Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Mode selection and tuning of single-frequency short-cavity VECSELs

Here, we report on mode selection and tuning properties of vertical-external-cavity surface-emitting lasers (VECSELs) containing coupled semiconductor and external cavities of total length less than 1 mm. Our goal is to create narrowlinewidth (<1MHz) single-frequency VECSELs that operate near 850 nm on a single longitudinal cavity resonance and tune versus temperature without mode hops. We have designed, fabricated, and measured VECSELs with external-cavity lengths ranging from 25 to 800 μm. Lastly, we compare simulated and measured coupled-cavity mode frequencies and discuss criteria for single mode selection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of low-frequency nonlinear currents in plasma by an ultrashort pulse of high-frequency radiation

A kinetic theory of low-frequency currents induced in plasma by an ultrashort high-frequency radiation pulse is developed. General expressions for the currents flowing along the propagation direction of the pulse and along the gradient of the field energy density are analyzed both analytically and numerically for pulse durations longer or shorter than or comparable with the electron collision time in plasma. It is demonstrated that the nonlinear current flowing along the gradient of the field energy density can be described correctly only when the modification of the isotropic part of the electron distribution function is taken into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field, frequency and temperature dependence of complex conductance of ultrathin La1.65Sr0.45CuO4/La2CuO4 films and the organic superconductors κ-(BEDT-TTF)2Cu[N(CN)2]Br

We used atomic-layer molecular beam epitaxy (ALL-MBE) to synthesize bilayer films of a cuprate metal (La1.65Sr0.45CuO4La1.65Sr0.45CuO4, LSCO) and a cuprate insulator (La2CuO4La2CuO4, LCO), in which interface superconductivity occurs in a layer that is just one-half unit cell thick. We have studied the magnetic field and temperature dependence of the complex sheet conductance, σ(ω)σ(ω), of these films, and compared them to κκ-(BEDT-TTF)2Cu[N(CN)2]Br2Cu[N(CN)2]Br single crystals. The magnetic field HH was applied both parallel and perpendicular to the 2D conducting layers. Experiments have been carried out at frequencies between 23 kHz and 50 MHz using either two-coil mutual inductance technique, or the LC resonators with spiral or rectangular coils. The real and the imaginary parts of the mutual-inductance M(T,ω)M(T,ω) between the coil and the sample were measured and converted to complex conductivity. For HH perpendicular to the conducting layers, we observed almost identical behavior in both films and κκ-Br single crystals: (i) the transition onset in the inductive response, L-1kLk-1(T) occurs at a temperature lower by 2 K than in Reσ(T)Reσ(T), (ii) this shift is almost constant with magnetic field up to 8 T; (iii) the vortex diffusion constant D(T)D(T) is exponential due to pinning of vortex cores. These results can be described by the extended dynamic theory of the Berezinski–Kosterlitz–Thouless (BKT) transition and dynamics of bound vortex–antivortex pairs with short separation lengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A plan to revitalize the domestic superconducting radio-frequency industry

Superconducting radio-frequency (SRF) cavities are essential building blocks of modern particle accelerators for scientific research, and they offer unique capabilities that could be transformative for commercial applications. Growth of the domestic SRF industry in North America has faced several challenges over the past decades, as most of the international demand for cavities was supplied by European vendors. This contribution provides a brief review of the domestic industrial vendor space, an outlook of the global demand for SRF cavities and an outline of the challenges leading to this supply chain deficiency. One of the main challenges towards establishing a robust domestic SRF industry has been the large uncertainty in the demand. Meanwhile, research and development activities to raise technical readiness of SRF accelerators for industrial use have continued and several potential markets are emerging that may offer a consistent and growing demand for SRF cavities. Finally, reasons and means of establishing and sustaining competitive domestic suppliers are described.

Accelerator Physics↗

On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this paper, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Finally and furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.

42 ENGINEERING↗

Escape conditioning and low-frequency whole-body vibration - The effects of frequency, amplitude, and controls for noise and activation.

Seven experiments are reported on low-frequency whole-body vibration and rats' escape conditioning in a modified Skinner box. In the first three studies, conditioning was observed but was independent of frequency. In experiment four, the number of escape responses was directly related to vibration amplitude. Experiment five was a control for vibration noise and noise termination; experiments six and seven studied vibration-induced activation. Noise termination did not produce conditioning. In experiment six, subjects made more responses when responding led to termination than when it did not. In experiment seven, subjects preferred a bar which terminated vibration to one which did not.

Wike, E. L.↗

The measurement of frequency and frequency stability of precision oscillators

The specification and performance of precision oscillators is discussed as a very important topic to the owners and users of these oscillators. This paper presents at the tutorial level some convenient methods of measuring the frequencies of precision oscillators -- giving advantages and disadvantages of these methods. Further it is shown that by processing the data from the frequency measurements in certain ways, one may be able to state more general characteristics of the oscillators being measured. The goal in this regard is to allow the comparisons of different manufacturers' specifications and more importantly to help assess whether these oscillators will meet the standard of performance the user may have in a particular application.

Allan, D. W.↗

A frequency-routed satellite system concept using multiple orthogonally-polarized beams for frequency reuse

The design concepts of a multibeam frequency-division multiplexed satellite system accessed by many moderately sized earth stations are outlined. In the system proposed here, traffic is routed from beam to beam through appropriate apportionment and filtering. Within a beam, the routing to particular users is achieved by conventional FDM. The optimum beam size, beam isolation, orthogonal polarization assignment to beams, the concept of beam groups yielding a simple transponder design, and the establishment of a frequency plan providing interference-free band assignments are discussed.

Rotholz, E.↗

Atomic frequency standards for ultra-high-frequency stability

The general features of the Hg-199(+) trapped-ion frequency standard are outlined and compared to other atomic frequency standards, especially the hydrogen maser. The points discussed are those which make the trapped Hg-199(+) standard attractive: high line Q, reduced sensitivity to external magnetic fields, and simplicity of state selection, among others.

Maleki, L.↗

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo↗

Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

Weissman, David E.↗

Wide Angle, Single Screen, Gridded Square-Loop Frequency Selective Surface for Diplexing Two Closely Separated Frequency Bands

The design and performance of a wide angle, single screen, frequency selective surface (FSS) with gridded square-loop path elements are described for diplexing closely separated signal bands, for example, X- and Ku-band signals in an Orbiting Very Long Baseline Interferometer (OVLBI) earth station reflector antenna system, as well as other applications such as military and commercial communications via satellites. Excellent agreement is obtained between the predicted and measured results of this FSS design using the gridded square-loop patch elements sandwiched between 0.0889 cm thick tetrafluoroethylene fluorocarbon polymer (PTFE) slabs. Resonant frequency drift is reduced by 1 GHz with an incidence angle from 0 deg normal to 40 deg from normal.

Wu, Te-Kao↗

Construction and Calibration of a Difference Frequency Laser Spectrometer and New THZ Frequency Measurements of water and Ammonia

A three laser system based on 852nm DBR lasers has been constructed and used to generate radiation in the 750 GHz to 1600 GHz frequency region. The system works by locking two of the three lasers to modes of an ultra low expansion Fabry-Perot cavity. The third laser is offset locked to one of the cavity locked lasers with conventional microwave techniques. The signal from the offset laser and the other cavity locked laser are injected into a Master Oscillator Power Amplifier (MOPA), amplified and focused on a low temperature grown GaAs photomixer, which radiates the difference frequency. The system has been calibrated with molecular lines to better than one part in 10(exp 7). In this paper we present the application of this system to the v(sub 2) in inversion band of Ammonia and the ground and v(sub 2) states of water. A discussion of the system design, the calibration and the new spectral measurements will be presented.

Pearson, J. C.↗

Frequency Swept Diode-pumped Single Frequency TM,Ho:YLiF Laser for spaceborne Doppler Lidar

Optical heterodyne experiments involving the photomixing of two single frequency, deode-pumped thulium holmium yttrium lithium flouride lasers are described. Operated in external frquency stabilization loops, the lasers exhibit 1MHz short term stability, and are photomixed and offset-locked at 140 MHz. Summation of sine wave modulation onto the PZT control voltage on one laser results in frequency swept operation over a continuous tuning range of 160 MHz.

Doppler Lidar Optical heterodyne experiments↗