation as formulated in SICOPOLIS.Comparison between adjoint- and finite-difference-derived sensitivities shows good agreement, lending confidence that the AD tool is producing correct adjoint code.The new modeling infrastructure is freely available at http://www.sicopolis.net (last access: 2 April 2020) under the development trunk.

58 GEOSCIENCES↗

Going beyond BEM with BEM: an insight into dynamic inflow effects on floating wind turbines

Blade element momentum (BEM) theory is the backbone of many industry-standard wind turbine aerodynamic models. To be applied to a broader set of engineering problems, BEM models have been extended since their inception and now include several empirical corrections. These models have benefitted from decades of development and refinement and have been extensively used and validated, proving their adequacy in predicting aerodynamic forces of horizontal-axis wind turbine rotors in most scenarios. However, the analysis of floating offshore wind turbines (FOWTs) introduces new sets of challenges, especially if new-generation large and flexible machines are considered. In fact, due to the combined action of wind and waves and their interaction with the turbine structure and control system, these machines are subject to unsteady motion and thus unsteady inflow on the wind turbine's blades, which could put BEM models to the test. Consensus has not been reached on the accuracy limits of BEM in these conditions. This study contributes to the ongoing research on the topic by systematically comparing four different aerodynamic models, ranging from BEM to computational fluid dynamics, in an attempt to shed light on the unsteady aerodynamic phenomena that are at stake in FOWTs and whether BEM is able to model them appropriately. Simulations are performed on the UNAFLOW 1:75 scale rotor during imposed harmonic surge and pitch motion. Experimental results are available for these conditions and are used for baseline validation. The rotor is analyzed in both rated operating conditions and low wind speeds, where unsteady aerodynamic effects are expected to be more pronounced. Results show that BEM, despite its simplicity, can adequately model the aerodynamics of FOWTs in most conditions if augmented with a dynamic inflow model.

17 WIND ENERGY↗

Stabilizing the elastic modes of the Space Shuttle vehicle during launch.

The influence of vibration modes on the vehicle control system stabilization problem is examined with a conventional, nonadaptive, single-rate-sensor autopilot. The linear stability analyses are based upon symmetric and antisymmetric modal data generated from flexible-beam models. Primary emphasis is placed upon using only the three orbiter engines as control effectors. Principal control system variables considered are the effective autopilot rate and attitude gains, rate and attitude sensor locations, and lead/lag stability compensation. Results indicate that a multiple-sensor autopilot configuration will be necessary to achieve satisfactory vibration mode stability margins.

Greiner, H. G.↗