Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY REGULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Simplified cut core inductor design

Although filter inductor designers have routinely tended to specify molypermalloy powder cores for use in high frequency power converters and pulse-width modulated switching regulators, there are sigificant advantages in specifying C cores and cut toroids fabricated from grain oriented silicon steels which should not be overlooked. Such steel cores can develop flux densities of 1.6 tesla, with useful linearity to 1.2 tesla, whereas molypermalloy cores carrying d.c. current have useful flux density capabilities only to about 0.3 tesla. The use of silicon steel cores thus makes it possible to design more compact cores, and therefore inductors of reduced volume, or conversely to provide greater load capacity in inductors of a given volume. Information is available which makes it possible to obtain quick and close approximations of significant parameters such as size, weight and temperature rise for silicon steel cores for breadboarding. Graphs, nomographs and tables are presented for this purpose, but more complete mathematical derivations of some of the important parameters are also included for a more rigorous treatment.

Mclyman, W. T.↗

On-orbit performance of the 12 GHz, 200 watt transmitter experiment package for CTS

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite (CTS) are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST), and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling-wave tube with a multistage depressed collector and a stepped velocity-tapered slow-wave structure for efficiency enhancement. It has an RF output power of 240 W and an overall efficiency of 51.5% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control, and protection for the OST. It has a measured dc-dc conversion efficiency of 86.5% to 88.5%. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power, frequency response, and performance with single and multiple (two) carriers frequency-modulated by video signals.

Alexovich, R. E.↗

LPG Component Leak Frequency Estimation

Liquefied petroleum gas (LPG) is used in heating, cooking, and as a vehicle fuel (called autogas). A safety risk assessment may be needed to assess potential hazard scenarios and inform the regulations, codes, and standards that apply to LPG facilities, such as autogas refueling facilities. The frequency of unintended releases in an LPG system is an important aspect of a system quantitative risk assessment. This report documents estimation of leakage frequencies for individual components of LPG systems. These frequencies are described using uncertainty distributions obtained with Bayesian statistical methods, generic data, and LPG data which were publicly available. There was a lack of LPG data in the literature, so frequencies for most components were developed with generic data and should be used cautiously; without additional information about component leak frequencies in LPG systems, it is not known whether these generic frequencies may be conservative or non-conservative.

02 PETROLEUM↗

River Regulation Alleviates the Impacts of Climate Change on US Thermoelectricity Production

Climate change and anthropogenic activities can both influence stream temperature, which is a critical indicator of thermoelectric power generation potential. Previous studies emphasized the vulnerability of power-generation systems to climate warming (ref 1, 2). Despite the fact that two-thirds of the global rivers are regulated by dams (ref 3), the relative impacts of water management and climate change on stream temperature and thermoelectric production have not yet been evaluated. Using an integrated modeling system applied to the conterminous United States, simulations confirm the dominant role of climate change in shaping the future trends of stream temperature. However, water management, reservoir regulation in particular, can mitigate the stream temperature warming and reduce the frequency and magnitude of extreme high stream temperatures through redistribution of the seasonal streamflow. Moreover, water management can alleviate the loss of power plant usable capacity from climate change to the level of reduced warming from emission mitigation. By regulating the flow and temperature regimes, water management is a promising adaptation measure to alleviate climate change induced effects in the water-energy nexus.

Zhang, Xiao↗

Simultaneous structural and control optimization via linear quadratic regulator eigenstructure assignment

A method for simultaneous structural and control design of large flexible space structures (LFSS) to reduce vibration generated by disturbances is presented. Desired natural frequencies and damping ratios for the closed loop system are achieved by using a combination of linear quadratic regulator (LQR) synthesis and numerical optimization techniques. The state and control weighing matrices (Q and R) are expressed in terms of structural parameters such as mass and stiffness. The design parameters are selected by numerical optimization so as to minimize the weight of the structure and to achieve the desired closed-loop eigenvalues. An illustrative example of the design of a two bar truss is presented.

Becus, G. A.↗

A Novel State-Constrained Primary Control for Grid-Forming Inverters

The problem of operating an AC microgrid with purely inverter-based generating units is considered, and a novel vector control for the constrained grid-forming (GFM) inverters is proposed. The design aims to achieve the primary control objectives of the GFM inverters: voltage establishment, synchronization, and voltage/frequency regulation. It is novel that the proposed control also ensures all operational variables constrained both real-time and for all the time except for low voltage during the period of grid forming. The constraints include frequency, output AC voltage, input DC power, and active/reactive power injections to the grid. Here, in this paper, outcomes of a detailed simulation are presented to demonstrated that the above design objectives are met and that the overall performance is superior due to its unique ability of simultaneously controlling the whole vectors of the inverter state and output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Supply-Conditioning Circuit

Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

Primas, L. E.↗

The cryptoendolithic microbial environment in the Antarctic cold desert: temperature variations in nature

In the Antarctic cold desert, cryptoendolithic microorganisms live under the surface of porous sandstone rocks. During the austral summer, the environment of the near-surface rock layers colonized by organisms is characterized by two kinds of temperature oscillations, both occurring across the freezing point. Low-frequency (diurnal) and large-amplitude (up to about 20 degrees C) oscillations on the sunlit surface of rocks result in a daily freeze-thaw cycle. This is a result of the diurnal changes in the sun altitude and angle with respect to the rock surface. The biological effect of this oscillation is the regulation of the onset and cessation of metabolic activity. The high-frequency (few minutes) oscillations occur only under certain weather conditions (sunny days with light winds) and are superimposed on the low-frequency oscillations. They are caused by the cooling effect of wind gusts on rock surfaces that are much warmer than ambient air temperatures. High-frequency oscillations result in a rapid freeze-thaw cycle on the surface, which, however, does not reach the microbial zone. These high-frequency freeze-thaw oscillations are probably the cause of the abiotic nature of the rock surface. Both oscillations seem to have an effect on rock weathering.

Cold Climate↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics↗

Severe and mild drought cause distinct phylogenetically linked shifts in the blue grama (Bouteloua gracilis) rhizobiome

Plants rely on a diverse rhizobiome to regulate nutrient acquisition and plant health. With increasing severity and frequency of droughts worldwide due to climate change, untangling the relationships between plants and their rhizobiomes is vital to maintaining agricultural productivity and protecting ecosystem diversity. While some plant physiological responses to drought are generally conserved, patterns of root exudation (release of small metabolites shown to influence microbes) and the consequential effects on the plant rhizobiome can differ widely across plant species under drought. To address this knowledge gap, we conducted a greenhouse study using blue grama ( Bouteloua gracilis ), a drought-tolerant C4 grass native to shortgrass prairie across North American plains, as a model organism to study the effect of increasing drought severity (ambient, mild drought, severe drought) on root exudation and the rhizobiome. Our previous results demonstrated physiological effects of increasing drought severity including an increase in belowground carbon allocation through root exudation and shifts in root exudate composition concurrent with the gradient of drought severity. This work is focused on the rhizobiome community structure using targeted sequencing and found that mild and severe drought resulted in unique shifts in the bacterial + archaeal and fungal communities relative to ambient, non-droughted controls. Specifically, using the change in relative abundance between ambient and drought conditions for each ZOTU as a surrogate for population-scale drought tolerance (e.g., as a response trait), we found that rhizobiome response to drought was non-randomly distributed across the phylogenies of both communities, suggesting that Planctomycetota , Thermoproteota (formerly Thaumarchaeota ), and the Glomeromycota were the primary clades driving these changes. Correlation analyses indicated weak correlations between droughted community composition and a select few root exudate compounds previously implicated in plant drought responses including pyruvic acid, D-glucose, and myoinositol. This study demonstrates the variable impacts of drought severity on the composition of the blue grama rhizobiome and provides a platform for hypothesis generation for targeted functional studies of specific taxa involved in plant-microbe drought responses.

Goemann, Hannah M.↗

Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS). Phase 1: Users handbook

The EASY5 macro component models developed for the spacecraft power system simulation are described. A brief explanation about how to use the macro components with the EASY5 Standard Components to build a specific system is given through an example. The macro components are ordered according to the following functional group: converter power stage models, compensator models, current-feedback models, constant frequency control models, load models, solar array models, and shunt regulator models. Major equations, a circuit model, and a program listing are provided for each macro component.

Kim, S.↗

Mechanically induced alterations in cultured skeletal muscle growth

Model systems are available for mechanically stimulating cultured skeletal muscle cells by passive tensile forces which simulate those found in vivo. When applied to embryonic muscle cells in vitro these forces induce tissue organogenesis, metabolic adaptations, and muscle cell growth. The mechanical stimulation of muscle cell growth correlates with stretch-induced increases in the efflux of prostaglandins PGE2 and PGF2(alpha) in a time and frequency dependent manner. These prostaglandins act as mechanical 'second messengers' regulating skeletal muscle protein turnover rates. Since they also effect bone remodelling in response to tissue loading and unloading, secreted prostaglandins may serve as paracrine growth factors, coordinating the growth rates of muscle and bone in response to external mechanical forces. Cell culture model systems will supplement other models in understanding mechanical transduction processes at the molecular level.

Vandenburgh, H. H.↗

RNA-binding proteins in plants: the tip of an iceberg?

RNA-binding proteins, which are involved in the synthesis, processing, transport, translation, and degradation of RNA, are emerging as important, often multifunctional, cellular regulatory proteins. Although relatively few RNA-binding proteins have been studied in plants, they are being identified with increasing frequency, both genetically and biochemically. RNA-binding proteins that regulate chloroplast mRNA stability and translation in response to light and that have been elegantly analyzed in Clamydomonas reinhardtii have counterparts with similar functions in higher plants. Several recent reports describe mutations in genes encoding RNA-binding proteins that affect plant development and hormone signaling.

Review↗

Ferroresonant flux coupled battery charger

A battery charger for incorporation into an electric-powered vehicle is disclosed. The charger includes a ferroresonant voltage-regulating circuit for providing an output voltage proportional to the frequency of an input AC voltage. A high frequency converter converts a DC voltage supplied, for example, from a rectifier connected to a standard AC outlet, to a controlled frequency AC voltage which is supplied to the input of the ferroresonant circuit. The ferroresonant circuit includes an output, a saturable core transformer connected across the output, and a first linear inductor and a capacitor connected in series across the saturable core transformer and tuned to resonate at the third harmonic of the AC voltage from the high frequency converter. The ferroresonant circuit further includes a second linear inductor connected between the input of the ferroresonant circuit and the saturable core transformer. The output voltage from the ferroresonant circuit is rectified and applied across a pair of output terminals adapted to be connected to the battery to be charged. A feedback circuit compares the voltage across the output terminals with a reference voltage and controls the frequency of the AC voltage produced by the high frequency converter to maintain the voltage across the output terminals at a predetermined value. The second linear inductor provides a highly reactive load in the event of a fault across the output terminals to render the charger short-circuit proof.

McLyman, Colonel W. T.↗

Optimization of the structural and control system for LSS with reduced-order model

The objective is the simultaneous design of the structural and control system for space structures. The minimum weight of the structure is the objective function, and the constraints are placed on the closed loop distribution of the frequencies and the damping parameters. The controls approach used is linear quadratic regulator with constant feedback. A reduced-order control system is used. The effect of uncontrolled modes is taken into consideration by the model error sensitivity suppression (MESS) technique which modified the weighting parameters for the control forces. For illustration, an ACOSS-FOUR structure is designed for a different number of controlled modes with specified values for the closed loop damping parameters and frequencies. The dynamic response of the optimum designs for an initial disturbance is compared.

Khot, N. S.↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗