Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hazard Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Reduction in total and major cause-specific mortality from tobacco smoking cessation: a pooled analysis of 16 population-based cohort studies in Asia

Little is known about the time course of mortality reduction following smoking cessation in Asians who have smoking behaviours distinct from their Western counterparts. We evaluated the level of reduction in all-cause, cardiovascular disease (CVD) and lung cancer mortality by years since quitting smoking, in Asia. Using Cox regression, we analysed individual participant data (n = 709 151) from 16 prospective cohorts conducted in China, Japan, Korea/Singapore, and India/Bangladesh, separately by cohorts. Cohort-specific hazard ratios (HRs) were combined using a random-effects meta-analysis. During a mean follow-up of 12.0 years, 108 287 deaths were ascertained—35 658 from CVD and 7546 from lung cancer. Among Asian men, a dose-response relationship of risk reduction in deaths from all causes, CVD and lung cancer was observed with an increase in years after smoking cessation. Compared with never smokers, however, all-cause and CVD mortality among former smokers remained elevated 10–14 years after quitting [multivariable-adjusted HR (95% confidence interval (CI) = 1.25 (1.13–1.37) and 1.20 (1.02–1.41), respectively]. Lung cancer mortality stayed almost 2-fold higher than among never smokers 15–19 years after smoking cessation [1.97 (1.41–2.73)], particularly among former heavy smokers [2.62 (1.71–4.00)]. Women who quitted for ≥5 years retained a significantly elevated mortality from all causes, CVD and lung cancer. Overall patterns of the cessation-mortality associations were similar across countries. Our findings suggest that adverse effects of tobacco smoking persist for an extended time period, even for more than two decades, which is beyond the time windows defined in current clinical guidelines for risk assessment of lung cancer and CVD.

Public, Environmental & Occupational Health↗

Radioactive Thoron 220 Rn Exhalation From Unfired Mud Building Material Into Room Air of Earthen Dwellings

Thoron ( 220 Rn), an isotope of radon with a strong α-decay energy, and its short-lived metallic progeny can pose an elevated lung cancer hazard in room air when unfired-soil derived building materials are used in earthen dwellings. Changes in moisture content and density influencing the thoron exhalation rate from earthen materials into room air were studied in the laboratory with terra rossa from a village on the Ðòng Van Karst Plateau Geopark, Viêt Nam, where ethnic minorities construct traditional dwellings with unfired terra rossa walls and floors. Our results show that the thoron exhalation rate from mud surfaces depends on (i) the content of radioactive parental nuclides in mineral components; (ii) the moisture content of mud where ~5–10 weight % water maximizes the 220 Rn exhalation rate; and (iii) the density of dry mud as primarily controlled by internal macroscopic voids, fractures, and porosity. Additional time-series of 220 Rn exhalation data from an interior mud wall of a terra rossa-built house under different seasonal and weather conditions show that the temperature is influencing thoron exhalation via the water vapor pressure deficit (VPD) in air and the associated amount of atmospheric moisture adsorbed onto indoor mud surfaces. Our data suggest that occupants of “mud house” earthen dwellings in northern Viêt Nam are exposed to an increased thoron geohazard during cooler weather, low VPD, and high relative humidity in air. Detailed studies are needed to evaluate the thoron geohazard for inhabitants of mud-built dwellings in other climates and geological terrains.

58 GEOSCIENCES↗

Review of Release Behavior of Hydrogen & Natural Gas Blends from Pipelines

Hydrogen can be used to reduce carbon emissions by blending into other gaseous energy carriers, such as natural gas. However, hydrogen blending into natural gas has important implications for safety which need to be evaluated. Hydrogen has different physical properties than natural gas, and these properties affect safety evaluations concerning a leak of the blended gas. The intent of this report is to begin to investigate the safety implications of blending hydrogen into the natural gas infrastructure with respect to a leak event from a pipeline. A literature review was conducted to identify existing data that will better inform future hazard and risk assessments for hydrogen/natural gas blends. Metrics with safety implications such as heat flux and dispersion behavior may be affected by the overall blend ratio of the mixture. Of the literature reviewed, there was no directly observed separation of the hydrogen from the natural gas or methane blend. No literature was identified that experimentally examined unconfined releases such as concentration fields or concentration at specific distances. Computational efforts have predicted concentration fields by modified versions of existing engineering models, but the validation of these models is limited by the unavailability of literature data. There are multiple literature sources that measured flame lengths and heat flux values, which are both relevant metrics to risk and hazard assessments. These data can be more directly compared to the outputs of existing engineering models for validation.

03 NATURAL GAS↗

Mil-Std-464C and Mil-Std-464D Electromagnetic Radiation Environment Evaluation

Many systems derive their electromagnetic radiation (EMR) environments from Mil-Std-464C or Mil-Std-464D, Electromagnetic Environmental Effects Requirements for Systems. This standard defines several EMR environments based on the type of system and expected application. Many nuclear weapon (NW) systems reference the ordnance environments as the starting point for their functional EMR requirements, since any item intended to go into Department of Defense (DOD) custody is expected to be certified hazards of electromagnetic radiation to ordnance (HERO) safe when exposed to the environments listed in Mil-Std-464 Table 9. This environment is defined as the envelope of all sources any system in DOD custody may ever encounter, however, and may include sources that are not relevant for a particular system. This document is intended to provide additional clarity on the Mil-Std-464C and Mil-Std-464D EMR environments, specifically the driving sources for the maximum ordnance levels. This supplementary information may be used to guide tailoring of relevant environments or application to different systems with the additional consideration of any shielding that may reduce the external environments defined in the military standard.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Association Between Baseline Hepatic or Renal Function and Clinical Outcomes for Patients With Non–Small Cell Lung Cancer Treated With a PD –1/PD– L1 Blocking Antibody Using Real–World and Trial Data

Clinical trials have demonstrated the benefit of PD-1/PD-L1 blocking antibodies for the treatment of patients with advanced non-small cell lung cancer (NSCLC) in defined patient populations that often exclude patients with moderate or severe hepatic or renal impairment. We assessed the association between overall survival (OS) and baseline organ function in patients with advanced NSCLC treated with PD-1/PD-L1 blocking antibodies in real-world data (RWD; patient-level data from electronic health records) and pooled clinical trial data submitted to the US Food and Drug Administration (FDA). The Kaplan–Meier estimator was used to estimate OS in different subgroups based on organ function. Unadjusted and adjusted Cox proportional hazards models were used to estimate the association between OS and organ function. In this hypothesis-generating study, baseline renal impairment did not appear to be associated with OS, while patients with baseline liver impairment had shorter OS. RWD provided information on a broader range of renal and hepatic function than was evaluated in clinical trials and hold promise to complement trial data in better understanding populations not represented in clinical trials.

60 APPLIED LIFE SCIENCES↗

Toxicity Values for Chemicals

The toxicity values for chemicals contained in this dataset comprise acute, subchronic, and chronic exposure durations. Cancer slope factors, inhalation unit risk, reference dose, and reference concentrations are available. These values should be used in cancer risk and noncancer hazard assessments for the calculation of preliminary remediation goals (PRGs) and hazard characterization. Users can select toxicity values from 10 combinations of exposure durations and cancer/noncancer toxicity values and select up to 1000 chemicals per query. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning with tools for benchmarking against risk-based standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Stewart, Debra [Oak Ridge National Laboratory (ORN↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

At SRS, emergency responders use a variety of tools to detect, track, and mitigate hazardous material releases into the atmosphere. Two models currently used at SRS are Puff-Plume and the Lagrangian Particle Dispersion Model (LPDM), a Gaussian and Lagrangian model, respectively. A decision has been made to replace LPDM with the more widely-supported Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model for evaluating inhalation and ingestion doses following a release. HYSPLIT is designed to compute complex dispersion and deposition simulation To achieve the implementation of HYSPLIT, we have developed a preliminary UI framework that will allow HYSPLIT to be run on ATG computers without the need for active network connections, thus avoiding the loss of capabilities in the event of a network outage during an emergency.

Earley, Ian↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY2020 Rotating Bed Reactor for Iodine Removal from WTP Melter Effluent to Support DFLAW Start-Up

In Performance Assessment (PA) of the Hanford Integrated Disposal Facility (IDF), 129 I is a significant contributor to the risk. The 2017 IDF PA accounted for 0.22% of the total 129 I inventory in Hanford tank waste as residing in the solidified liquid waste from the Effluent Treatment Facility (ETF). However, recent estimates suggest that higher percentages of the iodine processed at the Hanford Waste Treatment and Immobilization Plant (WTP) may be present in the liquid waste routed to the Liquid Effluent Retention Facility (LERF) for eventual treatment at the ETF. In addition, a recent integrated melter test performed at the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) showed the possibility that a significant fraction (>50%) of the total iodine in the melter feed could be present in the aqueous waste stream destined for the ETF. This stream represents a combination of the Effluent Management Facility (EMF) evaporator overhead condensate and the liquid waste from the WTP off-gas caustic scrubber. Higher levels of 129 I in this stream could affect the LERF and ETF Hazard Categorizations as well as the acceptability of the solidified ETF liquid secondary waste brine for disposal at the IDF. Accordingly, there is a need to investigate and develop potential methods and processes to mitigate this risk. Washington River Protection Solutions, LLC (WRPS) tasked Atkins and VSL to perform development and testing work to evaluate potential methods for removal of iodine species from the waste stream routed to the LERF. In particular, the testing investigated the use of an Atkins-SpinIonic™ Rotating Bed Reactor (RBR) system as a potential alternative to conventional column-based ion exchange or absorption processes. The present report provides results obtained from testing with an RBR system for the removal of iodine from simulants of the projected WTP waste stream that discharges to the LERF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Facility Safety Plan – Building 225

B225 is operated by the Weapons and Complex Integration (WCI) Directorate and is classified as a Low Hazard facility for radiological hazards and Light Science Industry (LSI) for chemical, radiation generating devices (RGDs) and industrial hazards. Explosives and biological hazards are not authorized for B225. B225 is located in the southwest quadrant of Lawrence Livermore National Laboratory (LLNL) less than 600 meters from the nearest site boundary. B225 is a single-story concrete tilt-up building with a steel deck roof. The primary mission of this facility is to apply nondestructive evaluation (NDE) methods to materials, components, and assemblies. B225 also contains the polymer additive manufacturing laboratories. The floor plans for B225 are provided in Appendix A.

99 GENERAL AND MISCELLANEOUS↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - September 2024 Meeting Notes

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. Commercial nuclear power plants. A collaborative U.S. and Japanese effort was initiated in 2014 by the Department of Energy Office of Nuclear Energy to identify Daiichi examination needs and evaluate recent Daiichi examination data to address these needs. This document summarizes information presented at and findings, action items, and recommendations by U.S. and Japanese experts in reactor safety and plant operations during the September 2024 Forensics Effort meeting. Significant safety insights were obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties and knowledge gaps in severe accident modeling progression, these insights continue to be used to assess whether additional updates are needed in guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional safety and economic benefits to the operating fleet and new light water reactor (LWR) and non-LWR designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

200-IA-1 Operable Unit Ecological Risk Screen

The purpose of this environmental calculation file (ECF) is to document the assumptions, inputs, methodology, equations, and results of a screening level ecological risk assessment (SLERA) conducted for eight of 12 representative waste sites within the newly formed 200 IA-1 Operable Unit (OU); the remaining four waste sites lacked soil data within the shallow vadose zone and were not further evaluated. The SLERA was conducted to evaluate ecological receptor exposure and potential risk using soil data for radionuclides and nonradionuclides occurring within the shallow vadose zone (0 to 15 ft) soil of the OU. The representative Hanford ecological receptors evaluated are: plants, soil invertebrates, California quail (Callipepla californica), Meadowlark (Sturnella neglecta), Killdeer (Charadrius vociferus), Red-tailed hawk (Buteo jamaicensis), Great Basin pocket mouse (Perognathus parvus), Deer mouse (Peromyscus maniculatus), Grasshopper mouse (Onychomys leucogaster), and badger (Taxidea taxus). During the SLERA, detected soil sample results from the shallow vadose zone were used to calculate Hazard Quotients (HQs) for nonradionuclides and Sum of Fractions (SOF) for radionuclides. The results of this SLERA support the preparation of DOE/RL-2020-51, 200-IA-1 Operable Unit Focused Feasibility Study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing Dynamic Time Warping Techniques for Discriminating Seismic Sources at Local and Regional Distances

Effective monitoring of seismic explosions and hazard assessment relies heavily on the accurate discrimination of underground seismic sources. This study investigates the application of novel nonlinear alignment techniques, specifically Dynamic Time Warping (DTW), for event-type discrimination at regional and local distances. Building on prior research that used DTW and Elastic Shape Analysis (ESA) in discrimination at regional distances, we evaluate the performance of recently developed variants of DTW, including a method that employs Pearson cross-correlation as a measure of warping distance and a time distortion coefficient that quantifies the type and degree of time distortion between signals. By analyzing observational datasets that include different source types, we assess the performance of these approaches for realistic monitoring scenarios. Specifically, we consider a dataset recorded at regional distances in the Korean Peninsula and a local-distance subset from the Unconstrained Utah Event Bulletin catalog to evaluate DTW-based discrimination across multiple distance scales. Additionally, we introduce the maximum cross-correlations of warped waveforms as a similarity metric for event classification. Through hierarchical cluster analysis and dendrogram interpretation, we present our findings, highlighting the strengths and limitations of these techniques in seismic event classification.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Computationally Selected Multivalent HIV-1 Subtype C Vaccine Protects Against Heterologous SHIV Challenge

Background: The RV144 trial in Thailand is the only HIV-1 vaccine efficacy trial to date to demonstrate any efficacy. Genetic signatures suggested that antibodies targeting the variable loop 2 (V2) of the HIV-1 envelope played an important protective role. The ALVAC prime and protein boost follow-up trial in southern Africa (HVTN702) failed to show any efficacy. One hypothesis for this is the greater diversity of subtype C viruses in southern Africa relative to CRF01_AE in Thailand. Methods: Here, we determined whether an ALVAC prime with computationally selected gp120 boost immunogens maximizing coverage of diversity of subtype C viruses in the variable V1 and V2 regions (V1V2) improved the protection of non-human primates (NHPs) from a heterologous subtype C SHIV challenge compared to more traditional regimens. Results: An ALVAC prime with Trivalent subtype C gp120 boosts resulted in statistically significant protection from repeated intrarectal SHIV challenges compared to the control. Evaluation of the immunogenicity of each vaccine regimen at the time of challenge demonstrated that different gp120 combination boosts elicited similar high magnitudes of gp120 and breadth of V1V2-binding antibodies, as well as strong Fc-mediated immune responses. Low-to-no neutralization of the challenge virus was detected. A Cox proportional hazard analysis of five pre-selected immune parameters at the time of challenge identified ADCC against the challenge envelope as a correlate of protection. Systems serology analysis revealed that immune responses elicited by the different vaccine regimens were distinct and identified further correlates of resistance to infection. Conclusions: Computationally designed vaccines with maximized subtype C V1V2 coverage mediated protection of NHPs from a heterologous Tier-2 subtype C SHIV challenge.

Immunology↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗