Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphical User Interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Neutron Source Facility Training Simulator Based on EPICS

A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

Park, Young Soo↗

NASA Orbital Debris Engineering Model ORDEM2008 (Beta Version)

This is an interim document intended to accompany the beta-release of the ORDEM2008 model. As such it provides the user with a guide for its use, a list of its capabilities, a brief summary of model development, and appendices included to educate the user as to typical runtimes for different orbit configurations. More detailed documentation will be delivered with the final product. ORDEM2008 supersedes NASA's previous model - ORDEM2000. The availability of new sensor and in situ data, the re-analysis of older data, and the development of new analytical techniques, has enabled the construction of this more comprehensive and sophisticated model. Integrated with the software is an upgraded graphical user interface (GUI), which uses project-oriented organization and provides the user with graphical representations of numerous output data products. These range from the conventional average debris size vs. flux magnitude for chosen analysis orbits, to the more complex color-contoured two-dimensional (2-D) directional flux diagrams in terms of local spacecraft pitch and yaw.

Stansbery, Eugene G.↗

A CLIPS/X-window interface

The design and implementation of an interface between the C Language Integrated Production System (CLIPS) expert system development environment and the graphic user interface development tools of the X-Window system are described. The underlying basis of the CLIPS/X-Window is a client-server model in which multiple clients can attach to a single server that interprets, executes, and returns operation results, in response to client action requests. Implemented in an AIX (UNIX) operating system environment, the interface has been successfully applied in the development of graphics interfaces for production rule cooperating agents in a knowledge-based computer aided design (CAD) system. Initial findings suggest that the client-server model is particularly well suited to a distributed parallel processing operational mode in a networked workstation environment.

Pohl, Kym Jason↗

SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

EAGLEView: A surface and grid generation program and its data management

An old and proven grid generation code, the EAGLE grid generation package, is given an added dimension of a graphical interface and a real time data base manager. The Numerical Aerodynamic Simulation (NAS) Panel Library is used for the graphical user interface. Through the panels, EAGLEView constructs the EAGLE script command and sends it to EAGLE to be processed. After the object is created, the script is saved in a mini-buffer which can be edited and/or saved and reinterpreted. The graphical objects are set-up in a linked-list and can be selected or queried by pointing and clicking the mouse. The added graphical enhancement to the EAGLE system emphasizes the unique capability to construct field points around complex geometry and visualize the construction every step of the way.

Remotigue, M. G.↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

JAva GUi for Applied Research (JAGUAR) v 3.0

JAGUAR is a Java software tool for automatically rendering a graphical user interface (GUI) from a structured input specification. It is designed as a plug-in to the Eclipse workbench to enable users to create, edit, and externally execute analysis application input decks and then view the results. JAGUAR serves as a GUI for Sandia's DAKOTA software toolkit for optimization and uncertainty quantification. It will include problem (input deck)set-up, option specification, analysis execution, and results visualization. Through the use of wizards, templates, and views, JAGUAR helps uses navigate the complexity of DAKOTA's complete input specification. JAGUAR is implemented in Java, leveraging Eclipse extension points and Eclipse user interface. JAGUAR parses a DAKOTA NIDR input specification and presents the user with linked graphical and plain text representations of problem set-up and option specification for DAKOTA studies. After the data has been input by the user, JAGUAR generates one or more input files for DAKOTA, executes DAKOTA, and captures and interprets the results

Chan, Ethan↗

The use of hypermedia to increase the productivity of software development teams

Rapid progress in low-cost commercial PC-class multimedia workstation technology will potentially have a dramatic impact on the productivity of distributed work groups of 50-100 software developers. Hypermedia/multimedia involves the seamless integration in a graphical user interface (GUI) of a wide variety of data structures, including high-resolution graphics, maps, images, voice, and full-motion video. Hypermedia will normally require the manipulation of large dynamic files for which relational data base technology and SQL servers are essential. Basic machine architecture, special-purpose video boards, video equipment, optical memory, software needed for animation, network technology, and the anticipated increase in productivity that will result for the introduction of hypermedia technology are covered. It is suggested that the cost of the hardware and software to support an individual multimedia workstation will be on the order of $10,000.

Coles, L. Stephen↗

Draper Station Analysis Tool

Draper Station Analysis Tool (DSAT) is a computer program, built on commercially available software, for simulating and analyzing complex dynamic systems. Heretofore used in designing and verifying guidance, navigation, and control systems of the International Space Station, DSAT has a modular architecture that lends itself to modification for application to spacecraft or terrestrial systems. DSAT consists of user-interface, data-structures, simulation-generation, analysis, plotting, documentation, and help components. DSAT automates the construction of simulations and the process of analysis. DSAT provides a graphical user interface (GUI), plus a Web-enabled interface, similar to the GUI, that enables a remotely located user to gain access to the full capabilities of DSAT via the Internet and Webbrowser software. Data structures are used to define the GUI, the Web-enabled interface, simulations, and analyses. Three data structures define the type of analysis to be performed: closed-loop simulation, frequency response, and/or stability margins. DSAT can be executed on almost any workstation, desktop, or laptop computer. DSAT provides better than an order of magnitude improvement in cost, schedule, and risk assessment for simulation based design and verification of complex dynamic systems.

Bedrossian, Nazareth↗

Interface design of VSOP'94 computer code for safety analysis

Today, most software applications, also in the nuclear field, come with a graphical user interface. VSOP'94 (Very Superior Old Program), was designed to simplify the process of performing reactor simulation. VSOP is a integrated code system to simulate the life history of a nuclear reactor that is devoted in education and research. One advantage of VSOP program is its ability to calculate the neutron spectrum estimation, fuel cycle, 2-D diffusion, resonance integral, estimation of reactors fuel costs, and integrated thermal hydraulics. VSOP also can be used to comparative studies and simulation of reactor safety. However, existing VSOP is a conventional program, which was developed using Fortran 65 and have several problems in using it, for example, it is only operated on Dec Alpha mainframe platforms and provide text-based output, difficult to use, especially in data preparation and interpretation of results. We develop a GUI-VSOP, which is an interface program to facilitate the preparation of data, run the VSOP code and read the results in a more user friendly way and useable on the Personal 'Computer (PC). Modifications include the development of interfaces on preprocessing, processing and postprocessing. GUI-based interface for preprocessing aims to provide a convenience way in preparing data. Processing interface is intended to provide convenience in configuring input files and libraries and do compiling VSOP code. Postprocessing interface designed to visualized the VSOP output in table and graphic forms. GUI-VSOP expected to be useful to simplify and speed up the process and analysis of safety aspects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DIVA/DeviceEditor (DIVA) v5.1

The DIVA software interfaces a process in which researchers design their DNA with a web-based graphical user interface (DeviceEditor), submit their designs to a central queue, and a few weeks later receive their sequence-verified clonal constructs. Each researcher independently designs the DNA to be constructed with a web-based BioCAD tool, and presses a button to submit their designs to a central queue. Researchers have web-based access to their DNA design queues, and can track the progress of their submitted designs as they progress from "evaluation", to "waiting for reagents", to "in progress", to "complete". Researchers access their completed constructs through the central DNA repository. Along the way, all DNA construction success/failure rates are captured in a central database. his success/failure rate data can be leveraged to refine the DNA assembly design process.

Lane, Stephen↗

DIVA/DeviceEditor (DIVA) v6.0.0

The DIVA software interfaces a process in which researchers design their DNA with a web-based graphical user interface (DeviceEditor), submit their designs to a central queue, and a few weeks later receive their sequence-verified clonal constructs. Each researcher independently designs the DNA to be constructed with a web-based BioCAD tool, and presses a button to submit their designs to a central queue. Researchers have web-based access to their DNA design queues, and can track the progress of their submitted designs as they progress from "evaluation", to "waiting for reagents", to "in progress", to "complete". Researchers access their completed constructs through the central DNA repository. Along the way, all DNA construction success/failure rates are captured in a central database. Once a design has been submitted to the queue, a small number of dedicated staff evaluate the design for feasibility and provide feedback to the responsible researcher if the design is either unreasonable (e.g., encompasses a combinatorial library of a billion constructs) or small design changes could significantly facilitate the downstream implementation process. The dedicated staff then use DNA assembly design automation software to optimize the DNA construction process for the design, leveraging existing parts from the DNA repository where possible and ordering synthetic DNA where necessary. Once all requisite process inputs are available, the design progresses from "waiting for reagents" to "in progress" in the design queue. Human-readable and machine-parseable DNA construction protocols output by the DNA assembly design automation software are then executed by the dedicated staff exploiting lab automation devices wherever possible. Since the all employed DNA construction methods are sequence-agnostic, standardized (utilize the same enzymatic master mixes and reaction conditions), completely independent DNA construction tasks can be aggregated into the same multi-well plates and pursued in parallel. The resulting sets of cloned constructs can then be screened by high-throughput next-gen sequencing platforms for sequence correctness. A combination of long read-length (e.g., PacBio) and paired-end read platforms (e.g., Illumina) would be exploited depending the particular task at hand (e.g., PacBio might be sufficient to screen a set of pooled constructs with significant gene divergence). Post sequence verification, designs for which at least one correct clone was identified will progress to a "complete" status, while designs for which no correct clones were identified will progress to a "failure" status. Depending on the failure mode (e.g., no transformants), and how many prior attempts/variations of assembly protocol have been already made for a given design, subsequent attempts may be made or the design can progress to a "permanent failure" state. All success and failure rate information will be captured during the process, including at which stage a given clonal construction procedure failed (e.g., no PCR product) and what the exact failure was (e.g. assembly piece 2 missing). This success/failure rate data can be leveraged to refine the DNA assembly design process.

Plahar, Hector↗

Software for Improved Extraction of Data From Tape Storage

A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

Cheng, Chiu-Fu↗

Software for Improved Extraction of Data From Tape Storage

A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

Cheng, Chiu-Fu↗

Software for Improved Extraction of Data From Tape Storage

A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are used at Stennis Space Center. The original software could be activated by a command- line interface only; the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

Cheng, Chiu-Fu↗

Plant Habitat Telemetry / Command Interface and E-MIST

Plant Habitat (PH) is an experiment to be taken to the International Space Station (ISS) in 2016. It is critical that ground support computers have the ability to uplink commands to control PH, and that ISS computers have the ability to downlink PH telemetry data to ground support. This necessitates communication software that can send, receive, and process, PH specific commands and telemetry. The objective of the Plant Habitat Telemetry/ Command Interface is to provide this communication software, and to couple it with an intuitive Graphical User Interface (GUI). Initial investigation of the project objective led to the decision that code be written in C++ because of its compatibility with existing source code infrastructures and robustness. Further investigation led to a determination that multiple Ethernet packet structures would need to be created to effectively transmit data. Setting a standard for packet structures would allow us to distinguish these packets that would range from command type packets to sub categories of telemetry packets. In order to handle this range of packet types, the conclusion was made to take an object-oriented programming approach which complemented our decision to use the C++ programming language. In addition, extensive utilization of port programming concepts was required to implement the core functionality of the communication software. Also, a concrete understanding of a packet processing software was required in order to put aU the components of ISS-to-Ground Support Equipment (GSE) communication together and complete the objective. A second project discussed in this paper is Exposing Microbes to the Stratosphere (EMIST). This project exposes microbes into the stratosphere to observe how they are impacted by atmospheric effects. This paper focuses on the electrical and software expectations of the project, specifically drafting the printed circuit board, and programming the on-board sensors. The Eagle Computer-Aided Drafting (CAD) software was used to draft the E-MIST circuit. This required several component libraries to be created. Coding the sensors and obtaining sensor data involved using the Arduino Uno developmental board and coding language, and properly wiring peripheral sensors to the microcontroller (the central control unit of the experiment).

Walker, Uriae M.↗

DIVA V1.0

The DIVA software interfaces a process in which researchers design their DNA with a web-based graphical user interface, submit their designs to a central queue, and a few weeks later receive their sequence-verified clonal constructs. Each researcher independently designs the DNA to be constructed with a web-based BioCAD tool, and presses a button to submit their designs to a central queue. Researchers have web-based access to their DNA design queues, and can track the progress of their submitted designs as they progress from "evaluation", to "waiting for reagents", to "in progress", to "complete". Researchers access their completed constructs through the central DNA repository. Along the way, all DNA construction success/failure rates are captured in a central database. Once a design has been submitted to the queue, a small number of dedicated staff evaluate the design for feasibility and provide feedback to the responsible researcher if the design is either unreasonable (e.g., encompasses a combinatorial library of a billion constructs) or small design changes could significantly facilitate the downstream implementation process. The dedicated staff then use DNA assembly design automation software to optimize the DNA construction process for the design, leveraging existing parts from the DNA repository where possible and ordering synthetic DNA where necessary. SynTrack software manages the physical locations and availability of the various requisite reagents and process inputs (e.g., DNA templates). Once all requisite process inputs are available, the design progresses from "waiting for reagents" to "in progress" in the design queue. Human-readable and machine-parseable DNA construction protocols output by the DNA assembly design automation software are then executed by the dedicated staff exploiting lab automation devices wherever possible. Since the all employed DNA construction methods are sequence-agnostic, standardized (utilize the same enzymatic master mixes and reaction conditions), completely independent DNA construction tasks can be aggregated into the same multi-well plates and pursued in parallel. The resulting sets of cloned constructs can then be screened by high-throughput next-gen sequencing platforms for sequence correctness. A combination of long read-length (e.g., PacBio) and paired-end read platforms (e.g., Illumina) would be exploited depending the particular task at hand (e.g., PacBio might be sufficient to screen a set of pooled constructs with significant gene divergence). Post sequence verification, designs for which at least one correct clone was identified will progress to a "complete" status, while designs for which no correct clones wereidentified will progress to a "failure" status. Depending on the failure mode (e.g., no transformants), and how many prior attempts/variations of assembly protocol have been already made for a given design, subsequent attempts may be made or the design can progress to a "permanent failure" state. All success and failure rate information will be captured during the process, including at which stage a given clonal construction procedure failed (e.g., no PCR product) and what the exact failure was (e.g. assembly piece 2 missing). This success/failure rate data can be leveraged to refine the DNA assembly design process.

Source record↗

DIVA V2.0

The DIVA software interfaces a process in which researchers design their DNA with a web-based graphical user interface, submit their designs to a central queue, and a few weeks later receive their sequence-verified clonal constructs. Each researcher independently designs the DNA to be constructed with a web-based BioCAD tool, and presses a button to submit their designs to a central queue. Researchers have web-based access to their DNA design queues, and can track the progress of their submitted designs as they progress from "evaluation", to "waiting for reagents", to "in progress", to "complete". Researchers access their completed constructs through the central DNA repository. Along the way, all DNA construction success/failure rates are captured in a central database. Once a design has been submitted to the queue, a small number of dedicated staff evaluate the design for feasibility and provide feedback to the responsible researcher if the design is either unreasonable (e.g., encompasses a combinatorial library of a billion constructs) or small design changes could significantly facilitate the downstream implementation process. The dedicated staff then use DNA assembly design automation software to optimize the DNA construction process for the design, leveraging existing parts from the DNA repository where possible and ordering synthetic DNA where necessary. SynTrack software manages the physical locations and availability of the various requisite reagents and process inputs (e.g., DNA templates). Once all requisite process inputs are available, the design progresses from "waiting for reagents" to "in progress" in the design queue. Human-readable and machine-parseable DNA construction protocols output by the DNA assembly design automation software are then executed by the dedicated staff exploiting lab automation devices wherever possible. Since the all employed DNA construction methods are sequence-agnostic, standardized (utilize the same enzymatic master mixes and reaction conditions), completely independent DNA construction tasks can be aggregated into the same multi-well plates and pursued in parallel. The resulting sets of cloned constructs can then be screened by high-throughput next-gen sequencing platforms for sequence correctness. A combination of long read-length (e.g., PacBio) and paired-end read platforms (e.g., Illumina) would be exploited depending the particular task at hand (e.g., PacBio might be sufficient to screen a set of pooled constructs with significant gene divergence). Post sequence verification, designs for which at least one correct clone was identified will progress to a "complete" status, while designs for which no correct clones wereidentified will progress to a "failure" status. Depending on the failure mode (e.g., no transformants), and how many prior attempts/variations of assembly protocol have been already made for a given design, subsequent attempts may be made or the design can progress to a "permanent failure" state. All success and failure rate information will be captured during the process, including at which stage a given clonal construction procedure failed (e.g., no PCR product) and what the exact failure was (e.g. assembly piece 2 missing). This success/failure rate data can be leveraged to refine the DNA assembly design process.

CHEN, JOANNA↗