Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance of a silicon photovoltaic module under enhanced illumination and selective filtration of incoming radiation with simultaneous cooling

A promising option to reduce the cost of silicon photovoltaic systems is to concentrate the sunlight incident on the solar cells to increase the output power. However, this leads to higher module temperatures which affects performance adversely and may also cause long term damage. Proper cooling is therefore necessary to operate the system under concentrated radiation. The present work was undertaken to circumvent the problem in practical manner. A suitable liquid, connected to a heat exchanger, was placed in the housing of the photovoltaic module and unwanted wavelengths of solar radiation were filtered out to minimise overheating of the cells. The selection of the liquid was based on factors such as boiling point, transparency towards visible radiation, absorption of infrared and ultraviolet radiation, stability, flow characteristics, heat transfer properties, and electrical nonconductivity. Using a square parabolic type reflector, more than two fold increase in output power was realised on a clear sunny day employing a 0.13 m{sup 2} silicon solar module. Without the cooling arrangement the panel temperature rose uncontrollably. (author)

14 SOLAR ENERGY↗

Point-of-use filtration units as drinking water distribution system sentinels

Abstract Municipal drinking water distribution systems (DWDSs) and associated premise plumbing (PP) systems are vulnerable to proliferation of opportunistic pathogens, even when chemical disinfection residuals are present, thus presenting a public health risk. Monitoring the structure of microbial communities of drinking water is challenging because of limited continuous access to faucets, pipes, and storage tanks. We propose a scalable household sampling method, which uses spent activated carbon and reverse osmosis (RO) membrane point-of-use (POU) filters to evaluate mid- to long-term occurrence of microorganisms in PP systems that are relevant to consumer exposure. As a proof of concept, POU filter microbiomes were collected from four different locations and analyzed with 16S rRNA gene amplicon sequencing. The analyses revealed distinct microbial communities, with occasional detection of potential pathogens. The findings highlight the importance of local, and if possible, continuous monitoring within and across distribution systems. The continuous operation of POU filters offers an advantage in capturing species that may be missed by instantaneous sampling methods. We suggest that water utilities, public institutions, and regulatory agencies take advantage of end-of-life POU filters for microbial monitoring. This approach can be easily implemented to ensure drinking water safety, especially from microbes of emerging concerns; e.g., pathogenic Legionella and Mycobacterium species.

42 ENGINEERING↗

Direct intercalation of MoS 2 and WS 2 thin films by vacuum filtration

In the development of next-generation electronics and energy devices, intercalation compounds of transition metal dichalcogenides (TMDCs) are gaining attention for their unique properties that result from synergistic interactions between guest species and host materials. Nowadays, intercalation compounds of MoS 2 and WS 2 are commonly prepared by a two-step process: (1) exfoliation to form single-layer and/or few-layer nanosheets and (2) restacking the nanosheets with the guest species by vigorously mixing the exfoliated suspension with the solution of guest species. While a wide variety of intercalation compounds have been synthesized using this approach, the intercalation process is often timeconsuming, and the product slurry limits material quality and impedes characterization and applications. Herein, we report a versatile method for preparing intercalated TMDCs in a thin-film morphology. Using this approach, we successfully prepared a range of existing intercalation compounds of MoS 2 and WS 2 (e.g., ferrocene and amine intercalated MoS 2 and WS 2 ). Additionally, by leveraging the versatility of this intercalation method, we report we intercalated phenazine and benzoquinone into MoS 2 and WS 2 for the first time.

36 MATERIALS SCIENCE↗

Molybdenum Coatings with Filtration of Plasma Flow

Deposition of molybdenum coatings in arc discharge with assistance of HF one is analyzed in this paper. To avoid substrate heating to high temperature and micro-arc formation during cleaning process, the surface cleaning was carried out with HF plasma only. For reduction of droplet fraction in plasma the 'freestanding' filter was utilized. As a filter a solenoid was used, which generated a curvilinear (with the angle of 90 deg.) transportation magnetic field. The effective crosssectional area of the plasma flow at which was observed the uniform distribution of the thickness of the applied coating, was equal to 113 sm{sup 2}. The coating on the base of arc discharge, filter and HF-biasing of substrate were deposited on different substrates, including glass and stainless steel.The optical (refractive index) properties of molybdenum films are presented. The reflective characteristics of the obtained molybdenum films in the range of wavelengths from 200 to 700 nm were measured.Molybdenum films were also investigated under the effect of the plasma emission, using an ECR discharge in a simple double-mirror magnetic trap. The time varying negative potential was supplied to sample holder what provided a wide energy distribution of ions bombarded the sample surface in range 30...1500V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗

The influence of bowtie filtration on cone-beam CT image quality

The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie filter implemented in a system for image-guided radiation therapy (Elekta oncology system, XVI) as a compensator for improved image quality through fluence modulation, reduction in x-ray scatter, and reduction in patient dose. Dose measurements with and without the bowtie filter were performed on a CTDI Dose phantom and an empirical fit was made to calculate dose for any radial distance from the central axis of the phantom. Regardless of patient size, shape, anatomical site, and field of view, the bowtie filter results in an overall improvement in CT number accuracy, image uniformity, low-contrast detectability, and imaging dose. The implemented bowtie filter offers a significant improvement in imaging performance and is compatible with the current clinical system for image-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Parametric Model of Debris Penetration Through Sump Strainers with Concurrent Filtration and Shedding

Two primary debris fates are of key interest to the risk-informed resolution analysis: (1) accumulation on the primary sump strainers with corresponding head loss, and (2) partial penetration of debris through the strainers with subsequent accumulation on fuel channel screens in the lower plenum. Accumulation on the core can impede flow, potentially causing local excessive heating and potentially limiting mixing to the point that boron precipitation can occur. Two opportunities exist for diverting debris away from the core: (1) a fraction of the ECCS recirculation flow feeds containment spray systems directly from the common header, (2) a fraction of debris-laden flow can bypass the core and proceed directly to the break without accumulating debris on the fuel assembly screen. Both of these pathways extend the time necessary to build debris levels of concern on either the strainers or the fuel assemblies.

42 ENGINEERING↗