Development of television tubes for the large space telescope.

Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. This paper discusses the performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope II for direct high resolution imagery is also discussed. The paper also discusses the Large Space Telescope image sensor requirements and the development of a larger television tube for this mission.

Lowrance, J. L.↗

Dual-Energy X-Radiography With Gadolinium Filter

Image resolution increased, and cost reduced. Proposed dual-energy x-ray imaging system, continuous bremsstrahlung spectrum from x-ray tube filtered by foil of nonradioactive gadolinium or another rare-earth metal to form two-peaked energy spectrum. After passing through patient or object under examination, filtered radiation detected by array of energy-discriminating, photon-counting detectors. Detector outputs processed to form x-ray image for each peak and possibly enhanced image based on data taken at both peaks.

Rutt, Brian↗

Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

Source record↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Honeywell's Compact, Wide-angle Uv-visible Imaging Sensor

Honeywell is currently developing the Earth Reference Attitude Determination System (ERADS). ERADS determines attitude by imaging the entire Earth's limb and a ring of the adjacent star field in the 2800-3000 A band of the ultraviolet. This is achieved through the use of a highly nonconventional optical system, an intensifier tube, and a mega-element CCD array. The optics image a 30 degree region in the center of the field, and an outer region typically from 128 to 148 degrees, which can be adjusted up to 180 degrees. Because of the design employed, the illumination at the outer edge of the field is only some 15 percent below that at the center, in contrast to the drastic rolloffs encountered in conventional wide-angle sensors. The outer diameter of the sensor is only 3 in; the volume and weight of the entire system, including processor, are 1000 cc and 6 kg, respectively.

Pledger, D.↗

Imaging Magnetometer

Imaging magnetometer proposed for scientific, industrial, or military use in detecting underground structures containing magnetic materials and underground machines generating and/or altering magnetic fields. Includes electron-beam tube integrated with phosphor-coated charge-coupled device (CCD). Images formed by magnetic deflection of electron beam. Locations, magnitudes, and directions of identifiable features of magnetic field examined to extract data on locations, sizes, and types of magnetically detected objects.

Moynihan, Philip I.↗

Flame Structure Comparison using Jet-A and an isoparaffinic fuel in a lean direct injection flame tube combustor

This paper offers a first look at some recently acquired optical data. The effect of reference velocity on flame thickness, fuel atomization, and relative speciation of OH, CH, C2, and soot for two National Jet Fuel Combustion Program (NJFCP) fuels are explored in this paper. The NJFCP fuels are an average Jet-A, designated A-2 with a derived cetane number (DCN) of 49, and an isoparaffinic kerosene, C-4. C-4 fuel is made up primarily of C9 - C13, and C16 isoparaffins and is a combination of 60% Sasol IPK and 40% GEVO alcohol-to-jet (ATJ). C-4 has a DCN of 28. Both fuels begin distillation at about the same temperature, but C-4 completes about 30 degrees Celsius lower than A-2. Chemiluminescence images were acquired in a 5-atm gas turbine flame tube combustor using the NASA 7-point lean direct injector (LDI). The flame characteristics were determined through imaging with three scientific cameras. OH*, CH*, and C2* chemiluminescence were collected through narrow bandpass filters centered at 313nm, 430nm and 515nm onto an intensified high-speed camera framed at 8-kHz. A second high-speed camera collected color flame images at rates between 40 and 50 kHz. An ICCD camera framed at 20 Hz was used to record planar laser scatter from liquid fuel. Differences in speciation for the chemiluminescent species was observed between the two fuels. Some reasons for the differences are explored in this paper.

gas turbine combustion↗

Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

Humphreys, William M., Jr.↗

Cathodochromic cathode ray tube: An operations manual

A cathodochromic (CC) storage and display system capable of storing full TV resolution images has been built. The images are derived from standard TV signals: composite video, composite sync, composite blanking, horizontal drive, and vertical drive. Image storage takes place in the CC CRT; the fixed image is written for several TV frames for the contrast to be usable. Once stored on the CC CRT, the image can be read out in one of three modes: with the eye, a 35-mm camera, or a TV camera. Incoming information may also be stored in a storage tube similar to the CC CRT but with a phosphor layer behind the CC layer. By exciting the phosphor layer with a standard raster scan it is possible to read out an image stored in the CC layer in one of three modes: direct viewing, photography, or flying-spot readout using a photomultiplier.

Heyman, P. M.↗

SFOF development

Investigating video image display assembly and discernibility of cathode ray tube gray shades for SFOF development

Source record↗

High Resolution Studies of Sunspots and Flux Tubes

This contract started as a three-year research study of sunspots and magnetic flux tubes in the solar atmosphere, using tunable filter images collected with a CCD camera during observing runs at the Canary Islands observatories in Spain. Scientific results are reported at conferences and published in the appropriate journals. The contract is being performed by the Solar and Astrophysics Laboratory (S&AL), part of the Lockheed Palo Alto Advanced Technology Center (ATC) of Lockheed Martin Missiles and Space (LMMS). The principal investigator is Dr. Alan Title, and the research is done by him and other scientific staff at S&AL, often in collaboration with visiting scientists and students from other institutions. An extension to the contract has been awarded for developing the Solar Lite technology demonstration telescope, a 1-meter solar telescope with silicon carbide optics made at the Vavilov Optical Institute in St. Petersburg, Russia. The highlights during this reporting period included the continuation of the fabrication efforts on the Solar Lite optical components at Vavilov State Optical Institute, including the completion of the Gregorian telescope field stop. A visit was made to the Vavilov Institute to review the progress and inspect the optical components.

Source record↗

Time-Averaged Velocity, Temperature and Density Surveys of Supersonic Free Jets

A spectrally resolved molecular Rayleigh scattering technique was used to simultaneously measure axial component of velocity U, static temperature T, and density p in unheated free jets at Mach numbers M = 0.6,0.95, 1.4 and 1.8. The latter two conditions were achieved using contoured convergent-divergent nozzles. A narrow line-width continuous wave laser was passed through the jet plumes and molecular scattered light from a small region on the beam was collected and analyzed using a Fabry-Perot interferometer. The optical spectrum analysis air density at the probe volume was determined by monitoring the intensity variation of the scattered light using photo-multiplier tubes. The Fabry-Perot interferometer was operated in the imaging mode, whereby the fringe formed at the image plane was captured by a cooled CCD camera. Special attention was given to remove dust particles from the plume and to provide adequate vibration isolation to the optical components. The velocity profiles from various operating conditions were compared with that measured by a Pitot tube. An excellent comparison within 5m's demonstrated the maturity of the technique. Temperature was measured least accurately, within 10K, while density was measured within 1% uncertainty. The survey data consisted of centerline variations and radial profiles of time-averaged U, T and p. The static temperature and density values were used to determine static pressure variations inside the jet. The data provided a comparative study of jet growth rates with increasing Mach number. The current work is part of a data-base development project for Computational Fluid Dynamics and Aeroacoustics codes that endeavor to predict noise characteristics of high speed jets. A limited amount of far field noise spectra from the same jets are also presented. Finally, a direct experimental validation was obtained for the Crocco-Busemann equation which is commonly used to predict temperature and density profiles from known velocity profiles. Data presented in this paper are available in ASCII format upon request.

Panda, Jayanta↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗

An experimental study of the Richtmyer-Meshkov instability in microgravity

Richtmyer-Meshkov (RM) instability occurs when a planar interface separating two fluids of different density is impulsively accelerated in the direction of its normal. It is one of the most fundamental fluid instabilities and is of importance to the fields of astrophysics and inertial confinement fusion. Because RM instability experiments are normally carried out in shock tubes, where the generation of a sharp, well-controlled interface between gases is difficult, there is a scarcity of good experimental results. The experiments presented here use a novel technique that circumvents many of the experimental difficulties that have previously limited the study of RM instability in shock tubes. In these experiments, the instability is generated incompressibly, by bouncing a rectangular tank containing two liquids off of a fixed spring. These experiments, which utilize PLIF flow visualization, yield time-motion image sequences of the nonlinear development and transition to turbulence of the instability that are of a quality unattainable in shock tube experiments. Measurements obtained from these images, therefore, provide benchmark data for the evaluation of nonlinear models for the late-time growth of the instability. Because the run time in these experiments is limited, new experiments in the NASA Glenn 2.2 second drop tower, capable of achieving longer run times, are currently under way.

Rheology/methods↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Photon counting image sensor development for astronomical applications

Specially built intensified CCD (ICCD) detector tubes were purchased and the performance of the electron bombardment process was investigated. In addition to studying the signal characteristics of the photoevents, there was interest in demonstrating that back-illuminated chips were not susceptible to radiation damage to their clocking electrodes. How to perform a centroid analysis for a 2-dimensional Gaussian distribution of charge is described. Measurement of the projection (along columns or rows) of the average charge spread profile is discussed. The development and flight of the Interstellar Medium Absorption Profile Spectrograph (IMAPS) is discussed.

Jenkins, Edward B.↗

Vortex Rings Generated by a Shrouded Hartmann-Sprenger Tube

The pulsed flow emitted from a shrouded Hartmann-Sprenger tube was sampled with high-frequency pressure transducers and with laser particle imaging velocimetry, and found to consist of a train of vortices. Thrust and mass flow were also monitored using a thrust plate and orifice, respectively. The tube and shroud lengths were altered to give four different operating frequencies. From the data, the radius, velocity, and circulation of the vortex rings was obtained. Each frequency corresponded to a different length to diameter ratio of the pulse of air leaving the driver shroud. Two of the frequencies had length to diameter ratios below the formation number, and two above. The formation number is the value of length to diameter ratio below which the pulse converts to a vortex ring only, and above which the pulse becomes a vortex ring plus a trailing jet. A modified version of the slug model of vortex ring formation was used to compare the observations with calculated values. Because the flow exit area is an annulus, vorticity is shed at both the inner and outer edge of the jet. This results in a reduced circulation compared with the value calculated from slug theory accounting only for the outer edge. If the value of circulation obtained from laser particle imaging velocimetry is used in the slug model calculation of vortex ring velocity, the agreement is quite good. The vortex ring radius, which does not depend on the circulation, agrees well with predictions from the slug model.