Integral Effect Test of ATLAS Facility on Multiple Failure in a Prolonged Station Blackout
Since the Fukushima accident, the design extension conditions (DECs) in a nuclear power plant (NPP) have attracted more importance with respect to nuclear reactor safety, and a consensus has been developed such that these high-risk multiple failure accidents should be revisited from the viewpoint of a reinforcement of the 'defense in depth' concept. In particular, a station blackout (SBO) is one of the most important DECs because a loss of the heat sink without an appropriate accident measure might lead to a core uncovery, core damage, and ultimately, a core meltdown under high pressure. SBO has been recognized to be one of the risk-contributing sequences when combined with additional failure of components such as a reactor coolant pump (RCP) seal leakage or a steam generator tube rupture (SGTR). The RCP seal failure could occur due to a loss of continuous cooling through the seal during SBO. The SGTR during SBO can be a potentially important risk due to the release of the fission product with bypassing the containment boundary. The objective of this study is to experimentally simulate and analyze a prolonged SBO scenario in a thermal hydraulic integral effect test facility, ATLAS. As test items in OECD-ATLAS project, two tests for the SBO condition were conducted with additional failures, that is, a RCP seal failure (A2.1 test) and a SGTR (A2.2 test). In those tests, both the effect of the additional failure on reactor safety and the natural circulation characteristics during prolonged SBO conditions could be investigated. The present test can provide physical insight into the system response during the prolonged SBO scenario combined with the multiple failure.