Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOULING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Effect of Fatty Acids to Protect Forward Osmosis Membranes from Damage

NASA has conducted research and development on forward osmosis (FO) membranes for wastewater reclamation in space since 1993. The lessons learned during operation of the International Space Station and FO based technologies on the ground taught us that reliability is a key limitation. Membranes are susceptible to organic fouling, oxidation and calcium scaling, and these factors tend to damage the membrane reducing their operating life and performance. The development of a Synthetic Biological Membrane (SBM), a membrane that mimics naturally occurring biological processes, will mitigate membrane damage and improve reliability. The SBM is a lipid-based membrane with a protective fatty acid layer configured for use in a FO water purification system. In this configuration, the protective layer on the surface of the lipid membrane is composed of fatty acids (FA). The FA interact with the chemicals found in the wastewater feed, and protect the membrane from damage. In this study, we conducted preliminary experiments to determine the feasibility of using fatty acids to alleviate damage from calcium scaling, oxidation and organic fouling.

Romero Mangado, Jaione↗

Reduction of Wind Tunnel Contamination During Flow Visualization Experiments Using Polystyrene Microspheres

Evaluation of novel methods and materials for seeding tracer particles for particle image velocimetry (PIV) was carried out in the Basic Aerodynamic Research Tunnel (BART) at NASA’s Langley Research Center (LaRC). Seeding of polystyrene latex microspheres (PSLs) from ethanol/water suspensions and from the dry state was carried out using custom built seeders. PIV data generated using the novel methods were found to be in general agreement with data collected using the current seeding methods. Techniques for assessing PSL fouling of wind tunnel surfaces were identified and refined. Initial results suggest that dry seeding PSLs may allow comparable data quality to wet seeding while reducing wind tunnel screen fouling. Results also indicate that further developments to the dry seeding system should focus on increasing single particle flux into the wind tunnel. Modifications to PSLs and seeding equipment to achieve this have been identified and are discussed.

Schmitz, Russell C.↗

Considerations on Electrolytic Conductivity Measurement for Monitoring of Ionic Silver Biocide Dosing

NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.

silver↗

Potential Biofilm Control Strategies for Extended Spaceflight Missions

Biofilms, surface-adherent microbial communities, are associated with microbial fouling and corrosion in terrestrial water-distribution systems. Biofilms are also present in human spaceflight, particularly in the Water Recovery System (WRS) on the International Space Station (ISS). The WRS is comprised of the Urine Processor Assembly (UPA) and the Water Processor Assembly (WPA) which together recycles wastewater from human urine and recovered humidity from the ISS atmosphere. These wastewaters and various process streams are continually inoculated with microorganisms primarily arising from the space crew microbiome. Biofilm-related fouling has been encountered and addressed in spacecraft in low Earth orbit, including ISS and the Russian Mir Space Station. However, planned future missions beyond low Earth orbit to the Moon and Mars present additional challenges, as resupplying spare parts or support materials would be impractical and the mission timeline would be in the order of years in the case of a mission to Mars. In addition, future missions are expected to include a period of dormancy in which the WRS would be unused for an extended duration. The concepts developed in this review arose from a workshop including NASA personnel and representatives with biofilm expertise from a wide range of industrial and academic backgrounds. Here, we address current strategies that are employed on Earth for biofilm control, including antifouling coatings and biocides and mechanisms for mitigating biofilm growth and damage. These ideas are presented in the context of their applicability to spaceflight and identify proposed new topics of biofilm control that need to be addressed in order to facilitate future extended, crewed, spaceflight missions.

Luis Zea↗

Methods for sulfate removal in liquid-phase catalytic hydrothermal gasification of biomass

Processing of wet biomass feedstock by liquid-phase catalytic hydrothermal gasification must address catalyst fouling and poisoning. One solution can involve heating the wet biomass with a heating unit to a pre-treatment temperature sufficient for organic constituents in the feedstock to decompose, for precipitates of inorganic wastes to form, for preheating the wet feedstock in preparation for subsequent removal of soluble sulfate contaminants, or combinations thereof. Processing further includes reacting the soluble sulfate contaminants with cations present in the feedstock material to yield a sulfate-containing precipitate and separating the inorganic precipitates and/or the sulfate-containing precipitates out of the wet feedstock. Having removed much of the inorganic wastes and the sulfate contaminants that can cause poisoning and fouling, the wet biomass feedstock can be exposed to the heterogenous catalyst for gasification.

09 BIOMASS FUELS↗

Methods for sulfate removal in liquid-phase catalytic hydrothermal gasification of biomass

Processing of wet biomass feedstock by liquid-phase catalytic hydrothermal gasification must address catalyst fouling and poisoning. One solution can involve heating the wet biomass with a heating unit to a pre-treatment temperature sufficient for organic constituents in the feedstock to decompose, for precipitates of inorganic wastes to form, for preheating the wet feedstock in preparation for subsequent removal of soluble sulfate contaminants, or combinations thereof. Processing further includes reacting the soluble sulfate contaminants with cations present in the feedstock material to yield a sulfate-containing precipitate and separating the inorganic precipitates and/or the sulfate-containing precipitates out of the wet feedstock. Having removed much of the inorganic wastes and the sulfate contaminants that can cause poisoning and fouling, the wet biomass feedstock can be exposed to the heterogeneous catalyst for gasification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods and apparatus for catalytic hydrothermal gasification of biomass

Continuous processing of wet biomass feedstock by catalytic hydrothermal gasification must address catalyst fouling and poisoning. One solution can involve heating the wet biomass with a heating unit to a temperature sufficient for organic constituents in the feedstock to decompose, for precipitates of inorganic wastes to form, for preheating the wet feedstock in preparation for subsequent separation of sulfur contaminants, or combinations thereof. Treatment further includes separating the precipitates out of the wet feedstock, removing sulfur contaminants, or both using a solids separation unit and a sulfur separation unit, respectively. Having removed much of the inorganic wastes and the sulfur that can cause poisoning and fouling, the wet biomass feedstock can be exposed to the heterogeneous catalyst for gasification.

09 BIOMASS FUELS↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio – 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were “right-sized” at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented.

54 ENVIRONMENTAL SCIENCES↗

Method for condensing a CO2 vapor stream beyond the frost point

A method for cryogenic cooling without fouling is disclosed. The method comprises providing a first cryogenic liquid saturated with a dissolved gas; expanding the first cryogenic liquid into a separation vessel, separating into a vapor, a second cryogenic liquid, and a first solid; drawing the vapor into a heat exchanger and the second cryogenic liquid and the first solid out of the separation vessel; cooling the vapor against a coolant through the heat exchanger, causing the vapor to form a third cryogenic liquid and a second solid, the second solid dissolving in the third cryogenic liquid; and combining the second cryogenic liquid and the first solid with the third cryogenic liquid, producing a final cooled slurry. In this manner, the cryogenic cooling is accomplished without fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio - 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were 'right-sized' at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Membrane Filtration with Liquids: A Global Approach with Prior Successes, New Developments and Unresolved Challenges

After 70 years, modern pressure-driven polymer membrane processes with liquids are mature and accepted in many industries due to their good performance, ease of scale-up, low energy consumption, modular compact construction, and low operating costs compared with thermal systems. Successful isothermal operation of synthetic membranes with liquids requires consideration of three critical aspects or “legs” in order of relevance: selectivity, capacity (i.e. permeation flow rate per unit area) and transport of mass and momentum comprising concentration polarization (CP) and fouling (F). Major challenges remain with respect to increasing selectivity and controlling mass transport in, to and away from membranes. Thus, prediction and control of membrane morphology and a deep understanding of the mechanism of dissolved and suspended solute transport near and in the membrane (i.e. diffusional and convective mass transport) is essential. Here, we focus on materials development to address the relatively poor selectivity of liquid membrane filtration with polymers and discuss the critical aspects of transport limitations. Machine learning could help optimize membrane structure design and transport conditions for improved membrane filtration performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass spectrometric investigations on the release of inorganic species during gasification and combustion of German hard coals

Na-, K-, Cl-, and S-species released during thermal conversion of coal can cause several problems such as fouling, slagging and corrosion, especially in gas turbines and heat recovery systems. To reduce this problems an enhanced understanding of the underlying release mechanisms for Na-, K-, Cl-, and S-species is needed. Therefore, basic investigations have been performed in an atmospheric lab-scale tube furnace at 1400 C under gasification and combustion conditions. Hot gas analysis has been carried out by molecular beam mass spectrometry. The release of H{sub 2}S, HCl, K+, NaCl, COS, and SO{sub 2} has been qualitative and quantitative analysed and correlated with the coal composition. The results show a strong dependence of coal composition and reaction atmosphere on the release of Na-, K-, Cl-, and S-species. Additionally, thermodynamic equilibrium calculations with the software package FactSage 5.4.1 have been undertaken for comparison with the experimental results. (author)

01 COAL, LIGNITE, AND PEAT↗

Analysis of backwash settings to maximize net water production in an engineering-scale ultrafiltration system for water reuse

Ultrafiltration (UF) has been widely utilized as water pretreatment for different applications especially in water reuse. The UF system operation is characterized by a filtration phase, where particles accumulate on the membrane surface resulting in an increase in the transmembrane pressure (TMP) and a cleaning phase, where foulants are removed through cleaning cycles including physical backwash and chemical-enhanced backwash (CEB). In this study, data from an engineering-scale UF system treating reclaimed wastewater were used to assess the impact of backwashing on the filtration process. TMP backwash trigger, backwash duration, and CEB frequency were purposely varied for a cycle-by-cycle investigation on the net water production, water recovery, initial operating TMP, and filtration cycle duration. As the TMP backwash trigger was varied between 62 and 145kPa, the maximum net water production (63 m 3 /d) was achieved at 103kPa and water recovery remained relatively constant at approximately 92%. Backwash durations of 45, 65, and 85s were performed where both net water production and water recovery yielded similar results (~63 m 3 /d and ~ 91%) compared with 103kPa TMP backwash trigger. The CEB frequency was also lowered from one every three backwashes (1/3) to 1/6 and 1/12 and resulted in decreased net water production and water recovery while the initial TMP increased. Interestingly, the total number of CEBs remained approximately constant regardless of their frequency. In conclusion, results suggest that CEB is an important fouling control process to maximize water production.

42 ENGINEERING↗

Thermoresponsive antifouling ultrafiltration membranes from mesophase templating

Nanostructured polymers synthesized by lyotropic liquid crystal (LLC) templates with normal hexagonal (H 1 ) structure exhibit a 3D-continuous transport path, which makes them ideal for membrane separation application. Incorporating additional functionality, especially stimuli-responsiveness, in such an ordered structure provides even more application opportunities. Here, in this work, we present the first successful synthesis of H 1 -structured thermoresponsive ultrafiltration (UF) membranes via LLC templating. The membrane contains thermoresponsive Pluronic P84 diacrylate (P84DA) which not only acts as the monomer and structure-directing amphiphile, but also enables the pore size change with temperature. Experimental studies reveal that the swelling capacity of H 1 -templated polymer as well as permeability and selectivity of the obtained membrane can be altered by changing the temperature. Increasing the temperature from 25 to 45 °C increases the normalized flux from 28 to 68 L m -2 h -1 μm and molecular weight cut-off (MWCO) from 2200 to 3900 Da. Furthermore, the membrane shows an outstanding fouling resistance against different solutes.

36 MATERIALS SCIENCE↗

Formation of deposits on the surfaces of superheaters and economisers of MSW incinerator plants

Highlights: Black-Right-Pointing-Pointer Composition of deposits depends on the temperature profile and boiler geometry. Black-Right-Pointing-Pointer The mineralogy of deposits defines critical and uncritical zones in the boiler. Black-Right-Pointing-Pointer Critical zones in boilers can be characterised by a classification systems. Black-Right-Pointing-Pointer Specific measures to enhance energy efficiency can be defined. - Abstract: Mineralogical and chemical investigations of deposits from superheaters and economisers from a MSWI plant in Mannheim, Germany, lead to a classification system which provides information about the most critical parameters leading to fouling and corrosion. With the help of this classification system parameters like the geometry of boilers and the waste input can be changed in order to prolong run times between revisions and enhance energy efficiency of MSWI plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigation of wood combustion in a fixed bed with hot air

Highlights: • Upward combustion is a new combustion concept with ignition by hot primary air. • Upward combustion has three stages: short drying, rapid devolatilization and char combustion. • Variation of fuel moisture and inert content have little influence on the combustion. • Experimental comparison between conventional and upward combustion is presented. - Abstract: Waste combustion on a grate with energy recovery is an important pillar of municipal solid waste (MSW) management in the Netherlands. In MSW incinerators fresh waste stacked on a grate enters the combustion chamber, heats up by radiation from the flame above the layer and ignition occurs. Typically, the reaction zone starts at the top of the waste layer and propagates downwards, producing heat for drying and devolatilization of the fresh waste below it until the ignition front reaches the grate. The control of this process is mainly based on empiricism. MSW is a highly inhomogeneous fuel with continuous fluctuating moisture content, heating value and chemical composition. The resulting process fluctuations may cause process control difficulties, fouling and corrosion issues, extra maintenance, and unplanned stops. In the new concept the fuel layer is ignited by means of preheated air (T > 220 °C) from below without any external ignition source. As a result a combustion front will be formed close to the grate and will propagate upwards. That is why this approach is denoted by upward combustion. Experimental research has been carried out in a batch reactor with height of 4.55 m, an inner diameter of 200 mm and a fuel layer height up to 1 m. Due to a high quality two-layer insulation adiabatic conditions can be assumed. The primary air can be preheated up to 350 °C, and the secondary air is distributed via nozzles above the waste layer. During the experiments, temperatures along the height of the reactor, gas composition and total weight decrease are continuously monitored. The influence of the primary air speed, fuel moisture and inert content on the combustion characteristics (ignition rate, combustion rate, ignition front speed and temperature of the reaction zone) is evaluated. The upward combustion concept decouples the drying, devolatilization and burnout phase. In this way the moisture and inert content of the waste have almost no influence on the combustion process. In this paper an experimental comparison between conventional and reversed combustion is presented.

09 BIOMASS FUELS↗