Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOOTPRINT REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Solar-Thermal Ammonia Production Via a Nitride Looping Cycle [Slides]

Solar Thermal Ammonia Production has the potential to synthesize ammonia in a green, renewable process that can greatly reduce the carbon footprint left by conventional Haber-Bosch reaction. Ternary nitrides in the family A 3 B x N (A=Co, Ni, Fe; B=Mo; x=2,3) have been identified as a potential candidate for NH 3 production. Experiments with Co 3 Mo 3 N in Ammonia Synthesis Reactor demonstrate cyclable NH 3 production from bulk nitride under pure H 2 . Production rates were fairly flat in all the reduction steps with no evident dependence on the consumed solid-state nitrogen, as would be expected from catalytic Mars-van Krevelen mechanism. Material can be re-nitridized under pure N 2 . Bulk nitrogen per reduction step average between 25 – 40% of the total solid-state nitrogen. Selectivity to NH 3 stabilized at 55 – 60% per cycle. Production rates (NH 3 and N 2 ) become apparent above 600 °C at P(H 2 ) = 0.5 – 2 bar. Optimal point of operation to keep selectivity high without compromising NH 3 rates currently estimated at 650 °C and 1.5 - 2 bar. The next steps are to optimize production rates, examine effect of N 2 addition in NH 3 synthesis reaction, and test additional ternary nitrides.

14 SOLAR ENERGY↗

Full-Scale Implementation of Propane Biosparge System for In-Situ Remediation of 1,4-Dioxane - 20174

1,4-Dioxane is a common co-contaminant with chlorinated solvents but is not readily remediated via similar treatment approaches (e.g., sorption, reductive dechlorination). However, 1,4-dioxane can be cometabolically biodegraded in the presence of alkane gases and oxygen. At Vandenberg Air Force Base in California, USA, historical use of chlorinated solvents resulted in 1,4-dioxane in groundwater across three vertical groundwater zones. Between April 2013 and December 2016, laboratory testing and various field demonstrations were conducted by us, and others. The results from these tests showed in-situ propane biosparging as a promising technology for reduction of both chlorinated solvent and 1,4-dioxane concentrations, with up to 99 percent reduction in groundwater concentrations. Stable isotope probing (SIP) was also used in 2015 to verify that biodegradation was a (destructive) mechanism occurring in the subsurface.). The success of the propane biosparge demonstrations, and confirmation of the biodegradation mechanism via SIP, has led to the full-scale implementation of a propane biosparge treatment system at Site 24 at Vandenberg Air Force Base. The treatment area is a relatively small footprint (e.g., less than 61 meters (200 feet) long), with 83 new wells installed simultaneously across the three groundwater zones. Ultimately 93 wells will be connected to an above-ground treatment system the includes an air compressor, a propane tank, controls to ensure safe operating conditions, and nutrient amendment elements. This full-scale system is currently known to be among the first of its kind. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Nanostructured Molecular Sieves for Energy Efficient Industrial Separations

Due to the very small relative volatility difference between propane and propylene, current propane/propylene separation by distillation requires very tall distillation towers (150-250 theoretical plates) and large reflux ratios (up to 15), which is considered to be the most energy consuming large-scale separation process. Adsorptive separation processes are widely considered to be more energy-efficient alternatives to distillation. However, slow diffusion kinetics/mass transport rate through the adsorbent bed often limits the performance of such processes, so further improvements are possible if intra-particle mass transfer rates can be improved. Rive Technology, Inc. is developing and commercializing its proprietary mesoporous zeolite technology for catalysis and separation. With well-controlled intracrystalline mesoporosity, diffusion kinetics through such mesoporous zeolite based catalysts is much improved relative to conventional zeolites, leading to significantly better product selectivity. This 'proof-of-principle' project (DE-EE0003470) is intended to demonstrate that Rive mesoporous zeolite technology can be extended and applied in adsorptive propane/propylene separation and lead to significant energy saving compared to the current distillation process. In this project, the mesoporous zeolite Y synthesis technology was successfully extended to X and A zeolites that are more relevant to adsorbent applications. Mesoporosity was introduced to zeolite X and A for the first time while maintaining adequate adsorption capacity. Zeolite adsorbents were tested for liquid phase separation performance using a pulse flow test unit and the test results show that the separation selectivity of the mesoporous zeolite adsorbent is much closer to optimal for a Simulated Moving Bed (SMB) separation process and the enhanced mesoporosity lead to >100% increase of overall mass transport rate for propane and propylene. These improvements will significantly improve the performance of an adsorptive separation unit for propane/propylene separation compared with traditional zeolite adsorbents. The enhanced transport will allow for more efficient utilization of a given adsorbent inventory by reducing process cycle time, allowing a faster production rate with a fixed amount of adsorbent or smaller adsorbent inventory at a fixed production rate. Smaller adsorbent inventory would also lead to significant savings in the capital cost due to smaller footprint of the equipment. Energy consumption calculation, based on the pulse test results for rived NaX zeolite adsorbent, of a hypothetical moderate-scale SMB propane/propylene separation plant that processes 6000 BPSD refinery grade propylene (70% propylene) will consume about 60-80% less energy (both re-boiler and condenser duties) compared to a C3 splitter that process the same amount of feed. This energy saving also translates to a reduction of 30,000-35,000 tons of CO 2 emission per year at this moderate processing rate. The enhancement of mass transport achievable by introduction of controlled mesoporosity to the zeolite also opens the door for the technology to be applied to several other adsorption separation processes such as the separation of xylene isomers by SMB, small- and large scale production of O 2 /N 2 from air by pressure swing adsorption, the separation of CO 2 from natural gas at natural gas wellheads, and the purification of ultra-high purity H 2 from the off gas produced by steam-methane-reforming.

03 NATURAL GAS↗

Towards a fully printable battery : robocast deposition of separators.

The development of thin batteries has presented several interesting problems which are not seen in traditional battery sizes. As the size of a battery reaches a minimum, the usable capacity of the battery decreases due to the fact that the major constituent of the battery becomes the package and separator. As the size decreases, the volumetric contribution from the package and separator increases. This can result in a reduction of capacity from these types of batteries of nearly all of the available power. The development of a method for directly printing the battery layers, including the package, in place would help to alleviate this problem. The technology used in this paper to directly print battery components is known as robocasting and is capable of direct writing of slurries in complex geometries. This method is also capable of conformally printing on three dimensional surfaces, opening up the possibility of novel batteries based on tailoring battery footprints to conform to the available substrate geometry. Interfacial resistance can also be reduced by using the direct write method. Each layer is printed in place on the battery stack instead of being stacked one at a time. This ensures an intimate contact and seal at every interface within the cell. By limiting the resistance at these interfaces, we effectively help increase the useable capacity of our battery through increase transport capability. We have developed methodology for printing several different separator materials for use in a lithium cell. When combined with a printable cathode comprised of LiFePO{sub 4} (as seen in Figure 1) and a lithium anode, our battery is capable of delivering a theoretical capacity of 170 mAh g{sup -1}. This capacity is diminished by transport phenomena within the cell which limit the transport rate of the lithium ions during the discharge cycle. The material set chosen for the printable separator closely resemble those used in commercially available separators in order to keep the transport rates high within the cell during charge and discharge. In order to evaluate the effect of each layer being printed using the robocasting technique, coin cells using printed separator materials were assembled and cycled vs. Li/Li{sup +}. This allows for the standardization of a test procedure in order to evaluate each layer of a printed cell one layer at a time. A typical charge/discharge curve can be seen in Figure 2 using a printed LiFePO{sub 4} cathode and a printed separator with a commercial Celgard separator. This experiment was run to evaluate the loss in capacity and slowdown of transport within the cell due to the addition of the printed separator. This cell was cycled multiple times and showed a capacity of 75 mAh/g. The ability for this cell to cycle with good capacity indicates that a fully printable separator material is viable for use in a full lithium cell due to the retention of capacity. Most of the fully printed cathode and separator cells exhibit working capacities between 65 and 95 mAh/g up to this point. This capacity should increase as the efficiency of the printed separator increases. The ability to deposit each layer within the cell allows for intimate contact of each layer and ensures for a reduction of interfacial impedance of each layer within the cell. The overall effect of printing multiple layers within the cell will be an overall increase in the ionic conductivity during charge and discharge cycles. Several different polymer membranes have been investigated for use as a printed separator. The disadvantage of using polymer separators or solid electrolyte batteries is that they have relatively low conductivities at room temperature (10{sup -6} - 10{sup -8} S cm{sup -1}). This is orders of magnitude lower than the typically accepted 10{sup -3} S cm{sup -1} needed for proper ionic transport during battery discharge Because of their low conductivity, typical polymer separators such as polyethylene oxide (PEO) have a normal operational temperature well above ambient. At elevated temperature the conductivity of these polymers increases. These polymer membranes are, however, ideal for printable applications due to their ease of fabrication using the robocasting process and their ability to conform to surfaces uniformly. While the ability to print cathodes and separators is advantageous as a technology, several of the components still need to be fully optimized. The overall design for the full printed lithium cell can be seen in Figure 3. The printed cathode and separator will interface with a printed anode and current collector, using the LiFePO{sub 4} cycling to plate out a metallic lithium anode on the current collector during cycling. The ability to print every layer of the cell conformally using the robocasting technique will allow for ultimate flexibility in the application of a printed battery.

74 ATOMIC AND MOLECULAR PHYSICS↗

A High Power Density and High Efficiency Traction Drive Based on a Segmented Inverter and an Axial and Radial Flux Hybrid Machine

Eaton Corporation and Oak Ridge National Laboratory (ORNL) collaborated to develop a high performance traction drive system aimed at increasing power density and overall efficiency. The system integrates Eaton’s hybrid flux motor—combining radial and axial flux paths to convert end-winding and structural elements into torque-producing components—with ORNL’s high-power-density segmented inverter. This motor design achieves higher torque density within the same footprint as traditional radial flux machines by effectively utilizing end turns. ORNL’s segmented inverter reduces the DC bus capacitor requirement by over 50% compared to standard voltage source inverters (VSIs), achieving power densities exceeding 100 kVA/L. The dual-module architecture also enables six-phase operation, aligning with Eaton’s motor design. Together, the motor and inverter offer a compact, efficient traction drive system with the potential for significant reductions in system weight and improvements in powertrain efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Options for reducing a coal-fired plant's carbon footprint: Part. 1

Caps on greenhouse gas emissions are imminent in the US and they will change how we design tomorrow's coal-fired power plants. Efforts are already under way to develop alternative capture and sequestration technologies, mainly for CO{sub 2}. Unfortunately, the proposed processes all consume lots of energy, reducing plants' net output and efficiency. In Part 1 of our look at these technologies, we list and quantify the impacts of post combustion removal of CO{sub 2} from a coal plant's flue gas. Next month, in Part. 2 we will do the same for four other CO{sub 2} reduction techniques: oxyfuel combustion, using higher-temperature and higher-pressure boilers, cofiring biomass, and replacing some coal-fired capacity with renewable capacity. 10 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Corn Ethanol: The Surprisingly Effective Route for Natural Gas Consumption in the Transportation Sector

Proven reserves and production of natural gas (NG) in the United States have increased dramatically in the last decade, due largely to the commercialization of hydraulic fracturing. This has led to a plentiful supply of NG, resulting in a significantly lower cost on a gallon of gasoline-equivalent (GGE) basis. Additionally, NG is a domestic, non-petroleum source of energy that is less carbon-intensive than coal or petroleum products, and thus can lead to lower greenhouse gas emissions. Because of these factors, there is a desire to increase the use of NG in the transportation sector in the United States (U.S.). However, using NG directly in the transportation sector requires that several non-trivial challenges be overcome. One of these issues is the fueling infrastructure. There are currently only 1,375 NG fueling stations in the U.S. compared to 152,995 fueling stations for gasoline in 2014. Additionally, there are very few light-duty vehicles that can consume this fuel directly as dedicated or bi-fuel options. For example, in model year 2013Honda was the only OEM to offer a dedicated CNG sedan while a number of others offered CNG options as a preparation package for LD trucks and vans. In total, there were a total of 11 vehicle models in 2013 that could be purchased that could use natural gas directly. There are additional potential issues associated with NG vehicles as well. Compared to commercial refueling stations, the at-home refueling time for NG vehicles is substantial – a result of the small compressors used for home refilling. Additionally, the methane emissions from both refueling (leakage) and from tailpipe emissions (slip) from these vehicles can add to their GHG footprint, and while these emissions are not currently regulated it could be a barrier in the future, especially in scenarios with broad scale adoption of CNG vehicles. However, NG consumption already plays a large role in other sectors of the economy, including some that are important to the transportation sector. Examples include steam reforming of natural gas to provide hydrogen for hydrotreating unit operations within the refinery and production of urea for use as a reductant for diesel after treatment in selective catalytic reduction (SCR). This discussion focuses on the consumption of natural gas in the production pathway of conventional ethanol (non-cellulosic) from corn through fermentation. Though it is clear that NG would also play a significant role in the cellulosic production pathways, those cases are not considered in this analysis.

03 NATURAL GAS↗

Development of Mixed-Salt Technology for CO 2 Capture from Coal Power Plants

SRI International (SRI), in collaboration with Stanford University, OLI Systems (OLI), Politecnico de Milano (PoliMi), and Aqueous Systems Aps (ASApS) performed a 45-month effort to develop a promising Mixed-Salt Process (MSP) for carbon dioxide capture. The MSP combines existing ammonia and potassium-carbonate technologies with improved absorption steps for rate enhancement and ammonia emission reduction and a novel selective regeneration process with a high-pressure CO 2 product to introduce a new and advanced transformational solvent-based technology. The striking advantages of the SRI MSP include: low heat of reaction, high loading of CO 2 , high-pressure regeneration of > 99% pure dry CO 2 , low sensitivity to impurities, low process cost, use of a non-degradable low-cost solvent with a very low carbon footprint for its production, low emissions, and reduced water use compared to the state-of-the-art ammonia-based and amine technologies. The overall objective of the project was to develop and test a solvent-based CO 2 capture technology that can capture CO 2 from existing or new pulverized coal (PC) power plants at low cost. Our specific goal was to test SRI’s newly developed MSP at the large bench-scale level to demonstrate that the process could capture CO 2 at high efficiency (> 90%) with very high CO 2 loading (> 10 wt.%), require less than 2 GJ/tonne for solvent regeneration, and produce a CO 2 stream at high pressure with a purity > 95 vol.%. This 45-month MSP development program was designed to conduct (1) extensive test campaigns with different process flowsheet variants, and (2) detailed thermodynamic, kinetic, and process modeling. These tests and models were very important to identify any issues associated with the process in the early stages and then resolve them before moving into the next scale-up (> 1 MWe scale) testing. The technology development plan consisted of balanced experimental and process modeling activities as shown in Figure i. Such an approach reduces the risks associated with the process operability at large scales and provides capital and operating expenditure (CAPEX/OPEX) predictions with improved accuracies. Under the MSP development program at SRI, we performed an aggressive testing campaign with individual subsystems as well as integrated CO 2 capture and regeneration system to identify the best operating conditions. The project was carried out in two budget periods (BP1 & BP2).

20 FOSSIL-FUELED POWER PLANTS↗

Development of Mixed-Salt Technology for CO 2 Capture from Coal Power Plants (Final Report)

SRI International (SRI), in collaboration with Stanford University, OLI Systems (OLI), Politecnico de Milano (PoliMi), and Aqueous Systems Aps (ASApS) performed a 45-month effort to develop a promising Mixed-Salt Process (MSP) for carbon dioxide capture. The MSP combines existing ammonia and potassium-carbonate technologies with improved absorption steps for rate enhancement and ammonia emission reduction and a novel selective regeneration process with a high-pressure CO 2 product to introduce a new and advanced transformational solvent-based technology. The striking advantages of the SRI MSP include: low heat of reaction, high loading of CO 2 , high-pressure regeneration of > 99% pure dry CO 2 , low sensitivity to impurities, low process cost, use of a non-degradable low-cost solvent with a very low carbon footprint for its production, low emissions, and reduced water use compared to the state-of-the-art ammonia-based and amine technologies. The overall objective of the project was to develop and test a solvent-based CO 2 capture technology that can capture CO 2 from existing or new pulverized coal (PC) power plants at low cost. Our specific goal was to test SRI’s newly developed MSP at the large bench-scale level to demonstrate that the process could capture CO 2 at high efficiency (> 90%) with very high CO 2 loading (> 10 wt.%), require less than 2 GJ/tonne for solvent regeneration, and produce a CO2 stream at high pressure with a purity > 95 vol.%. This 45-month MSP development program was designed to conduct (1) extensive test campaigns with different process flowsheet variants, and (2) detailed thermodynamic, kinetic, and process modeling. These tests and models were very important to identify any issues associated with the process in the early stages and then resolve them before moving into the next scale-up (> 1 MWe scale) testing. Such an approach reduces the risks associated with the process operability at large scales and provides capital and operating expenditure (CAPEX/OPEX) predictions with improved accuracies. Under the MSP development program at SRI, we performed an aggressive testing campaign with individual subsystems as well as integrated CO 2 capture and regeneration system to identify the best operating conditions. The project was carried out in two budget periods (BP1 & BP2).

20 FOSSIL-FUELED POWER PLANTS↗

Advances in plasma–wall interaction control for H-mode operation over 100 s with ITER-like tungsten divertor on EAST

A total power injection up to 0.3 GJ has been achieved in EAST long pulse H-mode operation of 101.2 s with an ITER-like water-cooled tungsten (W) mono-block divertor, which has steady-state power exhaust capability of 10 MWm –2 . The peak temperature of W target saturated at 12 s to the value T ~ 500 °C with a heat flux ~3.3 MW m –2 being maintained during the discharge. By tailoring the 3D divertor plasma footprint through edge magnetic topology change, the heat load was broadly dispersed and thus peak heat flux and W sputtering were well controlled. Active feedback control of H-mode detachment with D 2 fuelling or divertor impurity seeding has been achieved successfully, with excellent compatibility with the core plasma performance. Active feedback control of radiative power utilizing neon seeding was achieved with f rad = 18%–41% in H-mode operation, exhibiting potential for heat flux reduction with divertor and edge radiation. This has been further demonstrated in DIII-D high β P H-mode scenario within the joint DIII-D/EAST experiment using impurity seeding from the divertor volume. Steady-state particle control and impurity exhaust has been achieved for long pulse H-mode operation over 100 s with the W divertor by leveraging the effect of drifts and optimized divertor configuration, coupled with strong pumping and extensive wall conditioning. Methods toward the reduction of divertor W sourcing, which is of crucial importance for a metal-wall tokamak, are also explored. These advances provide vital experimental information on favourable core-edge integration for high power, long-pulse H-mode operation in EAST, ITER and CFETR.

43 PARTICLE ACCELERATORS↗

Drying of a Fully Saturated Porous Medium With Excess Water Layers: A Numerical Study

Abstract Drying of moist porous media can be very energy inefficient. For example, in the pulp and paper industry, paper drying consumes more than two-thirds of the total energy used in paper machines. Novel drying technologies can decrease the energy used for drying and lessen the manufacturing processes' carbon footprint. Developing next-generation drying technologies to dry moist porous media may require an understanding of removing moisture from a fully saturated porous material with excess water. This paper provides a fundamental understanding of heat and mass transfer in a fully saturated porous medium with excess water. This is relevant, for example, in drying tissue as well as pulp or paper for the purpose of thermal insulation where pressing is preferred to be avoided to overcome the reduction in the sheet thickness. For this purpose, a theoretical drying model is developed where the porous medium corresponds to paper and is assumed to be sandwiched between two excess-water layers (bottom and top). The conjugate model consists of energy and mass conservation equations for each layer. The model is validated with corresponding experimental data. In the model, the thickness of each water layer is calculated as a function of drying time based on local temperature and total moisture content. The numerical model is transient and one-dimensional in space (i.e., in the thickness direction). This paper demonstrates the governing equations, boundary conditions, and results when the saturated porous medium with water layers is heated from one side. Moisture and temperature profiles are estimated in the thickness direction of the porous medium as it dries.

Engineering↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility Evaluation and Retrofit Plan for Cold Crucible Induction Melter Deployment in the Defense Waste Processing Facility at Savannah River Site

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 kHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 deg. C to 200 deg. C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 deg. C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National-scale impacts on wind energy production under curtailment scenarios to reduce bat fatalities

Wind energy often plays a major role in meeting renewable energy policy objectives; however, increased deployment can raise concerns regarding the impacts of wind plants on certain wildlife. Particularly, estimates suggest hundreds of thousands of bat fatalities occur annually at wind plants across North America, with potential implications for the viability of several bat species. One approach to reducing bat fatalities is shutting down (or curtailing) turbines when bats are most at risk, such as at night during relatively low wind speed periods throughout summer and early autumn. While curtailment has consistently been shown to reduce bat fatalities, the lost power production reduces revenues for wind plants. This study conducted simulations with a range of curtailment scenarios across the contiguous United States to examine sensitivities of annual energy production (AEP) loss and potential impacts on economic metrics for future wind energy deployment. We found that AEP reduction can vary across the country from less than 1% to more than 10% for different curtailment scenarios. From an estimated 2891 gigawatts (GW) of simulated economically viable wind capacity (measured by a positive net present value), we found the mid curtailment scenario (6.0 m/s wind speed cut-in from July 1 through October 31) reduced the quantity of economic wind capacity by 274 GW or 9.5%. Our results indicate that high levels of curtailment could substantially reduce the future footprint of financially viable wind energy. In this context, future work that illuminates cost-effective strategies to minimize curtailment while reducing bat fatalities would be of value.

17 WIND ENERGY↗

CORE-BFS: Communication-Optimized REctangular-partitioned BFS Achieving 160.845 TeraTEPS on Frontier Supercomputer

Distributed Breadth-First Search (BFS) is fundamental to many large-scale graph applications, but its performance on parallel systems is often limited by high communication overhead. This paper presents CORE-BFS, an extremely scalable GPU-based BFS implementation that introduces a unique rectangular 2D partitioning-based design for Frontier supercomputer. To further improve performance, we propose four key optimizations: (1) Rectangular 2D-partition specific data formats that use two compressed row and one compressed column status array bitmaps combined with a Double Compressed Sparse Row (DCSR) format per partition, reducing memory footprint and inter-rank traffic; (2) Adaptive frontier & communication strategy that unifies top-down and bottom-up traversal on the rectangular layout, uses lazy synchronization in top-down levels, and switches variants based on frontier size to minimize communication overhead; (3) Frontier-split degree-aware update that maps frontier vertices to thread-centric, wavefront-centric, and block-centric kernels based on their degree to improve GPU utilization and memory coalescing; (4) Row-reduction pipeline that overlaps bottom-up adjacency list processing with row-wise bitmap reduction to hide inter-rank latency. Together, these techniques increase parallelism while reducing memory and communication overhead. On the Graph500 benchmark, CORE - BFS scales up to 9,248 Frontier nodes with scale-42 graphs and reaches 160.845 TTEPS, delivering a 5.42 × speedup over our previous Frontier implementation.

Yang, Haoshen [Rutgers University]↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE - 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined Joule heated melters. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed Joule Heated Melter, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations.

36 MATERIALS SCIENCE↗