Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

VLBI and GPS-based Time-Transfer Using CONT08 Data

One important prerequisite for geodetic Very Long Baseline Interferometry (VLBI) is the use of frequency standards with excellent short term stability. This makes VLBI stations, which are often co-located with Global Navigation Satellite System (GNSS) receiving stations, interesting for studies of time- and frequency-transfer techniques. We present an assessment of VLBI time-transfer based on the data of the two week long consecutive IVS CONT08 VLBI campaign by using GPS Carrier Phase (GPSCP). CONT08 was a 15 day long campaign in August 2008 that involved eleven VLBI stations on five continents. For CONT08 we estimated the worst case VLBI frequency link stability between the stations of Onsala and Wettzell to 1e-15 at one day. Comparisons with GPSCP confirm the VLBI results. We also identify time-transfer related challenges of the VLBI technique as used today.

Rieck, Carsten↗

Reference frequency transmission over optical fiber

A 100-MHz reference frequency from a hydrogen maser frequency standard has been transmitted via optical fiber over a 14-km distance with a measured stability of 1.5 X 10 to the-15 power for 1000 seconds averaging time. This capability was demonstrated in a frequency distribution experiment performed in April, 1986. The reference frequency was transmitted over a single-mode fiber-optic link from Deep Space Station (DSS) 13 to DSS 12 and back. The background leading up to the experiment and the significance of stable reference frequency distribution in the Deep Space Network (DSN) is discussed. Also described are the experiment, including the fiber-optic link, the measurement method and equipment, and finally the results of the experiment.

Lutes, G.↗

Progress Report for a New Cryogenic Sapphire Oscillator

We present design progress and subsystem test results for a new short-term frequency standard, the Voltage Controlled Sapphire Oscillator (VCSO). Included are sapphire resonator and coupling design, cryocooler environmental sensitivity tests, Q measurement results, and turnover temperature results. A previous report presented history of the design related to resonator frequency and frequency compensation [1]. Performance goals are a frequency stability of 1x10(exp -14) (1 second less than or equal to (tau) less than or equal to 100 seconds) and two years or more continuous operation. Long-term operation and small size are facilitated by use of a small Stirling cryo-cooler (160W wall power) with an expected 5 year life.

oscillator↗

Spacecraft Tests of General Relativity

Current spacecraft tests of general relativity depend on coherent radio tracking referred to atomic frequency standards at the ground stations. This paper addresses the possibility of improved tests using essentially the current system, but with the added possibility of a space-borne atomic clock. Outside of the obvious measurement of the gravitational frequency shift of the spacecraft clock, a successor to the suborbital flight of a Scout D rocket in 1976 (GP-A Project), other metric tests would benefit most directly by a possible improved sensitivity for the reduced coherent data. For purposes of illustration, two possible missions are discussed. The first is a highly eccentric Earth orbiter, and the second a solar-conjunction experiment to measure the Shapiro time delay using coherent Doppler data instead of the conventional ranging modulation.

Anderson, John D.↗

Higher Pole Linear Traps for Atomic Clock Applications

We investigate experimentally and theoretically higher pole linear ion traps for frequency standard use. We have built a 12-pole trap and have successfully loaded ions into it from a linear quadrupole trap. By solving the Boltzmann equation describing large ion clouds where space charge interactions are important, we show that clock frequency changes due to ion number fluctuations are much smaller in ion clocks based multipole traps than comparable clocks based on quadrupole linear traps.

Prestage, John D.↗

Measurement of the power spectral density of phase of the hydrogen maser

Hydrogen masers are being developed for the Deep Space Network as improved frequency standards, in order to achieve better timing accuracies, reduced Doppler residuals, and lower phase noise in the tracking system. Performance data for the masers are given in two forms: time domain performance, useful for analyzing time keeping systems and Doppler systems; and frequency domain performance, useful for analyzing tracking systems. Particular attention is given to frequency domain performance, as obtained from both time domain measurements and direct measurements.

Sward, A.↗

Shuttle time and frequency transfer experiment

A proposed space shuttle experiment to demonstrate techniques for global high precision comparison of clocks and primary frequency standards is described. The experiment, using transmitted microwave and pulsed laser signals, compared a hydrogen maser clock onboard the space shuttle with a clock in a ground station in order to demonstrate time transfer with accuracies of 1 nsec or better and frequency comparison at the 10 to the -14th power accuracy level.

Allan, D. W.↗

Stabilized Photonic Links for Deep Space Tracking, Navigation, and Radio Science Applications

Stable fiber optic links have been operational in NASA's DSN for over 20 years providing distribution limited fractional frequency stability below 10-14 at one second and reaching 10-18 at approx 10,000 seconds. We summarize recent stabilized photonic link developments for DSN operation capable of high performance and reliability, and at much lower cost than previous systems. Recent research has focused on two applications, 1) actively stabilized links to transport 100 MHz metrology frequency references to sites up to 30 km from the central atomic frequency standard, and 2) stabilized links transporting broadband S, X, and Ka band signals used in deep space tracking and navigation and antenna arraying applications.

frequency distribution↗

Fundamental Noise-Limited Optical Phase Locking at Femtowatt Light Levels

We describe an optical phase lock loop (PLL) designed to recover an optical carrier at powers below one picowatt in a Deep Space optical transponder. Previous low power optical phase lock has been reported with powers down to about 1 pW. We report the demonstration and characterization of the optical phase locking at femtowatt levels. We achieved a phase slip rate below one cycle-slip/second at powers down to 60 femtowatts. This phase slip rate corresponds to a frequency stability of 1 10(exp -14) at 1 s, a value better than any frequency standard available today for measuring times equal to a typical two-way delay between Earth and Mars. The PLL shows very robust stability at these power levels. We developed simulation software to optimize parameters of the second order PLL loop in the presence of laser flicker frequency noise and white phase (photon) noise, and verified the software with a white phase noise model by Viterbi. We also demonstrated precise Doppler tracking at femtowatt levels.

Doppler ranging↗

Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

This document is a compilation of technical papers presented at the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting held 1-3 December 1998 at the Hyatt Regency Hotel at Reston Town Center, Reston, Virginia. Papers are in the following categories: 1) Recent developments in rubidium, cesium, and hydrogen-based atomic frequency standards, and in trapped-ion and space clock technology; 2) National and international applications of PTTI technology with emphasis on GPS and GLONASS timing, atomic time scales, and telecommunications; 3) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; and 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, computer networks, WAAS, and LORAN.

Breakiron, Lee A.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors

GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.

Diener, William A.↗

Noise in laser oscillator systems

The aim of the SUNLITE program is to demonstrate the performance of ultra-stable laser systems in the environment of space. The program uses Non-Planar Ring Oscillators (NPRO) which have shown great promise for time and frequency standards with unprecedented resolution and stability. An immediate goal is to test NPRO oscillators in orbital free fall by 1994. During the past year there was remarkable progress in the design and pre-flight testing of the SUNLITE test package. Current theoretical studies are investigating the possible effects of various noise sources on the linewidth and linecenter frequency stability of servocontrolled NPRO lasers. The frequency control system is reviewed and the potential impact on frequency stability of noise sources in the control system and in the environment is considered.

Hafele, Joseph C.↗

27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

The 24th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers presented at the 24th Precise Time and Time Interval (PTTI) Applications and Planning Meeting held in Dec. 1992 is presented. Papers are in the following categories: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales, and international telecommunications; applications of PTTI technology to the telecommunications, power distribution, and platform positioning, and geophysical survey industries; applications of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Sydnor, Richard L.↗

Proceedings of the 23rd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers, from the 23rd annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, is presented. Papers were given in the following categories: (1) developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, comparison of national time scales and international communications; (3) applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) applications of PTTI technology to evolving military communications and navigation systems; and (5) dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Richard L. Sydnor↗