Investigation of potential driver modules and transmission lines for a high frequency power system on the space station
The objective was to assess the feasibility of using the Series Resonant inverter as the driver module for the high frequency power system on the Space Station. This study evaluates the performance of the Series Resonant driver when it was operated with a dc input voltage and run through a series of tests to determine its start-up performance, response to load changes, load regulation, and efficiency. Also, this study compares the Series Resonant driver to another kind of driver that uses a Power Transistor snubber. An investigation of the various types of transmission lines is initiated. In particular, a simplified approach is utilized to describe the optimal transmission line.