Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating Augmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Space shuttle heat pipe thermal control systems

Heat pipe (HP) thermal control systems designed for possible space shuttle applications were built and tested under this program. They are: (1) a HP augmented cold rail, (2) a HP/phase change material (PCM) modular heat sink and (3) a HP radiating panel for compartment temperature control. The HP augmented cold rail is similar to a standard two-passage fluid cold rail except that it contains an integral, centrally located HP throughout its length. The central HP core helps to increase the local power density capability by spreading concentrated heat inputs over the entire rail. The HP/PCM modular heat sink system consists of a diode HP connected in series to a standard HP that has a PCM canister attached to its mid-section. It is designed to connect a heat source to a structural heat sink during normal operation, and to automatically decouple from it and sink to the PCM whenever structural temperatures are too high. The HP radiating panel is designed to conductively couple the panel feeder HPs directly to a fluid line that serves as a source of waste heat. It is a simple strap-on type of system that requires no internal or external line modifications to distribute the heat to a large radiating area.

Alario, J.↗

A parametric study of thermally augmented O2/H2 rocket enines

An analysis is presented of the performance of a conceptual propulsion system in which liquid hydrogen and liquid oxygen are first vaporized and heated by thermal power from a spacecraft nuclear electric power supply prior to combustion in a rocket engine. Calculations of the specific impulse (I-sp) are presented for a series of O2/H2 oxidizer-to-fuel mixture ratios and reactant pre-heat temperatures (T-aug). It is found that the ratio of the augmentation power to the total engine jet power (P-aug/P-tot) determines the engine thrust for a given P-aug, T-aug, and I-sp. In addition, the performance of an unaugmented O2/H2 and a heated-hydrogen rocket engine were also calculated for the same conditions. Results show that an augmented O2/H2 engine has three to eight times the thrust of a heated H2 engine for a given P-aug. It is concluded that it should be possible to design a high/low thrust propulsion system using a common propellant, with the option of using thermal power from the nuclear electric power supply to augment the low-thrust propulsion system during cruise periods when the reactor's full electric power is not needed.

Frisbee, R. H.↗

Fuel design concept to stabilize boiling water reactors

A new BWR design concept is introduced where the standard fuel rod array is augmented with thin metallic fuel elements. The heat transfer characteristics of the thin elements mimic the effect of direct energy deposition and introduces a strong stabilizing effect on density wave oscillations. The metallic fuel elements can be introduced to existing fuel bundle designs where some rods are replaced or part-length fuel rods are augmented with the metallic elements. New fuel rod arrays can be envisioned, and one example is given, to suit the concept of the hybrid oxide-metal concept. Although metal fuels are not commonly utilized in the commercial fleet, they are common in naval applications, which makes the proposed hybrid uniquely suited for the disposition of plutonium.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Multiphase computational fluid dynamics modeling of reacting flows in absorption columns for carbon capture

First-principles derived computational fluid dynamics (CFD) simulations have been proposed as a fundamental tool for investigating solvent-based CO 2 absorption in packed columns due to their ability to accurately represent the underlying nonlinear, multiscale dynamics. Numerous studies have previously utilized such CFD simulations to investigate hydrodynamics of columns with structured and random packings by assessing the key hydrodynamic metrics such as the interfacial and wetted areas. While mapping such metrics for different conditions is essential to the optimization of absorption columns, it is not sufficient, as the CO 2 capture rate depends also on the coupled, nonlinear dynamics from the underlying chemical reaction kinetics, thermodynamics, and heat-transfer rates. In this work, we present detailed CFD simulation results augmented by incorporating the effects of interfacial physical mass transfer of CO 2 , heat release from chemical reaction kinetics, and thermophysical property variations from resulting temperature gradients. We demonstrate the applicability of the proposed approach in numerically assessing the performance of packed columns by evaluating key hydrodynamic quantities, CO 2 absorption rates, and temperature rise in a reference column with packings that are structurally similar to the Sulzer Mellapak™ 250.Y packing, for different solvent inflow velocities and temperatures. Predictions from simulation results are found to be consistent with the trends in experimental observations from the literature, suggesting that the predictive capabilities of the simulation framework can be leveraged to guide the future development of absorber-column designs and optimized process flowsheets.

Absorption columns↗

Computational Discovery of Intermolecular Singlet Fission Materials Using Many-Body Perturbation Theory

Intermolecular singlet fission (SF) is the conversion of a photogenerated singlet exciton into two triplet excitons residing on different molecules. SF has the potential to enhance the conversion efficiency of solar cells by harvesting two charge carriers from one high-energy photon, whose surplus energy would otherwise be lost to heat. The development of commercial SF-augmented modules is hindered by the limited selection of molecular crystals that exhibit intermolecular SF in the solid state. Computational exploration may accelerate the discovery of new SF materials. The GW approximation and Bethe–Salpeter equation (GW+BSE) within the framework of many-body perturbation theory is the current state-of-the-art method for calculating the excited-state properties of molecular crystals with periodic boundary conditions. In this Review, we discuss the usage of GW+BSE to assess candidate SF materials as well as its combination with low-cost physical or machine learned models in materials discovery workflows. We demonstrate three successful strategies for the discovery of new SF materials: (i) functionalization of known materials to tune their properties, (ii) finding potential polymorphs with improved crystal packing, and (iii) exploring new classes of materials. In addition, three new candidate SF materials are proposed here, which have not been published previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Study of Antisite Defects in Hydrothermally Prepared LiFePO4 by in Situ X-ray Diffraction

Hydrothermal synthesis has proven to be a cost-effective, energy-efficient approach for the manufacture of lithium iron phosphate (LiFePO{sub 4}) and its related materials. However, hydrothermally prepared LiFePO{sub 4} typically suffers from antisite defects, where some of the iron resides on lithium sites and restricts lithium-ion mobility. A post-heat-treatment temperature of around 700 C is generally used to eliminate cation disorder, but little is known about these antisite defects or their concentration as a function of the post-heat-treatment temperature. In this study, time-resolved, synchrotron X-ray diffraction reveals that antisite defects are completely eliminated above 500 C, suggesting that the electrochemical performance may be significantly enhanced by a milder postsynthesis heat treatment. The preliminary electrochemical results show a significant enhancement in the electrochemical capacity with the defect-free material, with the specific capacity increasing by approximately 60% at a C/20 rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermal balance of a wall with PCM-enhanced thermal insulation

ABSTRACT: PCM insulation mixtures function as lightweight thermal mass components. It is expected that these types of dynamic insulation systems will contribute to the objective of reducing energy use in buildings. In this paper, dynamic thermal properties of a material in which phase hange occurs are analyzed, using the temperature-dependent specific heat model. Integral formula for the total heat flow in finite time interval, across the surface of a slab of the phase change material, was derived. Simulations have been performed to analyze heat transfer through a light-weight wall assembly with PCM-enhanced insulation, in different external climate thermal conditions. Results of simulations indicate that for cyclic processes, the effect of PCM in an insulation layer results rather in time shifting of the heat flux extreme values than in reduction of the total heat flow. The heat gains maxima, resulting in high cooling loads, are shifted in time by about two hours and reduced about 15% to 30% for not very high external sol-air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Coupled model for liquid lithium plasma facing components

Numerical analysis provides the design choice and operating window of liquid metal Plasma Facing Components (PFC) concepts. Coupled analysis of boundary plasma together with the surrounding boundary structures is required. Here, to achieve this goal, PPPL is developing a comprehensive multi-physics model for modeling of PFCs in fusion devices. The model includes the fluid-kinetic code SOLPS-ITER and the flow and heat transfer code CFX from ANSYS. SOLPS-ITER was augmented with a liquid metal boundary condition algorithm, allowing direct two-way coupling of the plasma analysis with the two-dimensional analytical slab flow model which includes heat convection in the liquid metal PFC. The target heat flux resulting from this coupled analysis is used as a boundary condition for detailed 3D Computational Fluid Dynamics (CFD) Magneto Hydro Dynamics (MHD) and heat transfer analysis. A new formulation of MHD equations is introduced in the numerical procedure ensuring current conservation of the discretized equations. Results of the 3D analysis are used for final validation of the coupled model. A PFC design where a porous wall is used to stabilize the liquid metal surface, while MHD drive is used to push the liquid metal flow inside the PFC, will be investigated in the regimes where vapor shielding is created for enhanced volumetric plasma heat dissipation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat transfer during condensation of HFC-134a and R-404A inside of a horizontal smooth and micro-fin tube

In recent small and medium capacity refrigeration systems, the condenser tubes are provided with micro-fins from inside. The vapour refrigerant at the compressor outlet and the condenser inlet is in superheat state. As it advances in the condenser it is in two phases and at the outlet it is in sub cooled liquid. The heat transfer coefficient (HTC) during condensation of HFC-134a and R-404A in a smooth (8.56 mm ID) and micro-fin tubes (8.96 mm ID) are experimentally investigated. Different from previous studies, the present experiments are performed for various condensing temperatures, with superheating and sub cooling and using hermetically sealed compressor. The test runs are done at average saturated condensing temperatures ranging from 35 C to 60 C. The mass fluxes are between 90 and 800 kg m{sup -2} s{sup -1}. The experimental results indicate that the average HTC increases with mass flux but decreases with increasing condensing temperature for both smooth and micro-fin tubes. The average condensation HTCs of HFC-134a and R-404A for the micro-fin tubes were 1.5-2.5 and 1.3-2 times larger than that in smooth tube respectively. The HTCs for R-404A are less than that of HFC-134a. New correlations based on the data gathered during the experimentation for predicting condensation HTCs are proposed for wide range of operating conditions. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dish stirling solar receiver combustor test program

The operational and energy transfer characteristics of the Dish Stirling Solar Receiver (DSSR) combustor/heat exchanger system was evaluated. The DSSR is designed to operate with fossil fuel augmentation utilizing a swirl combustor and cross flow heat exchanger consisting of a single row of 4 closely spaced tubes that are curved into a conical shape. The performance of the combustor/heat exchanger system without a Stirling engine was studied over a range of operating conditions and output levels using water as the working fluid. Results show that the combustor may be started under cold conditions, controlled safety, and operated at a constant air/fuel ratio (10 percent excess air) over the required range of firing rates. Furthermore, nondimensional heat transfer coefficients based on total heat transfer are plotted versus Reynolds number and compared with literature data taken for single rows of closely spaced tubes perpendicular to cross flow. The data show enhanced heat transfer for the present geometry and test conditions. Analysis of the results shows that the present system meets specified thermal requirements, thus verifying the feasibility of the DSSR combustor design for final prototype fabrication.

Bankston, C. P.↗

A Laboratory Model of a Hydrogen/Oxygen Engine for Combustion and Nozzle Studies

A small laboratory diagnostic thruster was developed to augment present low thrust chemical rocket optical and heat flux diagnostics at the NASA Lewis Research Center. The objective of this work was to evaluate approaches for the use of temperature and pressure sensors for the investigation of low thrust rocket flow fields. The nominal engine thrust was 110 N. Tests were performed at chamber pressures of about 255 kPa, 370 kPa, and 500 kPa with oxidizer to fuel mixture ratios between 4.0 and 8.0. Two gaseous hydrogen/gaseous oxygen injector designs were tested with 60 percent and 75 percent fuel film cooling. The thruster and instrumentation designs were proven to be effective via hot fire testing. The thruster diagnostics provided inner wall temperature and static pressure measurements which were compared to the thruster global performance data. For several operating conditions, the performance data exhibited unexpected trends which were correlated with changes in the axial wall temperature distribution. Azimuthal temperature distributions were found to be a function of operating conditions and hardware configuration. The static pressure profiles showed that no severe pressure gradients were present in the rocket. The results indicated that small differences in injector design can result in dramatically different thruster performance and wall temperature behavior, but that these injector effects may be overshadowed by operating at a high fuel film cooling rate.

Morren, Sybil Huang↗

Mechanisms Regulating Deep Moist Convection and Sea-Surface Temperatures of the Tropics

Despite numerous previous studies, two relationships between deep convection and the sea-surface temperature (SST) of the tropics remain unclear. The first is the cause for the sudden emergence of deep convection at about 28 deg SST, and the second is its proximity to the highest observed SST of about 30 C. Our analysis provides a rational explanation for both by utilizing the Improved Meteorological (IMET) buoy data together with radar rainfall retrievals and atmospheric soundings provided by the Tropical Ocean Global Atmosphere Coupled Ocean-Atmosphere Response Experiment (TOGA-COARE). The explanation relies on the basic principles of moist convection as enunciated in the Arakawa-Schubert cumulus parameterization. Our analysis shows that an SST range of 28-29 C is necessary for "charging" the atmospheric boundary layer with sufficient moist static energy that can enable the towering convection to reach up to the 200 hPa level. In the IMET buoy data, the changes in surface energy fluxes associated with different rainfall amounts show that the deep convection not only reduces the solar flux into the ocean with a thick cloud cover, but it also generates downdrafts which bring significantly cooler and drier air into the boundary-layer thereby augmenting oceanic cooling by increased sensible and latent heat fluxes. In this way, the ocean seasaws between a net energy absorber for non-raining and a net energy supplier for deep-convective raining conditions. These processes produce a thermostat-like control of the SST. The data also shows that convection over the warm pool is modulated by dynamical influences of large-scale circulation embodying tropical easterly waves (with a 5-day period) and MJOs (with 40-day period); however, the quasi-permanent feature of the vertical profile of moist static energy, which is primarily maintained by the large-scale circulation and thermodynamical forcings, is vital for both the 28 C SST for deep convection and its upper limit at about 30 C.

Sud, Y. C.↗