Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integer Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

COOPR: A COmmon Optimization Python Repository v. 1.0

Coopr integrates Python packages for defining optimizers, modeling optimization applications, and managing computational experiments. A major driver for Coopr development is the Pyomo package that can be used to define abstract problems, create concrete problem instances, and solve these instances with standard solvers. Other Coopr packages include EXACT, a framework for managing computational experiments, SUCASA, a tool for customizing integer programming solvers, and OPT, a generic optimization interface.

HART, WILLIAM↗

COOPR: A COmmon Optimization Python Repository v. 1.0

Coopr integrates Python packages for defining optimizers, modeling optimization applications, and managing computational experiments. A major driver for Coopr development is the Pyomo package that can be used to define abstract problems, create concrete problem instances, and solve these instances with standard solvers. Other Coopr packages include EXACT, a framework for managing computational experiments, SUCASA, a tool for customizing integer programming solvers, and OPT, a generic optimization interface.

HART, WILLIAM↗

A two-phase investment model for optimal allocation of phasor measurement units considering transmission switching

Ensuring the reliability of an electrical power system requires a wide-area monitoring and full observability of the state variables. Phasor measurement units (PMUs) collect in real time synchronized phasors of voltages and currents which are used for the observability of the power grid. Due to the considerable cost of installing PMUs, it is not possible to equip all buses with PMUs. In this paper, we propose an integer linear programming model to determine the optimal PMU placement plan in two investment phases. In the first phase, PMUs are installed to achieve full observability of the power grid whereas additional PMUs are installed in the second phase to guarantee the N - 1 observability of the power grid. The proposed model also accounts for transmission switching and single contingencies such as failure of a PMU or a transmission line. Results are provided on several IEEE test systems which show that our proposed approach is a promising enhancement to the methods available for the optimal placement of PMUs.

Phasor measurement unit↗

Optimal response to attacks on the open science grids.

Cybersecurity is a growing concern, especially in open grids, where attack propagation is easy because of prevalent collaborations among thousands of users and hundreds of institutions. The collaboration rules that typically govern large science experiments as well as social networks of scientists span across the institutional security boundaries. A common concern is that the increased openness may allow malicious attackers to spread more readily around the grid. We consider how to optimally respond to attacks in open grid environments. To show how and why attacks spread more readily around the grid, we first discuss how collaborations manifest themselves in the grids and form the collaboration network graph, and how this collaboration network graph affects the security threat levels of grid participants. We present two mixed-integer program (MIP) models to find the optimal response to attacks in open grid environments, and also calculate the threat level associated with each grid participant. Given an attack scenario, our optimal response model aims to minimize the threat levels at unaffected participants while maximizing the uninterrupted scientific production (continuing collaborations). By adopting some of the collaboration rules (e.g., suspending a collaboration or shutting down a site), the model finds optimal response to subvert an attack scenario.

99 GENERAL AND MISCELLANEOUS↗

Model for Collaboration among Carriers to Reduce Empty Container Truck Trips

In recent years, intermodal transport has become an increasingly attractive alternative to freight shippers. However, the current intermodal freight transport is not as efficient as it could be. Oftentimes an empty container needs to be transported from the empty container depot to the shipper, and conversely, an empty container needs to be transported from the receiver to the empty container depot. These empty container movements decrease the freight carrier’s profit, as well as increase traffic congestion, decrease roadway safety, and add unnecessary emissions to the environment. To this end, our study evaluates a potential collaboration strategy to be used by carriers for domestic intermodal freight transport based on an optimization approach to reduce the number of empty container trips. A binary integer-linear programming model is developed to determine each freight carrier’s optimal schedule while minimizing its operating cost. The model ensures that the cost for each carrier with collaboration is less than or equal to its cost without collaboration. It also ensures that average savings from the collaboration are shared equally among all participating carriers. Additionally, two stochastic models are provided to account for uncertainty in truck travel times. The proposed collaboration strategy is tested using empirical data and is demonstrated to be effective in meeting all of the shipment constraints.

42 ENGINEERING↗

Holistic fleet optimization incorporating system design considerations

The methodology described in this article enables a type of holistic fleet optimization that simultaneously considers the composition and activity of a fleet through time as well as the design of individual systems within the fleet. Often, real-world system design optimization and fleet-level acquisition optimization are treated separately due to the prohibitive scale and complexity of each problem. Importantly, this means that fleet-level schedules are typically limited to the inclusion of predefined system configurations and are blind to a rich spectrum of system design alternatives. Similarly, system design optimization often considers a system in isolation from the fleet and is blind to numerous, complex portfolio-level considerations. In reality, these two problems are highly interconnected. To properly address this system-fleet design interdependence, we present a general method for efficiently incorporating multi-objective system design trade-off information into a mixed-integer linear programming (MILP) fleet-level optimization. This work is motivated by the authors' experience with large-scale DOD acquisition portfolios. However, the methodology is general to any application where the fleet-level problem is a MILP and there exists at least one system having a design trade space in which two or more design objectives are parameters in the fleet-level MILP.

97 MATHEMATICS AND COMPUTING↗

Solving the Unit Commitment Problem: Polyhedral Theory, Symmetry, and Power Flow

In this talk, I will give an overview of mixed integer linear programming (MILP) formulations and extensions thereof which enable the effective solution of the unit commitment problem (UC) when paired with a commercial MILP solver. First, we will place UC in context, stressing the importance of achieving a (near) optimal solution. Then we will discuss the importance of perfect and "good-enough" formulations for individual generators / market participants. Some of these formulations enable symmetry-aware reformulations for identical market participants, which can be critical when symmetry is present. Finally, we will discuss approximations of AC power flow currently used in practice, and the challenges with including these approximations within the UC formulation.

MATHEMATICS AND COMPUTING↗

Analysis of Modeling Assumptions used in Production Cost Models for Renewable Integration Studies

Renewable energy integration studies have been published for many different regions exploring the question of how higher penetration of renewable energy will impact the electric grid. These studies each make assumptions about the systems they are analyzing; however the effect of many of these assumptions has not been yet been examined and published. In this paper we analyze the impact of modeling assumptions in renewable integration studies, including the optimization method used (linear or mixed-integer programming) and the temporal resolution of the dispatch stage (hourly or sub-hourly). We analyze each of these assumptions on a large and a small system and determine the impact of each assumption on key metrics including the total production cost, curtailment of renewables, CO2 emissions, and generator starts and ramps. Additionally, we identified the impact on these metrics if a four-hour ahead commitment step is included before the dispatch step and the impact of retiring generators to reduce the degree to which the system is overbuilt. We find that the largest effect of these assumptions is at the unit level on starts and ramps, particularly for the temporal resolution, and saw a smaller impact at the aggregate level on system costs and emissions. For each fossil fuel generator type we measured the average capacity started, average run-time per start, and average number of ramps. Linear programming results saw up to a 20% difference in number of starts and average run time of traditional generators, and up to a 4% difference in the number of ramps, when compared to mixed-integer programming. Utilizing hourly dispatch instead of sub-hourly dispatch saw no difference in coal or gas CC units for either start metric, while gas CT units had a 5% increase in the number of starts and 2% increase in the average on-time per start. The number of ramps decreased up to 44%. The smallest effect seen was on the CO2 emissions and total production cost, with a 0.8% and 0.9% reduction respectively when using linear programming compared to mixed-integer programming and 0.07% and 0.6% reduction, respectively, in the hourly dispatch compared to sub-hourly dispatch.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Location of Radiation Therapy Centers With Respect to Geographic Access

Purpose: To develop a framework with which to evaluate locations of radiation therapy (RT) centers in a region based on geographic access. Methods and Materials: Patient records were obtained for all external beam radiation therapy started in 2011 for the province of British Columbia, Canada. Two metrics of geographic access were defined. The primary analysis was percentage of patients (coverage) within a 90-minute drive from an RT center (C90), and the secondary analysis was the average drive time (ADT) to an RT center. An integer programming model was developed to determine optimal center locations, catchment areas, and capacity required under different scenarios. Results: Records consisted of 11,096 courses of radiation corresponding to 161,616 fractions. Baseline geographic access was estimated at 102.5 minutes ADT (each way, per fraction) and 75.9% C90. Adding 2 and 3 new centers increased C90 to 88% and 92%, respectively, and decreased ADT by between 43% and 61%, respectively. A scenario in which RT was provided in every potential location that could support at least 1 fully utilized linear accelerator resulted in 35.3 minutes' ADT and 93.6% C90. Conclusions: The proposed framework and model provide a data-driven means to quantitatively evaluate alternative configurations of a regional RT system. Results suggest that the choice of location for future centers can significantly improve geographic access to RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization Framework to Assess the Demand Response Capacity of a Water Distribution System

As large electricity consumers, water distribution system (WDS) pumping stations have the potential to become meaningful participants in demand response (DR) programs. The authors propose an optimization framework for assessing the DR capacity of a WDS and identifying the optimal bidding strategy for maximizing WDS revenue in the DR spot market. The proposed mixed integer linear programming (MILP) model overcomes computational constraints of previous DR optimization models by adopting a preprocessing procedure to minimize the number of binary variables and implementing a convex relaxation technique to linearize the hydraulic equations. The proposed MILP model also explicitly accounts for varying levels of risk tolerance of WDS operators by varying the recovery period over which pumping returns to business-as-usual operation. The optimization framework is implemented on a skeletonized 48-node WDS model that includes 7 pumps, 6 tanks, and 39 pipes. Using a simulated DR event and water consumption profile, the authors derive the optimal DR supply curves (i.e., compensation price versus load curtailment quantity) and revenue potential of the WDS under six scenarios for DR participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum Optimization and Approximation Algorithms

Shor's groundbreaking quantum algorithm for integer factoring provides an exponential speedup over the best-known classical algorithms. In the 20 years since Shor's algorithm was conceived, only a handful of fundamental quantum algorithmic kernels, generally providing modest polynomial speedups over classical algorithms, have been invented. To better understand the potential advantage quantum resources provide over their classical counterparts, one may consider other resources than execution time of algorithms. Quantum Approximation Algorithms direct the power of quantum computing towards optimization problems where quantum resources provide higher-quality solutions instead of faster execution times. We provide a new rigorous analysis of the recent Quantum Approximate Optimization Algorithm, demonstrating that it provably outperforms the best known classical approximation algorithm for special hard cases of the fundamental Maximum Cut graph-partitioning problem. We also develop new types of classical approximation algorithms for finding near-optimal low-energy states of physical systems arising in condensed matter by extending seminal discrete optimization techniques. Our interdisciplinary work seeks to unearth new connections between discrete optimization and quantum information science.

97 MATHEMATICS AND COMPUTING↗

Repair and Resource Scheduling in Unbalanced Distribution Systems Using Neighborhood Search

—This paper proposes an optimization strategy to assist utility operators to recover power distribution systems after large outages. Specifically, a mixed-integer linear programming (MILP) model is developed for co-optimizing crews, resources, and network operations. The MILP model coordinates damage isolation, network reconfiguration, distributed generator re-dispatch, and crew/resource logistics. In addition, a framework for integrating different types of photovoltaic (PV) systems in the restoration process is developed. We consider two different types of crews, namely, line crews for damage repair and tree crews for obstacle removal. We also model the repair resource logistic constraints. Furthermore, a new algorithm is developed for solving the distribution system repair and restoration problem (DSRRP). The algorithm starts by solving DSRRP using an assignmentbased method, then a neighborhood search method is designed to iteratively improve the solution. The proposed method is validated on modified IEEE 123- and 8500-bus distribution test systems.

Outage management↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center and partially by RaySearch Laboratories.

60 APPLIED LIFE SCIENCES↗

Process synthesis using block superstructure with automated flowsheet generation and optimization

An alternative method for chemical process synthesis using a block–based superstructure representation is proposed. The block–based superstructure is a collection of blocks arranged in a two–dimensional grid. The assignment of different equipment on blocks and the determination of their connectivity are performed using a mixed–integer nonlinear formulation for automated flowsheet generation and optimization–based process synthesis. Based on the special structure of the block representation, an efficient strategy is proposed to generate and successively refine feasible and optimized process flowsheets. Our approach is demonstrated using two process synthesis case studies adapted from the literature and one new process synthesis problem for methanol production from biogas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗