Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gloves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with a curator; other potential future returned samples may require cryogenic curation. Robot arms may be combined with high resolution cameras within a sample cabinet and controlled remotely by curator. Sophisticated robot arm and hand combination systems can be programmed to mimic the movements of a curator wearing a data glove; successful implementation of such a system may ultimately allow a curator to virtually operate in a nitrogen, cryogenic, or biologically sensitive environment with dexterity comparable to that of a curator physically handling samples in a glove box.

Snead, C. J.↗

Initial analysis of “stone” size Ryugu samples: current status

As a part of the initial analysis of the Ryugu samples, we perform a variety of analyses of millimeter-sized "stones". Our goals are to elucidate the entire formation process of C-type asteroid Ryugu from the viewpoint of petrology and mineralogy ande obtain necessary information by sample analysis, and then simulate the formation of Ryugu based on the evidencef obtained rom sample analysis. Eighteen stones (8 from Room A and 10 from Room C) were received from the ISAS curation facility on June 1, 2021, and brought into a fully nitrogen-displaced glove box at Tohoku University. At the same time, we also received the powder samples from Room A and Room C. To completely block the atmosphere from leaking into the container, all samples were put in the sample transport containers prepared by ISAS, transferred from the main chamber to the glovebox at ISAS, and then all containers were completely sealed in plastic bags with moisture and oxygen absorbers. No moisture or oxygen was detected when the bags were opened in the glove box at Tohoku University, so it was confirmed that there was no exposure to the atmosphere during transport. To date, a number of analyses have been carried out successfully and almost on schedule. The analysis started with the measurement of reflectance spectra, which are sensitive to atmospheric oxidation, hydroxylation, and adsorbed water. The visible, near-infrared, and mid-infrared reflectance spectra were measured while the samples were kept airtight. The spectra of powder samples and stone samples (as aggregates and as single stone) were successfully obtained. A major feature of the stone team's analysis is the use of synchrotron radiation facilities around the world. Since this analysis is non-destructive, stone samples whose reflectance spectra were measured were sent to KEK, SPring-8, ESRF (France), SOLEIL (France), DESY (Germany), and APS (USA). Using these synchrotron radiation facilities, high spatial resolution and sensitivity XRD, STXM, XANES, CT [1], IR-CT, FT-IR [2, 3], XRF, and Mössbauer analyses were performed. Most of the analyses were carried out under air-tight conditions on the stone samples and the particulates separated from the stone samples. These analyses allowed us to determine the three-dimensional distribution of minerals and elements, redox state, density and porosity of the stone samples. Furthermore, as a characteristic analysis of the stone team, light elemental analysis using negative Muon was performed at the MLF facility of J-PARC with an exceptionally long allocation of machine time. This is the only non-destructive method to measure the concentration of light elements in the whole (not the surface) of stone samples. Because the characteristic X-rays produced by muon irradiation are much higher in energy than the fluorescent X-rays produced by X-ray irradiation, there is little effect of self-absorption by the sample, and therefore, the concentration of light elements such as carbon, oxygen, and Na in the entire "stone" sample can be determined. Some stone samples are currently being measured for heat and strength physical properties in order to understand the physical properties of asteroid Ryugu. The data obtained from these measurements are useful for interpreting the remote-sensing data data taken from the surface layer of the asteroid Ryugu [4-7]. It is also important for understanding the behavior of the Ryugu material during impact events. The surfaces of many stone samples were observed by electron microscopy and other techniques, especially on natural “flat” surfaces formed on 5 stomes. As a result, characteristric mineral aggregates formed by the reactions with water and characteiristic impact features were observed on some of the samples. Based on the observations of surfaces and the synchrotron measurements of the whole stones, important objects such as characteristic structures and specific crystal aggregates for understanding the formation history of the asteroid were identified, and these parts were separated from the stone samples using an Xe beam (pFIB) and analyzed by various methods including transmission electron microscopy and synchrotron radiation analysis. Many stone samples, from which important objects have been separated, are embedded in epoxy resin and cut to produce many polished sections. Electron microscopy and spectroscopic measurements of the polished surfaces are being carried out to reveal the detailed mineralogical properties and elemental distribution inside the stone samples. In the fall, machine time for synchrotron radiation will begin, and we plan to analyze single crystals and characteristic objects separated from the stone samples.

Tomoki Nakamura↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

Excavation of Exploration Toilet Fecal Canister from ISS Operations and Future Mission Impacts

Space exploration requires accommodations for crew members similar to survival on Earth including food and water, clothing, and protection from the environment. In addition, allowances for biological processes such as breathing, defecation and urination must be provided. In a micro-gravity environment, these are particularly challenging. Optimizing the consumables needed for these activities is a vital part of the spacecraft design as well as providing mass/volume for science cargo and the crew needs such as food and clothing. NASA has collected use rates for the consumables needed for defecation and urination over the decades of human-rated space travel. Most recently, the exploration toilet demonstration on International Space Station (ISS) provided data on defecation in the form of a returned canister which collected 13 days of fecal deposits, wipes, gloves and compaction plates. The canister was excavated by a dedicated team of engineers at Johnson Space Center (JSC) to provide the latest information on deposit size and weight, number of wipes and gloves used, and compaction efficiency which directly relates to the number of canisters needed. Although this is only one canister, the data found has been directly applied to manifest decisions for the Orion Artemis-2 mission. Future canisters will add to this data set. Details on what was found and how it compares to historical numbers as well as how it will be used for exploration missions will be covered in this paper.

Toilet↗

Advances in X-ray Instruments to Support Mars Sample Return

The Mars 2020 Perseverance rover is currently collecting drill cores of ancient igneous and sedimentary rock in and around Jezero crater for potential transport to Earth. These samples from the martian surface will enable detailed mineralogical, geochemical, and petrological measurements to characterize ancient depositional and diagenetic environments, quantitatively age-date the samples, and identify the building blocks for life or evidence for life itself. Furthermore, these drill cores are especially precious because they may represent the most pristine samples from the martian surface and our best chance at identifying martian life, as future sample return missions may be conducted by humans that can introduce biological contaminants to the samples. Because of the importance of these samples, we must take great care in their handling, curation, and preliminary analyses so that they are preserved for scientific measurements for decades to come. In-situ measurements by Perseverance have identified minerals that further warrant special treatment of the returned samples. Hydrated sulfate carbonate, swelling clay minerals, and oxychlorine salts are extremely sensitive to changes in temperature and relative humidity. The structures of hydrated sulfates and oxychlorine minerals, in particular, readily change when exposed to different conditions, meaning the mineral assemblage of the as-returned samples may be lost if the samples aren’t handled properly. Characterizing the as-returned mineral assemblage, particularly of the salts, is essential for reconstructing past aqueous conditions and habitability. To characterize the as-returned mineral assemblage, the samples must be analyzed rapidly before phase changes occur and/or under controlled conditions (e.g., within a glove box). Significant recent advances in X-ray instrumentation for robotic exploration of the solar system have resulted in high-resolution miniaturized instruments that would provide mineralogical, geochemical, and petrological information on the returned martian samples without degradation of the mineral assemblage. Here, we describe a combined X-ray diffractometer/X-ray fluorescence spectrometer (XRD/XRF), an X-ray computed tomographic (XCT) instrument, and a scanned beam XRF mapping instrument that could be used in a glove box so that the martian samples remain under controlled conditions.

E. B. Rampe↗

Excavation of Exploration Toilet Fecal Canister From ISS Operations and Future Mission Impacts

Space exploration requires accommodations for crew members similar to survival on Earth including food and water, clothing, and protection from the environment. In addition, allowances for biological processes such as breathing, defecation and urination must be provided. In a micro-gravity environment, these are particularly challenging. Optimizing the consumables needed for these activities is a vital part of the spacecraft design as well as providing mass/volume for science cargo and the crew needs such as food and clothing. NASA has collected use rates for the consumables needed for defecation and urination over the decades of human-rated space travel. Most recently, the exploration toilet demonstration on International Space Station (ISS) provided data on defecation in the form of a returned canister which collected 13 days of fecal deposits, wipes, gloves and compaction plates. The canister was excavated by a dedicated team of engineers at Johnson Space Center (JSC) to provide the latest information on deposit size and weight, number of wipes and gloves used, and compaction efficiency which directly relates to the number of canisters needed. Although this is only one canister, the data found has been directly applied to manifest decisions for the Orion Artemis-2 mission. Future canisters will add to this data set. Details on what was found and how it compares to historical numbers as well as how it will be used for exploration missions will be covered in this paper.

Toilet↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗

Excavation of Exploration Toilet Fecal Canister from ISS Operations and Future Mission Impacts

Space exploration requires accommodations for crew members similar to survival on Earth including food and water, clothing, and protection from the environment. In addition, allowances for biological processes such as breathing, defecation and urination must be provided. In a micro-gravity environment, these are particularly challenging. Optimizing the consumables needed for these activities is a vital part of the spacecraft design as well as providing mass/volume for science cargo and the crew needs such as food and clothing. NASA has collected use rates for the consumables needed for defecation and urination over the decades of human-rated space travel. Most recently, the exploration toilet demonstration on International Space Station (ISS) provided data on defecation in the form of a returned canister which collected 13 days of fecal deposits, wipes, gloves and compaction plates. The canister was excavated by a dedicated team of engineers at Johnson Space Center (JSC) to provide the latest information on deposit size and weight, number of wipes and gloves used, and compaction efficiency which directly relates to the number of canisters needed. Although this is only one canister, the data found has been directly applied to manifest decisions for the Orion Artemis-2 mission. Future canisters will add to this data set. Details on what was found and how it compares to historical numbers as well as how it will be used for exploration missions will be covered in this paper.

Toilet↗

Boundary-Layer-Transition Measurements in Full-Scale Flight

Chemical sublimation has been employed for boundary-layer-flow visualization on the wings of a supersonic fighter airplane in level flight at speeds near a Mach number of 2.0. The tests have shown that laminar flow can be obtained over extensive areas of the wing with practical wing-surface conditions. In addition to the flow visualization tests, a method of continuously monitoring the conditions of the boundary layer has been applied to flight testing, using heated temperature resistance gages installed in a Fiberglas "glove" installation on one wing. Tests were conducted at speeds from a Mach number of 1.2 to a Mach number of 2.0, at altitudes from 35,000 feet to 56,000 feet. Data obtained at all angles of attack, from near 0 deg to near 10 deg, have shown that the maximum transition Reynolds number on the upper surface of the wing varies from about 2.5 x 10(exp 6) at a Mach number of 1.2 to about 4 x 10(exp 6) at a Mach number of 2.0. On the lower surface, the maximum transition Reynolds number varies from about 2 x 10(exp 6) at a Mach number of 1.2 to about 8 x 10(exp 6) at a Mach number of 2.0.

SUPERSONIC FLOW↗

Special tool kit aids heavily garmented workers

Triangular aluminum tool kit, filled with polyurethane is constructed to receive various tools and hold them in a snug but quick-release fit as an aid to heavily gloved workers. The kit is designed to allow mounting within easily accessable reach and to provide protection of the tools during storage.

Holmes, A. E.↗

An inert gas purity tester

Hot titanium wire measurement of rare gas purity in glove boxes for alkali metal operations

HOT-WIRE MEASUREMENT↗

Degreasing of titanium to minimize stress corrosion

Stress corrosion of titanium and its alloys at elevated temperatures is minimized by replacing trichloroethylene with methanol or methyl ethyl ketone as a degreasing agent. Wearing cotton gloves reduces stress corrosion from perspiration before the metal components are processed.

Carpenter, S. R.↗

Antechamber facilitates loading and unloading of vacuum furnace

Antechamber facilitates the use of a furnace in which materials are heat treated in a high vacuum or a gas atmosphere. It has a high vacuum pumping system, a means for backfilling with a selected gas, an access door, glove ports, and a motor driven platform.

Kramer, P. J.↗

Isothermal drop calorimeter provides measurements for alpha active, pyrophoric materials

Isothermal drop calorimeter measures the heat content of intensely alpha active and pyrophoric materials in inert atmospheres. It consists of a furnace, calorimeter, and aluminum isothermal jacket contained within an inert-atmosphere glove box, which permits the use of unencapsulated materials without exposing personnel to alpha contamination.

Savage, H.↗