Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Implications of asymmetric beam geometry for convergent acoustic Doppler profilers

The focus of this research is to develop a measurement instrument to characterize complex flows at spatial and temporal resolutions pertinent to understanding hydrodynamic loads in zones of fluid-structure interaction. Foundational work has demonstrated that flow velocities can be measured at a fixed focal point using a convergent array of acoustic Doppler profiling (C-ADP) instruments. As an extension of this concept, the following approach describes an application of the technology to facilitate 3D velocity measurements at a dynamically adjustable focal point location. Furthermore, the ability to dynamically control the focal point location in real-time allows the instrument to survey velocities within a three-dimensional velocity field. The resulting configuration targets a combination of measurement fidelity and control that has not been achieved by existing remote flow measurement instrumentation in the marine environment.

Harding, Samuel F.↗

On the Development of Compact HTS Coil Modules for Large Bore High Field Superconducting Magnets

Lower cost, high current density superconducting coil modules producing higher magnetic fields and cooled affordably are crucial for obtaining cost-effective, compact commercial fusion reactors. Accessibility to low cost, higher field magnets (>30 T) is also critical for the discovery of new quantum phenomena in materials, cosmic frontier and other topics in basic science research. The Princeton Plasma Physics Laboratory (PPPL) is working with Princeton University to develop unique large bore, compact superconducting magnets to support science experiments including the development of new instrumentation for condensed matter physics and Axion dark matter search in the cosmic frontier. Core elements of these experiments are unique for access to lower cost, simple fabrication of compact superconducting magnets that can be cooled affordably, while integrated with dedicated science instruments. Conductor qualification and coil design concepts are discussed in support of needs for these experiments. PPPL has the unique expertise and experimental facilities to design, construct and test subscale coil modules for these projects. Compact high field coil modules were fabricated and tested to validate coil design concepts and coil performance. Finally, the design and model coil integration challenges are discussed to identify performance risks and demonstrate feasibility for deploying full scale large bore compact superconducting magnets for cost effective operations of multiple laboratory experiments.

axion dark matter↗

Scanning Probe Microscopy in the Information Age

Scanning probe microscopy (SPM) has brought scientific exploration, visualization, and control to nanoscale. A plethora of measurement approaches and techniques devised around SPM enabled probing structure and functionalities crucial for virtually all areas of science. While high-resolution electron microscopy techniques preceded scanning probes, SPM effectively opened the door to probing the structure–property relationship on length scales spanning 100s of micrometers down to a single atom. As the complexity of the material systems and the scientific questions increased, so too did the SPM techniques. Substantial efforts have been dedicated toward the development of better instrumentation platforms, probes, and novel spectroscopic measurements; however, many opportunities related to data processing and acquisition in SPM are just being realized now. This chapter will describe the recent progress in data-driven SPM by giving a broad overview of the field, the foundation of the scanning tunneling microscope (STM) and the atomic force microscope (AFM), as well as a description behind the operating principles and dynamic modes. A comprehensive overview of the multi-frequency techniques, Band excitation, and general acquisition mode SPM is given, setting the context for the application of big data, machine learning, and artificial intelligence in the field of dynamic SPM.

Collins, Liam↗

Benchmarking for AI for Science

AI has been instrumental for recent developments in a number of domains of the sciences. With several hundred machine learning (ML) algorithms and models, and numerous AI-specific hardware platforms, a common quest for all scientists working on AI for Science is around the selection of machine learning algorithm(s) to solve their domain-specific scientific problems. A number of different initiatives around AI Benchmarking have been set up and have been useful in understanding the benefits of different ML algorithms for different tasks.However, with the majority of these AI Benchmarking initiatives focusing on the conventional notions of benchmarking, where the focus is purely runtime performance (such as training time or inference time), their suitability for benchmarking different ML algorithms for solving scientific problems has been viewed as a performance problem even though both are hardly the same. To make reasonable, explainable, and justifiable advancements in science using AI, it is critical to focus on the merits of these algorithms in handling different domain science problems. In other words, more emphasis must be given on Benchmarking for AI for Science than AI Benchmarking. The vision of the former is not only to assess the performance of ML algorithms, but also to assess, and understand the benefits and merits of different ML algorithms in handling scientific problems. Benchmarking for AI for Science, instead of pure performance focused AI Benchmarking, has several benefits: (i) it has the potential to offer advances in the sciences, much more rapidly than through pure performance-based AI methods, (ii) it will encourage the community to focus on developing better domain-specific AI techniques, particularly given the provision for being able to benchmark different techniques, and (iii) it will encourage hardware manufacturers to focus on developing science-specific hardware subsystems.

Thiyagalingam, Jeyan↗

The scientific case for concurrent neutron and X-ray scattering and spectroscopy

The interrogation of materials with X-rays or neutrons to determine structure, energetics, and dynamics is fundamental to advancing physical and chemical materials science and enabling innovative material technologies. A persistent challenge in materials development is that progress depends on understanding structure and dynamics across multiple length and time scales in increasingly complex, multicomponent systems featuring interfaces, heterogeneity, and hierarchical organization. Despite rapidly growing demands on materials characterization, current experimental approaches are almost exclusively based on isolated X-ray or neutron scattering and spectroscopy, reflecting a paradigm largely unchanged for decades. To assess the scientific need for a new experimental paradigm, a 3-day workshop sponsored by the U.S. National Science Foundation (NSF) was held at the SpringHill Suites, San Jose, California, from June 2 to 4, 2022. The workshop brought together 70 national and international experts who critically evaluated opportunities enabled by concurrent neutron and X-ray (NeX) scattering, spectroscopy, and imaging experiments. The participants reached a clear consensus that establishing NeX capabilities is crucial for advancing the science of complex materials in the United States. This report illustrates the scientific drivers for NeX experiments through representative examples spanning biomaterials, energy materials, soft matter, nanomaterials, quantum materials, geoscience, and applied materials research. The complementarity of neutrons and X-rays is essential for robust model development and refinement, particularly in multiphase and multicomponent systems. While joint refinement of data from separate experiments is valuable, concurrent measurements uniquely eliminate uncertainties arising from sample evolution, environmental drift, and irreproducibility associated with experiments performed at different locations and times. Realizing NeX capabilities will require the development of new instrumentation, data analysis frameworks, and robust sample environments compatible with both neutron and X-ray probes. Addressing these challenges will enable unambiguous interpretation of complex materials behavior and open new frontiers in materials research.

X-ray↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Polar primary aerosols across the ocean-sea ice-snow-atmosphere interface: From sources to impacts

Primary aerosols play a critical role in polar climate systems, influencing cloud formation, precipitation, radiative balance, and surface energy budgets. This paper provides a comprehensive synthesis of primary aerosol sources, transformation and removal processes, and broader atmospheric impacts in polar regions, emphasizing their links to ocean and sea ice biogeochemistry. These aerosols (including sea salt, primary organic aerosol, and primary biological aerosol particles) originate from marine and cryospheric environments and are emitted through physical processes, such as wave breaking, bubble bursting, and blowing snow. Emission sources include seawater, sea ice, snow, and freshwater from river discharge and glacial runoff. Once airborne, these particles can serve as a chemical reservoir, influencing atmospheric composition and reactivity, and as seeds for cloud droplet and ice crystal formation, influencing cloud microphysics and polar climate. Despite their importance, many of the processes governing primary aerosol emissions and transformations remain poorly constrained. The most pressing knowledge gaps pertain to emission processes, limited spatiotemporal observational coverage, instrumentation constraints, parameterization development, and the integration of interdisciplinary expertise. To improve our understanding of primary aerosol drivers and their response to climate, future research efforts should prioritize strategically coordinated and cross-disciplinary process studies, advancements in measurement technologies and coverage, and close collaboration between modelers and observational scientists to inform and refine model parameterizations. As polar regions continue to undergo profound changes marked by increased precipitation, reduced sea and land ice, freshening oceans, and shifting ecosystem dynamics, characterizing present-day primary aerosol populations is vital. Improved understanding will be essential for anticipating future changes in aerosol-radiation and aerosol-cloud interactions and their implications for polar and global climate systems.

Aerosol-cloud↗

Materials properties characterization in the most extreme environments

Abstract There is an ever-increasing need for material systems to operate in the most extreme environments encountered in space exploration, energy production, and propulsion systems. To effectively design materials to reliably operate in extreme environments, we need an array of tools to both sustain lab-scale extreme conditions and then probe the materials properties across a variety of length and time scales. Within this article, we examine the state-of-the-art experimental systems for testing materials under extreme environments and highlight the limitations of these approaches. We focus on three areas: (1) extreme temperatures, (2) extreme mechanical testing, and (3) chemically hostile environments. Within these areas, we identify six opportunities for instrument and technique development that are poised to dramatically impact the further understanding and development of next-generation materials for extreme environments. Graphical abstract

Schreiber, Daniel K.↗

Supervisory control and health monitoring framework for large-scale additive manufacturing systems. Final CRADA report

ORNL worked with National Instruments (NI) to develop a large-scale, complex additive manufacturing (AM) systems framework for remote health monitoring and supervisory control. We found the framework, based on the Lincoln Electric Metal AM system located at ORNL’s MDF, capable of controlling the process, leading to improved part quality and digital twin creation.

42 ENGINEERING↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS): CRADA 410 (Final Report)

This document is the final report for CRADA 410 (Project No. 72496). The purpose of this project was supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. PNNL worked with Agilent to evaluate and improve the integration of ion mobility into existing MS data analysis methods of Agilent software tools. The project augmented PNNL’s capabilities to analyze complex omics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

97 MATHEMATICS AND COMPUTING↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Book Chapter: Small Modular Reactors

Small Modular Reactors (SMRs) have been a very promising development in nuclear power over the last two decades. SMRs are defined as nuclear reactors with a power output of less than 300 MWe. This is in comparison to gigawatt-size reactors, which can have electrical output of 1000–1500 MWe or more. This chapter will consist of two major sections. The first will be a detailed summary of the small modular reactor designs being proposed around the world. This section will focus on those that are the furthest along in their development, but will also include some information about the wide variety of proposed designs that require significant research and development. The second part will be a discussion of the remaining challenges to the adoption of SMRs as a major energy source. SMRs are not a new concept, but they do represent a new vision for an older concept. These reactors have the potential to become a major source of energy in the near future. The development of small, modular designs can help promote the adoption of nuclear energy by reducing upfront costs, reducing the financial risk associated with nuclear power, and the barriers to entry. However, the adoption of SMRs is not without challenges. Regulatory and licensing changes to address the unique benefits and concerns associated with SMRs will continue to be a challenge as regulators adapt to the unique features emerging from the design process. The development of new instrumentation and control systems is an ongoing issue. And economics is possibly the most significant challenge, with high construction costs, cheap natural gas, and government subsidies, combining to result in significant financial risk associated with adopting nuclear generation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗