Independent Orbiter Assessment (IOA): Analysis of the active thermal control subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical (PCIs) items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results corresponding to the Orbiter Active Thermal Control Subsystem (ATCS) are documented. The major purpose of the ATCS is to remove the heat, generated during normal Shuttle operations from the Orbiter systems and subsystems. The four major components of the ATCS contributing to the heat removal are: Freon Coolant Loops; Radiator and Flow Control Assembly; Flash Evaporator System; and Ammonia Boiler System. In order to perform the analysis, the IOA process utilized available ATCS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 310 failure modes analyzed, 101 were determined to be PCIs.

Sinclair, S. K.↗

Tank Pressure Control Experiment on the Space Shuttle

The tank pressure control experiment is a demonstration of NASA intent to develop new technology for low-gravity management of the cryogenic fluids that will be required for future space systems. The experiment will use freon as the test fluid to measure the effects of jet-induced fluid mixing on storage tank pressure and will produce data on low-gravity mixing processes critical to the design of on-orbit cryogenic storage and resupply systems. Basic data on fluid motion and thermodynamics in low gravity is limited, but such data is critical to the development of space transfer vehicles and spacecraft resupply facilities. An in-space experiment is needed to obtain reliable data on fluid mixing and pressure control because none of the available microgravity test facilities provide a low enough gravity level for a sufficient duration to duplicate in-space flow patterns and thermal processes. Normal gravity tests do not represent the fluid behavior properly; drop-tower tests are limited in length of time available; aircraft low-gravity tests cannot provide the steady near-zero gravity level and long duration needed to study the subtle processes expected in space.

Source record↗

Low flow vortex shedding flowmeter

The purpose was to continue a development project on a no moving parts vortex shedding flowmeter used for flow measurement of hypergols. The project involved the design and construction of a test loop to evaluate the meter for flow of Freon which simulates the hypergol fluids. Results were obtained on the output frequency characteristics of the flow meter as a function of flow rate. A family of flow meters for larger size lines and ranges of flow was sized based on the results of the tested meter.

Waugaman, Charles J.↗

An Auger electron spectroscopy study of surface-preparation contaminants

There are many cleaning techniques that are presently being employed for surface preparation of materials that are subsequently exposed to ultrahigh vacuum (UHV). Unfortunately, there are virtually no comparative measurements which establish the residual contaminant level of each method. In this report, eleven different cleaning methods, ranging from only detergent cleaning to electrochemical polishing, were applied to identical samples of 347 stainless steel. Two surface conditions, a standard machined surface and a mechanically polished surface, were studied. Auger electron spectroscopy (AES) within a UHV environment was then used to detect the types of contaminants and the magnitudes found on the sample surfaces. It was found that the electrochemical polishing gave the least contaminated surface of all metals studied and that mechanically polished surfaces were significantly cleaner than the as-machined surfaces for any given cleaning method. Furthermore, it was also found that the residual contaminations left by methanol, ethanol, isopropyl alcohol, acetone, and freon finishing rinses are almost the same.

Wu, D.↗

Analysis of a six-component, flow-through, strain-gage, force balance used for hypersonic wind tunnel models with scramjet exhaust flow simulation

The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.

Kniskern, Marc W.↗

Flow boiling with enhancement devices for cold plate coolant channel design

The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.

Boyd, Ronald D., Sr.↗

Ceramic heat pipe wick

A wick for use in a capillary loop pump heat pipe is disclosed. The wick material is an essentially uniformly porous, permeable, open-cell, silicon dioxide/aluminum oxide inorganic ceramic foam having a silica fiber ratio, by weight, of about 78 to 22, respectively, a density of 6 lbs/cu ft, and an average pore size of less than 5 microns. A representative material having these characteristics is Lockheed Missile and Space Company, Inc.'s HTP 6-22. This material is fully compatible with the freons and anhydrous ammonia and allows for the use of these very efficient working fluids, and others, in capillary loops.

Seidenberg, Benjamin↗

Ground evaluation of seeding an in-flight wingtip vortex using infrared imaging flow visualization technique

An experimental simulation of an in-flight wingtip vortical flow visualization technique uses infrared imaging to observe strong and concentrated vortices. This experiment is phase 1 of a two-phase infrared evaluation program. The system includes a vortex generator (model 320 Vortec Vortex Tube) which generates the required vortex. The mouth of the unit is mounted close to the free end of a half-inch diameter, sixteen and a half foot long stainless steel tubing (sized after tubing currently installed in the wings of an experimental Beechcraft Sundowner 180 aircraft). Dichloro difluoromethane (Freon-12) is entrained into the generated vortex. A breakdown of the vortices is indicated by the rapid diffusion and the resulting pattern is tracked using the infrared imager and video systems. Flow rates (volume and mass) are estimated at the laboratory and proposed flight conditions. The nominal flight altitude is expected to be 2500 feet.

Akinyanju, Ted↗

Neonlike Ar and Cl 3p-3s emission from a theta-pinch plasma

Time-resolved extreme-UV emission from sixteen 3p-3s transitions, some of the type in which lasing has been demonstrated in heavier elements, is measured for neonlike Ar(8+) and Cl(7+). These observations are made on a hydrogen theta-pinch plasma with a 5 pct admixture of argon or freon (for Cl). Fourteen 3d-3p spectral lines are also detected. The measured intensities are compared to theoretical predictions. There is no evidence of anomalously intense lines originating on 2p5 3p J = 2 upper levels compared to J = 0, as observed in gain experiments.

Elton, R. C.↗

Reduction of blade-vortex interaction noise through higher harmonic pitch control

An acoustics test using an aeroelastically scaled rotor was conducted to examine the effectiveness of higher harmonic blade pitch control for the reduction of impulsive blade-vortex interaction (BVI) noise. A four-bladed, 110 in. diameter, articulated rotor model was tested in a heavy gas (Freon-12) medium in Langley's Transonic Dynamics Tunnel. Noise and vibration measurements were made for a range of matched flight conditions, where prescribed (open-loop) higher harmonic pitch was superimposed on the normal (baseline) collective and cyclic trim pitch. For the inflow-microphone noise measurements, advantage was taken of the reverberance in the hard walled tunnel by using a sound power determination approach. Initial findings from on-line data processing for three of the test microphones are reported for a 4/rev (4P) collective pitch control for a range of input amplitudes and phases. By comparing these results to corresponding baseline (no control) conditions, significant noise reductions (4 to 5 dB) were found for low-speed descent conditions, where helicopter BVI noise is most intense. For other rotor flight conditions, the overall noise was found to increase. All cases show increased vibration levels.

Brooks, Thomas F.↗

Internal flow measurements of the SSME fuel preburner injector element using real time neutron radiography

Due to observations of unsteady flow in the Space Shuttle Main Engine fuel preburner injector element, several flow studies have been performed. Real time neutron radiography tests were recently completed. This technique provided real time images of MiL-c-7024 and Freon-22 flow through an aluminum liquid oxygen post model at three back pressures (0, 150, and 545 psig) and pressure drops up to 1000 psid. Separated flow appeared only while operating at back pressures of 0 and 150 psig. The behavior of separated flow was similar to that observed for water in a 3x acrylic model of the LOX post. On the average, separated flow appeared to reattach near the exit of the post when the ratio of pressure drop to supply pressure was about 0.75.

Lindsay, John T.↗

Analytical modelling of no-vent fill process

An analytical model called FILL is presented which represents the first step in attaining the capability for no-vent fill of cryogens in space. The model's analytical structure is described, including the equations used to calculate transient thermodynamic behavior in different regions of the tank. The code predictions are compared with data from recent no-vent fill ground tests using Freon-114. The results are used to validate the FILL model to evaluate the viability of universal submerged jet theory in predicting system-level condensation effects.

Vaughan, David A.↗

Conceptual design of the subscale orbital fluid transfer experiment (SOFTE)

The Subscale Orbital Fluid Transfer Experiment is a planned space experiment with the objective of obtaining video and numerical data on fluid dynamics and thermal physics pertinent to on-orbit liquid acquisition and tank filling operations, particularly with cryogens. These data have significant application to space-based transportation systems, Space Station Freedom, and space defense systems. This paper presents the rationale for the experiment and a description of its design. The experiment will mount in two Get Away Special canisters that are connected to each other by an electrical umbilical. It involves transferring Freon 113 between two transparent plexiglass tanks. Axial and tangential no-vent fills will be done over a range of flow rates. The apparatus includes a screened-channel liquid acquisition device with plexiglass channels for examining vapor breakthrough and channel refill processes. Video cameras will monitor the transfer operations.

Jones, O. S.↗

Automatic control study of the icing research tunnel refrigeration system

The Icing Research Tunnel (IRT) at the NASA Lewis Research Center is a subsonic, closed-return atmospheric tunnel. The tunnel includes a heat exchanger and a refrigeration plant to achieve the desired air temperature and a spray system to generate the type of icing conditions that would be encountered by aircraft. At the present time, the tunnel air temperature is controlled by manual adjustment of freon refrigerant flow control valves. An upgrade of this facility calls for these control valves to be adjusted by an automatic controller. The digital computer simulation of the IRT refrigeration plant and the automatic controller that was used in the simulation are discussed.

Kieffer, Arthur W.↗

Low flow vortex shedding flowmeter for hypergolics/all media

A family of vortex shedding flowmeters for flow measurement of hypergols that requires a long term operation without removal from system lines was further developed. A family of vortex shedding flowmeters without moving parts was designed. The test loop to evaluate the meters for the Freon flow, which simulates the hypergolic fluids, was modified and reconstructed. Preliminary results were obtained on the output frequency characteristics of an 1/2 inch flowmeter as a function of the flow rate.

Thinh, Ngo↗

Iron mineralogy of a Hawaiian palagonitic soil with Mars-like spectral and magnetic properties

Visible and near-IR spectral data for some palagonitic soils from Mauna Kea, Hawaii, are similar to corresponding spectral data for Mars. It is important to understand the composition, distribution, and mineralogy of the ferric-bearing phases for the best spectral analogues because the correspondence in spectral properties implies that the nature of their ferric-bearing phases may be similar to those on Mars. In order to constrain interpretations of the Martian data, a variety of palagonitic soils should be studied in order to establish to what extent differences in their spectral data correspond to differences in the mineralogy of their ferric-bearing phases. Spectral (350-2100 nm), Mossbauer, magnetic, and some compositional data for one of a suite of Hawaiian palagonitic soils are presented. The soil (HWMK1) was collected below the biologically active zone from the sides of a gully cut at 9000 ft elevation on Mauna Kea. The soil was wet sieved with freon into seven size fractions less than 1 mm.

Morris, Richard V.↗

Forced convection and flow boiling with and without enhancement devices for top-side-heated horizontal channels

The effect of enhancement devices on flow boiling heat transfer in coolant channels, which are heated either from the top side or uniformly was studied. Studies are completed of the variations in the local (axial and circumferential) and mean heat transfer coefficients in horizontal, top-heated coolant channels with smooth walls and internal heat transfer enhancement devices. The working fluid is freon-11. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls or with both a twisted tape and spiral finned walls; (2) examine the effect of channel diameter (and the length-to-diameter aspect ratio) variations for the smooth wall channel; and (3) develop and improved data reduction analysis. The case of the top-heated, horizontal flow channel with smooth wall (1.37 cm inside diameter, and 122 cm heated length) was completed. The data were reduced using a preliminary analysis based on the heated hydraulic diameter. Preliminary examination of the local heat transfer coefficient variations indicated that there are significant axial and circumferential variations. However, it appears that the circumferential variation is more significant than the axial ones. In some cases, the circumferential variations were as much as a factor of ten. The axial variations rarely exceeded a factor of three.

Boyd, Ronald D., Sr.↗

Analysis of generic scramjet external nozzle flowfields employing simulant gases

Experimental and computational results are presented for a generic scramjet nozzle/afterbody model. Mixtures of argon and Freon were employed as simulant scramjet exhaust gases because they correctly model the inviscid simulation parameters of actual scramjet combustion products, allowing test and analysis at significantly reduced temperatures. Air was also employed as an exhaust gas to provide experimental and computational comparisons with simulant gas effects. Several computational aerodynamic analysis codes, employing different levels of theoretical modeling, were applied to compute solutions about the scramjet geometry. The solutions are compared with measured surface static and flowfield pitot pressure data taken in a Mach 6 freestream.

Tatum, Kenneth E.↗