Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Dynamically polarized target for the g p 2 and G p E experiments at Jefferson Lab

We describe a dynamically polarized target that has been utilized for two electron scattering experiments in Hall A at Jefferson Lab. The primary components of the target are a new, high cooling power 4 He evaporation refrigerator, and a re-purposed, superconducting split-coil magnet. It has been used to polarize protons in irradiated NH 3 at a temperature of 1 K and at fields of 2.5 and 5.0 Tesla. The performance of the target material in the electron beam under these conditions will be discussed. The maximum polarizations of 28% and 95% were obtained at those fields, respectively. To satisfy the requirements of both experiments, the magnet had to be routinely rotated between angles of 0, 6, and 90 degrees with respect to the incident electron beam. This was accomplished using a new rotating vacuum seal which permits rotations to be performed in only a few minutes.

43 PARTICLE ACCELERATORS↗

Simulations of a FIR Oscillator with Large Slippage parameter at Jefferson Lab for FIR/UV pump-probe experiments

We previously proposed a dual FEL configuration on the UV Demo FEL at Jefferson Lab that would allow simultaneous lasing at FIR and UV wavelengths. The FIR source would be an FEL oscillator with a short wiggler providing diffraction-limited pulses with pulse energy exceeding 50 microJoules, using the exhaust beam from a UVFEL as the input electron beam. Since the UV FEL requires very short pulses, the input to the FIR FEL is extremely short compared to a slippage length and the usual Slowly Varying Envelope Approximation (SVEA) does not apply. We use a non-SVEA code to simulate this system both with a small energy spread (UV laser off) and with large energy spread (UV laser on).

43 PARTICLE ACCELERATORS↗

Superconducting Magnet Power Supply and Hard-Wired Quench Protection at Jefferson Lab for 12 GeV Upgrade

The superconducting magnet system in Hall B being designed and built as part of the Jefferson Lab 12 GeV upgrade requires powering two conduction cooled superconducting magnets - a torus and a solenoid. The torus magnet is designed to operate at 3770 A and solenoid at 2416 A. Failure Modes and Effects Analysis (FMEA) determined that voltage level thresholds and dump switch operation for magnet protection should be tested and analyzed before incorporation into the system. The designs of the quench protection and voltage tap sub-systems were driven by the requirement to use a primary hard-wired quench detection sub-system together with a secondary PLC-based protection. Parallel path voltage taps feed both the primary and secondary quench protection sub-systems. The PLC based secondary protection is deployed as a backup for the hard-wired quench detection sub-system and also acts directly on the dump switch. Here, we describe a series of tests and modifications carried out on the magnet power supply and quench protection system to ensure that the superconducting magnet is protected for all fault scenarios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma processing of SRF cavities at Jefferson Lab: Experiment results and simulation insight

Plasma processing of superconducting radio frequency (SRF) cavities has been an active research effort at Jefferson Lab (JLab) since 2019, aimed at enhancing cavity performance by removing hydrocarbon contaminants and reducing field emission. In this experiment, processing using argon-oxygen and helium-oxygen gas mixtures to find minimum ignition power at different cavity pressure was investigated. Ongoing simulations are contributing to a better understanding of the plasma surface interactions and the fundamental physics behind the process. These simulations, combined with experimental studies, guide the optimization of key parameters such as gas type, RF power, and pressure to ignite plasma using selected higher-order mode (HOM) frequencies. This paper presents experimental data from argon-oxygen and helium-oxygen gas mixture C75 and C100 cavity plasma ignition studies, as well as simulation results for the C100-type cavity based on the COMSOL model previously applied to the C75 cavity.

Accelerator Physics↗

Jefferson Lab injector development for next generation parity violation experiments

To meet the challenging requirements of next generation parity violation experiments at Jefferson Lab, the Center for Injectors and Sources is working on improving the parity-quality of the electron beam. These improvements include new electron photogun design and fast helicity reversal of the Pockels Cell. We proposed and designed a new scheme for slow helicity reversal using a Wien Filter and two Solenoids. This slow reversal complements the insertable half-wave plate reversal of the laser-light polarization by reversing the electron beam polarization at the injector while maintaining a constant accelerator configuration. For position feedback, fast air-core magnets located in the injector were commissioned and a new scheme for charge feedback is planned.

43 PARTICLE ACCELERATORS↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- η experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Jefferson Lab 12 GeV Upgrade

Construction of the 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility is presently underway. This upgrade includes doubling the energy of the electron beam to 12 GeV, the addition of a new fourth experimental hall, and the construction of upgraded detector hardware. An overview of this upgrade project is presented, along with highlights of the anticipated experimental program. The 12 GeV upgrade project at Jefferson Lab will enable a powerful new experimental program that will advance our understanding of the quark/gluon structure of hadronic matter, the nature of Quantum Chromodynamics, and the properties of a new extended standard model of particle interactions. Commissioning of the upgraded beam will be begin in 2013, and the full complement of upgraded experimental equipment will be completed in 2015. This unique facility will provide many opportunities for exploration and discovery for a large international community of nuclear scientists.

43 PARTICLE ACCELERATORS↗

Liquid nitrogen tests of a Torus coil for the Jefferson Lab 12GeV accelerator upgrade

A magnet system consisting of six superconducting trapezoidal racetrack-type coils is being built for the Jefferson Lab 12-GeV accelerator upgrade project. The magnet coils are wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. Each superconducting toroidal coil is force cooled by liquid helium, which circulates in a tube that is in good thermal contact with the inside of the coil. Thin copper sheets are soldered to the helium cooling tube and enclose the superconducting coil, providing cooling to the rest of the coil pack. As part of a rigorous risk mitigation exercise, each of the six coils is cooled with liquid nitrogen (LN2) to 80 K to validate predicted thermal stresses, verify the robustness and integrity of electrical insulation, and evaluate the efficacy of the employed conduction cooling method. This paper describes the test setup, the tests performed, and the findings.

Torus, SSC-NbTi, LN2 cold test, FEA, epoxy potting↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Final Booster Complex Design for the Jefferson Lab Electron Ion Collider*

In this work we show the final iteration of the design for the booster complex of the Jefferson Lab EIC, which would have brought the ions from an energy (proton) of 150 MeV up to 12.1 GeV. This complex would have consisted of two figure-8 rings. The Low Energy Booster (LEB) which would have accelerated its protons from 150 MeV to 8 GeV, and has had its lattice tweaked to increase the effectiveness of chromaticity cancellations. The High Energy Booster (HEB) would have brought the 8 GeV protons up to 12.1 GeV. The HEB would in the tunnel that was designed for the collider rings, sitting on top of them. It has had a bypass around the interaction region added, as well as a cooling solenoid installed.

Nissen, E. A.↗

An e-beam irradiation beamline at Jefferson Lab for 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) remediation in wastewater

The Upgraded Injector Test Facility (UITF) at Jefferson Lab, providing a beam energy up to 10 MeV, is suitable for wastewater remediation research. To investigate the degradation of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS), widespread in wastewater and potential to be regulated in near future, a beamline for electron-beam irradiation has been designed, installed and successfully commissioned at the UITF. A solenoid with a peak axial magnetic field of up to 0.28 T and a raster were used to obtain a Gaussian beam profile with a transverse standard deviation of 15 mm. It was applied to irradiate 1,4-dioxane sample filled in the target cell that was designed to let the entire sample receive significant irradiation doses. The dose distribution and absorbed dose, few studied in the current publications, are necessary measures for the degradation mechanism investigation and have been innovatively achieved in this work using simulations which were calibrated with opti-chromic dosimeter rods directly exposed to the electron beam. This approach provides an important way for investigating the environmental remediation impact of electron-beam irradiation.

Li, Xi↗

Development of Advanced Beam Halo Diagnostics at the Jefferson Lab Free-Electron-Laser Facility

High average current and high brightness electron beams are needed for many applications. At the Jefferson Lab FEL facility, the search for dark matter with the FEL laser beam has produced some interesting results, and a second very promising experiment called DarkLight, using the JLab Energy-recovery-linac (ERL) machine has been put forward. Although the required beam current has been achieved on this machine, one key challenge is the management of beam halo. At the University of Md. (UMD) we have demonstrated a high dynamic range halo measurement method using a digital micro-mirror array device (DMD). A similar system has been established at the JLab FEL facility as a joint effort by UMD and JLab to measure the beam halo on the high current ERL machine. Preliminary experiments to characterize the halo were performed on the new UV FEL. In this paper, the limitations of the present system will be analyzed and a discussion of other approaches (such as an optimized coronagraph) for further extending the dynamic range will be presented. We will also discuss the possibility of performing both longitudinal and transverse (3D) halo measurements together on a single system.

43 PARTICLE ACCELERATORS↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗

The Jefferson Lab tritium program of nucleon and nuclear structure measurements

In this work a series of experiments were performed in Hall A of Jefferson Lab in 2018 that used a novel tritium and helium-3 target system. These experiments took advantage of the isospin symmetry of these mirror nuclei to make precise measurements of isospin dependence in both nucleon and nuclear structure. We summarize here the design and properties of these cells, the physics measurements that have been published, and results currently under analysis from this program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab

Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

CLAS12 and its initial Science Program at the Jefferson Lab Upgrade

An overview of the CLAS12 detector is presented and the initial physics program after the energy-doubling of the Jefferson Lab electron accelerator. Construction of the 12 GeV upgrade project has started October 2008. A broad program has been developed to map the nucleon's 3-dimensional spin and flavor content through the measurement of deeply exclusive and semi-inclusive processes. Other programs include forward distribution function to large $x_{B} \le 0.85$ and of the quark and gluon polarized distribution functions, as well as nucleon ground state and transition form factors at high $Q^2$. The 12 GeV electron beam and the large acceptance of CLAS12 are also well suited to explore hadronization properties using the nucleus as a laboratory

43 PARTICLE ACCELERATORS↗