Coherent optical imaging of moving objects hidden in a heavily scattering random medium

Experimental results are presented that provide insight into the physics of statistical imaging in heavily scattering random media based on measured speckle correlations as a function of the change in position of a moving object. In this way, definitive interpretation of a rather complex and earlier theory is achieved, making this work an experimental complement to that theory paper []. Motion could be natural, where the set of positions is estimated or separately obtained, or directed, where a mechanical stage can be used to adjust the object's position. In the experiment, a coherent laser illuminates two scattering diffusers, while an object is translated between them in the resulting speckled field and images are collected in a transmission configuration. Results are shown for various objects of differing size and geometry, allowing the theory to be validated and interpreted with new understanding. This work demonstrates imaging opportunities, and applications include material characterization, environmental imaging and sensing, and deep-tissue imaging. Published by the American Physical Society 2025

Hastings, Ryan L. (ORCID:0009000095977807)↗

In Situ 4D‐STEM Imaging of the Orientation of Lamellar Clusters in Polymer Crystallization

In semi‐crystalline polymeric materials, the initial stages of nucleation and the growth path of crystalline domains can determine the final performance. Here, in this work, we used four‐dimensional scanning transmission electron microscopy (4D‐STEM) imaging to analyze the changes in lamellar orientation in high‐density polyethylene (HDPE) during heating and cooling. This method allowed us to quantitatively detect the formation of lamellae clusters with different in‐plane orientations, which are not visible with traditional methods. Our analysis provided detailed insights into the orientation and size changes of crystalline domains. Additionally, this technique enabled direct observation of lattice structures in hierarchical lamellae and the growth of crystals, confirming the local variability in lamellar orientation. This innovative approach significantly improves our understanding of polymer crystallization, linking changes in morphology and lattice structures at different length scales.

4D-STEM↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Pushing the limits of high-resolution polymer microscopy using antioxidants

High-resolution transmission electron microscopy (HRTEM) has been transformative to the field of polymer science, enabling the direct imaging of molecular structures. Although some materials have remarkable stability under electron beams, most HRTEM studies are limited by the electron dose the sample can handle. Beam damage of conjugated polymers is not yet fully understood, but it has been suggested that the diffusion of secondary reacting species may play a role. As such, we examine the effect of the addition of antioxidants to a series of solution-processable conjugated polymers as an approach to mitigating beam damage. Characterizing the effects of beam damage by calculating critical dose D c values from the decay of electron diffraction peaks shows that beam damage of conjugated polymers in the TEM can be minimized by using antioxidants at room temperature, even if the antioxidant does not alter or incorporate into polymer crystals. As a consequence, the addition of antioxidants pushes the resolution limit of polymer microscopy, enabling imaging of a 3.6Å lattice spacing in poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3"-di(2-octyldodecyl)-2,2';5',2";5",2"-quaterthiophene-5,5"-diyl)] (PffBT4T-2OD).

36 MATERIALS SCIENCE↗

Imaging a solvent-swollen polymer gel network by open liquid transmission electron microscopy

Visualizing the network of a solvent-swollen polymer gel remains problematic. To address this challenge, open transmission electron microscopy (TEM) was applied to thin gel films permeated by a nonvolatile ionic liquid. The targeted physical gels were prepared by cooling concentrated solutions of poly(ethylene glycol) in 1-ethyl-3-methyl imidazolium ethyl sulfate [EMIM][EtSO 4 ]. During the cooling, gelation occurred by a frustrated crystallization of the dissolved polymer, leading to a percolated, solvent-permeated semicrystalline network in which nanoscale polymer crystals acted as crosslinks. Crystalline features ranging from ~5 to ~200 nm were observed, with the visible network strands dominantly consisting of long curvilinear crystallites of ~15–20 nm diameter. Nascent spherulites irregularly decorated the network, creating a complex structural hierarchy that complicated analyses. Lacking diffraction contrast, TEM did not visualize the many disordered, fully solvated PEG chains present in the voids between crystals. Finally, recognizing that a network's three dimensionality is ambiguous when assessed through two-dimensional microscopy projections, a small gel region was studied by TEM tomography, revealing a nearly isotropic three-dimensional arrangement of the curvilinear crystallites, which displayed remarkably uniform cylindrical cross sections.

36 MATERIALS SCIENCE↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Unsupervised learning of ferroic variants from atomically resolved STEM images

An approach for the analysis of atomically resolved scanning transmission electron microscopy data with multiple ferroic variants in the presence of imaging non-idealities and chemical variabilities based on a rotationally invariant variational autoencoder (rVAE) is presented. We show that an optimal local descriptor for the analysis is a sub-image centered at specific atomic units, since materials and microscope distortions preclude the use of an ideal lattice as a reference point. The applicability of unsupervised clustering and dimensionality reduction methods is explored and is shown to produce clusters dominated by chemical and microscope effects, with a large number of classes required to establish the presence of rotational variants. Comparatively, the rVAE allows extraction of the angle corresponding to the orientation of ferroic variants explicitly, enabling straightforward identification of the ferroic variants as regions with constant or smoothly changing latent variables and sharp orientational changes. This approach allows further exploration of the chemical variability by separating the rotational degrees of freedom via rVAE and searching for remaining variability in the system. The code used in this article is available at https://github.com/saimani5/ferroelectric_domains_rVAE.

30 DIRECT ENERGY CONVERSION↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

Infrared quantum ghost imaging of living and undisturbed plants

Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.

47 OTHER INSTRUMENTATION↗

Statistical analysis of HAADF-STEM images to determine the surface coverage and distribution of immobilized molecular complexes

The surface immobilization of molecular catalysts is attractive because it combines the benefits of homogeneous and heterogeneous catalysis. However, determining the surface coverage and distribution of a molecular catalyst on a solid support is often challenging, inhibiting our ability to design improved catalytic systems. Here, in this work, we demonstrate that the combination of scanning transmission electron microscopy (STEM) and image analysis of the individual positions of heavy atoms in transition metal complexes via a convolutional neural network (CNN) allows statistically robust determination of the surface coverage and distribution of immobilized molecular catalysts. These observations provide information about how changes in the functionalization conditions, attachment group, and structure of the molecular catalyst affect the surface coverage and distribution, providing insight into the chemical mechanism of surface immobilization. The method could be generally valuable for correlating the surface coverage and distribution to the activity, selectivity, and stability of a catalytic system.

HAADF-STEM↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mapping Conductance and Switching Behavior of Graphene Devices In Situ

Graphene is proposed for use in various nanodevice designs, many of which harness emergent quantum properties for device functionality. However, visualization, measurement, and manipulation become nontrivial at nanometer and atomic scales, representing a significant challenge for device fabrication, characterization, and optimization at length scales where quantum effects emerge. Herein, proof of principle results at the crossroads between 2D nanoelectronic devices, e-beam-induced modulation, and imaging with secondary electron e-beam induced currents (SEEBIC) is presented. A device platform compatible with scanning transmission electron microscopy investigations is introduced. Then how the SEEBIC imaging technique can be used to visualize conductance and connectivity in single layer graphene nanodevices, even while supported on a thicker substrate (conditions under which conventional imaging fails) is shown. Finally, it is shown that the SEEBIC imaging technique can detect subtle differences in charge transport through time in nonohmic graphene nanoconstrictions indicating the potential to reveal dynamic electronic processes.

36 MATERIALS SCIENCE↗

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

The role of Ca-bridged organic matter in an alkaline soil, as revealed by multimodal chemical imaging

Mineral–organic matter (OM) studies have predominantly focused on acidic soils that are abundant in iron (Fe) oxides and aluminum (Al) oxides. We have probed mineral–OM interactions in an alkaline or calcareous soil of the Aridisols class. Unlike the role of Fe and Al, the role of Ca-minerals (particularly calcite), which are ubiquitous in alkaline soils, in OM sequestration is not well understood. Multiple recent model studies with aqueous Ca2+ or synthetic calcite and a suite of OM compounds have shown Ca-OM assemblages to be spatially correlated with calcite at the microscale. To study the chemical state of both Ca and Fe and their competing role in soil organic matter (SOM) stabilization, we performed laboratory characterization using x-ray diffraction, Mössbauer spectroscopy, x-ray photoelectron spectroscopy, scanning electron microscopy, and scanning transmission electron microscopy, alongside synchrotron-based microscale chemical imaging using scanning transmission x-ray microscopy combined with near-edge x-ray absorption fine structure. Ca mineral–organic associations were found to be ubiquitous in this system and are likely critical for understanding SOM stabilization/degradation in alkaline soils. From our findings on mineralogy, speciation, and the nature of Ca-OM bridging, we identified differences in C and Ca chemistry based on the relative location of OM to Ca minerals. The OM near the calcite crystal was enriched in lipid and protein moieties, Ca-OM next to Fe minerals displayed a strong contribution from aromatic compounds, while on the surface of microbes, the carbonate was believed to be of microbial in origin, as also suggested by preliminary works reporting on the formation of amorphous calcite or nano-calcite. In Ca-OM admixed with carbonate, it was difficult to distinguish Ca-associated OM from amorphous calcite or nano-calcite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗