Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated Medical Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions

Radiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations—including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations. Important components are more detailed and improved anatomical models and more realistic biokinetic models than before. The ICRP is currently producing new organ dose and effective dose coefficients for occupational intakes of radionuclides (OIR) and environmental intakes of radionuclides (EIR), which supersede the earlier dose coefficients in Publication 68 and the Publication 72 series, respectively. However, the ICRP only publishes dose coefficients for a single acute intake of a radionuclide and for an integration period of 50 years for intake by adults and to age 70 years for intakes by pre-adults. The new software, IDAC-Bio, performs committed absorbed dose and effective dose calculations for a selectable intake scenario, e.g., for a continuous intake or an intake during x hours per day and y days per week, and for any selected integration time. The software uses the primary data and models of the ICRP biokinetic models and numerically solves the biokinetic model and calculates the absorbed doses to organs and tissues in the ICRP reference human phantoms. The software calculates absorbed dose using the nuclear decay data in ICRP publication 107. IDAC-Bio is a further development and an important addition to the internal dosimetry program IDAC-Dose2.1. Here, the results generated by the software were validated against published ICRP dose coefficients. The potential of the software is illustrated by dose calculations for a nuclear power plant worker who had been exposed to varying levels of 60 Co and who had undergone repeated whole-body measurements, and for a hypothetical member of the public subject to future releases of 148 Gd from neutron spallation in tungsten at the European Spallation Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beyond the List: Bioagent-Agnostic Signatures Could Enable a More Flexible and Resilient Biodefense Posture Than an Approach Based on Priority Agent Lists Alone

As of 2021, the biothreat policy and research communities organize their efforts around lists of priority agents, which elides consideration of novel pathogens and biotoxins. For example, the Select Agents and Toxins list is composed of agents that historic biological warfare programs had weaponized or that have previously caused great harm during natural outbreaks. Similarly, lists of priority agents promulgated by the World Health Organization and the National Institute of Allergy and Infectious Diseases are composed of previously known pathogens and biotoxins. To fill this gap, we argue that the research/scientific and biodefense/biosecurity communities should categorize agents based on how they impact their hosts to augment current list-based paradigms. Specifically, we propose integrating the results of multi-omics studies to identify bioagent-agnostic signatures (BASs) of disease—namely, patterns of biomarkers that accurately and reproducibly predict the impacts of infection or intoxication without prior knowledge of the causative agent. Here, we highlight three pathways that investigators might exploit as sources of signals to construct BASs and their applicability to this framework. The research community will need to forge robust interdisciplinary teams to surmount substantial experimental, technical, and data analytic challenges that stand in the way of our long-term vision. However, if successful, our functionality-based BAS model could present a means to more effectively surveil for and treat known and novel agents alike.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated Evaluation of Latent Viral Reactivation During Spaceflight

This application proposes a continuation of our current effort, which has provided the first demonstration of viral reactivation during space flight. We have used the herpesvirus EBV as a model for latent viral reactivation and have shown that increased amounts of EBV DNA were shed by astronauts during space flight. Analysis of the Antarctic space flight analog indicated that the frequency of viral shedding may also increase (along with the increased numbers of virus) during long periods of isolation. However, a number of critical questions remain before the findings may be considered a significant health risk during extended space flight. These include: Are other latent viruses (e.g., other herpesviruses and polyornaviruses) in addition to EBV also reactivated and shed more frequently and/or in higher numbers during space flight? Is the viral reactivation observed in space flight and ground-based analogs mediated through the hypothalamus-pituitary-adrenal (HPA) axis resulting in a decreased cell-mediated immune response? How does detection of viral DNA by PCR analysis correlate with infectious virus? How does the amount of virus found during flight compare with viral levels observed in acute/chronic viral illnesses and in control individuals? This expanded study will examine the phenomenon of viral reactivation from the initiating stress through the HPA axis with the accompanying suppression of the immune system resulting in viral reactivation. This information is essential to determine if latent viral reactivation among crewmembers represents a sufficient medical risk to space travel to require the development of suitable countermeasures.

Pierson, Duane L.↗

Clinical Decision Support Project

As NASA plans for exploration missions into deep space, significant challenges are realized due to the distance from Earth. Beside the effects of microgravity and radiation exposure, the astronauts face the additional constraints of isolation, lack of resupply, increasingly difficult evacuation, and delayed and disrupted communication with ground-based medical care providers. These constraints require a paradigm shift from current medical care where crews rely on the real-time communications with ground-based medical care providers toward Earth-independent medical operations for astronaut medical care. Medical expertise and decision-making are ground-based for current International Space Station and planned Lunar missions. However, a deep space exploration crew will need to autonomously perform the detection, diagnosis, treatment, and prevention of medical conditions. One approach to provide Earth-independent medical operations is to augment the requisite knowledge, skills, and abilities (KSAs) of a time-constrained crew—operating under stressful conditions, combatting fatigue, and facing a potential medical crisis—with a robust clinical decision support system (CDSS). The CDSS is envisioned as an integrated, software-based tool deployed on a laptop computer or handheld device. The CDSS will assist the crew and ground support when interacting with knowledge/data bases (e.g. records, pharmacy, schedule), instrumentation (e.g. imaging, physiological monitoring devices), and habitat (e.g. wellness system, task performance system) and vehicle systems (e.g. environmental system, communication system). In addition, the human interface will employ a context-based approach that accounts for the crew’s situation. Thus, extraneous and clinically/operationally non-relevant information are reduced to avoid an increase in cognitive load. The framework of an ideal spaceflight CDSS is to include core and advanced analytical features that maintain a flexible platform for integrating new technology in the future. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) is expanding the boundaries of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit by actively identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addressed ap Medical-701 within the Inflight Medical Conditions risk: “We need to increase inflight medical capabilities and identify new capabilities that (a) maximize benefit and/or (b) reduce “costs” on human system/mission/vehicle resources.” Though mass, volume, and power will face increasing constraints, the projected computational capabilities of spacecraft systems will increase exponentially as information technology advances in this decade and beyond. Hence, data, software, and computational resources will play an essential and synergistic role in maintaining crew health, wellness, and performance in deep space missions. The focus of the CDS project was to develop recommended requirements for an in-vehicle CDSS that acts as a ‘virtual assistant’ for delivering optimal health, performance, and medical care during exploration missions. In fiscal year 2022 (FY22), the CDS project was chartered to baseline and/or revise all CDS project related documentation and update the CDS project model to include the revised CDSS Concept of Operations, revised systems-based modeling language (SysML) activity diagrams, and baseline requirements. The focus of this presentation will be an overview of the CDS products and CDS model content.

Decision Support↗

Feature‐shared adaptive‐boost deep learning for invasiveness classification of pulmonary subsolid nodules in CT images

Purpose In clinical practice, invasiveness is an important reference indicator for differentiating the malignant degree of subsolid pulmonary nodules. These nodules can be classified as atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC). The automatic determination of a nodule's invasiveness based on chest CT scans can guide treatment planning. However, it is challenging, owing to the insufficiency of training data and their interclass similarity and intraclass variation. To address these challenges, we propose a two‐stage deep learning strategy for this task: prior‐feature learning followed by adaptive‐boost deep learning. Methods The adaptive‐boost deep learning is proposed to train a strong classifier for invasiveness classification of subsolid nodules in chest CT images, using multiple 3D convolutional neural network (CNN)‐based weak classifiers. Because ensembles of multiple deep 3D CNN models have a huge number of parameters and require large computing resources along with more training and testing time, the prior‐feature learning is proposed to reduce the computations by sharing the CNN layers between all weak classifiers. Using this strategy, all weak classifiers can be integrated into a single network. Results Tenfold cross validation of binary classification was conducted on a total of 1357 nodules, including 765 noninvasive (AAH and AIS) and 592 invasive nodules (MIA and IAC). Ablation experimental results indicated that the proposed binary classifier achieved an accuracy of with an AUC of 81.3 . These results are superior compared to those achieved by three experienced chest imaging specialists who achieved an accuracy of , , and , respectively. About 200 additional nodules were also collected. These nodules covered 50 cases for each category (AAH, AIS, MIA, and IAC, respectively). Both binary and multiple classifications were performed on these data and the results demonstrated that the proposed method definitely achieves better performance than the performance achieved by nonensemble deep learning methods. Conclusions It can be concluded that the proposed adaptive‐boost deep learning can significantly improve the performance of invasiveness classification of pulmonary subsolid nodules in CT images, while the prior‐feature learning can significantly reduce the total size of deep models. The promising results on clinical data show that the trained models can be used as an effective lung cancer screening tool in hospitals. Moreover, the proposed strategy can be easily extended to other similar classification tasks in 3D medical images.

Wang, Jun↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Spinoff 2013

Topics covered include: Innovative Software Tools Measure Behavioral Alertness; Miniaturized, Portable Sensors Monitor Metabolic Health; Patient Simulators Train Emergency Caregivers; Solar Refrigerators Store Life-Saving Vaccines; Monitors Enable Medication Management in Patients' Homes; Handheld Diagnostic Device Delivers Quick Medical Readings; Experiments Result in Safer, Spin-Resistant Aircraft; Interfaces Visualize Data for Airline Safety, Efficiency; Data Mining Tools Make Flights Safer, More Efficient; NASA Standards Inform Comfortable Car Seats; Heat Shield Paves the Way for Commercial Space; Air Systems Provide Life Support to Miners; Coatings Preserve Metal, Stone, Tile, and Concrete; Robots Spur Software That Lends a Hand; Cloud-Based Data Sharing Connects Emergency Managers; Catalytic Converters Maintain Air Quality in Mines; NASA-Enhanced Water Bottles Filter Water on the Go; Brainwave Monitoring Software Improves Distracted Minds; Thermal Materials Protect Priceless, Personal Keepsakes; Home Air Purifiers Eradicate Harmful Pathogens; Thermal Materials Drive Professional Apparel Line; Radiant Barriers Save Energy in Buildings; Open Source Initiative Powers Real-Time Data Streams; Shuttle Engine Designs Revolutionize Solar Power; Procedure-Authoring Tool Improves Safety on Oil Rigs; Satellite Data Aid Monitoring of Nation's Forests; Mars Technologies Spawn Durable Wind Turbines; Programs Visualize Earth and Space for Interactive Education; Processor Units Reduce Satellite Construction Costs; Software Accelerates Computing Time for Complex Math; Simulation Tools Prevent Signal Interference on Spacecraft; Software Simplifies the Sharing of Numerical Models; Virtual Machine Language Controls Remote Devices; Micro-Accelerometers Monitor Equipment Health; Reactors Save Energy, Costs for Hydrogen Production; Cameras Monitor Spacecraft Integrity to Prevent Failures; Testing Devices Garner Data on Insulation Performance; Smart Sensors Gather Information for Machine Diagnostics; Oxygen Sensors Monitor Bioreactors and Ensure Health and Safety; Vision Algorithms Catch Defects in Screen Displays; and Deformable Mirrors Capture Exoplanet Data, Reflect Lasers.

Source record↗

Countermeasure Evaluation and Validation Project (CEVP) Database Requirement Documentation

The initial focus of the project by the JSC laboratories will be to develop, test and implement a standardized complement of integrated physiological test (Integrated Testing Regimen, ITR) that will examine both system and intersystem function, and will be used to validate and certify candidate countermeasures. The ITR will consist of medical requirements (MRs) and non-MR core ITR tests, and countermeasure-specific testing. Non-MR and countermeasure-specific test data will be archived in a database specific to the CEVP. Development of a CEVP Database will be critical to documenting the progress of candidate countermeasures. The goal of this work is a fully functional software system that will integrate computer-based data collection and storage with secure, efficient, and practical distribution of that data over the Internet. This system will provide the foundation of a new level of interagency and international cooperation for scientific experimentation and research, providing intramural, international, and extramural collaboration through management and distribution of the CEVP data. The research performed this summer includes the first phase of the project. The first phase of the project is a requirements analysis. This analysis will identify the expected behavior of the system under normal conditions and abnormal conditions; that could affect the system's ability to produce this behavior; and the internal features in the system needed to reduce the risk of unexpected or unwanted behaviors. The second phase of this project have also performed in this summer. The second phase of project is the design of data entry screen and data retrieval screen for a working model of the Ground Data Database. The final report provided the requirements for the CEVP system in a variety of ways, so that both the development team and JSC technical management have a thorough understanding of how the system is expected to behave.

Shin, Sung Y.↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Introduction to the IMPACT Probabilistic Risk and Tradespace Analysis Tool for Medical System Design

Background: Probabilistic risk analysis (PRA) is a method for estimating risk in complex engineered systems that, at a basic level, focuses on what can go wrong and the likelihood and consequences of those occurrences. NASA has used PRA as an integral component of medical system risk estimation and design for spaceflight. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a novel tool to meet these goals for exploration missions. Overview: IMPACT performs hundreds of thousands of Monte Carlo simulations of missions to build aggregate pictures of medical risk. These simulations are based on 120 possible medical conditions (the IMPACT Condition List) selected in a consensus-based process because they are of highest likelihood and/or consequence for exploration spaceflight. The conditions are then tied to clinical capabilities which can be used for management (e.g., inserting an IV) and then to over 600 specific resources needed to deliver a capability (e.g., an angiocath or an ultrasound). Different mission profiles can be simulated with user-specified inputs such as mission duration, destination, number of crew and pre-existing medical conditions, and EVA frequency. While the IMPACT evidence base is designed for exploration environments, these user inputs allow the tool to be used across a broad range of missions. IMPACT’s primary outcome metrics include loss of crew life (LOCL, a measure of in-flight mortality due to medical conditions), need for evacuation (RTDC, return to definitive care), and crew disability (TTL, task time lost based on how medical conditions impact the ability to perform over 1000 specific exploration mission crew tasks). In addition to modeling medical risk, IMPACT also accepts user-specified constraints, such as limitations of mass or volume, and will output a recommended clinical capability set and specific medical resources that meet the mission constraints. Discussion: This abstract will provide an introduction to IMPACT and describe the nature of the underlying medical evidence. It will also detail potential use cases for how this tool can be utilized by NASA or commercial spaceflight providers.

Ben Easter↗

The ModelSEED Biochemistry Database for the integration of metabolic annotations and the reconstruction, comparison and analysis of metabolic models for plants, fungi and microbes

Abstract For over 10 years, ModelSEED has been a primary resource for the construction of draft genome-scale metabolic models based on annotated microbial or plant genomes. Now being released, the biochemistry database serves as the foundation of biochemical data underlying ModelSEED and KBase. The biochemistry database embodies several properties that, taken together, distinguish it from other published biochemistry resources by: (i) including compartmentalization, transport reactions, charged molecules and proton balancing on reactions; (ii) being extensible by the user community, with all data stored in GitHub; and (iii) design as a biochemical ‘Rosetta Stone’ to facilitate comparison and integration of annotations from many different tools and databases. The database was constructed by combining chemical data from many resources, applying standard transformations, identifying redundancies and computing thermodynamic properties. The ModelSEED biochemistry is continually tested using flux balance analysis to ensure the biochemical network is modeling-ready and capable of simulating diverse phenotypes. Ontologies can be designed to aid in comparing and reconciling metabolic reconstructions that differ in how they represent various metabolic pathways. ModelSEED now includes 33,978 compounds and 36,645 reactions, available as a set of extensible files on GitHub, and available to search at https://modelseed.org and KBase.

59 BASIC BIOLOGICAL SCIENCES↗

Multimodal framework for the joint analysis of single-cell RNA and T cell receptor sequencing data predicts T cell response to cancer immunotherapy

T cell states are prognostic in different cancer types. Recent technologies enable joint profiling of T cell RNA and T cell receptor (TCR) sequences at single-cell resolution. Here we present the TCR-RNA Integrating Model (TRIM), a multi-modal variational autoencoder framework that integrates RNA-TCR data and predicts T cell clonality and transcriptional states. TRIM learns a shared representation of the data conditioned on patient, tissue source, and treatment timepoint. We applied TRIM to three independent datasets that included T cells collected before and after checkpoint inhibitor treatment, sourced either from blood and tumor biopsies in patients with head and neck squamous cell carcinoma and colorectal cancer, or from tumor and adjacent tissue in a pan-cancer dataset. In all settings, TRIM accurately predicted intra-tumor T cell clonal expansion and transcriptional status based on T cells from blood or normal tissue before treatment, demonstrating its utility in modeling multimodal T cell data and predicting T cell response to treatment and disease progression.

60 APPLIED LIFE SCIENCES↗

FRET-based dynamic structural biology: Challenges, perspectives and an appeal for open-science practices

Single-molecule FRET (smFRET) has become a mainstream technique for studying biomolecular structural dynamics. The rapid and wide adoption of smFRET experiments by an ever-increasing number of groups has generated significant progress in sample preparation, measurement procedures, data analysis, algorithms and documentation. Several labs that employ smFRET approaches have joined forces to inform the smFRET community about streamlining how to perform experiments and analyze results for obtaining quantitative information on biomolecular structure and dynamics. The recent efforts include blind tests to assess the accuracy and the precision of smFRET experiments among different labs using various procedures. These multi-lab studies have led to the development of smFRET procedures and documentation, which are important when submitting entries into the archiving system for integrative structure models, PDB-Dev. This position paper describes the current ‘state of the art’ from different perspectives, points to unresolved methodological issues for quantitative structural studies, provides a set of ‘soft recommendations’ about which an emerging consensus exists, and lists openly available resources for newcomers and seasoned practitioners. To make further progress, we strongly encourage ‘open science’ practices.

59 BASIC BIOLOGICAL SCIENCES↗

Integrating Ultra-Coarse-Grained Protein Models into Accessible Workflows for Multiscale Molecular Dynamics

To capture protein conformational transitions using molecular dynamics (MD), several simulation resolutions covering different spatial and temporal scales are typically needed. All-atom (AA) simulations provide fine resolution, but are computationally infeasible for large systems over longer durations. Coarse-grained (CG) and ultra-coarse-grained (UCG) models have a lower resolution and computational cost while still being able to conserve essential protein features. Prior work on a Multiscale Machinelearned Modeling Infrastructure (MuMMI) combined both AA and CG simulations to study RAS-RAF protein interactions, leveraging CG models for longer time scales and using AA to investigate unusual conformations in greater detail. However, MuMMI is still resource-intensive, and this study aims to maximize exploration of the protein conformational space while reducing computational cost. In this paper, we build on prior work that integrates UCG models based on heterogeneous elastic network modeling (hENM) into the MuMMI workflow. We demonstrate that UCG models enable accurate sampling of protein conformations, focusing on simulating RAS-RAF protein interactions. Using higher-resolution CG Martini simulation data, we can automatically refine intramolecular interactions in UCG models. We present a scalable Python package that uses fluctuations observed in higher-resolution CG Martini simulations to estimate bond coefficients of the UCG model. We built novel machine learning-based backmapping methods to recover more detailed CG Martini structures from UCG structures, using diffusion models to learn the mapping between scales. Finally, we present UCG-mini-MuMMI, an accessible and less compute-intensive version of MuMMI as a resource for the scientific community. Incorporating UCG models into MD studies is applicable to a broad range of systems and proteins, and our study offers insights into the advantages and limitations of these methods.

Chemical structure↗

Open-Source and FAIR Research Software for Proteomics

Scientific discovery relies on innovative software as much as experimental methods, especially in proteomics, where computational tools are essential for mass spectrometer setup, data analysis, and interpretation. Since the introduction of SEQUEST, proteomics software has grown into a complex ecosystem of algorithms, predictive models, and workflows, but the field faces challenges, including the increasing complexity of mass spectrometry data, limited reproducibility due to proprietary software, and difficulties integrating with other omics disciplines. Closed-source, platform-specific tools exacerbate these issues by restricting innovation, creating inefficiencies, and imposing hidden costs on the community. Open-source software (OSS), aligned with the FAIR Principles (Findable, Accessible, Interoperable, Reusable), offers a solution by promoting transparency, reproducibility, and community-driven development, which fosters collaboration and continuous improvement. In this manuscript, we explore the role of OSS in computational proteomics, its alignment with FAIR principles, and its potential to address challenges related to licensing, distribution, and standardization. Drawing on lessons from other omics fields, we present a vision for a future where OSS and FAIR principles underpin a transparent, accessible, and innovative proteomics community.

97 MATHEMATICS AND COMPUTING↗

Capturing, Analyzing, Maintaining, and Disseminating Shape Memory Material Data Between Information Management Systems

With an increased demand on reducing the time, cost, and effort to develop new materials, Integrated Computational Materials Engineering (ICME) has received widespread attention in various engineering disciplines as a catalyst for significantly reducing experimental testing during the material design process. An ICME approach to design can enable ‘fit-for-purpose’ materials to be realized in engineering applications by incorporating well-understood process-property-performance relationships between the various length and time scales in a material’s structure, enabling material optimization. However, such an approach requires validated multiscale models at the various length scales for a material, which in turn requires a large amount of data, a robust means of storing the data, and the ability to link data to developed material models. The NASA Vision 2040 [1] has identified nine key elements to enabling ICME approaches in system level design, with one being “Data, Information, and Visualization”, thus outlining the importance of a robust information management system for ICME. As the relationship between microstructure, properties, and material performance become better understood and incorporated into multiscale models that can be leveraged in application design, the emergence of new materials with application-driven properties can be realized. One such new material class that has seen growing attention are shape memory materials (SMM), in which a material can transition between a deformed and undeformed state via a reversible phase transformation when subject to a thermal, mechanical, or magnetic load [2]. SMMs have been used widely in aerospace and biomedical industries, including applications such as actuators, low-shock mechanisms, medical staples, braces, and stents [3, 4]. These materials exhibit unique behavior due to their ability to transition between phases, and thus the mechanisms that enable this transition must be captured in a data information management system and incorporated into SMM material models. At NASA Glenn Research Center, the Shape Memory Materials Database (SMMD) Tool has been developed to capture the necessary information that governs SMM material behavior and provide users the ability to select and visualize various SMMs for a specific application [5]. The database contains point-wise data for published SMM materials, along with the pedigree metadata for traceability necessary for a robust information management system. The database is also capable of storing in-house test data performed at NASA GRC by interacting with the developed Shape Memory Alloy (SMA) Analytics tool to extract the necessary point-wise values and populate the database. Although the SMMD Tool offers its users a single, authoritative source for SMM material data that is critical for model development and material design, the full material pedigree of the in-house test data for SMMs is not currently captured and is out of the scope for the SMMD tool. In this work, the schema for capturing SMM test data within the larger NASA GRC ICME Schema [6, 7, 8, 9] will be developed and implemented for thermomechanical tests conducted at NASA GRC. The developed schema will not only store the relevant data needed for the SMMD tool, but also the material pedigree (i.e., production of the bulk material, bulk material analysis, sample cut-out diagrams, sample fabrication procedure, etc.), test pedigree (i.e., test equipment used, measurement systems used, raw test data), and analysis pedigree (i.e., how the data in the SMMD tool is calculated). Furthermore, a Python-based framework will be developed to seamlessly interact between the SMA Analytics and SMMD tools, which will write the full dataset and associated metadata to the GRC Information Management System before passing the required point-wise data to the SMMD tool. Data informatics is a key element of the NASA Vision 2040, which requires not only that data is stored and maintained throughout the material lifecycle, but that the data is also accessible and reusable such that material development efforts can be minimized. Therefore, for an ICME design approach to be realized, a centralized information management system that drives the ICME process must be able to communicate with other databases. The work that will be presented in this presentation will therefore not only demonstrate the ability of NASA GRC’s information management system to capture SMM data, but also its ability to interact with pre-existing tools specialized for such materials.

Data management↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗