Search NASA⌕ Search

SEARCH · Search NASA

Results for “FORENSIC SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Resolving Mixtures of Soot Characterized by SP-AMS Spectra Using a Latent Dirichlet Allocation Model

Soot produced by detonation or combustion events exhibits different chemical properties depending on the fuel, device construction, and environmental conditions in which the event occurs. These properties can be useful for defining relevant signatures for probabilistically identifying the different types of events that occurred, based on the soot that is produced from these events. However, it is rare to observe samples of soot from a detonation or combustion that are not contaminated by outside particles. In this paper, we present a method for resolving mixtures of soot to determine the contributions of sources that may be present in samples of recovered soot. We use Latent Dirichlet Allocation to describe the generative process for a sample of recovered soot, and use Variational Bayesian Inference to learn about the parameters associated with the generative model. We demonstrate the utility of this method by considering real samples of mixtures of soot under various frameworks to show that the model is able to identify the different components present in a sample of soot as well as their mixing proportions.

54 ENVIRONMENTAL SCIENCES↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Hygrothermal Modeling to Resolve Practical Low-Slope Roofing Issues

Within building envelope science, the use of tools to model performance of the building envelope has evolved, and designers and scientists today have a myriad of tools available. Hygrothermal modeling is one such tool and, when used correctly, offers designers and forensic investigators important information about the movement of moisture within the building envelope. This traditional use of hygrothermal modeling is maturing as models are validated with field experience, creating a confidence in the modeling tools and their predictive capabilities. Based on this confidence, application of hygrothermal modeling to a more practical application is an evolution whose time has arrived. With changes in materials and methods, the performance of roofing systems can often times no longer be based on experience alone. Roofing contractors have been confounded by the unexplained and unplanned-for presence of moisture in roofing systems. Although hygrothermal modeling can be used to explain where the moisture came from, we propose that it should be used to prevent its occurrence. Unfortunately, more than 70 % of the roofing market is in reroofing, and oftentimes, a designer is not engaged in the roofing system design. Without the expertise of a designer and given that hygrothermal modeling is not well understood by the roofing industry, its adoption as a tool that can prevent problems has not been widely seen. This paper presents an extensive summary of hygrothermal modeling performed for roofing systems and then shows how the modeling can be used to create simple resources for roofing contractors to reduce the potential for moisture condensation at critical locations within a roofing system. The systems modeled have shown a propensity for moisture accumulation, and the use of hygrothermal modeling to eliminate these problems is a practical application of a building science tool that can greatly improve the durability of roofing systems.

Desjarlais, Andre Omer↗

Digital droplet multiple displacement amplification (ddMDA) for whole genome sequencing of limited DNA samples

Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently, the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrasound assisted sonochemically engineered effective red luminescent labeling agent for high resolution visualization of latent fingerprints

Highlights: • BaTiO{sub 3}:Eu{sup 3+} NPs were prepared by facile bio-template assisted sonochemical route. • The obtained samples displayed superstructures of various regular morphological shapes. • The optimized product was used for forensic and anti-counterfeiting applications. • CIE, CCT studies indicate the present phosphor was highly useful in LED’s. - Abstract: Nanoscience and technology finds wide range of benefits in the area of surface based science due to its nano size and high surface area. This offers new potentials in surface-based science comprising latent fingerprint (LFP) and to develop luminescent ink for anti-counterfeiting applications. Due to high backward hindrance, low sensitivity, complicated setup, and poor universality of traditionally developed techniques were main drawbacks for the visualization of LFPs. To overcome these problems, we explored the superstructures (SS) of europium ions doped BaTiO{sub 3} nanophosphors (NPs) prepared via sonochemical route with bio-template as surfactant for the detection of LFPs and as an anti-counterfeiting ink. The morphologies of SS were highly dependent on the concentration of Aloe vera (A.V.) gel as well as ultrasound irradiation time. The obtained SS displayed pure red emission which corresponds to the {sup 5}D{sub 0} → {sup 7}F{sub J} transitions of Eu{sup 3+} ions under UV light. The results clearly evident that the optimized BaTiO{sub 3}:Eu{sup 3+} NPs will create a new prospect for research in LFPs visualization and anti-counterfeiting technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Activity Microscopic Nuclear-Sourced Particles to Investigate Nuclear Release Scenarios - 18026

Advances in microscopy and materials analysis have allowed for the study of materials at resolutions not previously attainable a decade ago. Such information extends to not only their existence, but also their composition, the likely source term and if applicable, their short or long-term environmental stability. This work describes the analysis undertaken on the larger 'ejecta' type of particulate collected following the INES Level 7 incident at the Fukushima Daiichi Nuclear Power Plant in March 2011. However, the methods and procedures employed during this work, on material with enormously contrasting characteristics, have far wider applications within nuclear forensics, safeguards, security and material compliance. Resulting from the analysis of micron-scale 'atmospheric' material in previous works have been able to derive information relating to the emission and subsequent transportation characteristics of the release event, as well as determining the local-scale impacts of this radioactive fallout. This analysis of the larger-scale (100's of micron) 'ejecta' material, collected from closer to the plant, has been able to reveal details pertaining to the specific in-reactor conditions at the time of the release as well as the nature of the explosion events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Measurements of beta-delayed gamma-ray spectra following 14-MeV neutron-induced fissions of 232 Th, 238 U, and 237 Np were conducted at Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron. Spectra were collected for times ranging from 1 minute to 14 hours after irradiation. Lastly, intensity ratios of gamma-ray lines were extracted from the data that allow identification of the fissioning isotope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operational Stewardship Program Development and Execution Lawrence Livermore National Laboratory - 16353

As LLNL carries out its national security missions, the Laboratory strives to ensure its facilities portfolio meets the latest technologies and enables infrastructure needs. Among the identified Science, Technology and Engineering (ST and E) areas that constitute strategic priorities, state-of-the-art facilities are needed to allow LLNL to draw collaborative partners required to advance capabilities and provide the requisite world-class forensics support in nuclear threat countermeasures. Efficient utilization of existing facilities presents a unique challenge given the advanced age and unique mission design of many of LLNL's facilities. A strategy developed in 2007 sought to focus key reinvestments into enduring facilities while strategically migrating personnel and operations out of past mission facilities with the intent of closure and final Transition and Disposition (T and D). At the time, LLNL lacked processes or procedures that met the continually changing facility mission and objectives needs. A comprehensive approach was needed to provide the framework to guide decisions along the entire life cycle of a project and/or facility. The development of an Operational Stewardship Program began in 2012 which outlines the process, and roles and responsibilities, in changing facility status to ensure good stewardship, accountability, and management and utilization of facilities. Further emphasizing LLNL forward actions, the 2015 NNSA sponsored Excess Contaminated Facilities Working Group charted the development of a common, Department-wide methodology for determining costs and risks. In December 2015, the complete Operational Stewardship Program was approved for implementation by LLNL senior management. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chemical Attribution of Fentanyl Using Multivariate Statistical Analysis of Orthogonal Mass Spectral Data

Attribution of the origin of an illicit drug relies on identification of compounds indicative of its clandestine production and is a key component of many modern forensic investigations. Here, the results of these studies can yield detailed information on method of manufacture, starting material source, and final product, all critical forensic evidence. In the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic fentanyl, N-(1-phenylethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Six synthesis methods, all previously published fentanyl synthetic routes or hybrid versions thereof, were studied in an effort to identify and classify route-specific signatures. A total of 160 distinct compounds and inorganic species were identified using gas and liquid chromatographies combined with mass spectrometric methods (gas chromatography/mass spectrometry (GC/MS) and liquid chromatography–tandem mass spectrometry-time of-flight (LC–MS/MS-TOF)) in conjunction with inductively coupled plasma mass spectrometry (ICPMS). The complexity of the resultant data matrix urged the use of multivariate statistical analysis. Using partial least-squares-discriminant analysis (PLS-DA), 87 route-specific CAS were classified and a statistical model capable of predicting the method of fentanyl synthesis was validated and tested against CAS profiles from crude fentanyl products deposited and later extracted from two operationally relevant surfaces: stainless steel and vinyl tile. Finally, this work provides the most detailed fentanyl CAS investigation to date by using orthogonal mass spectral data to identify CAS of forensic significance for illicit drug detection, profiling, and attribution.

36 MATERIALS SCIENCE↗

Routine Beryllium-10 analysis from post-detonation debris and geologic materials [Slides]

Beryllium (Be) isotope measurements provide insight into weapon design, yield, etc. Sample preparation nor measurement capability currently existed at LANL. Potential capability directly benefits nuclear forensics venture. PI Goehring has nearly 20 years of Be chemistry experience, including method implementation with difficult samples.

07 ISOTOPE AND RADIATION SOURCES↗

Science and Technology Review (March 2014)

Over the past few years, Lawrence Livermore has experienced a surge of innovation in radiochemistry—the science of generating, identifying, isolating, and characterizing the radioactive isotopes of chemical elements. For example, Livermore researchers have developed a technique for producing double-sided target foils and built a target surface mapping tool, which increased the productivity of stockpile stewardship experiments. Radiochemists are also using the Laboratory’s particle accelerator to measure nuclear reaction products for reactor safety and nuclear forensics research. Another Livermore team is making synthetic nuclear debris samples with ingredients that more closely match debris from a real explosion for use in isotope identification exercises. Researchers are also refining the chemicals and protocols required to perform wet-chemistry experiments on transactinides, shortlived heavy elements such as flerovium and livermorium. A collaboration with two universities is developing a portable, automated system that can quickly capture, prepare, and chemically test radioisotopes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗