Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Stabilized fiber-optic frequency distribution system

A technique for stabilizing reference frequencies transmitted over fiber-optic cable in a frequency distribution system is discussed. The distribution system utilizes fiber-optic cable as the transmission medium to distribute precise reference signals from a frequency standard to remote users. The stability goal of the distribution system is to transmit a 100-MHz signal over a 22-km fiber-optic cable and maintain a stability of 1 part in 10(17) for 1000-second averaging times. Active stabilization of the link is required to reduce phase variations produced by environmental effects, and is achieved by transmitting the reference signal from the frequency standard to the remote unit and then reflecting back to the reference unit over the same optical fiber. By comparing the phase of the transmitted and reflected signals at the reference unit, phase variations of the remote signal can be measured. An error voltage derived from the phase difference between the two signals is used to add correction phase.

Primas, L. E.↗

An improved linear ion trap physics package

This article describes an improvement in the architecture of the physics package used in the Linear Ion Trap (LIT)-based frequency standard recently developed at JPL. This new design is based on the observation that ions can be moved along the axis of an LIT by applied dc voltages. The state selection and interrogation region can be separated from the more critical microwave resonance region where the multiplied local oscillator signal is compared with the stable atomic transition. This separation relaxes many of the design constraints of the present units. Improvements include increased frequency stability and a substantial reduction in size, mass, and cost of the final frequency standard.

Prestage, J. D.↗

A rubidium clock for SEEK-TALK

The development of a tactical rubidium frequency standard (TRFS) for the SEEK-TALK program is discussed. This effort, which is entering the prototype stage, is directed toward the establishment of a production capability for miniature rubidium clocks of medium stability capable of fast warmup and extreme ruggedness for military avionics applications. The overall unit consists of an ultraminiature physics package and four plug-in circuit boards inside a 2 1/2-inch square by 4-inch box. This size is achieved without the extensive use of hybrid microcircuitry, yet is believed to be the smallest atomic frequency standard yet developed.

Riley, W. J.↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗

Reduction of quantization error in measurement of frequency

Method reduces quantization errors using new digital circuit. Circuit provides very high resolution (10 to the minus 2nd power to 10 to the minus 3rd power Hz) without high-speed counters. It lends itself to microminaturization and is simple to construct. Unknown frequency is compared to standard frequency by means of zero-crossing coincidence-detecting circuit.

Nossen, E. J.↗

Precision timekeeping using a small passive hydrogen maser

The timekeeping ability of a prototype passive hydrogen maser which is a factor of 5 smaller in size, weight, and cost than any previously designed, was compared to UTC (NBS) based on 10 cesium frequency standards including a large primary standard, NBS-4. The frequency of the prototype was monitored as a function of source pressure, cavity temperature, microwave power, modulation width, and magnetic field. Based on these measurements, a frequency stability of better than 6 x 10 to the -15 power was expected, implying a timekeeping ability of order 0.5 ns/day. Measurements vs UTC(NBS) indicate a joint timekeeping a stability of order 1.2 ns/day. Simultaneous measurements made between NBS-4, UTC(6600), and the small passive me maser show peak to peak time variations of the small maser vs UTC(6600) was 10 ns for the full 32 days if the average rate and drift are considered. Frequency stability of the small prototype vs UTC (NBS) was to 1.1 x 10 to the -14th power for tau = 1 to 8 days.

Walls, F. L.↗

Far infrared laser frequencies of CH3OD and N2H4

The frequencies of 26 laser lines with wavelengths between 57 and 534 microns are measured in the optically pumped laser gases CH3OD and N2H4. A pair of 12CO2 lasers are employed as a frequency standard for the heterodyne frequency measurements. As the measurements are oriented toward spectroscopic applications of FIR lasers where dense, broad, frequency coverage is essential, every strong pump absorption of the two molecules for new lines that might be made to lase by varying the laser gas pressure and the tuning of the pump laser are investigated.

Radford, H. E.↗

Cesium standard for satellite application

A Cesium frequency standard that was developed for satellite applications is discussed. It weighs 23 lbs. and uses 23.5 watts of power, achieves a stability of 1 x ten to the minus 13th power/100,000 seconds, and is radiation hardened. To achieve the weight and reliability requirements, both thick and thin film hybrid circuits were utilized. A crystal oscillator is used to improve short-term stability and performance on a moving platform.

Bloch, M. B.↗

Innovation and reliability of atomic standards for PTTI applications

Innovation and reliability in hyperfine frequency standards and clock systems are discussed. Hyperfine standards are defined as those precision frequency sources and clocks which use a hyperfine atomic transition for frequency control and which have realized significant commercial production and acceptance (cesium, hydrogen, and rubidium atoms). References to other systems such as thallium and ammonia are excluded since these atomic standards have not been commercially exploited in this country.

Kern, R.↗

Metafitting: Weight optimization for least-squares fitting of PTTI data

For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

Douglas, Rob J.↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

Remer, D. S.↗

Opto-Electronic Oscillator Stabilized By A Hyperfine Atomic Transition

Opto-electronic oscillator (OEO) is a closed-loop system with part of the loop is implemented by an optical beam, and the rest by RF circuitry. The technological advantage of this approach over traditional all-RF loops in the gigahertz range comes from the that frequency filtering can be done far more efficiently in the optical range with compact, low power, and have superior stability. In this work, we report our preliminary results on using the phenomenon of coherent population trapping in (87) Rb vapor as an optical filter. Such a filter allows us to stabilize the OEO at the hyperfine splitting frequency of rubidium, thus implementing a novel type of frequency standard.

OEO (OPTO-ELECTRONIC OSCILLATORS)↗

Design concept for the microwave interrogation structure in PARCS

In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment.

frequency standard phase shift microwave cavity↗

The inverse problem of estimating the gravitational time dilation

Precise testing of the gravitational time dilation effect suggests comparing the clocks at points with different gravitational potentials. Such a configuration arises when radio frequency standards are installed at orbital and ground stations. The ground-based standard is accessible directly, while the spaceborne one is accessible only via the electromagnetic signal exchange. Reconstructing the current frequency of the spaceborne standard is an ill-posed inverse problem whose solution depends significantly on the characteristics of the stochastic electromagnetic background. The solution for Gaussian noise is known, but the nature of the standards themselves is associated with nonstationary fluctuations of a wide class of distributions. A solution is proposed for a background of flicker fluctuations with a spectrum (1/f){sup γ}, where 1 < γ < 3, and stationary increments. The results include formulas for the error in reconstructing the frequency of the spaceborne standard and numerical estimates for the accuracy of measuring the relativistic redshift effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗