Failure analysis of a graphite/epoxy laminate subjected to bolt-bearing loads

Quasi-isotropic graphite-epoxy laminates (T300/5208) were tested under bolt bearing loads to study failure modes, strengths, and failure energy. Specimens had a range of configurations to produce failures by the three nominal failure modes: tension, shearout, and bearing. Radiographs were made after damage onset and after ultimate load to examine the failure modes. Also, the laminate stresses near the bolt hole calculated for each test specimen configuration, and then used with a failure criterion to analyze the test data. Failures involving extensive bearing damage were found to dissipate significantly more energy than tension dominated failures. The specimen configuration influenced the failure modes and therefore also influenced the failure energy. In the width-to-diameter ratio range of 4 to 5, which is typical of structural joints, a transition from the tension mode to the bearing mode was shown to cause a large increase in failure energy. The failure modes associated with ultimate strength were usually different from those associated with the damage onset. Typical damage sequences involved bearing damage onset at the hole boundary followed by tension damage progressing from the hole boundary.

Crews, J. H., Jr.↗

New experimental and analytical results for diffusion and swelling of resins used in graphite/epoxy composite materials

The epoxy resins currently in use can slowly absorb moisture from the atmosphere over a long period. This reduces those mechanical properties of composites which depend strongly on the matrix, such as compressive strength and buckling instabilities. The effect becomes greater at elevated temperatures. The paper will discuss new phenomena which occur under simultaneous temperature and moisture variations. An analytical model will also be discussed and documented.

Hiel, C. C.↗

An in-situ study in SEM of delamination in several graphite/epoxy composite material systems

A three point bend fixture compatible with the current loading stage for the Scanning Electron Microscope was designed and fabricated. End-notched flexure tests were run on several materials. Work to date was on AS4/3502, T6T145/F155, and T6T145/F185. Fracture toughness was measured. Fracture of neat resin specimens was begun. The decrease in delaminatin fracture toughness, compared to neat resin toughness, due to rigid fiber filler and interlaminar failure is addressed. An experimental program was designed to try to determine the proper interpretatin for apparent microcracking in neat resin specimens.

Bradley, W. L.↗

Investigation of non-linear contact for a clearance-fit bolt in a graphite/epoxy laminate

Numerous analytical studies have been published for the nonlinear load-contact variations in clearance-fit bolted joints. In these studies, stress distributions have been obtained and failure predictions have been made. However, very little experimental work has been reported regarding the contact or the stresses. This paper describes a fiber-optic technique for measuring the angle of contact in a clearance-fit bolt-loaded hole. Measurements of the contact angle have been made in a quasi-isotropic graphite-epoxy laminate by the optical as well as an electrical technique, and the results have been compared with those obtained from a finite-element analysis. The results from the two experimental techniques show excellent agreement; the finite-element results show some discrepancy, probably due to the interfacial frictions.

Prabhakaran, R.↗

Method for hygromechanical characterization of graphite/epoxy composite

An experimental method is described for measuring hygroscopic swelling strains and mechanical strains of moisture-conditioned composite specimens. The method consists of embedding encapsulated strain gages in the midplane of the composite laminate; thus it does not interfere with normal moisture diffusion. It is particularly suited for measuring moisture swelling coefficients and for mechanical testing of moisture-conditioned specimens at high strain rates. Results obtained by the embedded gage method were shown to be more reliable and reproducible than those obtained by surface gages, dial gages, or extensometers.

Yaniv, Gershon↗

Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

Bigelow, C. A.↗

Development and properties of aluminum-clad graphite/epoxy tubes for space structures

This paper presents the development and properties of seamless aluminum-clad P75/Epoxy tubes and the unique manufacturing method used in their production. Thermo-mechanical properties of the tubes were determined analytically and verified by tests. These properties were shown to be suitable for space structures that require high stiffness, low weight and thermal expansion, and dimensional stability during operational life. A special feature of the tubes is the ability to tune the tube for thermal expansion after fabrication by a chemical milling process. The tubes are also resistant to atomic oxygen and handling damage. The toughness of the tubes was demonstrated by impact testing. Cyclic thermal testing showed no adverse effects on the expansion and stiffness behavior of the tubes. The paper also includes a discussion of a joining method that uses aluminum end fittings and an efficient scarf joint configuration. Additional studies considered various adhesives and fitting materials. Joint allowables were higher for titanium and B4C particulate magnesium fittings. The effect of different adhesives under static loading conditions favored the high-strength adhesives.

Johnson, R. R.↗

Effect of axial impact on the static flexure of graphite/epoxy beams

Graphite-epoxy beams were subjected to an eccentric axial impact load in a drop tower test fixture in order to study their large displacement flexural behavior. The time history of the transient axial load exhibited a large magnitude occurring just after impact, which was many times greater than the static failure load. The damage caused by this peak dynamic load was measured by the reduction in energy absorption of the impacted beam relative to a virgin beam in static tests. For the thirty-ply specimens, the amount of damage increased with increasing axial stiffness.

Sensmeier, M. D.↗

Thermal cycling effects on the dimensional stability of P75 and P75-T300 (fabric) hybrid graphite/epoxy laminates

The response of cross-ply P75/934 laminates and hybrid laminates consisting of P75/934 unidirectional tape and T300/934 woven fabric were compared for temperature exposures between + and - 250 F up to a maximum of 250 cycles. The properties monitored included microcrack density, coefficient of thermal expansion (CTE), residual strain, and tensile modulus. Hybrid laminates, with stiffnesses and CTE's comparable to P75/934 cross-ply laminates, demonstrated significantly improved thermal cycling stability in one direction. The hybrid laminates also had predicted longitudinal properties comparable to low angle, off-axis P75/934 configurations, but had significantly higher predicted transverse strengths. T300 Gr/Ep plain-weave fabric laminates were shown to be much less susceptible to thermal cycling damage than T300 Gr/Ep cross-ply laminates. None of the laminates tested exhibited any significant changes in tensile modulus after thermal cycling.

Bowles, David E.↗

Sustained load behavior of graphite/epoxy metal-lined pressure vessels for long-life space applications

Tests were performed on candidate graphite yarns for the overwraps to be used on the Space Station Freedom's pressure vessels. The objective was to determine the performance and ranking of these overwraps to ensure that sustained loads would not be a problem during their 30-yr life in space. Tests were conducted at high stress levels for short time periods on subscale composite bottles. The average delivered fiber stresses were determined from the measured burst pressures via SCI analysis that accounts for both geometry and the properties of the resin and yarn.

Babel, H. W.↗

High-toughness graphite/epoxy composite material experiment

The experiment was designed to measure the effect of near-space exposure on mechanical properties of specially toughened 5208/T300 graphite-epoxy composites. The properties measured are elastic modulus, strength, and fracture toughness. Specimens were mounted on an external frame during the time of the LDEF mission. Specimen variables include angle of adjacent plies and fraction of interlaminar contact, which is controlled by the fraction of finely spaced holes in Mylar film placed between the prepreg monolayers of the composite.

Felbeck, David K.↗

Damage development under compression-compression fatigue loading in a stitched uniwoven graphite/epoxy composite material

Damage initiation and growth under compression-compression fatigue loading were investigated for a stitched uniweave material system with an underlying AS4/3501-6 quasi-isotropic layup. Performance of unnotched specimens having stitch rows at either 0 degree or 90 degrees to the loading direction was compared. Special attention was given to the effects of stitching related manufacturing defects. Damage evaluation techniques included edge replication, stiffness monitoring, x-ray radiography, residual compressive strength, and laminate sectioning. It was found that the manufacturing defect of inclined stitches had the greatest adverse effect on material performance. Zero degree and 90 degree specimen performances were generally the same. While the stitches were the source of damage initiation, they also slowed damage propagation both along the length and across the width and affected through-the-thickness damage growth. A pinched layer zone formed by the stitches particularly affected damage initiation and growth. The compressive failure mode was transverse shear for all specimens, both in static compression and fatigue cycling effects.

Vandermey, Nancy E.↗

The durability of graphite/epoxy laminate subjected to repeated low velocity impact

Low velocity impact has been considered as quasi-static loading, as the dynamic effects are decaying before the pressure reaches its maximum. However, when the impact energy is low enough as not to cause visible damage, the dynamic effect at the beginning of the impact may cause internal damage to the laminate. Laminates were loaded quasi-statically and by impact to the same bending strain and with the same indenter shape several times. The laminates that were subjected to the impact loading failed much more rapidly. Analysis of the problem shows that the stress waves created by the impact at the beginning of contact intensify the damage zone created by the preceding impact until the final failure occurs.

Rotem, A.↗

The propagation characteristics of the plate modes of acoustic emission waves in thin aluminum plates and thin graphite/epoxy composite plates and tubes

Acoustic emission was interpreted as modes of vibration in plates. Classical plate theory was used to predict dispersion curves for the two fundamental modes and to calculate the shapes of flexural waveforms produced by vertical step function loading. There was good agreement between theoretical and experimental results for aluminum. Composite materials required the use of a higher order plate theory (Reissner-Mindlin) to get good agreement with the measured velocities. Four composite plates with different laminate stacking sequences were studied. The dispersion curves were determined from phase spectra of the time dependent waveforms. Plate modes were shown to be useful for determining the direction of source motion. Aluminum plates were loaded by breaking a pencil lead against their surface. By machining slots at angles to the plane of a plate, the direction in which the force acted was varied. Changing the source motion direction produced regular variations in the waveforms. To demonstrate applicability beyond simple plates, waveforms produced by lead breaks on a thin walled composite tube were also shown to be interpretable as plate modes. The tube design was based on the type of struts proposed for Space Station Freedom's trussed structures.

Prosser, William H.↗

Temperature effects on high strain rate properties of graphite/epoxy composites

A unidirectional graphite epoxy material (AS4/3501-6) was characterized at strain rates ranging from 5 x 10(exp 6) s(exp -1) to 5(exp -1), at room temperature and at 128 C. Results are presented in the form of stress-strain curves to failure. The longitudinal properties remain nearly unchanged with strain rate and temperature. The transverse modulus increases with strain rate but decreases with temperature. The transverse strength and transverse ultimate tensile strain have a positive rate sensitivity at low rates, which changes to negative at intermediate rates and returns to positive rate sensitivity at the highest rates tested. A temperature-time equivalence principle was applied and master curves were obtained for the transverse mechanical properties. The in-plane shear modulus and in-plane shear strength have a positive rate sensitivity. The ultimate intralaminar shear strain has a positive rate sensitivity at low rates, which changes to negative at high rates. At the elevated temperature of 128 C, the ultimate shear strain is 25 to 30 percent higher than the room temperature value, but its strain rate dependence is moderate.

Yaniv, G.↗