Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Investigation of laser dynamics, modulation and control by means of intra-cavity time varying perturbation

Projects aimed at the generation of tunable visible, infrared, and ultraviolet light, and on the control of this light by means of novel mode-locking and modulation techniques are discussed. During this period the following projects have been active: (1) studies of transient mode-locking of the Nd:YAG laser and the application of short optical pulses; (2) experimental investigations of the Na-Xe excimer laser system; (3) further development of techniques for vacuum ultraviolet holography; and (4) theoretical and initial experimental studies of a new device which should prove very useful for both infrared up-conversion and generation of tunable UV radiation - a two-photon resonantly pumped frequency converter.

Harris, S. E.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo- loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied .

Snell, Eddie H.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryo-crystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we present used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, E. H.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

We have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. Cryocooling is a common technique used for structural data collection to reduce radiation damage in intense X-ray beams and decrease the thermal motion of the atoms. From the thermal images it was clear that during cryocooling a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop for automated structural genomics studies. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryocooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, Eddie↗

Stray radiation and the Infrared Astronomical Satellite /IRAS/ telescope

Stray light control is a major consideration in the design of infrared cryogenically cooled telescopes such as the Infrared Astronomical Satellite (IRAS). The basic design of the baffle system, and the placement, shape, and coating of the secondary support struts for the telescope subsystem are described. The intent of this paper is to highlight the stray light problems encountered while designing the system, and to illustrate how computer analysis can be a useful design aid. Scattering measurements of the primary mirror, and a full system level scatter measurement are presented. Comparisons of predicted performance with the measured results are also presented.

Noll, R. J.↗

Using XML and Java Technologies for Astronomical Instrument Control

Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center, under the Instrument Remote Control (IRC) project, is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is that the software is driven by an instrument description, written using the Instrument Markup Language (IML), a dialect of XML. IML is used to describe the command sets and command formats of the instrument, communication mechanisms, format of the data coming from the instrument, and characteristics of the graphical user interface to control and monitor the instrument. The IRC framework allows the users to define a data analysis pipeline which converts data coming out of the instrument. The data can be used in visualizations in order for the user to assess the data in real-time, if necessary. The data analysis pipeline algorithms can be supplied by the user in a variety of forms or programming languages. Although the current integration effort is targeted for the High-resolution Airborne Wideband Camera (HAWC) and the Submillimeter and Far Infrared Experiment (SAFIRE), first-light instruments of the Stratospheric Observatory for Infrared Astronomy (SOFIA), the framework is designed to be generic and extensible so that it can be applied to any instrument. Plans are underway to test the framework with other types of instruments, such as remote sensing earth science instruments.

Ames, Troy↗

Instrument for Measuring Temperature of Water

A pseudo-Brewster-angle infrared radiometer has been proposed for use in noncontact measurement of the surface temperature of a large body of water (e.g., a lake or ocean). This radiometer could be situated on a waterborne, airborne, or spaceborne platform. The design of the pseudo-Brewster-angle radiometer would exploit the spectral-emissivity and polarization characteristics of water to minimize errors attributable to the emissivity of water and to the reflection of downwelling (e.g., Solar and cloud-reflected) infrared radiation. The relevant emissivity and polarization characteristics are the following: . The Brewster angle is the angle at which light polarized parallel to the plane of incidence on a purely dielectric material is not reflected. The pseudo-Brewster angle, defined for a lossy dielectric (somewhat electrically conductive) material, is the angle for which the reflectivity for parallel-polarized light is minimized. For pure water, the reflectivity for parallel-polarized light is only 2.2 x 10(exp -4) at its pseudo- Brewster angle of 51deg. The reflectivity remains near zero, several degrees off from the 51deg optimum, allowing this angle of incidence requirement to be easily achieved. . The wavelength range of interest for measuring water temperatures is 8 to 12 microns. The emissivity of water for parallel- polarized light at the pseudo-Brewster angle is greater than 0.999 in this wavelength range. The radiometer would be sensitive in the wavelength range of 8 to 12 microns, would be equipped with a polarizer to discriminate against infrared light polarized perpendicular to the plane of incidence, and would be aimed toward a body of water at the pseudo- Brewster angle (see figure). Because the infrared radiation entering the radiometer would be polarized parallel to the plane of incidence and because very little downwelling parallel-polarized radiation would be reflected into the radiometer on account of the pseudo-Brewster arrangement, the radiation received by the radiometer would consist almost entirely of thermal emission from the surface of the water. Because the emissivity of the water would be very close to 1, the water could be regarded as a close approximation of a blackbody for the purpose of computing its surface temperature from the radiometer measurements by use of the Planck radiation law.

Ryan, Robert↗

Floquet–Bloch manipulation of the Dirac gap in a topological antiferromagnet

Floquet–Bloch manipulation, achieved by driving a material periodically with a laser pulse, is a method that enables the engineering of electronic and magnetic phases in solids by effectively modifying the structure of their electronic bands. However, the application of Floquet–Bloch manipulation in topological magnetic systems, particularly those with inherent disorder, remains largely unexplored. Here, in this study, we realize Floquet–Bloch manipulation of the Dirac surface-state mass of the topological antiferromagnet MnBi 2 Te 4 . Using time- and angle-resolved photoemission spectroscopy, we show that opposite helicities of mid-infrared circularly polarized light result in substantially different Dirac mass gaps in the antiferromagnetic phase, despite the equilibrium Dirac cone being massless. We explain our findings in terms of a Dirac fermion with a random mass. Our results underscore Floquet–Bloch manipulation as a powerful tool for controlling topology, even in the presence of disorder, and for uncovering properties of materials that may elude conventional probes.

42 ENGINEERING↗

Lunar thermal environment

Quantitative data on photometric, luminescence, light polarization, color, infrared temperature, and microwave temperature properties of moon

THERMAL ENVIRONMENT↗

Investigation of laser dynamics, modulation and control by means of intra-cavity time varying perturbation

Work continued on a number of projects aimed at the generation of tunable visible, infrared, and ultraviolet light; and on the control of this light by means of novel mode-locking and modulation techniques. Progress is summarized for the following projects: (1) the transient modelocking of the Nd:YAG laser and application of short optical pulses; (2) studies of the sodium-xenon excimer laser; (3) development of techniques for vacuum ultraviolet holography; and (4) studies of multiple photon pumped xenon and argon excimer lasers.

Harris, S. E.↗

Investigation of laser dynamics, modulation and control by means of intra-cavity time varying perturbation

The generation of tunable visible, infrared, and ultraviolet light is examined, along with the control of this light by means of novel mode-locking and modulation techniques. Transient mode-locking of the Nd:YAG laser and generation of short tunable pulses in the visible and the alkali metal inert gas excimer laser systems were investigated. Techniques for frequency conversion of high power and high energy laser radiation are discussed, along with high average power blue and UV laser light sources.

Harris, S. E.↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Studies of laser and laser devices

The generation of tunable, infrared, and ultraviolet light, and the control of this light by mode-locking and modulation techniques are discussed. Particular emphasis is given to energy storage and extraction using atomic levels, the development of a tunable narrowband vacuum ultraviolet light source, and to the generation and applications of ultrashort optical pulses.

Harris, S. E.↗

Progress of research on water vapor lidar

Research is summarized on applications of stimulated Raman scattering (SRS) of laser light into near infrared wavelengths suitable for atmospheric monitoring. Issues addressed are conversion efficiency, spectral purity, optimization of operating conditions, and amplification techniques. A Raman cell was developed and built for the laboratory program, and is now available to NASA-Langley, either as a design or as a completed cell for laboratory or flight applications. The Raman cell has been approved for flight in NASA's DC-8 aircraft. The self-seeding SRS technique developed here is suggested as an essential improvement for tunable near-IR DIAL applications at wavelengths of order 1 micrometer or greater.

Wilkerson, Thomas D.↗

Theory of CW lidar aerosol backscatter measurements and development of a 2.1 microns solid-state pulsed laser radar for aerosol backscatter profiling

The performance and calibration of a focused, continuous wave, coherent detection CO2 lidar operated for the measurement of atmospheric backscatter coefficient, B(m), was examined. This instrument functions by transmitting infrared (10 micron) light into the atmosphere and collecting the light which is scattered in the rearward direction. Two distinct modes of operation were considered. In volume mode, the scattered light energy from many aerosols is detected simultaneously, whereas in the single particle mode (SPM), the scattered light energy from a single aerosol is detected. The analysis considered possible sources of error for each of these two cases, and also considered the conditions where each technique would have superior performance. The analysis showed that, within reasonable assumptions, the value of B(m) could be accurately measured by either the VM or the SPM method. The understanding of the theory developed during the analysis was also applied to a pulsed CO2 lidar. Preliminary results of field testing of a solid state 2 micron lidar using a CW oscillator is included.

Kavaya, Michael J.↗

Velocity resolved spectroscopy of molecular hydrogen emission in NGC6240

NGC6240 is a member of the class of luminous galaxies which emit a significant fraction of their total light in the infrared. Based on its highly disturbed morphology, Fosbury and Wall (1979) suggested that the system may be a merger of two gas rich galaxies. It has two nuclei separated by 2 arcsec which are visible in the near infrared and at radio wavelengths and CO observations show that the galaxy contains a large mass of molecular gas. Unusually strong H2 emission lines dominate the near infrared spectrum of this galaxy. The galaxy emits approximately 4x10(exp 7) solar luminosity in the 2.12 micron v = 1 to 0 S(1) line alone, an order of magnitude more than other merging or starburst galaxies. To provide a better understanding of the physical processes responsible for the H2 emission from NGC6240 we have begun a program to obtain high spectral resolution observations using the echelle in CGS4 on the UKIRT. Preliminary data which were obtained in February 1991 are presented here. It is intended to obtain further observations with twice the spatial and spectral resolution in June of this year.

Wright, G. S.↗

Probing the optical depth of spiral galaxies using multi-waveband observations

The questions of the optical depth and extinction of galaxies obviously have far-reaching implications; from determining the true stellar content and baryonic mass of galaxies to the origin of the major component of their far infrared radiation. We have investigated whether the reddening of stars can be used to determine the amount and extent of obscuring dust. We find that the amount of reddening is very sensitive to the assumed geometry. The usually assumed case of a screen of dust between the observer and the star produces, for a given optical depth, the maximum amount of reddening. However, for external galaxies such a geometry is clearly wrong. More realistic geometries where the dust and stars are uniformly mixed (a 'slab') or where the dust is sandwiched by unobscured stars (a 'sandwich') produce significantly less reddening. For the slab geometry of the reddening rises to a maximum value as the optical depth is increased, and for a sandwich geometry the reddening will actually decrease as the optical depth becomes larger. The reddening vectors produced by these realistic geometries are compared to multi-waveband observations of individual regions of a sample of eight galaxies. We find evidence for significant optical depths in the central regions of some of these galaxies, but optical depths of less than unity at approx. 2 scale lengths from the centers. The optical depths derived are in good agreement with other tests such as the measured hydrogen column densities and the far infrared to blue light ratios. However, whereas these two latter approaches are insensitive to the relative distributions of the stars and the dust, the amount of reddening seen in these eight galaxies suggests that the dust to stellar scale height ratio xi is greater than or equal to 0.5. We find typical blue band extinctions of A(sub B) = 0.75-1.0, a factor of 3-4 higher than the RC2 value.

Evans, Rhodri↗