Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Impacts of Sub‐Grid Topographic Representations on Surface Energy Balance and Boundary Conditions in the E3SM Land Model: A Case Study in Sierra Nevada

Abstract Sub‐grid topographic heterogeneity has large impacts on surface energy balance and land‐atmosphere interactions. However, the impacts of representing sub‐grid topographic effects in land surface models (LSMs) on surface energy balance and boundary conditions remain unclear. This study analyzed and evaluated the impacts of sub‐grid topographic representations on surface energy balance, turbulent heat flux, and scalar (co‐)variances in the Energy Exascale Earth System Model (E3SM) land model (ELM). Three sub‐grid topographic representations in ELM were compared: (a) the default sub‐grid structure (D), (b) the recently developed sub‐grid topographic structure (T), and (c) high spatial resolution (1KM). Additionally, two different solar radiation schemes in ELM were compared: (a) the default plane‐parallel radiative transfer scheme (PP) and (b) the parameterization scheme (TOP) that accounts for sub‐grid topographic effects on solar radiation. A series of offline simulations with the three grid discretization structures (D, T, and 1KM) and two schemes of solar radiation (TOP and PP) were carried out using the Sierra Nevada, California. 1KM simulations with TOP well capture the spatial heterogeneity of surface fluxes compared to Moderate Resolution Imaging Spectroradiometer remote sensing data. There are significant differences between TOP and PP in the 1‐km simulated surface energy balance, but the differences in mean values and standard deviations become small when aggregated to the grid scale (i.e., 0.5°). The T configuration better mimics the 1KM simulations with TOP than the D configuration and better captures the sub‐grid topographic effects on surface energy balance and boundary conditions. These results underline the importance of representing sub‐grid topographic heterogeneities in LSMs and motivate future research to understand the sub‐grid topographic effects on land‐atmosphere interactions over mountainous areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Fourier-like Thermal Relaxation of Nanoscale Explosive Hot Spots

Hot spots are local regions of high temperature that are widely considered to govern explosive initiation. Hot spot dynamics rests on a delicate balance between heat generation due to chemical reactions and heat loss through thermal conduction, making accurate determinations of the conductivity under extreme conditions a key component of predictive explosive models. We develop here an approach to directly determine the thermal transport properties of explosive hot spots with realistic initial structures through a combination of molecular dynamics (MD) and diffusive heat equation (HEq) modeling. Effective thermal conductivity values are determined by fitting HEq models to MD predictions of long timescale hot spot relaxation. The approach is applied to model hot spots in the molecular crystalline explosive 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) for a range of shock strengths and two limiting cases for impact orientation. Isotropic and anisotropic HEq models yield similar results, despite TATB exhibiting some of the largest and most anisotropic thermal conductivity values for explosive near normal conditions. The conductivity is found to be a strong function of density, which parametrically captures dependence on temperature, pressure, and material state. The associated root-mean-square errors of the fitted HEq models are approximately 5% of MD predicted final equilibrium temperatures. Here, the conductivity values determined here for TATB hot spots are considerably larger than those used in a prior hot spot criticality study, which may significantly impact predictions for critical hot spot sizes. The approach provides a convenient foundation for determining the effective thermal conductivity for hot spot problems in other explosives and directly yields information on reasonable approximations that might be taken in higher-level models for those materials.

36 MATERIALS SCIENCE↗

Improved core-edge compatibility using impurity seeding in the small angle slot (SAS) divertor at DIII-D

Impurity seeding studies in the slot divertor (SAS) at DIII-D have revealed a strong relationship between the detachment onset and pedestal characteristics with both target geometry and impurity species. N 2 seeding in the slot has led to the first simultaneous observation of detachment on the entire suite of boundary diagnostics viewing the SAS without degradation of core confinement. SOLPS-ITER simulations with D+C+N, full cross-field drifts and n-n collisions activated are performed for the first time in DIII-D to interpret the behavior. This illustrates a strong effect of divertor configuration and plasma drifts on the recycling source distribution with significant consequences on plasma flows. Flow reversal is found for both main ions and impurities affecting strongly the impurity transport and providing an explanation for the observed dependence on strike point location of the detachment onset and impurity leakage found in the experiments. Matched discharges with either nitrogen or neon injection show that while nitrogen does not significantly affect the pedestal, neon leads to increased pedestal pressure gradient and improved pedestal stability. Little nitrogen penetrates in the core, but a great amount of neon is found in the pedestal consistent with the different ionization potentials of the two impurities. This research demonstrates that neutral and impurity distributions in the divertor can be controlled through variations in strike point locations in a fixed baffle structure. Divertor geometry combined with impurity seeding enables mitigated divertor heat flux balancing core contamination and thus leading to enhanced divertor dissipation and improved core-edge compatibility which are essential for ITER and for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-temperature effects in Hall-MHD simulations of the HIT-SI experiment

A two-temperature Hall-magnetohydrodynamic (Hall-MHD) model, which evolves the electron and ion temperatures separately, is implemented in the PSI-Tet 3D MHD code and used to model plasma dynamics in the Helicity Injected Torus–Steady Inductive (HIT-SI) experiment. The two-temperature model is utilized for HIT-SI simulations in both the PSI-Tet and NIMROD codes at a number of different injector frequencies in the 14.5–68.5 kHz range. At all frequencies, the NIMROD two-temperature model results in increased toroidal current, lower chord-averaged density, higher average temperatures, outward radial shift of the current centroid, and axial symmetrization of the current centroid, relative to the single-temperature NIMROD simulations. The two-temperature PSI-Tet model illustrates similar trends, but at high frequency operation, it exhibits lower electron temperature, smaller toroidal current, and decreased axial symmetrization with respect to the single-temperature PSI-Tet model. With all models, average temperatures and toroidal currents increase with the injector frequency. Power balance and heat fluxes to the wall are calculated for the two-temperature PSI-Tet model and illustrate considerable viscous and compressive heating, particularly at high injector frequency. Parameter scans are also presented for artificial diffusivity, wall temperature, and density. Both artificial diffusivity and the density boundary condition significantly modify the plasma density profiles, leading to larger average temperatures, toroidal current, and relative density fluctuations at low densities. As a result, a low density simulation achieves sufficiently high current gain (G > 5) to generate significant volumes of closed flux lasting 1–2 injector periods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Localized mix-induced radiative cooling in a capsule implosion at the National Ignition Facility

In this work, w present direct measurements of electron temperature variations within an inertially confined deuterium-tritium plasma caused by localized mix of higher-Z materials into the central hot spot. The data are derived from newly developed differentially filtered penumbral imaging of the bremsstrahlung continuum emission. Our analysis reveals distinct localized emitting features in the stagnated hot-spot plasma, and we infer spatial variations in the electron temperature: the mixed region is 660±130eV colder than the surrounding hot-spot plasma at 3.26±0.11keV. Our analysis of the energy flow shows that we measure approximately steady-state conditions where the radiative losses in the mix region are balanced by heat conduction from the surrounding hot deuterium-tritium plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

Engineering Design of a Linde-BASF Advanced Post-Combustion CO 2 Capture Technology at a Linde Steam Methane Reforming H 2 Plant

Linde carried out an initial engineering design study for a Linde-BASF advanced post combustion CO 2 capture technology to be installed at a commercial-scale steam methane reforming (SMR) hydrogen plant located in the US Gulf Coast. This pre-FEED equivalent study included following: (1) basic design, including specific project scope definition and design basis, (2) basic engineering, including development of process flow diagrams and heat & material balances, (3) inside the battery limit (ISBL) equipment and systems specification, (4) balance of plant outside the battery limit (OSBL) equipment and systems specifications, (5) technology maturation plan, (6) hazard and operability (HAZOP) review, (7) environmental, health and safety (EH&S) assessment and environmental permitting analysis, (8) constructability review, (9) ISBL and OSBL EPC cost estimation, and (10) commercial-scale techno-economic analysis including capital expenditures (CAPEX) and operating expenditures (OPEX) and CO 2 capture cost estimates.

08 HYDROGEN↗

Mariner-9 based simulation of radiative convective temperature changes in the Martian dust-laden atmosphere-soil system

A numerical simulation of radiative, conductive, and convective heat transfer of the Martian dust-laden atmosphere-soil system is presented with particular emphasis given to heating/cooling in regions of sharp variation in temperature or absorption and its resultant impact on outgoing planetary spectral radiance, as measured by the Mariner 9 IRIS. Thermal coupling between the ground and atmospheric subsystems is modeled by the total heat flux balance at the interface. In the simulation procedure, local thermodynamic equilibrium (LTE) is assumed, and a combined strong-weak line transmission function permits short- and long-range exchanges of energy from the surface toward space. Direct absorption of insolation in the near-IR bands by both silicate dust and CO2 is incorporated.

Dannevik, W. P.↗

Internal thermotopography and shifts in general thermal balance in man under special heat transfer conditions

Thermal regulation for astronauts working in pressure suits in open space provides for protection by a system of artificial heat removal and compensation to counteract possible changes in the heat regulating function of the human body that occur under the complex effects of space flight conditions. Most important of these factors are prolonged weightlessness, prolonged limitation of motor activity, and possible deviations of microclimatic environmental parameters.

Gorodinskiy, S. M.↗

Ice growth in Duluth harbor and western Lake Superior

Ice growth computation for the Duluth-Superior harbor and the adjacent Lake Superior waters, using the heat budget balance, agrees well with the measured ice values for the 1972-73 winter season. ERTS data is used for the determination of ice albedo and the resulting ice decay rate on Lake Superior. During the period of ice packing near Duluth, the calculated ice decay rates, combined with the ERTS data on the extent and the condition of the ice field indicate maximum ice packing between March 20-27, when the packed ice field, exhibiting albedo values above 70% reached an average 60 cm thickness. The results offer a method for description of ice packing which could be used for ice forecasting on Lake Superior if more frequent ERTS images were available.

Sydor, M.↗

The evaporation of spherical clouds in a hot gas. II - Effects of radiation

The effects of radiation on the evaporation of spherical clouds in a hot medium are considered. The critical cloud radius at which radiative losses balance conductive heating is determined as a function of the external temperature and density. Smaller clouds evaporate, and larger clouds condense. The conditions under which the surfaces of the clouds may be detected are discussed. Net radiative losses for evaporating clouds are calculated, and an effective cooling function for a cloudy medium is obtained. The results may be applied to clouds in supernova remnants, in the interstellar medium, and in clusters of galaxies.

Mckee, C. F.↗

Tropical sea surface temperature - An interactive one-dimensional atmosphere-ocean model

It is shown that the (cumulus) convective processes in the tropics may be described by a one-dimensional cloud model, while the near-surface ocean may similarly be described by a one-dimensional mixed-layer model. The coupling is achieved through a sea surface flux budget combined with the flux parameterizations implied by Monin-Obukhov similarity theory. The coupled one-dimensional atmosphere-ocean model is applied to the equilibrium situation in which all temperatures reach a steady state. For the ocean, the fluxes must vanish in equilibrium, but the atmosphere maintains a stable lapse rate by balancing cumulonimbus heating against net radiative cooling. All water precipitating from cumulonimbus clouds must have evaporated from the sea. It is shown that this equilibrium system is closed and determinable solely in terms of the solar constant.

Sarachik, E. S.↗