Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPACT PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Hydrogen Effects on Cladding Performance during Simulated Loss of Coolant Accident Testing

Fresh Zircaloy cladding segments were charged with hydrogen and subjected to simulated Loss of Coolant Accident (LOCA) conditions to assess the impact of hydrogen on the cladding mechanical performance and rupture resistance. The cladding rupture temperature decreased by 10 °C for every 100 wppm H added into the system for two different internal pressurization cases. Post-test analysis showed a loss of ductility with increasing hydrogen content, evident through decreased balloon sizes, smaller rupture openings, and sharper rupture interfaces. Digital image correlation was used to map the cladding strain in situ for two cladding segments. An elevated intermediate temperature uniform strain was visible for the hydride cladding, occurring prior to the decreased ductility during balloon and rupture determined from posttest fractography and microscopy. The thermal stability of Zr alloys as a function of hydrogen concentration and the thermal stability of Zr hydride as a function of temperature are likely responsible for the uniform deformation behavior at intermediate temperatures. The present framework for rapid assessment of hydrogen effects on cladding rupture can be utilized as an initial comparison to high burnup cladding thermomechanical response to a LOCA, where local regions may contain high concentrations of precipitated Zr hydride phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Kinetic Consequences of Water on Catalytic Methane Pyrolysis

Hydrogen production from biomass and natural gas has emerged as a prominent research area in response to the growing demand for energy from alternative sources that minimize CO 2 emissions. In this study, we investigate the impact of water, which is present in and generated from biomass-derived streams, on carbon nanotube (CNT) growth and hydrogen production during methane decomposition using Ni–Mo/MgO as a catalyst. We reveal here that the role of water on CNT growth is highly complex; its effect depends on the stage of growth at which the water is incorporated. When water is introduced at the beginning of methane decomposition ( t = 0 h), methane conversion rates are negatively impacted. We hypothesize that water inhibits the significant phase changes the Ni–Mo/MgO catalyst undergoes during catalyst carburization. In contrast, the incorporation of a small percentage of water after a stabilization period ( t = 3 h) results in methane conversion rate enhancements that scale with the introduced water partial pressure as water selectively reacts with amorphous carbon deposits that lead to catalyst deactivation, thus prolonging the lifetime of some of the most active sites. Moreover, water incorporation after stabilization significantly reduces the apparent activation energy. Density Functional Theory (DFT) calculations reveal that water preferentially interacts with carbon fragments on the catalyst surface to remove carbon deposits with a barrier lower than that required for methane activation, further supporting its role in cleaning active sites on the catalyst surface. Characterization of the resulting carbon nanotubes reveals the formation of more graphitic materials produced in the presence of water, highlighting the impact of water on nanotube properties. These results provide clarity toward the many ways in which water, or cofeeding of biomass-derived materials, may impact catalytic methane pyrolysis rates.

carbon nanotubes↗

Quantifying the impact of the Si/O interface in CCSN explosions using the Force Explosion Condition

ABSTRACT The explosion mechanism of a core-collapse supernova (SN) is a complex interplay between neutrino heating and cooling (including the effects of neutrino-driven convection), the gravitational potential, and the ram pressure of the infalling material. To analyse the post-bounce phase of an SN, one can use the generalized force explosion condition (FEC+), which succinctly formalizes the interplay among these four phenomena in an analytical condition, consistent with realistic simulations. In this paper, we use the FEC+ to study the post-bounce phase of 341 spherically symmetric simulations, where convection is included through a time-dependent mixing-length approach. We find that the accretion of the Si/O interface through the expanding shock can significantly change the outcome of the SN by driving the FEC+ above the explosion threshold. We systematically explore this by (i) artificially smoothing the pre-SN density profile, and (ii) artificially varying the mixing length. In both cases, we find that large-enough density contrasts at the Si/O interface lead to successful shock revival only if the FEC+ is already close to the explosion threshold. Furthermore, we find that the accretion of the Si/O interface has a substantial effect on the critical condition for SN explosions, contributing between 5 and 15 per cent, depending on how pronounced the density contrast at the interface is. Earlier studies showed that convection affects the critical condition by 25–30 per cent, which demonstrates that the accretion of the Si/O interface through the shock can play a nearly comparable role in influencing shock dynamics.

Boccioli, Luca (ORCID:000000024819310X)↗

Reaction Pathways and Energy Consumption in NH 3 Decomposition for H 2 Production by Low Temperature, Atmospheric Pressure Plasma

Pathways for NH 3 decomposition to N 2 and N 2 H 4 by atmospheric pressure nonthermal plasma are analyzed using a combination of molecular beam mass spectrometry measurements and zero-dimensional kinetic modeling. Experimental measurements show that NH 3 conversion and selectivity towards N 2 formation scale monotonically with the specific energy input into the plasma with ~ 100% selectivity to N 2 formation achieved at specific energy inputs above 0.12 J cm −3 (3.1 eV (molecule NH 3 ) −1 ). The kinetic model recovers these trends, although it underpredicts N 2 selectivity at low specific energy input. These discrepancies can be explained by the underestimation of reaction rate coefficients for reactions that consume N 2 H x species in collisions with H radicals and/or radial nonuniformities in power deposition, gas temperature, and species concentrations that are not represented by the plug flow approximation used in the model. The kinetic model shows that N 2 formation proceeds through N 2 H x decomposition pathways rather than NH x decomposition pathways in low temperature, atmospheric pressure plasma. Higher selectivity toward N 2 production can be achieved by operating at higher NH 3 conversion and with a higher gas temperature. Furthermore, the high energy cost of NH 3 decomposition by atmospheric pressure nonthermal plasma found in this work (25–50 eV (molecule NH 3 converted) −1 ; 17–33 eV (molecule H 2 formed) −1 ) is a result of the energy requirement for electron-impact dissociation of NH 3 and the significant re-formation of NH 3 by three-body recombination reactions between NH 2 and H.

Nonthermal plasma↗

A quantitative risk assessment framework for fault reactivation in underground hydrogen storage: Coupled simulation and deep learning approach

Underground hydrogen storage (UHS) is emerging as a critical solution for large-scale energy storage. However, like all subsurface fluid injection activities, UHS poses the risk of injection-induced fault reactivation. Accurate risk assessment is essential to ensuring the safety and efficiency of UHS operations. This study presents the development of deep-learning surrogate models for fault reactivation prediction in UHS, trained on a comprehensive database of fully coupled fluid flow-geomechanics simulations. Our findings reveal that analytical models often yield unreliable estimates, with errors up to 54% in the allowable injection pressure, potentially leading to a 40% reduction in UHS operational capacity. The developed surrogate models were incorporated into a quantitative risk assessment (QRA) framework, enabling probabilistic evaluation of fault reactivation risk while accounting for uncertainties in the input variables. Site-specific features, such as horizontal stress gradients, fault’s dip and strike angles, and operational parameters like bottom-hole injection pressure and well-fault distance, were identified as the primary drivers of fault reactivation across various stress regimes. Whereas other hydraulic, geological, and poroelastic reservoir properties were found to have a secondary impact. Notably, we observed that the risk of fault reactivation for a critically oriented fault with a static friction coefficient greater than 0.55 remains below 10% in a normal faulting stress regime. However, the risk significantly increases as the stress regime transitions from normal to strike-slip and ultimately to reverse faulting conditions. These findings underscore the importance of rigorous site characterization and comprehensive QRA evaluations to optimize UHS performance and minimize geomechanical risks.

25 ENERGY STORAGE↗

Formation of late-generation atmospheric compounds inhibited by rapid deposition

Reactive organic carbon species are important fuel for atmospheric chemical reactions, including the formation of secondary organic aerosol. However, in parallel to atmospheric oxidation processes, deposition can remove compounds from the atmosphere and impact downstream environments. To understand the impact of deposition on atmospheric oxidation, we present a framework for predicting and visualizing the fate of a molecule on the basis of the physicochemical properties of compounds (Henry’s law constant, vapour pressure and reaction rate constants), which are used to estimate timescales for oxidation and deposition. Further, by implementing our deposition rates in chemical models, we show that deposition substantially suppresses atmospheric reactivity and aerosol formation by removing early-generation products and preventing the formation of large fractions (up to 90%) of downstream, late-generation compounds. Deposition is frequently missing in the laboratory experiments and detailed chemical modelling, which probably biases our understanding of atmospheric composition.

54 ENVIRONMENTAL SCIENCES↗

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma treating water for nitrate based nitrogen fertilizer - A review of recent device designs

Atmospheric pressure air plasma treatment of water is a promising alternative to the industrially intensive Haber-Bosch process for the production of nitrogen fertilizer. Nitrogen fertilizer is vital for plant life, and the environmental impacts of modern fertilizer application cannot be neglected. In order to maintain or increase food production in the future, more sustainable alternatives must be investigated. Plasma can be easily operated at smaller scales, onsite, utilizing green energy sources, cutting down transportation costs and impacts. This article focuses on nitrogen fixation by plasma treating water for use as nitrogen fertilizer. Here, we highlight recent advances (within the last two years) regarding water treating plasma devices, the challenges still facing the field, and recommend more thorough collaborative investigations be carried out in order to focus on the design and optimization of these devices for the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Assessing the impact of alpha particles on thermal confinement in JET D-T plasmas through global GENE-Tango simulations

The capability of the global, electromagnetic gyrokinetic GENE code interfaced with the transport Tango solver is exploited to address the impact of fusion alpha particles (in their dual role of fast particles and heating source) on plasma profiles and performance at JET in the discharges with the highest quasi-stationary peak fusion power during the DTE2 experimental campaigns. Employing radially global nonlinear electromagnetic GENE-Tango simulations, we compare results with/without alpha particles and alpha heating. Our findings reveal that alpha particles have a negligible impact on turbulent transport, with GENE-Tango converging to similar plasma profiles regardless of their inclusion as a kinetic species in GENE. On the other hand, alpha heating is found to contribute to the peaking of the electron temperature profiles, leading to a 1 keV drop on the on-axis electron temperature when alpha heating is neglected in Tango. The minimal impact of alpha particles on turbulent transport in this JET discharge–despite this being the shot with the highest fusion output–is attributed to the low content of fusion alpha in this discharge. To assess the potential impact of alpha particles on turbulent transport in regimes with higher alpha particle density, as expected in ITER and fusion reactors, we artificially increased the alpha particle concentration to levels expected for ITER. By performing global nonlinear GENE standalone simulations, we found that increasing the alpha particle density beyond five times the nominal value lead to significant overall turbulence destabilization. These results demonstrate that an increased alpha particle concentration can significantly impact transport properties under simulated JET experimental conditions. However, these findings cannot be directly extrapolated to ITER due to the substantial differences in parameters such as plasma size, magnetic field, plasma current, and thermal pressure.

energetic particles↗

Investigation of fuel film formation and soot emissions in a GDI engine during cold-start with Split-injection strategies

This study investigates the impact of fuel-film formation on engine-out soot emissions in a gasoline direct injection (GDI) engine under cold-start conditions. Split-injection strategies were applied by varying the number of injections, injection duration, and total fuel quantity to affect wall wetting and control the average in-cylinder equivalence ratio. A combined experimental and numerical approach was employed to analyze fuel-film deposition, combustion efficiency, and engine-out soot and unburnt hydrocarbons (UHC) emissions. In particular, fuel film distribution estimated by means of non-reacting, 3-D, computational fluid dynamics (CFD) simulations, together with experimentally measured soot data, were used to investigate fuel film formation and its role in soot generation. In the experiments, a skip-fired engine control strategy was applied to mimic the transient nature of engine cold-start operation. The results indicate that, under the same total number of injections, increasing the average in-cylinder equivalence ratio through longer injection durations improves combustion stability, as indicated by the decrease of the coefficient of variation of IMEP n (Net Indicated Mean Effective Pressure) from 6.0 % to 0.6 %. However, this strategy leads to higher soot emissions, which increased by nearly an order of magnitude, primarily due to enhanced wall-film formation. In contrast, increasing the number of injections while maintaining a constant equivalence ratio significantly impacts fuel-film deposition and, consequently, soot emissions, with a fivefold reduction of the measured engine-out soot, decreasing from 3.5 mg to 0.7 mg. A soot-film correlation was developed and achieved a high coefficient of determination (r 2 = 0.95) and was further extended to account for spark timing effects. These findings confirm the effectiveness of split-injection for avoiding wall film formation and soot emissions, and the critical role of fuel film in soot generation, supporting the hypothesis that pool fires play a crucial role in contributing to soot formation under these cold-start conditions. In conclusion, the study also indicates the value of a predictive soot-film correlation for developing cold-start emission control strategies.

Engine Cold-start↗

Suppressed Cosmic-Ray Energy Densities in Molecular Clouds from Streaming Instability-regulated Transport

Abstract Cosmic rays (CRs) are the primary driver of ionization in star-forming molecular clouds (MCs). Despite their potential impacts on gas dynamics and chemistry, no simulations of star cluster formation following the creation of individual stars have included explicit cosmic-ray transport (CRT) to date. We conduct the first numerical simulations following the collapse of a 2000 M ⊙ MC and the subsequent star formation including CRT using the STAR FORmation in Gaseous Environments framework implemented in the GIZMO code. We show that when CRT is streaming-dominated, the CR energy in the cloud is strongly attenuated due to energy losses from the streaming instability. Consequently, in a Milky Way–like environment the median CR ionization rate in the cloud is low ( ζ ≲ 2 × 10 −19 s −1 ) during the main star-forming epoch of the calculation and the impact of CRs on the star formation in the cloud is limited. However, in high-CR environments, the CR distribution in the cloud is elevated ( ζ ≲ 6 × 10 −18 ), and the relatively higher CR pressure outside the cloud causes slightly earlier cloud collapse and increases the star formation efficiency by 50% to ∼13%. The initial mass function is similar in all cases except with possible variations in a high-CR environment. Further studies are needed to explain the range of ionization rates observed in MCs and explore star formation in extreme CR environments.

Astronomy & Astrophysics↗

On the importance of species immiscibility in mixing-layer dynamics at supercritical pressures

The mixing dynamics of injected propellants is a key factor in determining the ignition performance and combustion-instability response of rocket engines, internal combustion engines, and gas turbines. A key source of uncertainty in the prediction of phase-exchange dynamics is the immiscibility of the injected propellants at supercritical pressure conditions, which induces liquid/vapor phase separation and surface-tension dynamics. While experimental observations indicate the presence of liquid/vapor interfacial structures, this interfacial dynamics is typically neglected in numerical analyses. To address this issue, the objective of the present study is to systematically evaluate the importance of species immiscibility on the phase-exchange dynamics of cryogenic LOX/GH2 mixing layers at typical rocket engine injection conditions. This is accomplished by comparing simulations of (i) a recently developed interface-capturing Regularized-Interface Method (RIM) formulation, and (ii) the commonly employed Diffuse-Interface Method (DIM) formulation. Analysis shows that the interfacial dynamics significantly impact the atomization and mixing of the propellants in the near-injector region, which is not captured by the DIM formulation. The findings of this study extend to other immiscible injection systems, such as LOX/kerosene and hydrocarbon-fuel/air, thereby highlighting the importance of resolving species immiscibility in simulating high-pressure combustion engines.

diffused-interface method↗

Integrated geological, economic, and risk assessment of underground hydrogen storage

Underground hydrogen storage (UHS) is a promising option to buffer variable renewable power and support the hydrogen economy. Yet this technology is early-stage, and key uncertainties remain about how coupled processes such as geochemical and geomechanical impacts affect long-term storage security. In this paper, we seek to integrate the results from a large, multi-scale research program to quantify core feasibility metrics and situate these studies within ongoing efforts. Through this work, we evaluate hydrogen recoverability during storage by assessing diffusive losses, losses to geochemical interactions and their subsequent impact on geomechanical properties, and losses to residual saturation during injection and withdrawal. Molecular and laboratory studies show that lithologic heterogeneity, pore geometry, and mineral surface chemistry govern hydrogen–rock interactions, controlling loss pathways. High-pressure coreflooding is used to estimate relative permeabilities and measure parameters needed for reservoir-scale sensitivity analyses. These core-scale experiments found early hydrogen breakthrough at low saturations driven by capillary and viscous fingering, which limits pore-space utilization at early times, while repeated injection and withdrawal cycles improve deliverability over time. Technoeconomic factors and purity requirements for end uses are also considered as part of our comprehensive feasibility analysis. Finally, we underscore the importance of geophysical monitoring and tailored injection strategies to maintain integrity and efficiency. Together, these results provide a quantitative foundation for safe, scalable deployment of UHS and highlight priorities for future integrated studies.

08 HYDROGEN↗

Discrepant wear behavior of carbon nanotubes (CNTs) and dispersant in four-ball unidirectional and ball-on-flat reciprocating sliding tests

Carbon nanotubes (CNTs), basically rolled graphene sheets, have been studied lately as oil additives in the literature. However, we observed discrepant impact of CNTs on wear protection from two common tribological tests, four-ball unidirectional sliding and high frequency reciprocating rig (HFRR) ball-on-flat reciprocating sliding. To gain a stable suspension and dispersion of the CNTs in the oil, the CNT surface was functionalized with a phenyl ligand and a dispersant, polyisobutylene succinimide (PIBSI), was added. In the four-ball test, PIBSI alone failed to protect the surface but the CNTs effectively reduced the wear loss. The observations in the HFRR test however were the opposite: the PIBSI alone provided strong wear reduction but the CNTs had no positive impact. Here, such a discrepancy was hypothetically attributed to the different wear protection mechanisms by the PIBSI and CNTs which responded distinctively under different testing conditions. Additional unidirectional and reciprocating sliding tests with matching Hertzian contact pressures were able to validate the hypothesis. Worn surface morphological examination and tribofilm chemical analysis further supported the proposed wear mechanisms. Fundamental understanding gained in this study provides insights into the potential benefits and limitations of using CNTs in lubrication.

36 MATERIALS SCIENCE↗

Continuum shock mixture models for Ni+Al multilayers: Inert mesoscale simulations

Mesoscale modeling of shock waves in Ni+Al multilayers poses significant challenges that are due, in part, to shock-induced chemical reactions. Current modeling approaches utilize reactive molecular dynamics (MD), but they are limited to resolving domains of only a few hundred nanometers. In contrast, actual multilayer superlattices can be tens of micrometers thick, and they exhibit non-ideal (i.e., wavy) interfaces. The second part of our research builds upon previous work developing physically based, thermodynamically complete equations of state for various Ni and Al intermetallic compositions. Here, we introduce a novel workflow for high-fidelity mesoscale simulations of Ni+Al multilayers using a continuum hydrocode. By increasing the simulation domain size beyond MD limitations (e.g., 2 × 6 μm 2 ) and incorporating explicit interfacial roughness, we investigate the shock response of Ni+Al multilayers at previously unexplored scales. Our experimental design encompasses nine multilayer geometries with varying roughness amplitudes and tilt angles (θ = 15°, 30°, and 45°), alongside 19 flyer impact velocities ranging from 0.3 to 3.0 km/s, resulting in a total of 171 high-fidelity simulations. The bulk shock state from inert 2D mesoscale simulations aligns with the law of mixtures, while temperature and pressure fluctuations strongly correlate with multilayer geometry types. A new metric dubbed the “hot spot probability integral” shows a greater dependence on a tilt angle than interfacial roughness.

Kittell, David E. [Sandia National Laboratories (S↗

Modeling optical systematics for the Taurus CMB experiment

We simulate a variety of optical systematics for Taurus, a balloon-borne cosmic microwave background (CMB) polarisation experiment, to assess their impact on large-scale E-mode polarisation measurements and constraints of the optical depth to reionisation τ. We model a one-month flight of Taurus from Wanaka, New Zealand aboard a super-pressure balloon (SPB). We simulate night-time scans of both the CMB and dust foregrounds in the 150 GHz band, one of Taurus's four observing bands. We consider a variety of possible systematics that may affect Taurus's observations, including non-gaussian beams, pointing reconstruction error, and half-wave plate (HWP) non-idealities. For each of these, we evaluate the residual power in the difference between maps simulated with and without the systematic, and compare this to the expected signal level corresponding to Taurus's science goals. Our results indicate that most of the HWP-related systematics can be mitigated to be smaller than sample variance by calibrating with Planck's TT spectrum and using an achromatic HWP model, with a preference for five layers of sapphire to ensure good systematic control. However, additional beam characterization will be required to mitigate far-sidelobe pickup from dust on larger scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗