Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Mergers at z = 1

Multiband images of nearby interacting pairs of galaxies, mergers, and normal field galaxies are used to simulate images of high redshift mergers by identifying distinctive morphological features. Preliminary results indicate that it is feasible for the HST to detect these high redshift objects.

Kao, Lancelot L.↗

SU-C-209-05: Monte Carlo Model of a Prototype Backscatter X-Ray (BSX) Imager for Projective and Selective Object-Plane Imaging

Purpose: To develop a Monte Carlo N-Particle (MCNP) model for the validation of a prototype backscatter x-ray (BSX) imager, and optimization of BSX technology for medical applications, including selective object-plane imaging. Methods: BSX is an emerging technology that represents an alternative to conventional computed tomography (CT) and projective digital radiography (DR). It employs detectors located on the same side as the incident x-ray source, making use of backscatter and avoiding ring geometry to enclose the imaging object. Current BSX imagers suffer from low spatial resolution. A MCNP model was designed to replicate a BSX prototype used for flaw detection in industrial materials. This prototype consisted of a 1.5mm diameter 60kVp pencil beam surrounded by a ring of four 5.0cm diameter NaI scintillation detectors. The imaging phantom consisted of a 2.9cm thick aluminum plate with five 0.6cm diameter holes drilled halfway. The experimental image was created using a raster scanning motion (in 1.5mm increments). Results: A qualitative comparison between the physical and simulated images showed very good agreement with 1.5mm spatial resolution in plane perpendicular to incident x-ray beam. The MCNP model developed the concept of radiography by selective plane detection (RSPD) for BSX, whereby specific object planes can be imaged by varying kVp. 10keV increments in mean x-ray energy yielded 4mm thick slice resolution in the phantom. Image resolution in the MCNP model can be further increased by increasing the number of detectors, and decreasing raster step size. Conclusion: MCNP modelling was used to validate a prototype BSX imager and introduce the RSPD concept, allowing for selective object-plane imaging. There was very good visual agreement between the experimental and MCNP imaging. Beyond optimizing system parameters for the existing prototype, new geometries can be investigated for volumetric image acquisition in medical applications. This material is based upon work supported under an Integrated University Program Graduate Fellowship sponsored by the Department of Energy Office of Nuclear Energy.

60 APPLIED LIFE SCIENCES↗

Prospective intra-patient evaluation of a shoulder retraction device for radiotherapy in head and neck cancer

Irradiation of tumors in the larynx and pharynx is often technically challenging in patients with a short neck or high shoulders. Shoulder retraction devices can sometimes resolve this problem and allow irradiation via lateral beam directions. This study aimed to measure the proportion of patients who would benefit from such an approach and to quantify the magnitude of the benefit obtained. Twenty patients were studied. Simulator images were obtained before and after intervention. The additional exposure of the cervical spine was measured. Patient comfort and acceptability were assessed with a questionnaire. Improvement of exposure of the cervical spine was observed in 80% of patients. In 20%, there was either no difference or the position was worse. Shoulder retraction exposed a mean of 8.4-10.2 mm more of the cervical spine. Patients in general reported the device as comfortable. The use of a shoulder retraction device produced clinically significant improvements in exposure of the tissues of the cervical spine and neck and should be considered in patients being irradiated for tumors arising in the larynx or hypopharynx.

61 RADIATION PROTECTION AND DOSIMETRY↗

PROBABILISTIC CATALOGS FOR CROWDED STELLAR FIELDS

We present and implement a probabilistic (Bayesian) method for producing catalogs from images of stellar fields. The method is capable of inferring the number of sources N in the image and can also handle the challenges introduced by noise, overlapping sources, and an unknown point-spread function. The luminosity function of the stars can also be inferred, even when the precise luminosity of each star is uncertain, via the use of a hierarchical Bayesian model. The computational feasibility of the method is demonstrated on two simulated images with different numbers of stars. We find that our method successfully recovers the input parameter values along with principled uncertainties even when the field is crowded. We also compare our results with those obtained from the SExtractor software. While the two approaches largely agree about the fluxes of the bright stars, the Bayesian approach provides more accurate inferences about the faint stars and the number of stars, particularly in the crowded case.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving and Assessing the Quality of Uncertainty Quantification in Deep Learning

Deep learning (DL) models have enjoyed increased attention in recent years because of their powerful predictive capabilities. While many successes have been achieved, standard deep learning methods suffer from a lack of uncertainty quantification (UQ). While the development of methods for producing UQ from DL models is an active area of current research, little attention has been given to the quality of the UQ produced by such methods. In order to deploy DL models to high-consequence applications, high-quality UQ is necessary. This report details the research and development conducted as part of a Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. The focus of this project is to develop a framework of methods and metrics for the principled assessment of UQ quality in DL models. This report presents an overview of UQ quality assessment in traditional statistical modeling and describes why this approach is difficult to apply in DL contexts. An assessment on relatively simple simulated data is presented to demonstrate that UQ quality can differ greatly between DL models trained on the same data. A method for simulating image data that can then be used for UQ quality assessment is described. A general method for simulating realistic data for the purpose of assessing a model’s UQ quality is also presented. A Bayesian uncertainty framework for understanding uncertainty and existing metrics is described. Research that came out of collaborations with two university partners are discussed along with a software toolkit that is currently being developed to implement the UQ quality assessment framework as well as serve as a general guide to incorporating UQ into DL applications.

97 MATHEMATICS AND COMPUTING↗

Coupling sky images with radiative transfer models: a new method to estimate cloud optical depth

A method for retrieving cloud optical depth ( τ c ) using a UCSD developed ground-based sky imager (USI) is presented. The radiance red–blue ratio (RRBR) method is motivated from the analysis of simulated images of various τ c produced by a radiative transfer model (RTM). From these images the basic parameters affecting the radiance and red–blue ratio (RBR) of a pixel are identified as the solar zenith angle ( θ 0 ), τ c , solar pixel angle/scattering angle ( θ s ), and pixel zenith angle/view angle ( θ z ). The effects of these parameters are described and the functions for radiance, I λ τ c , θ 0 , θ s , θ z , and RBR τ c , θ 0 , θ s , θ z are retrieved from the RTM results. RBR, which is commonly used for cloud detection in sky images, provides non-unique solutions for τ c , where RBR increases with τ c up to about τ c = 1 (depending on other parameters) and then decreases. Therefore, the RRBR algorithm uses the measured I λ meas θ s , θ z , in addition to RBR meas θ s , θ z , to obtain a unique solution for τ c . The RRBR method is applied to images of liquid water clouds taken by a USI at the Oklahoma Atmospheric Radiation Measurement (ARM) program site over the course of 220 days and compared against measurements from a microwave radiometer (MWR) and output from the Min et al. (2003) method for overcast skies. τ c values ranged from 0 to 80 with values over 80, being capped and registered as 80. A τ c RMSE of 2.5 between the Min et al. (2003) method and the USI are observed. The MWR and USI have an RMSE of 2.2, which is well within the uncertainty of the MWR. In conclusion, the procedure developed here provides a foundation to test and develop other cloud detection algorithms.

54 ENVIRONMENTAL SCIENCES↗

Early Clinical Experience With Kilovoltage Image-Guided Radiation Therapy for Interfraction Motion Management

Interest in image-guided radiation therapy (IGRT) reflects the desire to minimize interfraction positioning variability. Using a kilovoltage (kV) imaging unit mounted to a traditional LINAC allows daily matching of kV images to planning digitally reconstructed radiographs (DRRs). We quantify and evaluate the significance of calculated deviation from the intended isocenter. Since September 2004, 117 patients with various malignancies were treated using the On-Board Imaging (OBI) system, with 2088 treatment sessions. Patients were positioned by the treating therapist; orthogonal images were then obtained with the OBI unit. Couch shifts were made, aligning bony anatomy to the initial simulation image. Routine port films were performed weekly (after that day's OBI session). Ninety percent of all lateral, longitudinal, and vertical shifts were less than 0.8 cm, 0.6 cm, and 0.7 cm, respectively. The median vector shift for each anatomic site was: 0.42 cm for head and neck, 0.40 cm for CNS, 0.59 cm for GU/prostate, and 0.73 cm for breast; shift magnitude did not change with successive OBI sessions. The use of OBI effectively corrects setup variability. These shifts are typically small and random. The use of OBI likely can replace weekly port films for isocenter verification; however, OBI does not provide field shape verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adjuvant radiation therapy for bladder cancer: A dosimetric comparison of techniques

Trials of adjuvant radiation after cystectomy are under development. There are no studies comparing radiation techniques to inform trial design. This study assesses the effect on bowel and rectal dose of 3 different modalities treating 2 proposed alternative clinical target volumes (CTVs). Contours of the bowel, rectum, CTV-pelvic sidewall (common/internal/external iliac and obturator nodes), and CTV-comprehensive (CTV-pelvic sidewall plus cystectomy bed and presacral regions) were drawn on simulation images of 7 post-cystectomy patients. We optimized 3-dimensional conformal radiation (3-D), intensity-modulated radiation (IMRT), and single-field uniform dose (SFUD) scanning proton plans for each CTV. Mixed models regression was used to compare plans for bowel and rectal volumes exposed to 35% (V{sub 35%}), 65% (V{sub 65%}), and 95% (V{sub 95%}) of the prescribed dose. For any given treatment modality, treating the larger CTV-comprehensive volume compared with treating only the CTV-pelvic sidewall nodes significantly increased rectal dose (V{sub 35%} {sub rectum}, V{sub 65%} {sub rectum}, and V{sub 95%} {sub rectum}; p < 0.001 for all comparisons), but it did not produce significant differences in bowel dose (V{sub 95%} {sub bowel}, V{sub 65%} {sub bowel}, or V{sub 35%} {sub bowel}). The 3-D plans, compared with both the IMRT and the SFUD plans, had a significantly greater V{sub 65%} {sub bowel} and V{sub 95%} {sub bowel} for each proposed CTV (p < 0.001 for all comparisons). The effect of treatment modality on rectal dosimetry differed by CTV, but it generally favored the IMRT and the SFUD plans over the 3-D plans. Comparison of the IMRT plan vs the SFUD plan yielded mixed results with no consistent advantage for the SFUD plan over the IMRT plan. Targeting a CTV that spares the cystectomy bed and presacral region may marginally improve rectal toxicity but would not be expected to improve the bowel toxicity associated with any given modality of adjuvant radiation. Using the IMRT or the SFUD plans instead of the 3-D conformal plan may improve both bowel and rectal toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mask roughness induced LER: geometric model at long correlation lengths

Collective understanding of how both the resist and line-edge roughness (LER) on the mask affect the final printed LER has made significant advances. What is poorly understood, however, is the extent to which mask surface roughness couples to image plane LER as a function of illumination conditions, NA, and defocus. Recently, progress has been made in formulating a simplified solution for mask roughness induced LER. Here, we investigate the LER behavior at long correlation lengths of surface roughness on the mask. We find that for correlation lengths greater than 3/NA in wafer dimensions and CDs greater than approximately 0.75/NA, the previously described simplified model, which remains based on physical optics, converges to a 'geometric regime' which is based on ray optics and is independent of partial coherence. In this 'geometric regime', the LER is proportional to the mask slope error as it propagates through focus, and provides a faster alternative to calculating LER in contrast to either full 2D aerial image simulation modeling or the newly proposed physical optics model. Data is presented for both an NA = 0.32 and an NA = 0.5 imaging system for CDs of 22-nm and 50-nm horizontal-line-dense structures.

36 MATERIALS SCIENCE↗

Mitigating imaging systematics for DESI 2024 emission Line Galaxies and beyond

Emission Line Galaxies (ELGs) are one of the main tracers that the Dark Energy Spectroscopic Instrument (DESI) uses to probe the universe. However, they are afflicted by strong spurious correlations between target density and observing conditions known as imaging systematics. In this paper, we present the imaging systematics mitigation applied to the DESI Data Release 1 (DR1) large-scale structure catalogs used in the DESI 2024 cosmological analyses. We also explore extensions of the fiducial treatment. This includes a combined approach, through forward image simulations (Obiwan) in conjunction with neural network-based regression, to obtain an angular selection function that mitigates the imaging systematics observed in the DESI DR1 ELGs target density. We further derive a line of sight selection function from the forward model that removes the strong redshift dependence between imaging systematics and low redshift ELGs. Combining both angular and redshift-dependent systematics, we construct a three-dimensional selection function and assess the impact of all selection functions on clustering statistics. We quantify differences between these extended treatments and the fiducial treatment in terms of the measured 2-point statistics. We find that the results are generally consistent with the fiducial treatment and conclude that the differences are far less than the imaging systematics uncertainty included in DESI 2024 full-shape measurements. We extend our investigation to the ELGs at 0.6 < z < 0.8, i.e., beyond the redshift range (0.8 < z < 1.6) adopted for the DESI clustering catalog, and demonstrate that determining the full three-dimensional selection function is necessary in this redshift range. Our tests showed that all changes are consistent with statistical noise for BAO analyses indicating they are robust to even severe imaging systematics. Specific tests for the full-shape analysis will be presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Dislocations With Edge Components in Nanocrystalline bcc Mo

We report high-resolution transmission electron microscopy (HRTEM) observation of a high density of dislocations with edge components (approximately 1016 m-2) in nanocrystalline (NC) body-centered cubic (bcc) Mo prepared by high-pressure torsion. We also observed for the first time of the 1/2 <111> and <001> pure edge dislocations in NC Mo. Crystallographic analysis and image simulations reveal that the best way using HRTEM to study dislocations with edge components in bcc systems is to take images along <110> zone axis, from which it is possible to identify 1/2 <111> pure edge dislocations, and edge components of 1/2 <111> and <001> mixed dislocations. The <001> pure edge dislocations can only be identified from <100> zone axis. The high density of dislocations with edge components is believed to play a major role in the reduction of strain rate sensitivity in NC bcc metals and alloys.

99 GENERAL AND MISCELLANEOUS↗

Fluence field optimization for noise and dose objectives in CT

Purpose: Selecting the appropriate imaging technique in computed tomography (CT) inherently involves balancing the tradeoff between image quality and imaging dose. Modulation of the x-ray fluence field, laterally across the beam, and independently for each projection, may potentially meet user-prescribed, regional image quality objectives, while reducing radiation to the patient. The proposed approach, called fluence field modulated CT (FFMCT), parallels the approach commonly used in intensity-modulated radiation therapy (IMRT), except ''image quality plans'' replace the ''dose plans'' of IMRT. This work studies the potential noise and dose benefits of FFMCT via objective driven optimization of fluence fields. Methods: Experiments were carried out in simulation. Image quality plans were defined by specifying signal-to-noise ratio (SNR) criteria for regions of interest (ROIs) in simulated cylindrical and oblong water phantoms, and an anthropomorphic phantom with bone, air, and water equivalent regions. X-ray fluence field patterns were generated using a simulated annealing optimization method that attempts to achieve the spatially-dependent prescribed SNR criteria in the phantoms while limiting dose (to the volume or subvolumes). The resulting SNR and dose distributions were analyzed and compared to results using a bowtie filtered fluence field. Results: Compared to using a fixed bowtie filtered fluence, FFMCT achieved superior agreement with the target image quality objectives, and resulted in integral dose reductions ranging from 39 to 52%. Prioritizing dose constraints for specific regions of interest resulted in a preferential reduction of dose to those regions with some tradeoff in SNR, particularly where the target low dose regions overlapped with regions where high SNR was prescribed. The method appeared fairly robust under increased complexity and heterogeneity of the object structure. Conclusions: These results support that FFMCT has the potential to meet prescribed image quality objectives, while decreasing radiation exposure to the patient. Tradeoffs between SNR and dose may not be eliminated, but might be more efficiently managed using FFMCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A gridding approach to detect patterns of change in coastal wetlands from digital data

The conversion of land to water or water to land in the Grand Bayou wetlands area from 1972 to 1981 is evaluated on the basis of Landsat MSS band 2 and 4 images. A postclassification (land vs water) procedure is employed, and grids 1, 5, 10, 25, and 50 pixels square are superimposed on the classified data in an effort to reduce the effects of poor georegistration of the images (simulated by shifting one set of grids two pixels vertically and horizontally). The results are presented in tables, maps, and sample images and characterized in detail. Grids 5 or 10 pixels square are found to give percentage land/water change values and locations similar to those obtained in pixel-by-pixel analysis of nearly perfectly matched images.

Pelletier, R. E.↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a fast-neutron tomographic imaging system developed at Oak Ridge National Laboratory. The system uses an associated particle DT (deuterium-tritium) neutron generator as the source and 25 mm × 25 mm × 100 mm plastic scintillators as the neutron detectors. Two image quality indicators were examined: 1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder and 2) a variety of short steels pins embedded radially in the surface of a shielded polyethylene cylinder. Measurements demonstrated detectability down to approximately 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution and small feature detection limit. The current DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor in the current system configuration.

Wright, Michael C.↗

MERGING GALAXY CLUSTERS: OFFSET BETWEEN THE SUNYAEV-ZEL'DOVICH EFFECT AND X-RAY PEAKS

Galaxy clusters, the most massive collapsed structures, have been routinely used to determine cosmological parameters. When using clusters for cosmology, the crucial assumption is that they are relaxed. However, subarcminute resolution Sunyaev-Zel'dovich (SZ) effect images compared with high-resolution X-ray images of some clusters show significant offsets between the two peaks. We have carried out self-consistent N-body/hydrodynamical simulations of merging galaxy clusters using FLASH to study these offsets quantitatively. We have found that significant displacements result between the SZ and X-ray peaks for large relative velocities for all masses used in our simulations as long as the impact parameters were about 100-250 kpc. Our results suggest that the SZ peak coincides with the peak in the pressure times the line-of-sight characteristic length and not the pressure maximum (as it would for clusters in equilibrium). The peak in the X-ray emission, as expected, coincides with the density maximum of the main cluster. As a consequence, the morphology of the SZ signal, and therefore the offset between the SZ and X-ray peaks, change with viewing angle. As an application, we compare the morphologies of our simulated images to observed SZ and X-ray images and mass surface densities derived from weak-lensing observations of the merging galaxy cluster CL0152-1357, we find that a large relative velocity of 4800 km s{sup -1} is necessary to explain the observations. We conclude that an analysis of the morphologies of multi-frequency observations of merging clusters can be used to put meaningful constraints on the initial parameters of the progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate MTF measurement in digital radiography using noise response

Purpose: The authors describe a new technique to determine the system presampled modulation transfer function (MTF) in digital radiography using only the detector noise response. Methods: A cascaded-linear systems analysis was used to develop an exact relationship between the two-dimensional noise power spectrum (NPS) and the presampled MTF for a generalized detector system. This relationship was then utilized to determine the two-dimensional presampled MTF. For simplicity, aliasing of the correlated noise component of the NPS was assumed to be negligible. Accuracy of this method was investigated using simulated images from a simple detector model in which the ''true'' MTF was known exactly. Measurements were also performed on three detector technologies (an x-ray image intensifier, an indirect flat panel detector, and a solid state x-ray image intensifier), and the results were compared using the standard edge-response method. Flat-field and edge images were acquired and analyzed according to guidelines set forth by the International Electrotechnical Commission, using the RQA 5 spectrum. Results: The presampled MTF determined using the noise-response method for the simulated detector system was in close agreement with the true MTF with an averaged percent difference of 0.3% and a maximum difference of 1.1% observed at the Nyquist frequency (f{sub N}). The edge-response method of the simulated detector system also showed very good agreement at lower spatial frequencies (less than 0.5 f{sub N}) with an averaged percent difference of 1.6% but showed significant discrepancies at higher spatial frequencies (greater than 0.5 f{sub N}) with an averaged percent difference of 17%. Discrepancies were in part a result of noise in the edge image and phasing errors. For all three detector systems, the MTFs obtained using the two methods were found to be in good agreement at spatial frequencies less than 0.5 f{sub N} with an averaged percent difference of 3.4%. Above 0.5 f{sub N}, differences increased to an average of 20%. Deviations of the experimental results largely followed the trend seen in the simulation results, suggesting that differences between the two methods could be explained as resulting from the inherent inaccuracies of the edge-response measurement technique used in this study. Aliasing of the correlated noise component was shown to have a minimal effect on the measured MTF for the three detectors studied. Systems with significant aliasing of the correlated noise component (e.g., a-Se based detectors) would likely require a more sophisticated fitting scheme to provide accurate results. Conclusions: Results indicate that the noise-response method, a simple technique, can be used to accurately measure the MTF of digital x-ray detectors, while alleviating the problems and inaccuracies associated with use of precision test objects, such as a slit or an edge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated refraction-enhanced X-ray radiography of laser-driven shocks

Refraction-enhanced x-ray radiography (REXR) is used to infer shock-wave positions of more than one shock wave, launched by a multiple-picket pulse in a planar plastic foil. This includes locating shock waves before the shocks merge, during the early time and the main drive of the laser pulse that is not possible with the velocity interferometer system for any reflector. Simulations presented in this paper of REXR show that it is necessary to incorporate refraction and attenuation of x rays along with the appropriate opacity and refractive-index tables to interpret experimental images. Simulated REXR shows good agreement with an experiment done on the OMEGA laser facility to image a shock wave. REXR can be applied to design multiple-picket pulses with a better understanding of the shock locations. Finally, this will be beneficial to obtain the required adiabats for inertial confinement fusion implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-JeP3-07: Real-Time Image Guided Radiation Therapy for Heterotopic Ossification in Patients After Hip Replacement

Purpose: To demonstrate the feasibility of using CBCT in a real-time image guided radiation therapy (IGRT) for single fraction heterotopic ossification (HO) in patients after hip replacement. In this real-time procedure, all steps, from simulation, imaging, planning to treatment delivery, are performed at the treatment unit in one appointment time slot. This work promotes real-time treatment to create a paradigm shift in the single fraction radiation therapy. Methods: An integrated real-time IGRT for HO was developed and tested for radiation treatment of heterotopic ossification for patient after hip replacement. After CBCT images are acquired at the linac, and sent to the treatment planning system, the physician determines the field and/or draws a block. Subsequently, a simple 2D AP/PA plan with prescription of 700 cGy is created on-the-fly for physician to review. Once the physician approves the plan, the patient is treated on the same simulation position. This real-time treatment requires the team of attending physician, physicist, therapists, and dosimetrist to work in harmony to achieve all the steps in a timely manner. Results: Ten patients have been treated with this real-time treatment, having the same beams arrangement treatment plan and prescription as our clinically regular CT-based 2D plans. The average time for these procedures are 52.9 ±10.7 minutes from the time patient entered the treatment room until s/he exited, and 37.7 ±8.6 minutes from starting CBCT until last beam delivered. Conclusion: The real-time IGRT for HO treatment has been tested and implemented to be a clinically accepted procedure. This one-time appointment greatly enhances the waiting time, especially when patients in high level of pain, and provides a convenient approach for the whole clinical staff. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗