Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Compliant Intramedullary Stems for Joint Reconstruction

The longevity of current joint replacements is limited by aseptic loosening, which is the primary cause of non-infectious failure for hip, knee, and ankle arthroplasty. Aseptic loosening is typically caused either by osteolysis from particulate wear, or by high shear stresses at the bone-implant interface from over-constraint. Our objective was to demonstrate feasibility of a compliant intramedullary stem that eliminates over-constraint without generating particulate wear. The compliant stem is built around a compliant mechanism that permits rotation about a single axis. We first established several models to understand the relationship between mechanism geometry and implant performance under a given angular displacement and compressive load. We then used a neural network to identify a design space of geometries that would support an expected 100-year fatigue life inside the body. We additively manufactured one representative mechanism for each of three anatomic locations, and evaluated these prototypes on a KR-210 robot. The neural network predicts maximum stress and torsional stiffness with 2.69% and 4.08% error respectively, relative to finite element analysis data. We identified feasible design spaces for all three of the anatomic locations. Simulated peak stresses for the three stem prototypes were below the fatigue limit. Benchtop performance of all three prototypes was within design specifications. Our results demonstrate the feasibility of designing patient- and joint-specific compliant stems that address the root causes of aseptic loosening. Guided by these results, we expect the use of compliant intramedullary stems in joint reconstruction technology to increase implant lifetime.

60 APPLIED LIFE SCIENCES↗

Osteogenic preconditioning in perfusion bioreactors improves vascularization and bone formation by human bone marrow aspirates

Cell-derived extracellular matrix (ECM) provides a niche to promote osteogenic differentiation, cell adhesion, survival, and trophic factor secretion. To determine whether osteogenic preconditioning would improve the bone-forming potential of unfractionated bone marrow aspirate (BMA), we perfused cells on ECM-coated scaffolds to generate naïve and preconditioned constructs, respectively. The composition of cells selected from BMA was distinct on each scaffold. Naïve constructs exhibited robust proangiogenic potential in vitro, while preconditioned scaffolds contained more mesenchymal stem/stromal cells (MSCs) and endothelial cells (ECs) and exhibited an osteogenic phenotype. Upon implantation into an orthotopic calvarial defect, BMA-derived ECs were present in vessels in preconditioned implants, resulting in robust perfusion and greater vessel density over the first 14 days compared to naïve implants. After 10 weeks, human ECs and differentiated MSCs were detected in de novo tissues derived from naïve and preconditioned scaffolds. These results demonstrate that bioreactor-based preconditioning augments the bone-forming potential of BMA.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Single Photon Sources in GaN

The recent discovery of bright, room-temperature, single photon emitters in GaN leads to an appealing alternative to diamond best single photon emitters given the widespread use and technological maturity of III-nitrides for optoelectronics (e.g. blue LEDs, lasers) and high-speed, high-power electronics. This discovery opens the door to on-chip and on-demand single photon sources integrated with detectors and electronics. Currently, little is known about the underlying defect structure nor is there a sense of how such an emitter might be controllably created. A detailed understanding of the origin of the SPEs in GaN and a path to deterministically introduce them is required. In this project, we develop new experimental capabilities to then investigate single photon emission from GaN nanowires and both GAN and AlN wafers. We ion implant our wafers with the ion implanted with our focused ion beam nanoimplantation capabilities at Sandia, to go beyond typical broad beam implantation and create single photon emitting defects with nanometer precision. We've created light emitting sources using Li + and He + , but single photon emission has yet to be demonstrated. In parallel, we calculate the energy levels of defects and transition metal substitutions in GaN to gain a better understanding of the sources of single photon emission in GaN and AlN. The combined experimental and theoretical capabilities developed throughout this project will enable further investigation into the origins of single photon emission from defects in GaN, AlN, and other wide bandgap semiconductors.

36 MATERIALS SCIENCE↗

Waveguides for neurostimulation in the cochlea

Introduction Optical stimulation has been suggested for neural stimulation to improve cochlear implants. Light allows for more spatially selective activation of neuron populations than electrical current, offering more independent frequency bands along the spiral ganglion. These bands are available to encode acoustic information with anticipated better frequency resolution, improving cochlear implant user performance in noisy listening environments, tonal languages, and music perception. Methods Optical cochlear implants (oCIs) can deliver light either directly via small emitters within the cochlea or via waveguides from external optical sources. We investigated three waveguide designs made from OrmoComp ® , a polymer that cures through ultraviolet (UV) radiation. Waveguides were fabricated via injection molding and coated using dip-coating or thermal reflow, or through aspiration of OrmoComp ® into polyimide tubing that served as the cladding of the waveguide. The choice of fabrication technique directly determined the waveguides' total diameter: thermal reflow yielded ≈940 μm, dip-coating produced ≈306 μm, and aspiration resulted in ≈132 μm core diameter waveguides. Given the human cochlea's small size, we focused on analyzing the 306-μm and 132-μm waveguides, evaluating their optical performance (propagation and bending losses) and mechanical properties (bending stiffness and insertion forces). Furthermore, we evaluated some of these designs in in-vivo guinea pigs experiments. Results For the 100-μm core diameter waveguides, the propagation losses were 12.34 ± 1.26, 1.18 ± 0.88, 1.49 ± 0.58, and 3.43 ± 0.68 dB/cm at 534, 1,375, 1,460, and 1,550 nm, respectively. The respective bending losses at a 2 mm radius of curvature were 5.50 ± 1.32, 0.56 ± 0.26, 0.79 ± 0.18, and 0.64 ± 0.23 dB, and at 1 mm 8.54 ± 1.30, 2.05 ± 0.84, 2.11 ± 0.50, and 1.44 ± 0.37 dB. The bending stiffness of a 1 mm segment of the 100-μm-diameter waveguides was 18.9 ± 2.2 N/m. Insertion forces for the 100-μm-diameter waveguides into an acrylic human-size scala tympani model were < 25 mN. For the waveguides with 306 and 940 μm total diameter, the propagation losses ranged between 0.43 and 2.40 dB/cm at 534, 680, 1,375, and 1,550 nm, between 2.19 and 3.78 dB/cm at 450 and 1,460 nm. Bending losses for 360 degrees at 1,375 nm were 5.0, 2.4, and 0.46 for a bending radius of 2.5-, 3-, and 4-mm. Discussion Our study demonstrated that the polymer OrmoComp ® is suitable for fabricating waveguides to transmit near-infrared radiation. In-vivo experiments showed optically evoked auditory responses originating from optical stimulation in the guinea pigs' first cochlear turn while radiation was delivered. Incoming experiments will focus on evaluating long-term performance of these waveguides in guinea pigs and cats. This study will be designed to provide insights into the waveguides' performance and biocompatibility over extended periods, essential for their potential clinical application in future oCIs.

Kim, Matthew↗

Melt-Pool Dynamics and Microstructure of Mg Alloy WE43 under Laser Powder Bed Fusion Additive Manufacturing Conditions

Magnesium-based alloy WE43 is a state-of-the-art bioresorbable metallic implant material. There is a need for implants with both complex geometries to match the mechanical properties of bone and refined microstructure for controlled resorption. Additive manufacturing (AM) using laser powder bed fusion (LPBF) presents a viable fabrication method for implant applications, as it offers near-net-shape geometrical control, allows for geometry customization based on an individual patient, and fast cooling rates to achieve a refined microstructure. In this study, the laser–alloy interaction is investigated over a range of LPBF-relevant processing conditions to reveal melt-pool dynamics, pore formation, and the microstructure of laser-melted WE43. In situ X-ray imaging reveals distinct laser-induced vapor depression morphology regimes, with minimal pore formation at laser-scan speeds greater than 500 mm/s. Optical and electron microscopy of cross-sectioned laser tracks reveal three distinct microstructural regimes that can be controlled by adjusting laser-scan parameters: columnar, dendritic, and banded microstructures. These regimes are consistent with those predicted by the analytic solidification theory for conduction-mode welding, but not for keyhole-mode tracks. The results provide insight into the fundamental laser–material interactions of the WE43 alloy under AM-processing conditions and are critical for the successful implementation of LPBF-produced WE43 parts in biomedical applications.

36 MATERIALS SCIENCE↗

Neural interface methods and apparatus to provide artificial sensory capabilities to a subject

Embodiments of neural interfaces according to the present invention comprise sensor modules for sensing environmental attributes beyond the natural sensory capability of a subject, and communicating the attributes wirelessly to an external (ex-vivo) portable module attached to the subject. The ex-vivo module encodes and communicates the attributes via a transcutaneous inductively coupled link to an internal (in-vivo) module implanted within the subject. The in-vivo module converts the attribute information into electrical neural stimuli that are delivered to a peripheral nerve bundle within the subject, via an implanted electrode. Methods and apparatus according to the invention incorporate implantable batteries to power the in-vivo module allowing for transcutaneous bidirectional communication of low voltage (e.g. on the order of 5 volts) encoded signals as stimuli commands and neural responses, in a robust, low-error rate, communication channel with minimal effects to the subjects' skin.

Buerger, Stephen P.↗

Wireless optofluidic systems for programmable in vivo pharmacology and optogenetics

Provided are implantable, injectable and/or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate, one or more microfluidic channels embedded in or supported by the substrate and a fluid actuator in operational communication with one or more reservoirs and responsive to a wireless control signal. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In some embodiments, the devices are self-powered and fully implantable. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

Rogers, John A.↗

Spatially Enhanced Electrostatic Doping in Graphene Realized via Heterointerfacial Precipitated Metals

Forming heavily-doped regions in 2D materials, like graphene, is a steppingstone to the design of emergent devices and heterostructures. Here, a selective-area approach is presented to tune the work-function and carrier density in monolayer graphene by spatially synthesizing sub-monolayer gallium beneath the 2D-solid. The localized metallic gallium is formed via precipitation from an underlying diamond-like carbon (DLC) film that is spatially implanted with gallium-ions. By controlling the interfacial precipitation process with annealing temperature, spatially precise ambipolar tuning of the graphene work-function is achieved, and the tunning effect preserved upon cooling to ambient conditions. Consequently, charge carrier densities from ≈1.8 × 10 10 cm -2 (hole-doped) to ≈7 × 10 13 cm -2 (electron-doped) are realized, confirmed by in situ and ex situ measurements. The theoretical studies corroborated the role of gallium at the heterointerface on charge transfer and electrostatic doping of the graphene overlayer. Specifically, sub-monolayer gallium facilitates heavy n-doping in graphene. Extending this doping strategy to other implantable elements in DLC provides a new means of exploring the physics and chemistry of highly-doped 2D materials.

36 MATERIALS SCIENCE↗

Emergent Magnetism with Continuous Control in the Ultrahigh-Conductivity Layered Oxide PdCoO 2

The current challenge to realizing continuously tunable magnetism lies in our inability to systematically change properties, such as valence, spin, and orbital degrees of freedom, as well as crystallographic geometry. Here, we demonstrate that ferromagnetism can be externally turned on with the application of low-energy helium implantation and can be subsequently erased and returned to the pristine state via annealing. We find that this high level of continuous control is made possible by targeting magnetic metastability in the ultrahigh-conductivity, nonmagnetic layered oxide PdCoO 2 where local lattice distortions generated by helium implantation induce the emergence of a net moment on the surrounding transition metal octahedral sites. These highly localized moments communicate through the itinerant metal states, which trigger the onset of percolated long-range ferromagnetism. The ability to continuously tune competing interactions enables tailoring precise magnetic and magnetotransport responses in an ultrahigh-conductivity film and will be critical to applications across spintronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non-dilute helium-related defect interactions in the near-surface region of plasma-exposed tungsten

We report a systematic energetic analysis of helium-related defect interactions that mediate helium (He) segregation on surfaces of plasma-exposed tungsten at different levels of He ion implantation. We focus on high He fluences that increase the He content in the plasma-exposed material well beyond the dilute limit of He concentration and employ atomic configurations generated by large-scale molecular dynamics simulations of He-implanted tungsten. We perform systematic molecular statics computations of cluster– defect interaction energetics in the highly defect-rich near-surface region of plasma-exposed tungsten for small mobile helium clusters as a function of the cluster distance from the surface. In this region, mobile clusters are also subjected to the stress fields generated by defects such as helium bubbles and other clusters, which govern cluster–defect interactions in addition to the cluster–surface interaction. Based on systematic investigation of individual cluster–defect interactions, we develop a mathematical framework to describe the interaction energy landscapes consisting of elastic interaction potential perturbations to finite-width square-well potentials, where the potential well accounts for cluster trapping by the defect at close range and subsequent coalescence and the perturbation potential is parameterized according to elastic inclusion theory. Superposition of all the relevant interaction potentials provides a comprehensive description of the interaction energy landscape that would be experienced by a small mobile cluster along its migration path toward the plasma-exposed surface at high He fluence. Such descriptions are particularly important for developing atomistically-informed, hierarchical multi-scale models of helium cluster dynamics in plasma-facing materials.

36 MATERIALS SCIENCE↗

Identification and characterization of deep nitrogen acceptors in β-Ga 2 O 3 using defect spectroscopies

The ability to achieve highly resistive beta-phase gallium oxide (β-Ga 2 O 3 ) layers and substrates is critical for β-Ga 2 O 3 high voltage and RF devices. To date, the most common approach involves doping with iron (Fe), which generates a moderately deep acceptor-like defect state located at E C -0.8 eV in the β-Ga 2 O 3 bandgap. Recently, there has been growing interest in alternative acceptors, such as magnesium (Mg) and nitrogen (N), due to their predicted deeper energy levels, which could avoid inadvertent charge modulation during device operation. In this work, a systematic study that makes direct correlations between the introduction of N using ion implantation and the observation of a newly observed deep level at E C -2.9 eV detected by deep-level optical spectroscopy (DLOS) is presented. The concentration of this state displayed a monotonic dependence with N concentration over a range of implant conditions, as confirmed by secondary ion mass spectrometry (SIMS). With a near 1:1 match in absolute N and E C -2.9 eV trap concentrations from SIMS and DLOS, respectively, which also matched the measured removal of free electrons from capacitance-voltage studies, this indicates that N contributes a very efficiently incorporated compensating defect. Density functional theory calculations confirm the assignment of this state to be an N (0/-1) acceptor with a configuration of N occupying the oxygen site III [N O(III) ]. The near ideal efficiency for this state to compensate free electrons and its location toward the midgap region of the β-Ga 2 O 3 bandgap demonstrates the potential of N doping as a promising approach for producing semi-insulating β-Ga 2 O 3 .

36 MATERIALS SCIENCE↗

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Comparative study of helium bubbles in a Ti-Ta alloy and a Ti/Ta nanocomposite

Here, we investigated the size, density, and distribution of helium (He) bubbles in a Ti-Ta single-phase alloy and a Ti/Ta dual-phase nanocomposite using transmission electron microscopy. The Ti/Ta nanocomposite was fabricated via phase separation during high-temperature annealing of the single-phase Ti-Ta alloy. He ion implantation in the Ti-Ta single-phase alloy leads to the formation of nano-scale He bubbles (~1.7 nm in size, ~2.6×10 5 /μm 3 in volumetric density). He bubbles were found to segregate to grain boundaries. Under identical implantation conditions, numerous He bubbles also formed in the Ti/Ta nanocomposite. Closer inspection revealed that He bubbles in the Ti-rich phase are smaller and of higher volumetric density (~1.2 nm, ~8.4×10 5 /μm 3 ) than those in the Tarich phase (~3 nm, ~1.8×10 5 /μm 3 ) and the single-phase alloy. He bubbles were also observed to decorate phase boundaries, but they were generally smaller than those on grain boundaries. These results suggest that Ti/Ta phase boundaries are less conducive to the growth of large He bubbles than grain boundaries in the Ti-Ta single phase alloy.

36 MATERIALS SCIENCE↗

Using block-copolymer nanolithography as a tool to sensitively evaluate variation in chemical dry etching rates of semiconductor materials with sub-5 nm resolution

Ion implantation is a robust and established method to customize the electronic properties of Si. However, fabricating doped, ultrafine semiconductor nanostructures can be challenging. Ion implantation has well-established effects on the dry etch rates of Si, which becomes increasingly consequential as the target dimension shrinks below a few tens of nanometers. While dry etching arrays of block copolymer-templated nanoscale holes (pitch = 37.5 nm, diameter ~25 nm) into p-type, n-type, and undoped Si, we observed that the lateral etch rate was notably larger for the n-type regions than p-type or undoped regions. By doing image analyses on high resolution electron micrographs of the nanostructured hole arrays, we were able to extract the porosity and average radii of the holes with subnanometer sensitivity and compare the relative etch rates between different doping conditions. We found that degenerately doped n-type silicon consistently etches between approximately 17% and 27% faster in the lateral direction than p-type Si, resulting in significantly larger porosity and, consequently, less mechanical stability. Here, we demonstrate that top-down dimensional analysis of a densely packed porous nanostructure is a robust method for assessing extremely small differences in the lateral, chemical etch rate of doped Si to a degree of sensitivity that was previously unachievable. The minute, dense-packed nature of block copolymer self-assembled nanostructures is shown to be ideal for this application. This proposed method could be useful for designing fabrication processes for heterogeneous nanostructures, as slight dry etch rate variations that may be within process tolerance at the micrometer-scale appear to have nontrivial consequences at the nanometer scale.

42 ENGINEERING↗

A Printed Microscopic Universal Gradient Interface for Super Stretchable Strain‐Insensitive Bioelectronics

Abstract Stretchable electronics capable of conforming to nonplanar and dynamic human body surfaces are central for creating implantable and on‐skin devices for high‐fidelity monitoring of diverse physiological signals. While various strategies have been developed to produce stretchable devices, the signals collected from such devices are often highly sensitive to local strain, resulting in inevitable convolution with surface strain‐induced motion artifacts that are difficult to distinguish from intrinsic physiological signals. Here all‐printed super stretchable strain‐insensitive bioelectronics using a unique universal gradient interface (UGI) are reported to bridge the gap between soft biomaterials and stiff electronic materials. Leveraging a versatile aerosol‐based multi‐materials printing technique that allows precise spatial control over the local stiffnesses with submicron resolution, the UGI enables strain‐insensitive electronic devices with negligible resistivity changes under a 180% uniaxial stretch ratio. Various stretchable devices are directly printed on the UGI for on‐skin health monitoring with high signal quality and near‐perfect immunity to motion artifacts, including semiconductor‐based photodetectors for sensing blood oxygen saturation levels and metal‐based temperature sensors. The concept in this work will significantly simplify the fabrication and accelerate the development of a broad range of wearable and implantable bioelectronics for real‐time health monitoring and personalized therapeutics.

Song, Kaidong [Department of Aerospace and Mechani↗

Integration of polyurethane meniscus scaffold during ACL revision is not reliable at 5 years despite favourable clinical outcome

Abstract Purpose The aim of this study was to evaluate the clinical outcome at 5‐year follow‐up of a one‐step procedure combining anterior cruciate ligament (ACL) reconstruction and partial meniscus replacement using a polyurethane scaffold for the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy. Moreover, the implanted scaffolds have been evaluated by MRI protocol in terms of morphology, volume, and signal intensity. Methods Twenty patients with symptomatic knee laxity after failed ACL reconstruction and partial medial meniscectomy underwent ACL revision combined with polyurethane‐based meniscal scaffold implant. Clinical assessment at 2‐ and 5‐year follow‐ups included VAS, Tegner Activity Score, International Knee Documentation Committee (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm Score. MRI evaluation of the scaffold was performed according to the Genovese scale with quantification of the scaffold’s volume at 1‐ and 5‐year follow‐ups. Results All scores revealed clinical improvement as compared with the preoperative values at the 2‐ and 5‐year follow‐ups. However, a slight, but significant reduction of scores was observed between 2 and 5 years. Concerning the MRI assessment, a significant reduction of the scaffold’s volume was observed between 1 and 5 years. Genovese Morphology classification at 5 years included two complete resorptions (Type 3) and all the remaining patients had irregular morphology (Type 2). With regard to the Genovese Signal at the 5‐year follow‐up, three were classified as markedly hyperintense (Type 1), 15 as slightly hyperintense (Type 2), and two as isointense (Type 1). Conclusion Simultaneous ACL reconstruction and partial meniscus replacement using a polyurethane scaffold provides favourable clinical outcomes in the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy at 5 years. However, MRI evaluation suggests that integration of the scaffold is not consistent. Level of evidence Level IV.

Pereira, Hélder↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗