Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating matrices for arbitrarily spaced grid points

Integrating matrices are derived for arbitrarily spaced grid points using either interpolating or least squares fit orthogonal polynomials. Several features of the equally spaced grid case are also discussed.

Lakin, W. D.↗

Trajectory Optimization: OTIS 4

The latest release of the Optimal Trajectories by Implicit Simulation (OTIS4) allows users to simulate and optimize aerospace vehicle trajectories. With OTIS4, one can seamlessly generate optimal trajectories and parametric vehicle designs simultaneously. New features also allow OTIS4 to solve non-aerospace continuous time optimal control problems. The inputs and outputs of OTIS4 have been updated extensively from previous versions. Inputs now make use of objectoriented constructs, including one called a metastring. Metastrings use a greatly improved calculator and common nomenclature to reduce the user s workload. They allow for more flexibility in specifying vehicle physical models, boundary conditions, and path constraints. The OTIS4 calculator supports common mathematical functions, Boolean operations, and conditional statements. This allows users to define their own variables for use as outputs, constraints, or objective functions. The user-defined outputs can directly interface with other programs, such as spreadsheets, plotting packages, and visualization programs. Internally, OTIS4 has more explicit and implicit integration procedures, including high-order collocation methods, the pseudo-spectral method, and several variations of multiple shooting. Users may switch easily between the various methods. Several unique numerical techniques such as automated variable scaling and implicit integration grid refinement, support the integration methods. OTIS4 is also significantly more user friendly than previous versions. The installation process is nearly identical on various platforms, including Microsoft Windows, Apple OS X, and Linux operating systems. Cross-platform scripts also help make the execution of OTIS and post-processing of data easier. OTIS4 is supplied free by NASA and is subject to ITAR (International Traffic in Arms Regulations) restrictions. Users must have a Fortran compiler, and a Python interpreter is highly recommended.

Riehl, John P.↗

Microcoil Spring Interconnects for Ceramic Grid Array Integrated Circuits

As integrated circuit miniaturization trends continue, they drive the need for smaller higher input/output (I/O) packages. Hermetically sealed ceramic area array parts are the package of choice by the space community for high reliability space flight electronic hardware. Unfortunately, the coefficient of thermal expansion mismatch between the ceramic area array package and the epoxy glass printed wiring board limits the life of the interconnecting solder joint. This work presents the results of an investigation by Marshall Space Flight Center into a method to increase the life of this second level interconnection by the use of compliant microcoil springs. The design of the spring and its attachment process are presented along with thermal cycling results of microcoil springs (MCS) compared with state-of-the-art ball and column interconnections. Vibration testing has been conducted on MCS and high lead column parts. Radio frequency simulation and measurements have been made and the MCS has been modeled and a stress analysis performed. Thermal cycling and vibration testing have shown MCS interconnects to be significantly more reliable than solder columns. Also, MCS interconnects are less prone to handling damage than solder columns. Future work that includes shock testing, incorporation into a digital signal processor board, and process evaluation of expansion from a 400 I/O device to a device with over 1,100 I/O is identified.

Strickland, S. M.↗

Distributed hierarchical control architecture for integrating smart grid assets during normal and disrupted operations

Disclosed herein are representative embodiments of methods, apparatus, and systems for facilitating operation and control of a resource distribution system (such as a power grid). Among the disclosed embodiments is a distributed hierarchical control architecture (DHCA) that enables smart grid assets to effectively contribute to grid operations in a controllable manner, while helping to ensure system stability and equitably rewarding their contribution. Embodiments of the disclosed architecture can help unify the dispatch of these resources to provide both market-based and balancing services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.