Search NASASearch

SEARCH · Search NASA

Results for “Heat Transfer Coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

618 records · Page 15

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Discrete Element Method

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials (3MDCP)

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Woven

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Bosch Carbon Catalyst Regeneration in Water III: Experiments for and Related to Thermal Shock

Bosch technology has the potential to close the atmospheric revitalization loop by providing theoretically 100% regeneration of metabolic carbon dioxide into oxygen. The main obstacle to using Bosch technology is over-pressurization issues in the carbon formation reactor. Prior work on Bosch catalyst regeneration established that agitating carbon coated beads in water broke up pressure causing clogs and regenerated the catalyst surface. This process proved to be time consuming with experiments taking at least one hour to regenerate ten grams of carbon coated beads. In an attempt to shorten the processing time, thermally shocking the carbon coated beads prior to mechanical agitation was tested. Agitating the carbon coated beads after exposure to a saturated steam environment was also tested to ensure that the steam generated by thermally shocking the carbon coated beads would not cause adverse effects. The rationale behind thermally shocking the carbon coated beads is that the bead would pull away from the carbon shell due to a difference in the thermal expansion coefficients. The results of this project show that the processing time can be cut in half when compared to previous work, and that saturated steam has little to no effect on regeneration.

Bosch Process

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Heat exposure and maternal stress: evidence from the GRAPHS pregnancy cohort in Ghana

Heat exposure has been linked to psychosocial stress, an established antecedent of perinatal depression; however, evidence on heat-related stress during pregnancy in sub-Saharan Africa remains limited. We analyzed psychosocial stress scores and covariate data from the Ghana Randomized Air Pollution and Health Study, linking daily maximum and minimum shaded wet bulb globe temperature (WBGT) metrics to participants’ stress scores derived from the Crisis in Family Systems-Revised Life Events Questionnaire. We evaluated associations using ordinal logistic regression of pregnancy-average and trimester-average exposures and distributed lag non-linear models (DLNMs) to assess time-varying associations across gestation. Higher average maximum WBGT exposure across pregnancy was associated with increased odds of higher psychosocial stress; each 1 °C increase in maximum WBGT was associated with 64% higher odds of belonging to a higher stress category (OR = 1.64; 95% CI = 1.17–2.31; p = 0.0040). In trimester-average models, higher first-trimester maximum WBGT was also associated with higher stress (OR = 1.44; 95% CI = 1.15–1.81; p = 0.0014). DLNMs suggested that relatively cooler daily maximum WBGT values (25th percentile) were associated with decreased odds of stress in early pregnancy, whereas extreme daily maximum WBGT values (99th percentile) showed a pattern consistent with increased odds of stress in mid-to-late gestation. These findings highlight gestational windows in which heat exposure may influence stress, emphasizing the need for further research into underlying mechanisms and effective interventions to protect maternal mental health in heat-vulnerable settings.

White, Lewis [Columbia University] (ORCID:00090005

Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37 t h AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha=0 o . In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C D , lift, C L , and longitudinal momentum, M z , obtained by numerical simulation and experimental tests are compared and show good agreement.

M Gilinsky

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha = 0 degrees. In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C (sub D), lift, C(sub L), and longitudinal momentum, M(sub z), obtained by numerical simulation and experimental tests are compared and show good agreement.

M Gilinsky

First Wall Design of a Tokamak Pilot Plant Using a Monte Carlo Model for 3-D Heat Flux Deposition

We present a method for calculating the heat fluxes deposited on nonaxisymmetric tokamak first wall components, allowing for a first-of-its-kind model for power handling in the tokamak far scrape-off layer (SOL). The DIV3D Monte Carlo model features strict global power conservation and can calculate the finite cross-field plasma transport into magnetically-shadowed regions, which is significant when dealing with meter-scale shadows introduced by components such as poloidal limiters or antennas. As a case study, we apply the DIV3D model to inform the distribution of first wall poloidal limiters in an ARC-class reactor device. We demonstrate that discrete protection limiters can efficiently reduce peak heat fluxes on recessed breeder wall components in the presence of significant far-SOL plasma fluxes. By varying the toroidal periodicity and radial standoff depth of the limiters, we demonstrate one of the tradeoffs that must be considered in first wall design: more limiters provide greater protection, but at the cost of reduced breeding performance. We also present the impact that radial misalignments between limiters would have on first wall power loading.

Monte Carlo methods

Computing the Critical Temperature of the Affine-Transformed $D=3$ Ising Model Using Masked Autoregressive Flow

The simple Ising model provides a rich environment to build and study lattice field theories. As part of an ongoing project to construct a conformal field theory (CFT) on an arbitrarily curved manifold, in this work we develop methods to measure the critical temperature $β_c$ of the affine-transformed Ising model on the face-centered cubic (FCC) lattice. The main challenge in this endeavor is finding a computationally efficient and accurate method of interpolating and extrapolating Monte Carlo observables with respect to coupling coefficients and temperature. Herein, we compare two such methods. A traditional statistical approach uses the multiple histogram (MH) method, while a newer machine learning approach uses a masked autoregressive flow (MAF) to estimate the underlying probability density function of a set of observables. While the MH method is specifically designed to interpolate and extrapolate Monte Carlo observables, we find that MAF is a viable alternative for measuring $β_c$ with a computational cost that scales more favorably. Furthermore, we comment on additional advantages of MAF relevant to our work, such as extrapolating in system volume.

Svenson, Kai [Texas U.]

Observed Land Surface Influence on Atmospheric Heat and Moisture Profiles During Interstorms

Land-atmospheric (L-A) feedbacks have historically been studied using models whose structure and parameterizations influence outcomes and insights. The representation of L-A feedbacks based on observations alone remains an ongoing challenge for understanding boundary layer development and precipitation. To address this gap, we use ground-based passive remote sensing and in-situ observations to present an analysis of the atmosphere during 103 interstorm soil moisture drydown events spanning nine warm seasons (2016–2024) in the U.S. Southern Great Plains region. By separating events based on local L-A coupling signals and characterizing the profiles of atmospheric heat and moisture to surface energy flux behavior, we investigate the physical mechanisms linking land surface processes to boundary layer development. We find that during interstorm drydowns, the atmospheric column follows a consistent pattern: moisture increases within the boundary layer, peaks near its top, and declines rapidly above, while warming occurs through the depth. Drydowns that shift toward evaporation produce stronger and deeper thermodynamic responses than cases dominated by sensible heating, which are weaker and shallower. Additionally, moisture is accumulated faster within the boundary layer during shorter drydowns, with longer drydowns representing slower, moisture-limited growth. Drydowns with wetter initial soil moisture will sustain stronger moistening within and above the boundary layer, accelerating buoyancy growth and convective potential toward the next storm. These results provide observational evidence linking surface flux evolution to boundary layer thermodynamics and offer a process-level benchmark for evaluating coupled L-A representations in models and demonstrating the influence of soil moisture on short-term weather forecasting skill.

Zhang, M. S. [Massachusetts Inst. of Technology (M

Structure–Property Linkage in Alloys Using Graph Neural Network and Explainable Artificial Intelligence

Deep learning tools have recently shown significant potential for accelerating the prediction of microstructure–property linkage in materials. While deep neural networks like convolution neural networks (CNNs) can extract physics information from 3D microstructure images, they often require a large network architecture and substantial training time. In this research, we trained a graph neural network (GNN) using phase field generated microstructures of Ni-Al alloys to predict the evolution of mechanical properties. We found that a single GNN is capable of accurately predicting the strengthening of Ni-Al alloys with microstructures of varying sizes and dimensions, which cannot otherwise be done with a CNN. Additionally, GNN requires significantly less GPU utilization than CNN and offers more interpretable explanation of predictions using saliency analysis as features are manually defined in the graph. We also utilize explainable artificial intelligence tool Bayesian Inference to determine the coefficients in the power law equation that governs coarsening of precipitates. Overall, our work demonstrates the ability of the GNN to accurately and efficiently extract relevant information from material microstructures without having restrictions on microstructure size or dimension and offers an interpretable explanation.

Chemistry

Ground Slope Effects on Lander Radiator Performance

Two sensitivity studies were performed to examine the drop in radiator heat rejection from slopes. Study #1 used a 5.5m tall reduced order asset to represent a small-lander/rover. Study #2 used a 20m asset represent a tall lander. The assets had body mounted horizontal, 45º inward-tilted, and vertical radiator orientations. The impact of slopes on different radiator orientations and on radiators pointing different directions (i.e., slope verses sun) was investigated. The studies were conducted at a polar location of -82.5ºS to capture the incident solar flux at the northmost, and therefore the hottest, range of potential Artemis landing sites (Mons Mouton Plateau).

Lunar Slope

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD