Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH PASS FILTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Advanced Sine Wave Modulation of Continuous Wave Laser System for Atmospheric CO2 Differential Absorption Measurements

NASA Langley Research Center in collaboration with ITT Exelis have been experimenting with Continuous Wave (CW) laser absorption spectrometer (LAS) as a means of performing atmospheric CO2 column measurements from space to support the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission.Because range resolving Intensity Modulated (IM) CW lidar techniques presented here rely on matched filter correlations, autocorrelation properties without side lobes or other artifacts are highly desirable since the autocorrelation function is critical for the measurements of lidar return powers, laser path lengths, and CO2 column amounts. In this paper modulation techniques are investigated that improve autocorrelation properties. The modulation techniques investigated in this paper include sine waves modulated by maximum length (ML) sequences in various hardware configurations. A CW lidar system using sine waves modulated by ML pseudo random noise codes is described, which uses a time shifting approach to separate channels and make multiple, simultaneous online/offline differential absorption measurements. Unlike the pure ML sequence, this technique is useful in hardware that is band pass filtered as the IM sine wave carrier shifts the main power band. Both amplitude and Phase Shift Keying (PSK) modulated IM carriers are investigated that exibit perfect autocorrelation properties down to one cycle per code bit. In addition, a method is presented to bandwidth limit the ML sequence based on a Gaussian filter implemented in terms of Jacobi theta functions that does not seriously degrade the resolution or introduce side lobes as a means of reducing aliasing and IM carrier bandwidth.

Campbell, Joel F.↗

Hand-Held Color Meters Based on Interference Filters

Small, inexpensive, hand-held optoelectronic color-measuring devices based on metal-film/dielectric-film interference filters are undergoing development. These color meters could be suitable for use in a variety of applications in which there are requirements to quantify or match colors for aesthetic purposes but there is no need for the high spectral resolution of scientific-grade spectrometers. Such applications typically occur in the paint, printing, and cosmetic industries, for example. The figure schematically depicts a color meter of this type being used to measure the color of a sample in terms of the spectrum of light reflected from the sample. Light from a white source (for example, a white light-emitting diode) passes through a collimating lens to the sample. Another lens collects some of the light reflected from the sample and focuses the light onto the input end of optical fiber. Light emerging from the output end of the optical fiber illuminates an array of photodetectors covered with metal/dielectric-film interference filters like those described in Metal/Dielectric-film Interference Color Filters (NPO-20217), NASA Tech Briefs, Vol. 23, No. 2 (February 1999), page 70. Typically, these are wide-band-pass filters, as shown at the bottom of the figure. The photodetector array need not be of any particular design: it could be something as simple as an assembly containing several photodiodes or something as elaborate as an active-pixel sensor or other imaging device. What is essential is that each of the photodetectors or each of several groups of photodetectors is covered with a metal/dielectric-film filter of a different color. In most applications, it would be desirable to have at least three different filters, each for a spectral band that contains one of the three primary additive red, green, and blue colors. In some applications, it may be necessary to have more than three different color filters in order to characterize subtle differences in color (or in the sensation of color) that cannot be characterized with sufficient precision by use of the primary colors alone.

Snyder, G. Jeffrey↗

HIFOGS: Its design, operations and calibration

The High-efficiency, Infrared Faint Object Grating Spectrometer (HIFOGS) provides spectral coverage of selectable portions of the 3 to 18 micron range at resolving powers from 00 to 1000 using 120 Si/Bi detectors. Additional coverage to 30 microns is provided by a bank of 32 Si:P detectors. Selectable apertures, gratings and band-pass filters provide flexibility to this system. Software for operation of HIFOGS and reduction of the data runs on a MacIntosh computer. HIFOGS has been used to establish celestial flux standards using 3 independent approaches: comparison to star models, comparisons to asteroid models and comparisons to laboratory blackbodies. These standards are expected to have wide application in astronomical thermal-infrared spectroscopy.

Witteborn, Fred C.↗

High-gradient magnetic separation of colloidal uranium oxide particles from soil components in aqueous suspensions

The separation of uranium oxide (UO 2 ) particles from soil-surrogate particles in aqueous suspensions was achieved using filtration enhanced by a magnetic field. Enhanced attraction of paramagnetic UO 2 colloids to a ferromagnetic stainless-steel filter placed in a strong magnetic field arises because of the positive magnetic susceptibility of the particles and the high-gradient field generated near ferromagnetic fibers. Enhanced uptake of smaller particles over larger ones occurs through Brownian motion that promotes the collision of particles with the ferromagnetic fibers of the filter. Hence, this work focused on UO 2 particles in the colloidal size range. Experiments used a water-cooled electromagnet and an array of permanent magnets. Chemical analysis showed that the magnetic field increased the capture efficiency of uranium particles from a range of 27–53% with the magnet off up to 98% with the magnet on after a single pass of the suspension through the filter. Further, the recovery of the UO 2 particles from the filter, however, was more difficult to achieve. Small amounts of UO 2 , together with significant amounts of background SiO 2 particles, were removed from the filter during a first flush with the magnetic field on. A much larger recovery of UO 2 was not observed until a second out-of-field flush was performed, which also released some SiO 2 . The degree to which particle separation was enhanced through the use of multi-stage filtration compared to single pass-through filtration was also examined. A design was suggested that could be used to optimize the separation efficiency for a continuous process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparing smoothing techniques for extracting MOSFET threshold voltage

Measurement noise acts as a barrier to the accurate calculation of threshold voltage by derivative-based extraction methods. We examined several smoothing techniques and their effects on measurement noise in threshold voltage extracted by the linear extrapolation method and the g m /I d method. We applied these techniques on a set of SiC power MOSFET devices before and after they had undergone accelerated thermal testing. The smoothing methods examined are least-squares polynomial fitting, low-pass filtering using Butterworth and Chebyshev fillers, and differential smoothing. These methods are compared by their shift in threshold voltage compared to unsmoothed data and their standard deviation among the measurements of each device. All methods performed poorly at smoothing when extracting via the g m /I d due to the large amounts of high-magnitude subthreshold noise, mostly tending to extract threshold voltages far below the expected value. Differential smoothing provided results closest to the expected value with an absolute shift of 1.2 V on average. The smoothing methods performed better with the LE method. On a failed device, all smoothing methods except polynomial smoothing preserved the large threshold voltage anomaly for four out of five measurements. These results show that choice of smoothing method, if used must be evaluated based on the device and extraction method.

42 ENGINEERING↗

Coplanar waveguide microwave filter of YBa2Cu3O7

Thin film low-pass microwave filters have been made with laser-ablated YBa2Cu3O(7-delta) (YBCO) deposited on LaAlO3 substrates, using a coplanar waveguide structure. The coplanar waveguide sections had dimensions suited for integrated circuits. Measured losses in liquid nitrogen were superior to the loss in a similar thin-film copper filter throughout the 0 to 9.5 GHz pass-band. A simple transmission-line model is adequate for filter design using YBCO films with repeatable characteristics. The measured filters demonstrate the performance of fully patterned YBCO after sealing in space-qualifiable hermetic packages. Five packaged filters of this design were delivered to the Naval Research Laboratory as candidates for space flight in the High Temperature Superconductivity Space Experiment.

Chew, Wilbert↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using the Diurnal Variability in GeoNEX TOA Reflectances for Earth Monitoring

Observations from the third-generation geostationary satellite instruments (GOES 16/17 ABI, Himawari 8/9 AHI, and etc.) have spatial resolution and spectral band configurations comparable to flagship LEO sensors (e.g., MODIS/VIIRS). More importantly, these data are acquired at very high temporal resolution, faithfully recording the variations of the full disk of Earth at every 5-10 minutes. They thus provide unique information about Earth’s atmosphere and surface. In order to explore the unique information content of geostationary data, this study systematically analyzes the diurnal variability in the GeoNEX L1G TOA reflectance products and compares them to simulated results by state-of-the-art radiative transfer codes. Our results show that • The smoothness of the TOA reflectance diurnal cycle provides a convenient and reliable way to identify stable atmospheric conditions and filter out passing clouds/shadows. • The diurnal variability of the blue band (0.47µm) reflectance is regulated mainly by atmospheric optical conditions over a majority of land cover types. As such, the diurnal variability of the blue band data allows us to retrieve AOD without invoking the use of spectral band ratios (SRC) as in previous algorithms. • In comparison, the diurnal variability of the short-wave infrared band (2.2µm) BRFs is mainly regulated by surface reflectance and the sun-target-satellite geometry. This information allows us to test and, if suitable, retrieve surface BRDF parameters. • Spectral band ratios, especially those between the 2.2µm and 0.47µm bands, are not constant but vary by locations and sun-target-satellite geometries. Our analysis clearly demonstrates that the information provided in high-frequent geostationary observations is unique and complementary to LEO sensors. Therefore, a synergy of GEO and LEO (and other) sensors has the great potential to improve existing remote sensing models and algorithms for better Earth monitoring.

Diurnal Variability↗

Analysis of signal to noise enhancement using a highly selective modulation tracking filter

Experiments are reported which utilize photodielectric effects in semiconductor loaded superconducting resonant circuits for suppressing noise in RF communication systems. The superconducting tunable cavity acts as a narrow band tracking filter for detecting conventional RF signals. Analytical techniques were developed which lead to prediction of signal-to-noise improvements. Progress is reported in optimization of the experimental variables. These include improved Q, new semiconductors, improved optics, and simplification of the electronics. Information bearing signals were passed through the system, and noise was introduced into the computer model.

Haden, C. R.↗

Advanced microbial check valve development

A flight certified assembly identified as a Microbial Check Valve (MCV) was developed and tested. The MCV is a canister packed with an iodinated anionic exchange resin. The device is used to destroy organisms in a water stream as the water passes through the device. The device is equally effective for fluid flow in either direction and its primary method of organism removal is killing rather than filtering. The MCV was successfully developed for the space shuttle to: disinfect fuel cell water; and prevent back contamination of the stored potable water supply. One version of the device consists of a high residual iodinated resin bed that imparts approximately 2 ppm of iodine to the fuel cell water as it flows to the potable water tanks. A second version of the device consists of a low residual iodinated resin bed. One of these low residual beds is located at each use port in the potable water system for the dual purpose of removing some iodine from the potable water as it is dispensed and also to prevent back contamination of the potable supply.

Colombo, G. V.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity and Temperature

A new technique for measuring dynamic gas velocity and temperature is described. The technique is based on molecular Rayleigh scattering of laser light, so no seeding of the flow is necessary. The Rayleigh scattered light is filtered with a fixed cavity, planar mirror Fabry-Perot interferometer. A minimum number of photodetectors were used in order to allow the high data acquisition rate needed for dynamic measurements. One photomultiplier tube (PMT) was used to measure the total Rayleigh scattering, which is proportional to the gas density. Two additional PMTs were used to detect light that passes through two apertures in a mask located in the interferometer fringe plane. An uncertainty analysis was used to select the optimum aperture parameters and to predict the measurement uncertainty due to photon shot-noise. Results of an experiment to measure the velocity of a subsonic free jet are presented.

Seasholtz, Richard G.↗

Stability boundaries for systems with frequency-model feedback and complacency filter

General parameter-plane equations were derived to generate boundaries for a class of systems characterized by a feedback loop that contains a complementary filter and a model for either the low- or high-frequency portion of the plant. This combination allows those frequencies of the part of the plant that is modeled to be fed back for control while suppressing other frequencies. For all specific examples considered, the stability regions obtained using the complementary filter and frequency model were larger (and in some cases, considerably larger) than those obtained using a low pass filter in the feedback of the system output. Furthermore, higher gain control was possible.

Barker, L. K.↗

Spectral decontamination of a real-time helicopter simulation

Nonlinear mathematical models of a rotor system, referred to as rotating blade-element models, produce steady-state, high-frequency harmonics of significant magnitude. In a discrete simulation model, certain of these harmonics may be incompatible with realistic real-time computational constraints because of their aliasing into the operational low-pass region. However, the energy is an aliased harmonic may be suppressed by increasing the computation rate of an isolated, causal nonlinearity and using an appropriate filter. This decontamination technique is applied to Sikorsky's real-time model of the Black Hawk helicopter, as supplied to NASA for handling-qualities investigations.

Mcfarland, R. E.↗

A new scheme of force reflecting control

A new scheme of force reflecting control has been developed that incorporates position-error-based force reflection and robot compliance control. The operator is provided with a kinesthetic force feedback which is proportional to the position error between the operator-commanded and the actual position of the robot arm. Robot compliance control, which increases the effective compliance of the robot, is implemented by low pass filtering the outputs of the force/torque sensor mounted on the base of robot hand and using these signals to alter the operator's position command. This position-error-based force reflection scheme combined with shared compliance control has been implemented successfully to the Advanced Teleoperation system consisting of dissimilar master-slave arms. Stability measurements have demonstrated unprecedentedly high force reflection gains of up to 2 or 3, even though the slave arm is much stiffer than operator's hand holding the force reflecting hand controller. Peg-in-hole experiments were performed with eight different operating modes to evaluate the new force-reflecting control scheme. Best task performance resulted with this new control scheme.

Kim, Won S.↗

Switching power supply filter

A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

Kumar, Prithvi R.↗

Booster cavity damper redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and is undergoing testing for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity’s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Booster Cavity Damper Redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Optimizing structured surfaces for diffractive waveguides

We introduce universal diffractive waveguide designs that can match the performance of conventional dielectric waveguides and achieve various functionalities. Optimized using deep learning, diffractive waveguides can be cascaded to form any desired length and are comprised of transmissive diffractive surfaces that permit the propagation of desired modes with low loss and high mode purity. In addition to guiding the targeted modes through cascaded diffractive units, we also developed various waveguide components and introduced bent diffractive waveguides, rotating the direction of mode propagation, as well as spatial and spectral mode filtering and mode splitting diffractive waveguide designs, and mode-specific polarization control. This framework was experimentally validated in the terahertz spectrum to selectively pass certain spatial modes while rejecting others. Without the need for material dispersion engineering diffractive waveguides can be scaled to operate at different wavelengths, including visible and infrared spectrum, covering potential applications in, e.g., telecommunications, imaging, sensing and spectroscopy.

Applied optics↗