Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Irradiation route to aqueous synthesis of highly luminescent ZnSe quantum dots and its function as a copper ion fluorescence sensor

Highlights: • Radiation chemical technique can provide a useful route for synthesis of ZnSe QDs. • Chelating nature of ethylene diamine is exploited for capping nanoparticles. • ZnSe QDs can be a suitable sensitive alternative to toxic cadmium-based system. • Cu(II) ion is probed by QDs in the presence of other physiologically relevant ions. - Abstract: Size-controlled synthesis of stable ZnSe QDs with narrow distribution in aqueous environment through conventional soft chemical method still poses a challenge. The proposed radiation assisted strategy demonstrates aqueous synthesis of stable, monodisperse and luminescent ZnSe QDs capped with chelating ethylene diamine under ambient conditions and at room temperature. Radiation chemical method facilitates in slow and in-situ release of selenium ion from sodium selenosulfate. The concentrations of precursors, such as zinc salt, selenium source, ethylene diamine and absorbed radiation (7–90 kGy) dose were optimized for obtaining good quality particles. Selective quenching of luminescence of as-synthesized quantum dots (QDs) by Cu{sup 2+} ions vis-à-vis other physiologically important cations provide evidence for use of ZnSe quantum dots as alternative to toxic Cd-based quantum dots to probe Cu{sup 2+} ions. The linear relation of ratio of loss in emission intensity as a function of concentration of Cu(II) indicates detection limit in nano-molar range.

36 MATERIALS SCIENCE↗

Modeling positive ion current to a planar probe in low-pressure electronegative discharges

A fluid model is utilized to describe the plasma-sheath boundary for a negatively biased planar probe immersed in electronegative plasmas. The model equations are solved on the scale of the electron Debye length and calculate the spatial distributions of electric potential, velocity, and density of positive ions in front of the probe. The position of sheath edge, the positive ion velocity at sheath edge (the Bohm velocity), and the positive ion flux collected by the probe are determined and compared with analytic (or scaling) formulas. Effects of control parameters on the Bohm velocity, the sheath thickness, and on the positive ion flux are investigated. A larger thermal motion of negative ions causes the Bohm velocity to increase, the sheath to increase, and the positive ion flux collected by the probe to increase. An increase in collision causes the Bohm velocity to decrease and the sheath to decrease resulting in a decrease in the positive ion flux. An increase in electronegativity causes both the Bohm velocity and the sheath thickness to decrease, resulting in an increase in the positive ion flux. As the value of the non-neutrality parameter q increases, the Bohm velocity and the sheath thickness are found to decrease, and the positive ion flux collected by the probe increases. The behavior of the positive ion flux entering the sheath is discussed as functions of control parameters. A careful comparison of theoretical positive ion flux with the experimental flux can allow us to obtain the electronegativity, the plasma ionization rate (q), and the collision parameter ({delta})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of plasma density from data on the ion current to cylindrical and planar probes

To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models were used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Barium ion sensing with IPG K + molecular probes

Fluorophores covalently bound to azacrown ether ionophores can be assembled into sensitive turn-on chemosensors. The size specificity and electron-rich nature of the ionophore's binding domain contribute to both selectivity and strong turn-on fluorescence sensing by various mechanisms when properly constructed. Aza-18-crown-6 ethers are quite selective for binding to K + and Ba 2+ , yet the more electron-withdrawing dicationic nature of barium imposes a larger electronic effect on turn-on fluorescent sensors. Barium chemosensors can be important for measuring soluble Ba 2+ in drinking water and have gained recent attention for their potential to enhance the detection of rare events in xenon decay. Here we quantify the capability of three chemosensors, marketed for biologically useful K + sensing, as effective probes for Ba 2+ ions. Here, we present measurements from bulk spectrofluorometry to characterize the system in aqueous solutions and demonstrate the usefulness of these species for low-background single-ion fluorescence microscopy, revealing new candidates for Ba 2+ sensing.

Miller, R. L. [Department of Chemistry and Biochem↗

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x10{sup 14} ions cm{sup -2}. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm{sup -1} compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced {sup 12}C(d,p){sup 13}C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ion implanted silicon. Various implantations with N{sub 2}, O{sub 2}, NO, NO{sub 2} and Pb ions were performed with and without cooling of the liquid nitrogen trap. Simultaneous detection of ppm-level concentrations of {sup 12}C, {sup 16}O and {sup 14}N enables highly sensitive measurement of impurities that may be incorporated during the fabrication process, transport of the samples and/or storage of the samples in air.

36 MATERIALS SCIENCE↗

A simple model of the positive ion sheath in front of a plane probe in weakly ionized electropositive plasmas

This paper describes the positive ion sheath in front of a plane probe in weakly ionized electropositive plasmas. The results obtained are the potential profile in front of the probe and the probe positive ion current to voltage characteristic curves that have been analytically fitted as a function of the probe potential and the plasma ionization rate. Finally, the floating potential for an argon plasma has been calculated by considering a parametrization of the model obtained from the fitted characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

Johnsen, R.↗

In-flight calibration of mesospheric rocket plasma probes

Many effects and factors can influence the efficiency of a rocket plasma probe. These include payload charging, solar illumination, rocket payload orientation and rotation, and dust impact induced secondary charge production. As a consequence, considerable uncertainties can arise in the determination of the effective cross sections of plasma probes and measured electron and ion densities. We present a new method for calibrating mesospheric rocket plasma probes and obtaining reliable measurements of plasma densities. This method can be used if a payload also carries a probe for measuring the dust charge density. It is based on that a dust probe's effective cross section for measuring the charged component of dust normally is nearly equal to its geometric cross section, and it involves the comparison of variations in the dust charge density measured with the dust detector to the corresponding current variations measured with the electron and/or ion probes. In cases in which the dust charge density is significantly smaller than the electron density, the relation between plasma and dust charge density variations can be simplified and used to infer the effective cross sections of the plasma probes. We illustrate the utility of the method by analysing the data from a specific rocket flight of a payload containing both dust and electron probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion composition and dynamics at comet Halley

The Giotto space probe's ion mass spectrometer has obtained data on the composition and velocity distributions of cometary ions at distances of between 7.5 million and 1300 km from the comet Halley nucleus. Solar wind He(2+) was found throughout the coma, as close as 5000 km, with the He(+) produced by charge exchange being within about 200,000 km. A pile-up of heavy cometary ions was found at about 10,000 km from the nucleus. Inside the contact surface, which was found at about 4600 km, ion temperatures as low as about 340 K and outflow velocities of about 1 km/sec were found.

Balsiger, H.↗

Evaluation of ion collection area in Faraday probes

A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the influence of ion-pairing on ligand-field excited-state dynamics

Exploration of the photophysical and photochemical properties of transition metal complexes has driven ground-breaking advancements in solar energy conversion technologies, including photoredox catalysis. While significant research has been devoted to understanding excited state properties of second- and third-row transition metal complexes, earth-abundant first-row metal complexes have received comparatively little attention in this context until very recently. In particular, the role of ion-pairing – which has been identified as a potentially significant factor for Ir(III)-based photosensitizers – has not been examined with regard to its influence on the ligand-field excited states that dominate much of first-row photophysics. A key challenge in studying ion-pair interactions lies in quantifying the extent and nature of ion-pairing, particularly in non-aqueous media where the vast majority of photophysical studies are performed. Cobalt(III) polypyridyl complexes provide an attractive platform to address such questions due to their demonstrated potential for applications in photoredox catalysis involving ligand-field excited states. In the present study, we prepared a cobalt(III) polypyridyl complex, [Co(4,4′-OMebpy) 3 ](BAr F 4 ) 3 (where 4,4′-OMebpy is 4,4′-dimethoxy-2,2′-bipyridine and BAr F 4 is tetrakis(3,5-bis(trifluoromethyl)-phenyl)borate) to probe ion-pairing in non-aqueous solutions. Specifically, analysis of data acquired from both variable-temperature diffusion ordered spectroscopy (DOSY) NMR and 1-D rotating-frame nuclear Overhauser effect (ROE) experiments allowed us to identify and differentiate between solvent-separated ion pairs in high-dielectric media and contact ion pairs in a low-dielectric solvent. Time-resolved absorption spectroscopy was then used to measure ground-state recovery dynamics under these varying conditions of ion-pairing, the results of which revealed an increase in excited-state lifetime for contact ion-pairs that we suggest arises from a reduction in outer-sphere reorganization energy relative to conditions which favored solvent-separated ion pairs. We believe this study demonstrates that one can leverage broadly available NMR-based methods to understand ion-pairing in non-aqueous solutions, which in turn can provide a microscopic picture of intermolecular interactions that can impact the photophysical properties of transition metal-based chromophores.

Ghosh, Atanu [Michigan State University, East Lans↗

Rotational spectrum of the molecular ion NH{sup +} as a probe for {alpha} and m{sub e}/m{sub p} variation

We identify the molecular ion NH{sup +} as a potential candidate for probing variations in the fine-structure constant {alpha} and electron-to-proton mass ratio {mu}. NH{sup +} has an anomalously low-lying excited {sup 4}{Sigma}{sup -} state, being only a few hundred cm{sup -1} above the ground {sup 2}{Pi} state. Being a light molecule, this proximity is such that rotational levels of the respective states are highly intermixed for low angular momenta. We find that several low-frequency transitions within the collective rotational spectrum experience enhanced sensitivity to {alpha} and {mu} variation. This is attributable to the close proximity of the {sup 2}{Pi} and {sup 4}{Sigma}{sup -} states, as well as the ensuing strong spin-orbit coupling between them. Suggestions that NH{sup +} may exist in interstellar space and recent predictions that trapped-ion precision spectroscopy will be adaptable to molecular ions make NH{sup +} a promising system for future astrophysical and laboratory studies of {alpha} and {mu} variation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Electrochemical Mg-Ion Activity in MgCr 2– x V x O 4 Spinel Oxides

Mg migration in oxide spinels is impeded by strong affinity between divalent Mg and oxygen, suggesting a necessity of exploring new chemistry of solid lattices for functional Mg-ion electrode materials. Cationic mobility with a suitable activation energy in Cr spinels is Tn. evidenced by theoretical and experimental results, while redox potentials of V are appropriate to operate with currently limited candidates of '''c" nonaqueous electrolytes. By controlling the structure, composition, and complexity, a largely solid-solution MgCrVO 4 spinel was synthesized, which, unlike nanocornposites, can bring together the advantages of each transition metal in the lattice. The spinel was successfully synthesized by a simple solid-state reaction with minor inactive Cr- or V-rich components, which was confirmed via 25 Mg MAS NMR and high-resolution X-ray diffraction analyses. A thermally and anodically stable Mg(TPFA) 2 /triglyme electrolyte was utilized for high-temperature electrochemistry and lowering kinetic barriers at and across interfaces so as to observe intercalation behavior of Mg in the designed lattice. Multimodal characterization confirmed an apparent bulk demagnesiation from MgCrVO 4 with partial reversibility by probing evolution of the local and long-range structure as well as vanadium and chromium electronic states within the lattice. Furthermore, characterization experiments also provided a direct evidence for (de)intercalation reactions that occurred without any major competitive conversion reactions or insertion of protons into the lattice, except for the formation of a surface rock salt phase upon charge. These findings in Mg-ion activity expand opportunities to design Mg spinel oxide materials while highlighting the need to identify the origins of reversibility challenges due to, but not limited to, phase stability, particularly for the charged states, barriers at the interface, electrolyte stabilities, and desolvation phenomena, collectively hindering practical use as cathode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast-ion transport by Alfvén eigenmodes above a critical gradient threshold

Experiments on the DIII-D tokamak have identified how multiple simultaneous Alfvén eigenmodes (AEs) lead to overlapping wave-particle resonances and stochastic fast-ion transport in fusion grade plasmas [C. S. Collins et al., Phys. Rev. Lett. 116, 095001 (2016)]. The behavior results in a sudden increase in fast-ion transport at a threshold that is well above the linear stability threshold for Alfvén instability. A novel beam modulation technique [W. W. Heidbrink et al., Nucl. Fusion 56, 112011 (2016)], in conjunction with an array of fast-ion diagnostics, probes the transport by measuring the fast-ion flux in different phase-space volumes. Well above the threshold, simulations that utilize the measured mode amplitudes and structures predict a hollow fast-ion profile that resembles the profile measured by fast-ion Dα spectroscopy; the modelling also successfully reproduces the temporal response of neutral-particle signals to beam modulation. The use of different modulated sources probes the details of phase-space transport by populating different regions in phase space and by altering the amplitude of the AEs. Both effects modulate the phase-space flows.

Heidbrink, W. W.↗

Correlation of plasma characteristics to etch rate and via sidewall angle in a deep reactive ion etch system using Langmuir probe and optical emission spectroscopy

A Langmuir probe and optical emission spectroscopy were used in a deep reactive ion etch system to correlate plasma parameters (atomic fluorine and argon emission, electron density, ion density, and electron average energy) with the etch rate and via sidewall angle. All data were obtained for coil powers ranging from 200 to 800 W, platen powers ranging from 7 to 16 W, and pressure ranging from 3.8 to 62 mTorr with constant SF{sub 6} and Ar flow rates of 112 and 18 SCCM (SCCM denotes cubic centimeter per minute at STP), respectively. Results indicate that there is a correlation with etch rate for all plasma parameters except for argon emission. For argon emission, the etch rate exhibits a double-valued relation where the etch rate can either increase or decrease with increasing argon emission intensity due to changes in pressure which affect the energy coupling efficiency. As expected, the etch rate increases for measured increases in fluorine emission, electron density, and ion density. The etch rate, however, decreases with increasing average electron energy due to collision processes. In contrast, no correlation is observed between any of the measured plasma parameters with sidewall angle. The last result is consistent with the idea that sidewall angle is primarily controlled by the passivation cycle as opposed to the etching cycle, where all the authors' data were obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical experiment to estimate the validity of negative ion diagnostic using photo-detachment combined with Langmuir probing

This paper presents a critical assessment of the theory of photo-detachment diagnostic method used to probe the negative ion density and electronegativity α = n{sub -}/n{sub e}. In this method, a laser pulse is used to photo-detach all negative ions located within the electropositive channel (laser spot region). The negative ion density is estimated based on the assumption that the increase of the current collected by an electrostatic probe biased positively to the plasma is a result of only the creation of photo-detached electrons. In parallel, the background electron density and temperature are considered as constants during this diagnostics. While the numerical experiments performed here show that the background electron density and temperature increase due to the formation of an electrostatic potential barrier around the electropositive channel. The time scale of potential barrier rise is about 2 ns, which is comparable to the time required to completely photo-detach the negative ions in the electropositive channel (∼3 ns). We find that neglecting the effect of the potential barrier on the background plasma leads to an erroneous determination of the negative ion density. Moreover, the background electron velocity distribution function within the electropositive channel is not Maxwellian. This is due to the acceleration of these electrons through the electrostatic potential barrier. In this work, the validity of the photo-detachment diagnostic assumptions is questioned and our results illustrate the weakness of these assumptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗