Neutron production and dosimetry with D(D,n) 3 He, 12 C(D,n) 13 N and 7 Li(p,n) 7 Be reactions at the Sandia Ion Beam Laboratory

Neutrons are produced at the Sandia Ion Beam Laboratory (IBL) using a beam of 280 keV D 2 + ions onto an erbium deuteride target. At test locations in the forward direction these neutrons have energies of about 2.9 MeV and a maximum flux on the flange of the test chamber of about 10 10 n/cm 2 /hour. Dosimetry is done by counting associated charged particles and by nickel foil activation dosimetry. Neutrons with higher energies, up to 6 MeV are produced using higher energy deuterium, up to 3 MeV, from the Pelletron ion accelerator at the IBL on a deuteride target. This report provides detailed information on the methods used for the production and dosimetry of neutrons by the D(D,n) 3 He nuclear reaction at the IBL. Neutron production by the 7 Li(p,n) 7 Be reaction with a proton beam from the Pelletron on a lithium target, such as LiF is also discussed. This produces neutrons with lower energy, in the range from about 0.1 to 1.3 MeV. Neutron production by the 12 C(D,n) 13 N reaction is also discussed. The purpose of this report is to provide information needed to test the effects of neutron irradiation on semiconductor materials and devices at the Sandia IBL.

36 MATERIALS SCIENCE↗

Nuclear Material Control and Accountancy Approach for Pebble Fueled Reactors using a Novel Pebble-Type Identification and Classification Technology

In FY21, Argonne National Laboratory (ANL) with researchers at Texas A&M University (TAMU) designed and engineered a prototypical device for accounting types of irradiated pebbles (for example with different 235U enrichments or pure graphite) in Pebble-Fueled Reactors (PFRs). Through engagements with reactor designers, a need arose to assist in identifying and categorizing types of pebbles as a complementary nuclear material control method that would synergize with designers’ use of fuel burnup measurements for material accountancy needs. As part of an overall nuclear material control approach, a concept of pebble batch accounting was investigated using extrinsic non-radiological features to identify intrinsic characteristics. This concept of batch accounting led to the ability of identifying types of pebbles based on characteristics such as initial 235U enrichment of pebble batches or dates of introduction into the reactor core. Identification was achieved by embedding the 5-mm thick graphite periphery of pebbles with 2-mm diameter inert Yttria-Stabilized Zirconia (YSZ) microspheres to achieve an averaged volumetric density (i.e., common spacing between microspheres) unique to that type of pebble. With an ultrasound imaging system in proximity with each pebble, the YSZ microspheres in the pebble proved visible and their spacing became the unique feature upon which pebble type categorization could occur. At the culmination of FY21, ANL intended on delivering and installing the prototype at TAMU for initial testing but, due to the on-going pandemic, this was postponed until FY22.

Gariazzo, Claudio↗

Effects of Hydrogen on the Radiation Response of Bipolar Transistors: Experiment and Modeling

Reactions of H2 in lateral PNP BJTs are investigated through experiments and simulations. Pre-irradiation hydrogen exposure makes the devices more sensitive to ionizing radiation, which is explained through first principles calculations and numerical simulations. Mechanisms for the cracking of hydrogen molecules and proton generation are proposed. We also suggest a mechanism of formation of border traps. When protons are trapped by oxygen vacancies right at or very near the interface they form electrically active defects near the middle of the band gap. Activation energies of the reaction are used to construct rate equations. The rate equations are solved numerically to determine the spatial and temporal concentrations of hydrogen, holes, and protons. The calculated concentrations of interface and border traps agree reasonably well with the experimental results and indicate that the concentration of hydrogen plays a pivotal role in determining the total-dose response of BJTs.

36 MATERIALS SCIENCE↗

Optimal electron irradiation as a tool for functionalization of MoS{sub 2}: Theoretical and experimental investigation

We demonstrate the utility of electron irradiation as a tool to enhance device functionality of graphene-analogous MoS{sub 2}. With the help of first-principles based calculations, vacancy-induced changes of various electronic properties are shown to be a combined result of crystal-field modification and spin-orbital coupling. A comparative theoretical study of various possible vacancy configurations both in bulk and monolayer MoS{sub 2} and related changes in their respective band-structures help us to explain plausible irradiation induced effects. Experimentally, various structural forms of MoS{sub 2} in bulk, few layered flakes, and nanocrystals are observed to exhibit important modification of their magnetic, transport, and vibrational properties, following low doses of electron irradiation. While irradiated single crystals and nanocrystals show an enhanced magnetization, transport properties of few-layered devices show a significant increase in their conductivity, which can be very useful for fabrication of electronic devices. Our theoretical calculations reveal that this increase in n-type conductivity and magnetization can be correlated with the presence of sulfur and molybdenum vacancies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of the Effects of High-Energy Photon Beam Irradiation (10 and 18 MV) on 2 Types of Implantable Cardioverter-Defibrillators

Purpose: Radiation therapy for cancer may be required for patients with implantable cardiac devices. However, the influence of secondary neutrons or scattered irradiation from high-energy photons (≥10 MV) on implantable cardioverter-defibrillators (ICDs) is unclear. This study was performed to examine this issue in 2 ICD models. Methods and Materials: ICDs were positioned around a water phantom under conditions simulating clinical radiation therapy. The ICDs were not irradiated directly. A control ICD was positioned 140 cm from the irradiation isocenter. Fractional irradiation was performed with 18-MV and 10-MV photon beams to give cumulative in-field doses of 600 Gy and 1600 Gy, respectively. Errors were checked after each fraction. Soft errors were defined as severe (change to safety back-up mode), moderate (memory interference, no changes in device parameters), and minor (slight memory change, undetectable by computer). Results: Hard errors were not observed. For the older ICD model, the incidences of severe, moderate, and minor soft errors at 18 MV were 0.75, 0.5, and 0.83/50 Gy at the isocenter. The corresponding data for 10 MV were 0.094, 0.063, and 0 /50 Gy. For the newer ICD model at 18 MV, these data were 0.083, 2.3, and 5.8 /50 Gy. Moderate and minor errors occurred at 18 MV in control ICDs placed 140 cm from the isocenter. The error incidences were 0, 1, and 0 /600 Gy at the isocenter for the newer model, and 0, 1, and 6 /600Gy for the older model. At 10 MV, no errors occurred in control ICDs. Conclusions: ICD errors occurred more frequently at 18 MV irradiation, which suggests that the errors were mainly caused by secondary neutrons. Soft errors of ICDs were observed with high energy photon beams, but most were not critical in the newer model. These errors may occur even when the device is far from the irradiation field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flash healing of laser-induced graphene

The advancement of laser-induced graphene (LIG) technology has streamlined the fabrications of flexible graphene devices. However, the ultrafast kinetics triggered by laser irradiation generates intrinsic amorphous characteristics, leading to high resistivity and compromised performance in electronic devices. Healing graphene defects in specific patterns is technologically challenging by conventional methods. Herein, we report the rapid rectification of LIG’s topological defects by flash Joule heating in milliseconds (referred to as F-LIG), whilst preserving its overall structure and porosity. The F-LIG exhibits a decreased I D /I G ratio from 0.84 – 0.33 and increased crystalline domain from Raman analysis, coupled with a 5-fold surge in conductivity. Pair distribution function and atomic-resolution imaging delineate a broader-range order of F-LIG with a shorter C-C bond of 1.425 Å. The improved crystallinity and conductivity of F-LIG with excellent flexibility enables its utilization in high-performance soft electronics and low-voltage disinfections. Notably, our F-LIG/polydimethylsiloxane strain sensor exhibits a gauge factor of 129.3 within 10% strain, which outperforms pristine LIG by 800%, showcasing significant potential for human-machine interfaces.

36 MATERIALS SCIENCE↗

Performance enhancement of fullerene based solar cells upon NIR laser irradiation

Photovoltaic performance enhancement of fullerene based solar cells was achieved upon exposure to near-infrared (NIR) laser pulses. In this work, the solar cells were fabricated with poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl C 61 -butyric acid methyl ester (PCBM) under ambient conditions. The cells were then post-treated with NIR femto-second laser pulses at 800 nm for different intervals of time. An enhancement of 50% in the power conversion efficiency was achieved for the devices with 15 minutes of NIR laser irradiation compared to that of the control device. The enhancement in the power conversion efficiency is attributed to the formation of a covalent linkage between P3HT and PCBM as suggested by Matrix-assisted laser desorption/ionization time of flight mass spectroscopic analysis on a blend of a thiophene oligomer and PCBM before and after NIR laser exposure.

36 MATERIALS SCIENCE↗

Luminescence imaging of water during carbon-ion irradiation for range estimation

Purpose: The authors previously reported successful luminescence imaging of water during proton irradiation and its application to range estimation. However, since the feasibility of this approach for carbon-ion irradiation remained unclear, the authors conducted luminescence imaging during carbon-ion irradiation and estimated the ranges. Methods: The authors placed a pure-water phantom on the patient couch of a carbon-ion therapy system and measured the luminescence images with a high-sensitivity, cooled charge-coupled device camera during carbon-ion irradiation. The authors also carried out imaging of three types of phantoms (tap-water, an acrylic block, and a plastic scintillator) and compared their intensities and distributions with those of a phantom containing pure-water. Results: The luminescence images of pure-water phantoms during carbon-ion irradiation showed clear Bragg peaks, and the measured carbon-ion ranges from the images were almost the same as those obtained by simulation. The image of the tap-water phantom showed almost the same distribution as that of the pure-water phantom. The acrylic block phantom’s luminescence image produced seven times higher luminescence and had a 13% shorter range than that of the water phantoms; the range with the acrylic phantom generally matched the calculated value. The plastic scintillator showed ∼15 000 times higher light than that of water. Conclusions: Luminescence imaging during carbon-ion irradiation of water is not only possible but also a promising method for range estimation in carbon-ion therapy.

60 APPLIED LIFE SCIENCES↗

Radiation Effects in III-V Solar Cells Grown by Dynamic Hydride Vapor Phase Epitaxy

The recent development of hydride vapor phase epitaxy (HVPE) is potentially promising as a route to lower the cost of high-efficiency III-V solar cells for space applications. HVPE produces the same materials and device structures as the industry-standard organometallic vapor phase epitaxy (OMVPE) process, and although HVPE has shown promising device efficiencies, it lags the OMVPE growth technique in technical maturity. For example, there are no reports of the performance of HVPE-grown devices in radiation environments. There is an expectation that high-quality (that is, single crystal and low-defect) III-V materials will behave similarly regardless of the growth method. However, it is important to verify assumptions as facts. In this project, we produced materials and devices using both HVPE and OMVPE at NREL and irradiated them using 1 MeV electrons to ascertain the effect of radiation on the materials. We also performed initial work on producing more radiation-hard structures, including devices with the pn junction at the front of the device, and devices with a graded doping profile, both of which help with radiation tolerance. Measurements of the devices post radiation exposure showed that the open-circuit voltage (V OC ) of the HVPE-grown solar cells degraded least on a percent basis, although they also started from a lower baseline than the OMVPE-grown devices. All solar cells reached approximately the same V OC after irradiation, indicating that the dose used was sufficient to degrade all device equally. The short-circuit current in the HVPE devices did degrade more than the other solar cells, and this was attributed to a higher-than-expected doping density in the base layer of that cell. The results of these experiments, while by no means comprehensive, do not show any material difference in the radiation effects in OMVPE- and HVPE-grown materials and devices.

14 SOLAR ENERGY↗

Bifacial all-perovskite tandem solar cells

The efficiency of all-perovskite tandem devices falls far below theoretical efficiency limits, mainly because a widening bandgap fails to increase open-circuit voltage. We report on a bifacial all-perovskite tandem structures with an equivalent efficiency of 29.3% under back-to-front irradiance ratio of 30. This increases energy yield and reduces the required bandgap of a wide-bandgap cell. Open-circuit voltage deficit is therefore minimized, although its performance under only front irradiance is not ideal. The bifacial device needs a sputtered rear transparent electrode, which could reduce photon path length and deteriorate stability of Pb-Sn perovskites. Embedding a light-scattering micrometer-sized particle layer into perovskite to trap light, effectively increases absorptance by 5 to 15% in the infrared region. Using a nonacidic hole transport layer markedly stabilizes the hole-extraction interface by avoiding proton-accelerated formation of iodine. These two strategies together increase efficiency of semitransparent Pb-Sn cells from 15.6 to 19.4%, enabling fabrication of efficient bifacial all-perovskite tandem devices.

14 SOLAR ENERGY↗

A light-modified ferroelectric resistive switching behavior in Ag/BaMoO{sub 4}/FTO device at ambient temperature

BaMoO{sub 4} powder was prepared by a facile hydrothermal synthesis. And the BaMoO{sub 4}/FTO device was fabricated by a spin-coated method, in which the thickness of BaMoO{sub 4} layer is about 20 µm. The bipolar resistive switching effect has been observed in Ag/BaMoO{sub 4}/FTO device. Moreover, the resistive switching effect of the device is greatly improved by white light irradiation. The resistive switching behavior is explained by the polarization reversal that changes the charge distribution and modulates the Schottky barriers. - Graphical abstract: We fabricate a resistive switching device based on Ag/BaMoO{sub 4}/FTO, the device shows superior white-light controlled bipolar resistive switching memristive characteristics. - Highlights: • The BaMoO{sub 4} nanosquares powder was prepared by a hydrothermal synthesis. • The resistive switching of the Ag/BaMoO{sub 4}/FTO device was observed for the first time. • It is shown that the resistive switching is greatly improved under the white light irradiation. • The mechanism of resistive switching is attributed to the ferroelectric polarization reversal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Power Targetry R&D and support for future generation accelerator

A high-power target system is a key beam element to complete future High Energy Physics (HEP) experiments. The target endures high power pulsed beam, leading to high cycle thermal stresses/pressures and thermal shocks. The increased beam power will also create significant challenges such as corrosion and radiation damage that can cause harmful effects on the material and degrade their mechanical and thermal properties during irradiation. This can eventually lead to the failure of the material and drastically reduce the lifetime of targets and beam intercepting devices. Designing a reliable target is already a challenge for MW class facilities today and has led several major accelerator facilities to operate at lower power due to target concerns. With present plans to increase beam power for next generation accelerator facilities in the next decade and the multi-year time-scale to acquire the knowledge on material behavior under such extreme environment, timely R&D of robust high-power targets is critical to fully secure the physics benefits of ambitious accelerator power upgrades. The next generation of high-power targets for future accelerators will use more complex geometries, novel materials, and new concepts allowing better high heat flux cooling methods. Advanced numerical simulations need to be developed to satisfy the physical design requirements of reliable beam-intercepting devices. In parallel, radiation hardened beam instrumentation irradiation methods for high-power targets must be further developed. Additional irradiation facilities are needed since only a few facilities worldwide offer beams for target testing, and the beam provided may not be appropriate for the specific facility or project. Thus, a comprehensive research and development program must be implemented to address the challenges that multi-MW targets face.

Pellemoine, F.↗

Fabricating Graphene Oxide/h-BN Metal Insulator Semiconductor Diodes by Nanosecond Laser Irradiation

To employ graphene’s rapid conduction in 2D devices, a heterostructure with a broad bandgap dielectric that is free of traps is required. Within this paradigm, h-BN is a good candidate because of its graphene-like structure and ultrawide bandgap. We show how to make such a heterostructure by irradiating alternating layers of a-C and a-BN film with a nanosecond excimer laser, melting and zone-refining constituent layers in the process. With Raman spectroscopy and ToF-SIMS analyses, we demonstrate this localized zone-refining into phase-pure h-BN and rGO films with distinct Raman vibrational modes and SIMS profile flattening after laser irradiation. Furthermore, in comparing laser-irradiated rGO-Si MS and rGO/h-BN/Si MIS diodes, the MIS diodes exhibit an increased turn-on voltage (4.4 V) and low leakage current. The MIS diode I-V characteristics reveal direct tunneling conduction under low bias and Fowler-Nordheim tunneling in the high-voltage regime, turning the MIS diode ON with improved rectification and current flow. This study sheds light on the nonequilibrium approaches to engineering h-BN and graphene heterostructures for ultrathin field effect transistor device development.

2D materials↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

60 APPLIED LIFE SCIENCES↗

Measurement of Fission Gas Release from Irradiated Fuel During Temperature Transients (Progress Report)

A device for real-time fuel heating observations and collection of fission gas release data is being developed to study nuclear fuel behavior during a temperature transient. The proposed system incorporates high heating and cooling rates, a digital violet laser microscope, mass spectrometry, and gamma ray spectrometry. By placing the system in a hot cell or in a hot cell–like enclosure, the capability could support study of a range of samples, including low and high burnup nuclear fuels. This report documents a conceptional design that incorporates a commercially available system that can be modified to achieve the desired specifications and proposed modifications. This report has been submitted in fulfillment of milestone M3FT-19OR020204082 titled, “Progress Report on Measurement of Fission Gas Release from Irradiated Fuel during Temperature Transient,” for the US Department of Energy Office of Nuclear Energy, Advanced Fuel Campaign of the Fuel Cycle R&D program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗