Search NASA⌕ Search

SEARCH · Search NASA

Results for “INLET FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Turboexpander for Direct Cooling in Hydrogen Vehicle Fueling Infrastructure

Hydrogen fuel cell electric vehicles (FCEVs) have been identified as one of a few options for zero carbon emissions transportation. A major advantage of FCEVs is that they can fuel quickly and follow a familiar fueling behavior to hydrocarbon-fueled vehicles. Whether light duty or heavy duty, the goal for a hydrogen dispenser is to fuel a vehicle in the same amount of time as the fossil fuel equivalent. When hydrogen is dispensed into the vehicle storage system, however, the temperature rises due to the Joule-Thomson effect and the heat of compression. Typically, vehicles store the compressed hydrogen in composite overwrapped pressure vessels that have a polymer liner with an operational temperature limit of 85°C. This temperature limit can be exceeded during fast fueling if hydrogen is not precooled. Precooling allows for a dispenser to fuel a vehicle at a faster flow rate by preventing the storage tank on the vehicle from overheating. Fueling protocols and requirements are presented in SAE J2601 Fueling Protocols for Light Duty Gaseous Hydrogen Surface Vehicles [1]. A heavy-duty equivalent is under development with similar requirements for precooling. Currently, conventional precooling for light-duty vehicle refueling uses a heat exchanger and chiller to cool the hydrogen gas to -40°C before entering the vehicle. The precooling system represents a significant part of the station capital and operating costs, so if the cost of the precooling system can be reduced by improving its efficiency, the overall station capital and operating cost can be reduced. In this project, National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) researchers teamed up to investigate the turboexpander precooling application. A turboexpander is a device that places a turbine in a flow path where a pressure differential can be attained. This expansion device will extract work and lower the temperature of the fluid as the pressure reduces. While initial calculations based on established principles showed potential for a turboexpander to generate cooled gas, much work needs to be done to prove the concept. Turboexpanders typically work best under steady state conditions, while the dispenser is a very dynamic flow system. Dynamic turboexpander systems have been proven, such as a turbocharger on a gasoline vehicle. The inlet pressure at a dispenser is also much higher than any other known turboexpander system but should behave similarly to higher density fluids at lower pressures. Having both performed initial calculations, NREL and SNL researchers teamed up to investigate the turboexpander precooling application further. A project was soon built around the idea with SNL performing system modeling using previously proven capabilities and NREL performing hardware characterization with established station capabilities. Creare LLC was contracted as the turbomachinery expert to design and build the concept device. Part way through the project, however, contracting issues with the funding partner caused the project to terminate early before building and characterizing the concept device. While the project could not continue, many key findings were already learned. This paper is a summary of those findings.

08 HYDROGEN↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Emergence of Unstable Focused Flow Induced by Variable‐Density Flows in Vertical Fractures

Abstract Fluids with different densities often coexist in subsurface fractures and lead to variable‐density flows that control subsurface processes such as seawater intrusion, contaminant transport, and geologic carbon sequestration. In nature, fractures have dip angles relative to gravity, and density effects are maximized in vertical fractures. However, most studies on flow and transport through fractures are often limited to horizontal fractures. Here, we study the mixing and transport of variable‐density fluids in vertical fractures by combining three‐dimensional (3D) pore‐scale numerical simulations and visual laboratory experiments. Two miscible fluids with different densities are injected through two inlets at the bottom of a fracture and exit from an outlet at the top of the fracture. Laboratory experiments show the emergence of an unstable focused flow path, which we term a “runlet.” We successfully reproduce the unstable runlet using 3D numerical simulations and elucidate the underlying mechanisms triggering the runlet. Dimensionless number analysis shows that the runlet instability arises due to the Rayleigh‐Taylor instability (RTI), and flow topology analysis is applied to identify 3D vortices that are caused by the RTI. Even under laminar flow regimes, fluid inertia is shown to control the runlet instability by affecting the size and movement of vortices. Finally, we confirm the emergence of a runlet in rough‐walled fractures. Since a runlet dramatically affects fluid distribution, residence time, and mixing, the findings in this study have direct implications for the management of groundwater resources and subsurface applications.

Environmental Sciences & Ecology↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program (Rev. 2)

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 and SHRT-6 were protected loss of flow tests where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R, SHRT-39, and SHRT-43R were unprotected loss of flow tests where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. PICT-5/6 demonstrated how core power could be increased and decreased via changes in the intermediate sodium and feedwater flow rates. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for all tests simulated there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative study of machine learning techniques for post-combustion carbon capture systems

Computational analysis of countercurrent flows in packed absorption columns, often used in solvent-based post-combustion carbon capture systems (CCSs), is challenging. Typically, computational fluid dynamics (CFD) approaches are used to simulate the interactions between a solvent, gas, and column's packing geometry while accounting for the thermodynamics, kinetics, heat, and mass transfer effects of the absorption process. These simulations can then be used explain a column's hydrodynamic characteristics and evaluate its CO 2 -capture efficiency. However, these approaches are computationally expensive, making it difficult to evaluate numerous designs and operating conditions to improve efficiency at industrial scales. In this work, we comprehensively explore the application of statistical ML methods, convolutional neural networks (CNNs), and graph neural networks (GNNs) to aid and accelerate the scale-up and design optimization of solvent-based post-combustion CCSs. We apply these methods to CFD datasets of countercurrent flows in absorption columns with structured packings characterized by several geometric parameters. We train models to use these parameters, inlet velocity conditions, and other model-specific representations of the column to estimate key determinants of CO 2 -capture efficiency without having to simulate additional CFD datasets. We also evaluate the impact of different input types on the accuracy and generalizability of each model. We discuss the strengths and limitations of each approach to further elucidate the role of CNNs, GNNs, and other machine learning approaches for CO 2 -capture property prediction and design optimization.

97 MATHEMATICS AND COMPUTING↗

Multifunctional intensified reactor device with integrated heat and mass transfer

A packing device for mass and heat transfer with a subject fluid includes a housing having opposing ends, and subject fluid openings at each opposing end defining a subject fluid flow path for at least one subject fluid flowing through the packing device. A plurality of mass and heat transfer plates each include an interior heat exchange fluid channel disposed between interior heat transfer surfaces of the mass and heat transfer plates. A heat exchange fluid inlet and fluid outlet can supply and remove heat exchange fluid to the heat exchange fluid channels of the mass and heat transfer plates. The mass and heat transfer plates can be oriented to define there between fluid flow channels for the subject fluid. A method and system for mass and heat transfer with a subject fluid, and a method and system for the removal of CO2 from a gas stream are disclosed.

Lai, Canhai↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Network Based Estimation of Wind Farm Power and Velocity Data Under Changing Wind Direction

This paper describes an estimation algorithm for velocity and power output signals in a wind farm under changing wind direction. A graph-theoretic definition describes the wind farm as a collection of nodes (turbines) and time-varying weighted edges (inter-turbine wake propagation) that change as a function of incoming wind direction. The velocity at each turbine is determined through a discrete input-output model. Changes in wind direction serve as the input and the output is defined in terms of a time-varying weighted adjacency matrix that depends on the time-delay of information propagation between turbines. These delays, which are defined in terms of the advection speed of the wind and the distance between the turbines, capture the delayed effect of wind direction changes on the inter-connectivity of the graph as the wind conditions at the farm inlet propagate through the turbine array. An event-based update framework is employed to capture time-dependent topology changes due to shifts in wind direction. Simulation results for dynamically changing wind inlet directions to a circular wind farm are compared to predictions from both the static and dynamic versions of the FLOw Redirection and Induction in Steady State (FLORIS) model. The approach is shown to enable real-time tracking of dynamic changes to wind farm power output within a framework that can be easily integrated into real-time, horizon-based, control strategies that typically do not account for wind direction changes.

distributed↗

On the subject of large-scale pool fires and turbulent boundary layer interactions

The role to which a realistic inflow turbulent boundary layer (TBL) influences transient and mean large-scale pool fire quantities of interest (QoIs) is numerically investigated. High-fidelity, low-Mach large-eddy simulations that activate low-dissipation, unstructured numerics are conducted using an unsteady flamelet combustion modeling approach with mutiphysics coupling to soot and participating media radiation transport. Three inlet profile configurations are exercised for a large-scale, high-aspect rectangular pool that is oriented perpendicular to the flow direction: a time-varying, TBL inflow profile obtained from a periodic precursor simulation, the time-mean of the transient TBL, and a steady power-law inflow profile that replicates the mean TBL crosswind velocity of 10.0 m/s at a vertical height of 10 m. Results include both qualitative transient flame evolution and quantitative flame shape with ground-level temperature and convective/radiative heat flux profiles. While transient fire events, which are driven by burst-sweep TBL coupling, such as blow-off and reattachment are vastly different in the TBL case (contributing to increased root mean square QoI fluctuation prediction and disparate flame lengths), mean surface QoI magnitudes are similar. Quadrant analysis demonstrates that the TBL configuration modifies burst-sweep phenomena at windward pool locations, while leeward recovery is found. In conclusion, positive fluctuations of convective heat flux correlate with fast moving fluid away from the pool surface due to intermittent combustion events.

97 MATHEMATICS AND COMPUTING↗

Investigations into Plasma-Mediated Decomposition of Organoiodide Species as a Pretreatment for Mitigation of Radioiodine Emissions

A plasma-mediated pretreatment step is proposed to decompose methyl iodide (CH 3 I) for facilitating the capture of the iodine radioisotopes present in off-gas streams from used nuclear fuel reprocessing operations. Simulated CH 3 I gas streams were exposed to dielectric barrier discharge (DBD) plasma in a quartz glass continuous-flow reactor using copper electrodes. The kinetics of decomposition of CH 3 I in nitrogen was investigated by varying the applied voltage, inlet concentration, and residence time. The rate of decomposition was proportional to CH 3 I concentration and increased as the applied potential was increased. This effect was incorporated in the kinetics through the dependence of the rate constant on the applied electric field. Decomposition of CH 3 I was not affected by moisture, and the DBD pretreatment is likely to be similarly effective in an air environment as well; however, the results were confounded by a plasma-mediated reaction between nitrogen and oxygen.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Water and Solute Activities Regulate CO 2 Reduction in Gas-Diffusion Electrodes

Electrolysis of CO 2 at gas-diffusion electrodes (GDEs) has typically been limited by the supply of gas to the electrocatalyst, overshadowing the importance of the supply of water. However, at high current densities that approach 1 A cm –2 , where the electrolyte becomes highly concentrated in the catalyst layer of a GDE, the activity of water and solutes deviate from their bulk dilute solution values, potentially slowing reaction rates and changing reaction equilibrium potentials. In addition, as flow plates for the gas stream are introduced to enable larger electrodes and high single pass conversion of CO 2 to product, variations in the gas composition will become important. By drawing upon literature for the oxygen reduction reaction (ORR), here we explain how to account for these effects in future modeling and experimental work, with particular attention to accurate use of the Nernst equation for electrode potentials and the Arrhenius equation for reaction rates. Specifically, using measurements of KOH solvent and solute activity reported in literature, and assuming the second protonation of CO 2 by water as the rate-determining step, we show the Nernst equation dilute-solution approximation of the CO 2 to CO equilibrium potential to be accurate below 5 M KOH, but it has a 74 mV error when increasing the concentration up to 10 M KOH. Finally, a simple one-dimensional model of a serpentine flow-field on a GDE demonstrated that a reactor with constant pressure of 1 bar and 1 A cm –2 at the inlet had only ~0.3 A cm –2 at the outlet for a conversion in CO 2 partial pressure from 0.90 to 0.48 bar, showing the significant practical implications of this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NMDQi Thermal-hydraulic Optimization, Analysis, and Scoping Tool (TOAST)

The Thermal-hydraulic Optimization, Analysis, and Scoping Tool (TOAST) is developed to support the thermal-hydraulic aspects for the design of optimal irradiation vehicles for the Nuclear Materials Discovery and Qualification initiative (NMDQi). TOAST is currently a MATLAB-based tool that utilizes a simplified steady-state analytical model where a radial thermal resistance circuit is utilized to account for conduction through up to 2 capsules, a gas gap, a thermal bond, a sample cladding, and a sample, as well as the convection from a water coolant outside the capsules. The geometry is discretized axially along the user-defined height of a basket with a user-defined number of points/nodes, essentially turning TOAST into a semi-2D heat transfer analysis utility for cylindrical irradiation vehicles with practically any configuration, solving for temperatures radially at multiple axial locations. TOAST utilizes a Graphical User Interface (GUI) in-which a user can define the geometrical layout, the materials utilized for each component, the coolant characteristics, and the required solution. The user can define the geometry by inputting the diameters, thicknesses, and heights for each component, whereas the materials are defined via the user-provided constant or variable thermal conductivities. The user can select the coolant's inlet temperature, pressure, and the pressure drop across the height of the problem (which is used to calculate the velocity of the flow). Finally, the user can choose to solve for a sample heat generation rate limit by inputting temperature limits for the sample and capsules or can choose to purely solve for the axial temperature distributions of each component by inputting a pre-selected heat generation rate. Either way, TOAST provides the user with axial temperature distributions of all the components including the coolant, and the heat generation rate limit as well as the maximum outlet coolant temperature. The user can also choose to do one of 6 sensitivity analyses in TOAST. The sensitivity analyses yield plots of the sensitivity of the heat generation rate limit, the maximum coolant temperature, and the pressure limit for the annular components due to perturbations in 1-2 unknown variables based on the selected sensitivity analysis. Benchmarks between computations in TOAST and equivalent 2D axis symmetric ABAQUS models are presented, showing that TOAST results are within less than 3% of ABAQUS results in most cases, and a maximum of 8% difference in some cases. The benchmarks also revealed that this uncertainty is tied to the selection of an appropriate Nusselt number correlation and appropriate thermal conductivities, which the user can do from the GUI. Regardless, TOAST is demonstrated as a computationally efficient, highly accessible, and accurate utility for optimization and scoping s of studies different irradiation vehicles.

42 ENGINEERING↗

Laser ablation spectrometry system

This disclosure provides systems, methods, and apparatus related to laser ablation spectrometry systems. In one aspect, a system comprises a microscope, a laser, a continuous flow probe, and a gas confinement device. The laser is positioned to emit light through an objective lens of the microscope. The continuous flow probe is coupled to a spectrometer. An end of the continuous flow probe is positioned proximate a sample and between the sample and the objective lens. The gas confinement device defines a gas inlet, a chamber, a platform, a wall surrounding the platform, a plurality of vents, and a plurality of channels. Each of the plurality of vents is positioned to direct a gas substantially parallel to the platform, and each of the plurality of vents is defined in the wall. The plurality of channels is operable to provide fluid communication between the chamber and the plurality of vents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PERFORMANCE CHARACTERIZATION OF THE DIRECT CONTACT MEMBRANE DISTILLATION MODULE OPERATED WITH HIGHLY CONCENTRATED SOLUTION

The experimental study was conducted to characterize the performance of the flat sheet Direct Contact Membrane Distillation. The length degradation was studied in a short and long module with and without spacers. The experimental study is validated using the predicted flux for a wide range of operating conditions using deionized water. Three different membranes are used in the parametric study for feed Reynolds number varied between 500 and 2000, and inlet feed temperature varied between 45°C and 80°C. PTFE membrane was shown to be more effective than the PVDF due to its higher permeability coefficient and higher hydrophobicity. Fouling study was conducted on the selected PTFE membrane with various feed Reynolds numbers between 500 and 2000 and feed inlet temperature between 50°C and 80°C. Membranes used in the fouling study were characterized using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) for the morphology and chemical composition of the fouling layer. 36 hours of operation with 10 wt% NaCl (100,000 ppm) at feed inlet temperatures 80°C and 60°C and fixed Reynolds 2000 demonstrated a drop in flux by 31% and 27%, respectively. Low flow rate and high temperature are favorable conditions for fouling formation and reduced permeate flux for highly concentrated solutions. The spacers improved the flux by 30.8% and 27.6% at the operating Reynolds numbers 2000 the short and long channel modules. This study helps to design and optimize DCMD modules for industrial-size desalination and water treatment applications.

Kim, Deliya↗

Core-flood Effluent and Shale Surface Chemistries in Predicting Interaction between Shale, Brine, and Reactive Fluid

We report field and laboratory observations to date indicate that the efficiency of hydraulic fracturing, as it relates to hydrocarbon recovery, depends significantly on geochemical alterations to rock surfaces that diminish accessibility by partial or total plugging of the pore and fracture networks. This is caused by mineral scale deposition such as coating of fracture surfaces with precipitates, particle migration, and/or crack closure due to dissolution under stress. In reactive flow-through experiments, mineral reactions in response to acidic fluid injection significantly reduced system porosity and core permeability. The present study focuses on changes to fluid chemistry and shale surfaces (inlet and fracture walls) resulting from shale-fluid interactions and integrating these findings for an improved estimate of transport-related consequences. The reacted shale surfaces were examined by spatially-resolved scanning electron microscopy - energy dispersive spectroscopy (SEM-EDS) analysis. Importantly, inductively coupled plasma - mass spectrometry/optical emission spectroscopy (ICP-MS/OES) was utilized to probe the chemical evolution of the core-flood effluents. The three study cores selected from the Marcellus formation represent different mineralogies and structural features. In flow-through experiments, lab-generated brine and HCl-based fracture fluid (pH=2) were injected sequentially under effective stress (up to 500 psi) at reservoir temperature (80°C). SEM-EDS results confirmed by the ICP concentration trends showed significant Fe hydroxide precipitates in clay- and pyrite-rich outcrop samples due to partial oxidation of Fe-bearing phases in the case of intrusion of low salinity water-based fluids. Porosity reduction in the MSEEL (Marcellus Shale Energy and Environmental Laboratory) carbonate-rich sample is related to compaction of cores under stress due to matrix softening with substantial dissolution, and pore-filling by hydroxides, as well as barite and salts. Despite the same fluid compositions and experimental conditions used for both MSEEL samples, barite precipitation was much more intense in the MSEEL clay-rich sample due to its greater sorption capacity and additional sulfate source as well as fissile nature with multiple lengthwise cracks. ICP tests revealed time-resolved concentration trends in produced brine and reactive fluids that in turn complemented the pre-/post-reaction SEM-EDS observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗