Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUCTUATION ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Macrofossil records of West Antarctic Ice Sheet retreat during the Holocene

Marine macrofossils in emerged beaches around Antarctica represent a geochemical framework for interpreting meltwater signatures associated with variations in the adjacent ice sheet margins during the last 10,000 years. In particular, mollusc species provide ideal experimental templates for assessing hydrochemical variations in Antarctic coastal marine environments because of their excellent preservation, high abundances, circumpolar distributions, and carbonate shells, which incorporate trace elements and stable isotopes. Modern samples of the bivalve Adamussium colbecki, which were collected across a depth gradient in the vicinity of a glacial meltwater stream in West McMurdo Sound, revealed shell trace element concentrations that were significantly higher above 10 meters because of their exposure to meltwater runoff. This meltwater signature also was reflected by the shell oxygen isotopic composition, which was in equilibrium with the ambient seawater, as demonstrated by the overlap between the predicted and actual O-(delta-18)sub w values. These modern samples provide analogs for interpreting the geochemical records in their fossils, which were based solely on molluscan fossils, complement the above geochemical data by suggesting that the rate of beach emergence fluctuated around Antarctica during the mid-Holocene. Paleoenvironmental analysis of macrofossils from emerged beaches represents a new direction in Antarctic research that can be used to assess changes in the margins of the ice sheets since the Last Glacial Maximum. The resolution of these analyses will be enhanced by collaborations that are developing with scientists who are conducting comparable studies in other coastal regions around the continent.

Berkman, Paul Arthur↗

Simultaneous measurement of velocity and temperature fluctuations in the boundary layer of a supersonic flow

The instantaneous velocity and temperature behavior of a Mach 3 turbulent boundary layer was studied using two closely spaced constant temperature hot wires. By operating the wires at different temperatures, it was possible to obtain the instantaneous velocity and temperature fluctuations and to evaluate the strong Reynolds analogy. Our analysis revealed that the strong Reynolds analogy is a good approximation for describing the instantaneous velocity and temperature behavior for the inner 70 percent of the boundary layer.

Smith, Douglas R.↗

A Rationale for System-Dependent Advantages and Disadvantages of Solution Crystal Growth at Low Gravity

Protein crystallization experiments at reduced gravity have yielded crystals that, depending on the specific material, are either superior or inferior in their structural perfection compared to counterparts grown at normal gravity. A reduction of the crystals' quality due to their growth at low gravity cannot be understood from existing models. Our experimental investigations of the ground-based crystallization of the protein lysozyme have revealed pronounced unsteady growth layer dynamics and associated defect formation under steady external conditions. Through scaling analysis and numerical simulations we show that the observed fluctuations originate from the coupling of bulk transport with non-linear interface kinetics under mixed kinetics-transport control of the growth rate. The amplitude of the fluctuations is smallest when either transport or interfacial kinetics dominate the control of the crystallization process. Thus, depending on the specific system, crystal quality may be improved by either enhancing or suppressing the transport in the solution. These considerations provide, for the first time, a material-dependent rationale for the advantages, as well as the disadvantages, of reduced gravity for (protein) crystallization.

Rosenberger, Franz↗

Enhanced Spectral Anisotropies Near the Proton-Cyclotron Scale: Possible Two-Component Structure in Hall-FLR MHD Turbulence Simulations

Recent analysis of the magnetic correlation function of solar wind fluctuations at 1 AU suggests the existence of two-component structure near the proton-cyclotron scale. Here we use two-and-one-half dimensional and three-dimensional compressible MHD models to look for two-component structure adjacent the proton-cyclotron scale. Our MHD system incorporates both Hall and Finite Larmor Radius (FLR) terms. We find that strong spectral anisotropies appear adjacent the proton-cyclotron scales depending on selections of initial condition and plasma beta. These anisotropies are enhancements on top of related anisotropies that appear in standard MHD turbulence in the presence of a mean magnetic field and are suggestive of one turbulence component along the inertial scales and another component adjacent the dissipative scales. We compute the relative strengths of linear and nonlinear accelerations on the velocity and magnetic fields to gauge the relative influence of terms that drive the system with wave-like (linear) versus turbulent (nonlinear) dynamics.

Ghosh, Sanjoy↗

Analyzing Non Stationary Processes in Radiometers

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory for many scientific and engineering applications. Non linear effects of the observation methodology is one of the most perplexing aspects to modeling non stationary processes. This perplexing problem was encountered when modeling the effect of non stationary receiver fluctuations on the performance of radiometer calibration architectures. Existing modeling approaches were found not applicable; particularly problematic is modeling processes across scales over which they begin to exhibit non stationary behavior within the time interval of the calibration algorithm. Alternatively, the radiometer output is modeled as samples from a sequence random variables; the random variables are treated using a conditional probability distribution function conditioned on the use of the variable in the calibration algorithm. This approach of treating a process as a sequence of random variables with non stationary stochastic moments produce sensible predictions of temporal effects of calibration algorithms. To test these model predictions, an experiment using the Millimeter wave Imaging Radiometer (MIR) was conducted. The MIR with its two black body calibration references was configured in a laboratory setting to observe a third ultra-stable reference (CryoTarget). The MIR was programmed to sequentially sample each of the three references in approximately a 1 second cycle. Data were collected over a six-hour interval. The sequence of reference measurements form an ensemble sample set comprised of a series of three reference measurements. Two references are required to estimate the receiver response. A third reference is used to estimate the uncertainty in the estimate. Typically, calibration algorithms are designed to suppress the non stationary effects of receiver fluctuations. By treating the data sequence as an ensemble collection, it is possible to apply temporal algorithms which exacerbate the non stationary effects. By varying the algorithm, information about the properties of the non stationary receiver fluctuations is obtained. Comparisons of analytical calculations and statistical analysis of data demonstrate impressive agreement.

Racette, Paul↗

Time-Frequency Analysis of Rocket Nozzle Wall Pressures During Start-up Transients

Surveys of the fluctuating wall pressure were conducted on a sub-scale, thrust- optimized parabolic nozzle in order to develop a physical intuition for its Fourier-azimuthal mode behavior during fixed and transient start-up conditions. These unsteady signatures are driven by shock wave turbulent boundary layer interactions which depend on the nozzle pressure ratio and nozzle geometry. The focus however, is on the degree of similarity between the spectral footprints of these modes obtained from transient start-ups as opposed to a sequence of fixed nozzle pressure ratio conditions. For the latter, statistically converged spectra are computed using conventional Fourier analyses techniques, whereas the former are investigated by way of time-frequency analysis. The findings suggest that at low nozzle pressure ratios -- where the flow resides in a Free Shock Separation state -- strong spectral similarities occur between fixed and transient conditions. Conversely, at higher nozzle pressure ratios -- where the flow resides in Restricted Shock Separation -- stark differences are observed between the fixed and transient conditions and depends greatly on the ramping rate of the transient period. And so, it appears that an understanding of the dynamics during transient start-up conditions cannot be furnished by a way of fixed flow analysis.

Baars, Woutijn J.↗

Analysis and interpretation of X-ray pulsars

By careful measurements of the fluctuations in pulsar pulse periods on time scales of days and longer, researchers determined that these fluctuations are caused by changes in the rotation rate of the stellar crust apparently arising from matter accretion. The study of these fluctuations is a particularly promising way to determine the properties of accreting pulsars, because stellar rotation is relatively simple in comparison to much other X-ray source physics and can be investigated in detail. Rotation rates can be determined precisely.

Boynton, Paul E.↗

Shadowgraph Study of Gradient Driven Fluctuations

A fluid or fluid mixture, subjected to a vertical temperature and/or concentration gradient in a gravitational field, exhibits greatly enhanced light scattering at small angles. This effect is caused by coupling between the vertical velocity fluctuations due to thermal energy and the vertically varying refractive index. Physically, small upward or downward moving regions will be displaced into fluid having a refractive index different from that of the moving region, thus giving rise to the enhanced scattering. The scattered intensity is predicted to vary with scattering wave vector q, as q(sup -4), for sufficiently large q, but the divergence is quenched by gravity at small q. In the absence of gravity, the long wavelength fluctuations responsible for the enhanced scattering are predicted to grow until limited by the sample dimensions. It is thus of interest to measure the mean-squared amplitude of such fluctuations in the microgravity environment for comparison with existing theory and ground based measurements. The relevant wave vectors are extremely small, making traditional low-angle light scattering difficult or impossible because of stray elastically scattered light generated by optical surfaces. An alternative technique is offered by the shadowgraph method, which is normally used to visualize fluid flows, but which can also serve as a quantitative tool to measure fluctuations. A somewhat novel shadowgraph apparatus and the necessary data analysis methods will be described. The apparatus uses a spatially coherent, but temporally incoherent, light source consisting of a super-luminescent diode coupled to a single-mode optical fiber in order to achieve extremely high spatial resolution, while avoiding effects caused by interference of light reflected from the various optical surfaces that are present when using laser sources. Results obtained for a critical mixture of aniline and cyclohexane subjected to a vertical temperature gradient will be presented. The sample was confined between two horizontal parallel sapphire plates with a vertical spacing of 1 mm. The temperatures of the sapphire plates were controlled by independent circulating water loops that used Peltier devices to add or remove heat from the room air as required. For a mixture with a temperature gradient, two effects are involved in generating the vertical refractive index gradient, namely thermal expansion and the Soret effect, which generates a concentration gradient in response to the applied temperature gradient. For the aniline/cyclohexane system, the denser component (aniline) migrates toward the colder surface. Consequently, when heating from above, both effects result in the sample density decreasing with altitude and are stabilizing in the sense that no convective motion occurs regardless of the magnitude of the applied temperature gradient. The Soret effect is strong near a binary liquid critical point, and thus the dominant effect is due to the induced concentration gradient. The results clearly show the divergence at low q and the predicted gravitational quenching. Results obtained for different applied temperature gradients at varying temperature differences from the critical temperature, clearly demonstrate the predicted divergence of the thermal diffusion ratio. Thus, the more closely the critical point is approached, the smaller becomes the temperature gradient required to generate the same signal. Two different methods have been used to generate pure concentration gradients. In the first, a sample cell was filled with a single fluid, ethylene glycol, and a denser miscible fluid, water, was added from below thus establishing a sharp interface to begin the experiment. As time went on the two fluids diffused into each other, and large amplitude fluctuations were clearly observed at low q. The effects of gravitational quenching were also evident. In the second method, the aniline/cyclohexane sample was used, and after applying a vertical temperature gradient for several hours, the top and bottom temperatures were set equal and the thermal gradient died on a time scale of seconds, leaving the Soret induced concentration gradient in place. Again, large-scale fluctuations were observed and died away slowly in amplitude as diffusion destroyed the initial concentration gradient.

Cannell, David↗

Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line

During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures (Fig 6). Section wall reduction in the burst region. Plastic deformation and thinning of the out-of-specification tube wall likely happened during the initial proof testing years ago. Metallography of tubing away from rupture site confirmed tubing was seamless. Based on the tube microstructure, it is likely that the initial wall thickness was about 30 % thinner than the requirement of 0.049 inches. Fracture initiated on the ID and progressed to the OD (shear lip). The tube is made of the correct material of 5052-0 aluminum as verified using Optical Emission Spectroscopy (Table 2). The tubing hardness tested 77 HV100 (77 HRE). This hardness is slightly above the requirement for 70 HRE maximum for aluminum 5052-0 in AMS 2658C [3].

Martinez, J. E.↗

Combustion contribution to noise in jet engines

The relative importance of combustion as a source of noise in a flow regime representative of a subsonic jet engine exhaust was investigated. The combustion noise source characteristics were obtained from pressure and temperature fluctuation measurements in the combustor and exhaust nozzle. The similarity between the fluctuations in this source region and the far field noise were compared. In the jet exhaust velocity range between 450 and 660 ft/sec investigated in detail, the frequencies of dominant pressure and temperature fluctuations in the combustor were also the frequencies of the dominant far field noise. The overall noise levels were 14 to 20 dB higher than from a corresponding clean jet in the same velocity range. Thus it seemed clear that the unsteadiness associated with the combustion process was responsible for the dominant noise in the far field. A simple analysis to predict the far field noise due to the internal pressure fluctuations causing exit plane velocity fluctuations produced trends closely resembling the measured results, but under predicted the far field noise over the spectral range examined. The possible reason for the higher far field noise is direct transmission of acoustic waves through the nozzle, which was not accounted for in the prediction scheme.

Plett, E. G.↗

Use of leaning vanes for fan noise reduction.

The obliquity of blade-vane interactions in an axial fan and its influence on noise generation are examined. Analysis indicates that leaning vanes decrease the amplitudes of the fluctuating pressures at the rotor-stator plane and modify the radial distribution. These changes lead to considerable cancellation in the near field and consequent reduction in radiated acoustic power. Acoustic measurements on a small scale fan with radial and leaning vanes compare favorably with analytical predictions.

Rao, G. V. R.↗

Microscale Alfven waves in the solar wind at 1 AU

Analysis of IMP 1 (Explorer 43) plasma and magnetic field fluctuations on a scale of one hour revealed that linearly and circularly polarized Alfven waves are rarely present in the solar wind at 1 AU. The most prevalent microscale fluctuations appeared to be large-amplitude Alfven waves with small but non-zero fluctuations in the magnetic field intensity. These waves are present about 40% of the time and are predominantly propagating away from the sun.

Burlaga, L. F.↗

Composite bolometers for submillimeter wavelengths

The fabrication and optimization of composite submillimeter wave bolometers with metal film absorbing elements and doped Ge thermometers are described. Performance characteristics are given for 4 x 4-mm bolometers designed for operation at both He-4 and He-3 temperatures. The performance expected from such bolometers when they are optimized for various values of background loading is calculated. Current dependent noise, which can arise from any of several sources, is included in the analysis. This can make it impossible to reach the background fluctuation noise limit. Feed structures for these bolometers which employ Winston light concentrators are described.

Nishioka, N. S.↗

Unsteady Newton-Busemann flow theory. III - Frequency dependence and indicial response

Hui and Tobak applied the complete unsteady Newton-Busemann flow theory to the study of dynamic stability of oscillating aerofoils and bodies in revolution. The present article extends the results to general frequencies that may be applicable to flutter analysis. The results are likewise applied to the indicial response fluctuations in unsteady flow at very high Mach numbers. The study shows that for a group of body shapes in Newtonian flow (including the cone and wedge), the aerodynamic response to a step change in angle of attack or pitching velocity contains an initial-instant impulse followed by a rapid adjustment to the new steady-flow conditions. The impulse component is in effect an apparent mass term analogous to that which occurs initially in the aerodynamic indicial response at the zero Mach number limit.

Hui, W. H.↗

Analysis of turbulence in shear flows using the stabilization principle

An analysis is made based upon the concept that the velocity fluctuations, and therefore, the Reynolds stresses, driven by the instability of the original flow grow until a new stable state is approached. The Reynolds stresses incorporated into the Orr-Sommerfeld equation are coupled with the main flow such that all the imaginary parts of the complex eigenvalues vanish, i.e., the original instability is eliminated. Using this stabilization principle, it is possible to find the Reynolds stresses as well as the mean velocity for plane Poiseuille flow with the Reynolds number slightly higher than the critical.

Zak, M.↗

Possible signatures of nonlinear MHD waves in the solar wind: UVCS observations and models

Recent ultraviolet coronagraph spectrometer (UVCS) white light channel observations are discussed. These data indicated quasi-periodic variations in the polarized brightness in the polar coronal holes. The Fourier power spectrum analysis showed significant peaks at about six minutes and possible fluctuations on longer time scales. The observations are consistent with the predictions of the nonlinear solitary-like wave model. The purpose of a planned study on plume and inter-plume regions of coronal holes, motivated by the result of a 2.5 magnetohydrodynamic model (MHD), is explained.

Ofman, L.↗

Structural Fluctuations and Thermophysical Properties of Molten II-VI Compounds

The objectives of the project are to conduct ground-based experimental and theoretical research on the structural fluctuations and thermophysical properties of molten II-VI compounds to enhance the basic understanding of the existing flight experiments in microgravity materials science programs as well as to study the fundamental heterophase fluctuation phenomena in these melts by: 1) conducting neutron scattering analysis and measuring quantitatively the relevant thermophysical properties of the II-VI melts (such as viscosity, electrical conductivity, thermal diffusivity and density) as well as the relaxation characteristics of these properties to advance the understanding of the structural properties and the relaxation phenomena in these melts and 2) performing theoretical analyses on the melt systems to interpret the experimental results. All the facilities required for the experimental measurements have been procured, installed and tested. Thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range of 500 C to 900 C. The measured diffusivity as a function of temperature agrees fairly well with published data. However, a relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the melt, was observed for the first time. An apparatus based on the transient torque induced by a rotating magnetic field has been developed to determine the viscosity and electrical conductivity of semiconducting liquids. Viscosity measurements on molten tellurium showed a similar relaxation behavior to the measured diffusivity. The density and volume expansion coefficients for pure Te and HgTe melts were measured as a function of temperature using a pycnometric method. A density maximum was found for both melts but no relaxation behavior was observed. Neutron scattering experiments were performed on the HgTe and HgZnTe melts and the results on pair distribution showed better resolution than previously reported. A simple kinetic theory, which contains the formation reactions of Te polymerization that increases the molecular weight, was proposed to interpret the relaxation behavior of HgZnTe viscosity data.

Su, Ching-Hua↗