Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Effects of the Grazing Incidence Geometry on X-ray Photon Correlation Spectroscopy Measurements

X-ray photon correlation spectroscopy (XPCS) is a versatile tool to measure dynamics on the nanometer to micrometer scale in bulk samples. XPCS has also been applied in grazing incidence (GI) geometry to examine the dynamics of surface layers. However, considering GI scattering experiments more universally, the GI geometry leads to a superposition of signals due to reflection and refraction effects, also known from the distorted-wave Born approximation (DWBA). In this paper, the impact of these reflection and refraction effects on the correlation analysis is determined experimentally by measuring grazing incidence transmission XPCS (GT-XPCS) and grazing incidence XPCS (GI-XPCS) simultaneously for a thin film sample, showing non-equilibrium dynamics. Here the results of the GI and GT geometry comparisons are combined within the framework of the standardly applied, simplified DWBA. These calculations allow identifying the main contributions of the detected signal from the leading scattering terms along the out-of-plane direction q z , which dominate the measured intensity pattern on the detector. In combination with the calculation of the non-linear effect of refraction in GTSAXS and GISAXS, it is possible to identify experimental conditions that can be chosen to run experiments and data analysis as close as possible to transmission XPCS and to explain which limitations for data interpretations are observed. Consequently, the beam exposure can be significantly reduced by using GI geometry only. Calculations of experimental settings prior to experiments are detailed to determine suitable q z regions for a variety of material systems measured in bulk-sensitive GI-XPCS experiments, allowing us to determine the scaling behavior of typical decay times as a function of q that is comparable to the scaling behavior obtained in distortion-free GT-XPCS or transmission XPCS experiments.

36 MATERIALS SCIENCE↗

Electrostatic pair-ion solitons in nonplanar geometries

Electrostatic solitons formation parallel to the magnetic field in pair-ion plasmas are studied for spherical and cylindrical geometries. A modified Korteweg-de Vries equation is obtained using the reductive perturbation technique. It is found that both electrostatic hump and dip type structures are formed in nonplanar geometries depending on the temperature difference between positively and negatively charged ions. The numerical solution shows that amplitude of the soliton is large in spherical geometry in comparison with cylindrical geometry The soliton solutions are also presented by choosing different ion temperature ratios of the positive and negative ions to understand some aspects of laboratory produced fullerene plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using cylindrical implosions to investigate hydrodynamic instabilities in convergent geometry

Hydrodynamic instabilities such as the Rayleigh–Taylor (RT) and Richtmyer–Meshkov instabilities disrupt inertial confinement fusion (ICF) implosions through the growth of 3D perturbations. Growth of these 3D imperfections at the interfaces of an ICF capsule during implosion lead to mixing between materials that is detrimental to performance. These instabilities have been studied extensively in planar geometry, but such experiments lack the effects of convergence in spherical implosions. While several studies have been performed in spherical geometry, these often lack a direct means to measure perturbation growth. Experiments in cylindrical geometry include convergence effects while maintaining direct diagnostic access. Although cylinders have less compression than spheres, they do provide an excellent platform to validate modeling for convergent geometries. The problem with previous cylindrical implosion experiments was that the convergence ratios were limited to ~4. With the National Ignition Facility (NIF), larger cylindrical targets can be driven to convergences of 10–15 while maintaining a large enough final diameter to measure perturbation growth. This paper reviews the design process used to both benchmark radiation hydrodynamics codes and enable 1D post-processed simulations to explore design space to separate compression effects from acceleration/deceleration RT instability. Results from 1D simulations suggest that cylindrical implosions on the NIF can produce high-convergence experiments to validate RT instability growth for ICF implosions.

36 MATERIALS SCIENCE↗

Simulated impact of fill tube geometry on recent high-yield implosions at the National Ignition Facility

Inertial confinement fusion capsules fielded at the National Ignition Facility are filled with deuterium and tritium fuel by means of a fill tube. The fill tube introduces a low-density pathway into the fuel region of the capsule that allows high Z contaminant to invade the hot spot during the course of the implosion. A recent series of nominally identical high-yield implosions on the NIF has exhibited significant variability in performance. We evaluate the impact of the fill tube in these implosions computationally to determine whether variations in fill tube geometry could have contributed to this variability. The main contrast between the fill tube geometry in the six shots was the outer diameter of the capsule bore hole, a conical hole into which the fill tube is inserted. In our simulations, the geometry of the bore hole can play a significant role in the development of nonlinear flows seeded by the fill tube. Additionally, we find that the amount of space between the bore hole and the fill tube is the primary factor that determines the amount of contaminant jetted into the hot spot by the fill tube and, in turn, the level of yield reduction due to the fill tube in our simulations. As a consequence, some capsules with 5 μm fill tubes are predicted to outperform capsules with 2 μm fill tubes. We also find that micrometer-scale changes to bore hole size can impact fusion yields by up to four times near the ignition threshold. Nevertheless, simulation trends do not reproduce experimental yield trends, suggesting that the fill tube geometry was not the primary factor contributing to the observed variability in performance and that the fill tube could be masking sensitivity to other asymmetries such as other micrometer-scale capsule defects like voids that were not included in our simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Consistent solutions of the radiation diffusion equation in spherical and cylindrical geometries

We have extended the radiation diffusion model of Hammer and Rosen [Phys. Plasmas 10, 1829 (2003)] to diverging spherical and cylindrical geometries. The effect of curvilinear geometry on the supersonic, expanding wavefront increases as the internal radius of a spherical or cylindrical shell approaches zero. Small spherical geometries are important for modeling systems at the size scale of inertial confinement fusion capsules, at these scales existing quasi-analytic models for planar geometry significantly disagree with the results of simulation. With this method, the benefits of rapid iteration can be applied to common spherical systems at much smaller length scales. We present comparisons between numerical diffusion solutions and the analytic model to give ranges of applicability for the model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MOOSE Reactor Module: An Open-Source Capability for Meshing Nuclear Reactor Geometries

The U.S. Department of Energy (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has developed numerous physics solvers utilizing the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) framework for multiphysics reactor analysis. These solvers require input finite element meshes representing the discretized spatial domain. Typically, reactor analysts turn to licensed tools for the creation of reactor geometry meshes. Recently, open-source functionality has been added to the MOOSE framework to mesh common reactor geometries and improve MOOSE-based nuclear reactor application user workflows. The new functionality is primarily contained in the new Reactor module of MOOSE and includes support for hexagonal pins, assemblies, and cores, extended Cartesian geometry support, options for modeling static and rotating control drums within a hexagonal assembly, core periphery triangulation, and automatic tagging of pin, assembly, plane, and depletion regions for easier post processing of physics results. A set of reactor geometry mesh builder objects further streamlines the construction of hexagonal and Cartesian cores and allows mapping of materials to regions during mesh generation. The meshes produced with the MOOSE Reactor module may be used directly within MOOSE-based applications or exported as Exodus II files for use in other finite element solvers. The tools have been demonstrated and verified using a variety of NEAMS physics solvers on a range of reactor applications, including a sodium-cooled fast reactor core analysis using Griffin, a fast reactor assembly thermal deformation analysis using MOOSE Tensor Mechanics, and a heat pipe–cooled microreactor coupled analysis using Griffin, Bison, and Sockeye. MOOSE’s Reactor module provides significant advantages compared to the use of external meshing tools when analyzing Cartesian and hexagonal reactor lattices using MOOSE-based applications: immediate accessibility (open-source) to the end user, low barrier to entry for new users, speed of mesh generation, volume preservation of meshed fuel pins, and simplification of analysis workflow when used in conjunction with MOOSE-based applications.

99 GENERAL AND MISCELLANEOUS↗

Time evolution of a viscous protoplanetary disk with a free geometry: Toward a more self-consistent picture

Observations of protoplanetary disks show that some characteristics seem recurrent, even in star formation regions that are physically distant such as surface mass density profiles varying as r {sup –1} or aspect ratios of about 0.03-0.23. Accretion rates are also recurrently found around 10{sup –8}-10{sup –6} M {sub ☉} yr{sup –1} for disks that have already evolved. Several models have been developed in order to recover these properties. However, most of them usually simplify the disk geometry if not its mid-plane temperature. This has major consequences for modeling the disk evolution over millions of years and consequently planet migration. In the present paper, we develop a viscous evolution hydrodynamical numerical code that simultaneously determines the disk photosphere geometry and the mid-plane temperature. We then compare our results of long-term simulations with similar simulations of disks with a constrained geometry along the Chiang and Goldreich prescription (d lnH/d lnr = 9/7). We find that the constrained geometry models provide a good approximation of the disk surface density evolution. However, they differ significantly regarding the temperature-time evolution. In addition, we find that shadowed regions naturally appear at the transition between viscously dominated and radiation-dominated regions that falls in the region of planetary formation. We show that χ (photosphere height to pressure scale height ratio) cannot be considered a constant, which is consistent with the findings of Watanabe and Lin. Comparisons with observations show that all disks naturally evolve toward a shallow surface density disk (Σ∝r {sup –1}). The mass flux across the disk typically stabilizes in about 1 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

A test of the standard cosmological model with geometry and growth

We perform a general test of the ΛCDM and wCDM cosmological models by comparing constraints on the geometry of the expansion history to those on the growth of structure. Specifically, we split the total matter energy density, Ω M , and (for wCDM) dark energy equation of state, w, into two parameters each: one that captures the geometry, and another that captures the growth. We constrain our split models using current cosmological data, including type Ia supernovae, baryon acoustic oscillations, redshift space distortions, gravitational lensing, and cosmic microwave background (CMB) anisotropies. We focus on two tasks: (i) constraining deviations from the standard model, captured by the parameters ΔΩ M ≡ Ω M grow -Ω M geom and Δw ≡ w grow -w geom , and (ii) investigating whether the S 8 tension between the CMB and weak lensing can be translated into a tension between geometry and growth, i.e. ΔΩ M ≠ 0, Δw ≠ 0. In both the split ΛCDM and wCDM cases, our results from combining all data are consistent with ΔΩ M = 0 and Δ w = 0. If we omit BAO/RSD data and constrain the split wCDM cosmology, we find the data prefers Δw < 0 at 3.6σ significance and ΔΩ M > 0 at 4.2σ evidence. We also find that for both CMB and weak lensing, ΔΩ M and S 8 are correlated, with CMB showing a slightly stronger correlation. Furthermore, the general broadening of the contours in our extended model does alleviate the S 8 tension, but the allowed nonzero values of ΔΩ M do not encompass the S 8 values that would point toward a mismatch between geometry and growth as the origin of the tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Finite-geometry models of electric field noise from patch potentials in ion traps

We model electric field noise from fluctuating patch potentials on conducting surfaces by taking into account the finite geometry of the ion trap electrodes to gain insight into the origin of anomalous heating in ion traps. The scaling of anomalous heating rates with surface distance d is obtained for several generic geometries of relevance to current ion trap designs, ranging from planar to spheroidal electrodes. The influence of patch size is studied both by solving Laplace's equation in terms of the appropriate Green's function as well as through an eigenfunction expansion. Scaling with surface distance is found to be highly dependent on the choice of geometry and the relative scale between the spatial extent of the electrode, the ion-electrode distance, and the patch size. Our model generally supports the d{sup -4} dependence currently found by most experiments and models, but also predicts geometry-driven deviations from this trend.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emergent geometry from quantized spacetime

We examine the picture of emergent geometry arising from a mass-deformed matrix model. Because of the mass deformation, a vacuum geometry turns out to be a constant curvature spacetime such as d-dimensional sphere and (anti-)de Sitter spaces. We show that the mass-deformed matrix model giving rise to the constant curvature spacetime can be derived from the d-dimensional Snyder algebra. The emergent geometry beautifully confirms all the rationale inferred from the algebraic point of view that the d-dimensional Snyder algebra is equivalent to the Lorentz algebra in (d+1)-dimensional flat spacetime. For example, a vacuum geometry of the mass-deformed matrix model is completely described by a G-invariant metric of coset manifolds G/H defined by the Snyder algebra. We also discuss a nonlinear deformation of the Snyder algebra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Twisted geometries: A geometric parametrization of SU(2) phase space

A cornerstone of the loop quantum gravity program is the fact that the phase space of general relativity on a fixed graph can be described by a product of SU(2) cotangent bundles per edge. In this paper we show how to parametrize this phase space in terms of quantities describing the intrinsic and extrinsic geometry of the triangulation dual to the graph. These are defined by the assignment to each face of its area, the two unit normals as seen from the two polyhedra sharing it, and an additional angle related to the extrinsic curvature. These quantities do not define a Regge geometry, since they include extrinsic data, but a looser notion of discrete geometry which is twisted in the sense that it is locally well-defined, but the local patches lack a consistent gluing among each other. We give the Poisson brackets among the new variables, and exhibit a symplectomorphism which maps them into the Poisson brackets of loop gravity. The new parametrization has the advantage of a simple description of the gauge-invariant reduced phase space, which is given by a product of phase spaces associated to edges and vertices, and it also provides an Abelianization of the SU(2) connection. The results are relevant for the construction of coherent states and, as a byproduct, contribute to clarify the connection between loop gravity and its subset corresponding to Regge geometries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling Multi-View Impedance-Based Cross-Geometry SOH Estimator for Li-ion Batteries

Abstract: Accurately estimating battery’s State of Health (SOH) remains challenging when models must generalize across cell designs and operating conditions. Most Electrochemical Impedance Spectroscopy (EIS)-based approaches either (i) hand-engineer a few Nyquist-plot features for shallow models—fast but does not generalize across geometries—or (ii) learn directly from Nyquist plots with deep networks, which removes manual feature extraction, yet still limited to a single plot type. As a result, cross-geometry robustness and deployability on constrained Internet of Things (IoT) devices remain open problems. We propose a compact Convolutional Neural Network (CNN) (∼ 10k parameters) that takes multi-representation EIS inputs—Nyquist (real/imaginary) and phase–magnitude (|Z|/ϕ) stacked as four channels, so the model can learn complementary degradation signatures while remaining small enough for fast inference. We build a dataset from cyclic aging of two geometries (LG INR18650MJ1 cylindrical cells and LIR2032 coin cells), acquire EIS every ten cycles from 10 kHz to 10 mHz (10 points/decade), and evaluate with leave-one-cell-out testing strategy. We further study fusion vs. single-representation inputs and assess feasibility for on-device deployment (e.g., NVIDIA Jetson device). The results show that training on multiple EIS representations improves SOH estimation accuracy and cross-geometry generalization compared to single-representation models, which uses only Nyquist or phase–magnitude plots. This design targets accurate, generalizable SOH prediction without manual feature engineering while enabling practical real-time use.

Bakr, Ahmed [The University of Alabama (UA)]↗

Hardware-Accelerated Ray Tracing of CAD-Based Geometry for Monte Carlo Radiation Transport

Monte Carlo radiation transport (MCRT) methods have been used to simulate radiation environments for many decades by tracking individual particles through a model to accumulate statistical information. MCRT geometry is historically formed using the constructive solid geometry (CSG). Recently, significant work has been performed to support simulations using computer-aided design (CAD)-based tessellated surfaces to support highly complex geometries. Ray tracing acceleration data structures from the rendering and visualization community are applied to accelerate particle tracking in CAD-based models. Despite these efforts, CSG representations provide the superior performance in surface intersection operations during particle flight. Concurrently, pseudo Monte Carlo methods have become prevalent in rendering applications to support more realistic models for scattering media, motivating innovations that are advantageous for MCRT simulations. Finally, the authors’ work extends these innovations by employing Intel’s Embree ray tracing kernel within a geometry toolkit for Monte Carlo to improve the simulation performance using CAD-based models by factors of 1.5 to 2.

42 ENGINEERING↗

Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm{sup 2}, the agreement is within 2% for depths up to 10 cm. At 20 cm depth, the in-field maximum dose difference for the 30x30 cm{sup 2} open field is within 4%, while the smaller field sizes agree within 2%. Outside the field size, agreement within 1% of the maximum dose difference is obtained for all fields. The calculated output factors varied from 0.938{+-}0.015 for the 4x4 cm{sup 2} field to 1.088{+-}0.024 for the 40x40 cm{sup 2} field. Their agreement with the experimental output factors is within 1%. Conclusions: The authors have validated a geant4 simulated IAEA-compliant phase space of the TrueBeam linac for the 6 MV beam obtained using a high accuracy geometry implementation from cad. These files are publicly available and can be used for further research.

43 PARTICLE ACCELERATORS↗

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multisource inverse-geometry CT. Part II. X-ray source design and prototype

Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent thermal limitations.

60 APPLIED LIFE SCIENCES↗

SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patient surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed framework might be useful for tasks involving feature-based image registration in range-image guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗