Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

79 ASTRONOMY AND ASTROPHYSICS↗

THE LOCATION OF SOLAR METRIC TYPE II RADIO BURSTS WITH RESPECT TO THE ASSOCIATED CORONAL MASS EJECTIONS

Forty-one solar type II radio bursts located close to the solar limb (projected radial distance r {approx}> 0.8 R{sub Sun }) were observed at 109 MHz by the radioheliograph at the Gauribidanur observatory near Bangalore during the period 1997-2007. The positions of the bursts were compared with the estimated location of the leading edge (LE) of the associated coronal mass ejections (CMEs) close to the Sun. 38/41 of the type II bursts studied were located either at or above the LE of the associated CME. In the remaining 3/41 cases, the burst was located behind the LE of the associated CME at a distance of <0.5 R{sub Sun }. Our results suggest that nearly all the metric type II bursts are driven by the CMEs.

79 ASTRONOMY AND ASTROPHYSICS↗

C/O and snowline locations in protoplanetary disks: the effect of radial drift and viscous gas accretion

The C/O ratio is a defining feature of both gas giant atmospheric and protoplanetary disk chemistry. In disks, the C/O ratio is regulated by the presence of snowlines of major volatiles at different distances from the central star. We explore the effect of the radial drift of solids and viscous gas accretion onto the central star on the snowline locations of the main C and O carriers in a protoplanetary disk, H{sub 2}O, CO{sub 2}, and CO, and their consequences for the C/O ratio in gas and dust throughout the disk. We determine the snowline locations for a range of fixed initial particle sizes and disk types. For our fiducial disk model, we find that grains with sizes ∼0.5 cm ≲ s ≲ 7 m for an irradiated disk and ∼0.001 cm ≲ s ≲ 7 m for an evolving and viscous disk desorb at a size-dependent location in the disk, which is independent of the particle's initial position. The snowline radius decreases for larger particles, up to sizes of ∼7 m. Compared to a static disk, we find that radial drift and gas accretion in a viscous disk move the H{sub 2}O snowline inwards by up to 40%, the CO{sub 2} snowline by up to 60%, and the CO snowline by up to 50%. We thus determine an inner limit on the snowline locations when radial drift and gas accretion are accounted for.

79 ASTRONOMY AND ASTROPHYSICS↗

Setting the H-mode pedestal structure: variations of particle source location using gas puff and pellet fueling

Experiments in DIII-D show that a particle source location inside the top of the H-mode pedestal (pellets) maintains a higher pedestal pressure than an edge source (gas fueling) through a widening of the electron temperature pedestal with reduction of the temperature gradient. The effect of these two fueling schemes on the H-mode pedestal structure was examined in DIII-D by comparing controlled pellet-fueled and gas-fueled discharges across a fueling scan up to 40 torr 1 s –1 . High resolution electron profiles reveal that gas fueling lowers the pedestal pressure as the density profile shifts radially outwards and the separatrix density increases, while pellet fueling maintains a constant pedestal pressure. The neutral source locations from pellets and gas are determined with the PELLET and UEDGE codes, respectively, and quantify the particle source localization. Pellets provide significant ionization inside the pedestal top while gas puffing localizes ionization in the scrape-off-layer and pedestal foot, broadly consistent with the density profile structure influenced by the source. ELMs are observed to increase in frequency and reduce impurity content as fueling is increased. Stability analysis with ELITE shows that both conditions are near the type-I ELM corner of the peeling–ballooning stability diagram, which is altered significantly by the introduction of pellets. Since transport mechanisms are not observed to change substantially with particle source location, wider pedestals allow the pellet-fueled discharges to retain higher pedestal temperatures at similar pedestal densities. EPED1 is tested to capture the pedestal pressure, under-predicting the height with pellets and over-predicting the height with gas by ~15%. Overall, these results have important implications for future reactors where pellet fueling will be the primary particle source due to an opaque scrape-off-layer by showing that the neutral source location plays a role in setting the structure of the H-mode pedestal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaled Tests and Modeling of Effluent Stack Sampling Location Mixing

The Pacific Northwest National Laboratory researchers used a computational fluid dynamics (CFD) computer code to evaluate the mixing at a sampling system location of a research and development facility. The facility requires continuous sampling for radioactive air emissions. Researchers sought to determine whether the location would meet the criteria for uniform air velocity and contaminant concentration as prescribed in the American National Standard Institute (ANSI) standard, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. Standard ANSI/HPS N13.1-1999 requires that the sampling location be well-mixed and stipulates specific tests (e.g., velocity, gas, and aerosol uniformity and cyclonic flow angle) to verify the extent of mixing.. The exhaust system for the Radiochemical Processing Laboratory was modeled with a CFD code to better understand the flow and contaminant mixing and to predict mixing test results. The CFD results were compared to actual measurements made at a scale-model stack and to the limited data set for the full-scale facility stack. Results indicated that the CFD code provides reasonably conservative predictions for velocity, gas, and aerosol uniformity. Cyclonic flow predicted by the code is less than that measured by the required methods. In expanding from small to full scale, the CFD predictions for full-scale measurements show similar trends as in the scale model and no unusual effects. This work indicates that a CFD code can be a cost-effective aid in design or retrofit of a facility’s stack sampling location that will be required to meet Standard ANSI/HPS N13.1-1999.

air monitoring↗

Location-dependent communications using quantum entanglement

The ability to unconditionally verify the location of a communication receiver would lead to a wide range of new security paradigms. However, it is known that unconditional location verification in classical communication systems is impossible. In this work we show how unconditional location verification can be achieved with the use of quantum communication channels. Our verification remains unconditional irrespective of the number of receivers, computational capacity, or any other physical resource held by an adversary. Quantum location verification represents an application of quantum entanglement that delivers a feat not possible in the classical-only channel. It gives us the ability to deliver real-time communications viable only at specified geographical coordinates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Techno-economic assessment of electricity market potential for co-located hydro-floating PV systems

Abstract—Harnessing renewable energy from diverse sources is paramount for sustainable power systems. Recently, co-located floating PV (FPV) systems present an intriguing prospect in this context. These hybrid systems, blending hydro and solar power, may offer a more consistent electricity output and potential economic advantages. Yet, assessing their actual potential requires a comprehensive techno-economic assessment. In addition, probabilistic price forecasting has recently gained attention in electricity market because decisions based on such predictions can yield significantly higher profits than those made with point forecasts alone. To this end, this paper embarks on a journey to elucidate the electricity market potential of co-located hydro-FPV systems in a probabilistic fashion to investigate the technological merits and economic viability of co-located hydro-FPV under different market structures. Our preliminary findings suggest that LCOE and payback metrics are sensitive not only to different markets but also to different solar incentives. Concurrently, we also observe that the payback period is generally faster with a production tax credit (PTC) than an investment tax credit (ITC). This assessment serves as a cornerstone for understanding the future prospects of co-located hydro-FPV systems in modern electricity markets.

13 HYDRO ENERGY↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain

Purpose: The purpose of this study was to investigate the correlation between model observer and human observer performance in CT imaging for the task of lesion detection and localization when the lesion location is uncertain.Methods: Two cylindrical rods (3-mm and 5-mm diameters) were placed in a 35 × 26 cm torso-shaped water phantom to simulate lesions with −15 HU contrast at 120 kV. The phantom was scanned 100 times on a 128-slice CT scanner at each of four dose levels (CTDIvol = 5.7, 11.4, 17.1, and 22.8 mGy). Regions of interest (ROIs) around each lesion were extracted to generate images with signal-present, with each ROI containing 128 × 128 pixels. Corresponding ROIs of signal-absent images were generated from images without lesion mimicking rods. The location of the lesion (rod) in each ROI was randomly distributed by moving the ROIs around each lesion. Human observer studies were performed by having three trained observers identify the presence or absence of lesions, indicating the lesion location in each image and scoring confidence for the detection task on a 6-point scale. The same image data were analyzed using a channelized Hotelling model observer (CHO) with Gabor channels. Internal noise was added to the decision variables for the model observer study. Area under the curve (AUC) of ROC and localization ROC (LROC) curves were calculated using a nonparametric approach. The Spearman's rank order correlation between the average performance of the human observers and the model observer performance was calculated for the AUC of both ROC and LROC curves for both the 3- and 5-mm diameter lesions.Results: In both ROC and LROC analyses, AUC values for the model observer agreed well with the average values across the three human observers. The Spearman's rank order correlation values for both ROC and LROC analyses for both the 3- and 5-mm diameter lesions were all 1.0, indicating perfect rank ordering agreement of the figures of merit (AUC) between the average performance of the human observers and the model observer performance.Conclusions: In CT imaging of different sizes of low-contrast lesions (−15 HU), the performance of CHO with Gabor channels was highly correlated with human observer performance for the detection and localization tasks with uncertain lesion location in CT imaging at four clinically relevant dose levels. This suggests the ability of Gabor CHO model observers to meaningfully assess CT image quality for the purpose of optimizing scan protocols and radiation dose levels in detection and localization tasks for low-contrast lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-06: Correlation of Lung Tumor Motion with Tumor Location Using Electromagnetic Tracking

Purpose: It is well known that lung tumors move with respiration. However, most measurements of lung tumor motion have studied long treatment times with intermittent imaging; those populations may not necessarily represent conventional LINAC patients. We summarized the correlation between tumor motion and location in a multi-institutional trial with electromagnetic tracking, and identified the patient cohort that would most benefit from respiratory gating. Methods: Continuous electromagnetic transponder data (Varian Medical, Seattle, WA) of lung tumor motion was collected from 14 patients (214 total fractions) across 3 institutions during external beam radiation therapy in a prospective clinical trial (NCT01396551). External intervention from the clinician, such as couch shifts, instructed breath-holds, and acquisition pauses, were manually removed from the 10 Hz tracking data according to recorded notes. The average three-dimensional displacement from the breathing cycle’s end-expiratory to end-inhalation phases (peak-to-peak distance) of the transponders’ isocenter was calculated for each patient’s treatment. A weighted average of each isocenter was used to assess the effects of location on motion. A total of 14 patients were included in this analysis, grouped by their transponders’ location in the lung: upper, medial, and lower. Results: 8 patients had transponders in the upper lung, and 3 patients each in the medial lobe and lower lung. The weighted average ± standard deviation of all peak-to-peak distances for each group was: 1.04 ± 0.39 cm in the lower lung, 0.56 ± 0.14 cm in the medial lung, and 0.30 ± 0.06 cm in the upper lung. Conclusion: Tumors in the lower lung are most susceptible to excessive motion and daily variation, and would benefit most from continuous motion tracking and gating. Those in the medial lobe might be at moderate risk. The upper lobes have limited motion. These results can guide different motion management strategies between lung tumor locations. This is part of an NIH-funded prospective clinical trial (NCT01396551), using an electromagnetic transponder tracking system and additional funding from Varian Medical (Seattle, WA).

60 APPLIED LIFE SCIENCES↗

WE-H-207A-04: Impact of Lesion Location On the Repeatability of 18F-NaF PET/CT

Purpose: Quantifying the repeatability of imaging biomarkers is critical for assessing therapeutic response. While {sup 18}F-NaF PET/CT has shown to be a repeatable imaging method, research has not shown which factors may influence its repeatability. The purpose of this study was to evaluate whether the location of the lesion impacts the repeatability of quantitative {sup 18}F-NaF PET-derived SUV metrics. Methods: Metastatic castrate-resistant prostate cancer patients with multiple bone lesions received whole-body test-retest NaF PET/CT scans. Malignant bone lesions of PET-defined volume greater than 1.5 cm{sup 3} were identified by a nuclear medicine physician and automatically delineated using a SUV>15 threshold. The maximum (SUVmax), average (SUVmean), and total (SUVtotal) SUV were extracted from each lesion. Atlas-based segmentation was used to divide each patient skeleton into 25 skeletal regions. Test-retest repeatability of each SUV metric was assessed with coefficient of variation (CV). Results: A total of 265 malignant bone lesions from 18 patients were identified by nuclear medicine physician. The largest proportion of bone lesions were localized to the spine (41%), with 41% of those lesions localized to the thoracic spine. One-way ANOVA showed that measurement differences differed significantly for all three metrics across locations (p<0.01 for each metrics). Overall, CV was smallest for SUVmean at 5.3%, followed by SUVmax at 11.5% and SUVtotal at 20.4%. Lesions in the pubis were consistently the most repeatable (CV(SUVmax)= 5.6%, CV(SUVmean)= 0.6%, CV(SUVtotal)= 2.9%). According to SUVmean, repeatability was poorest in the cervical spine (CV = 6.2%), whereas according to SUVmax and SUVtotal, repeatability was poorest in the ribs (CV(SUVmax)= 15.0%, CV(SUVtotal)= 29.8%). Conclusion: Location of the lesion affects the repeatability of {sup 18}F-NaF PET/CT, with the ribs and cervical spine having the lowest repeatability and the pubis having the highest repeatability. These results can be used to establish location-specific response criteria for NaF PET-based treatment response assessment.

60 APPLIED LIFE SCIENCES↗

Location Generalizer

This software produces general location descriptions from time-series location data collected from mobile devices that record global positioning system (GPS) coordinates over time. The purpose of this software is to convert detailed location history data, which is considered personally identifiable information (PII), into non-traceable, anonymized, generic information that is useful to researchers but does not contain PII. The software is specifically designed for use with trigger-based data that describe the parked locations and dwell times of automobiles.

Smart, John↗

Transcatheter Arterial Chemoembolization for Treatment-Naive Hepatocellular Carcinoma Has Different Treatment Effects Depending on Central or Peripheral Tumor Location

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3–24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3–12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0–12.6) in the central arm and up-to-7 in, and 3.0 months (1.2–4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

Gastroenterology & Hepatology↗

Machine Learning Approach for Spatiotemporal Multivariate Optimization of Environmental Monitoring Sensor Locations

Abstract Long-term environmental monitoring is critical for managing the soil and groundwater at contaminated sites. Recent improvements in state-of-the-art sensor technology, communication networks, and artificial intelligence have created opportunities to modernize this monitoring activity for automated, fast, robust, and predictive monitoring. In such modernization, it is required that sensor locations be optimized to capture the spatiotemporal dynamics of all monitoring variables as well as to make it cost-effective. The legacy monitoring datasets of the target area are important to perform this optimization. In this study, we have developed a machine-learning approach to optimize sensor locations for soil and groundwater monitoring based on ensemble supervised learning and majority voting. For spatial optimization, Gaussian process regression (GPR) is used for spatial interpolation, while the majority voting is applied to accommodate the multivariate temporal dimension. Results show that the algorithms significantly outperform the random selection of the sensor locations for predictive spatiotemporal interpolation. While the method has been applied to a four-dimensional dataset (with two-dimensional space, time, and multiple contaminants), we anticipate that it can be generalizable to higher-dimensional datasets for environmental monitoring sensor location optimization.

Siddiquee, Masudur R.↗

Bacterial community and arsenic functional genes diversity in arsenic contaminated soils from different geographic locations

To understand how soil microbial communities and arsenic (As) functional genes respond to soil arsenic (As) contamination, five soils contaminated with As at different levels were collected from diverse geographic locations, incubated for 54 days under flooded conditions, and examined by both MiSeq sequencing of 16S rRNA gene amplicons and functional gene microarray (GeoChip 4.0). The results showed that both bacterial community structure and As functional gene structure differed among geographical locations. The diversity of As functional genes correlated positively with the diversity of 16S rRNA genes (P< 0.05). Higher diversities of As functional genes and 16S rRNA genes were observed in the soils with higher available As. Soil pH, phosphate-extractable As, and amorphous Fe content were the most important factors in shaping the bacterial community structure and As transformation functional genes. Geographic location was also important in controlling both the bacterial community and As transformation functional potential. These findings provide insights into the variation of As transformation functional genes in soils contaminated with different levels of As at different geographic locations, and the impact of environmental As contamination on the soil bacterial community.

59 BASIC BIOLOGICAL SCIENCES↗

Locating Surface Explosions by Combining Seismic and Infrasound Data

An outline of a Bayesian source location framework for using seismic and acoustic observations is developed and tested on synthetic and real data. Seismic and acoustic phenomena are both commonly used in detection and location of a variety of natural or man–made events, such as volcanic eruptions, quarry blasts, and military exercises. Typically, seismic and acoustic observations have been utilized independently of each other. Here, we outline a Bayesian formulation for combining the two observations in a single estimate of the location and origin time. Using realistic estimates of uncertainty, we subsequently explore how combining the different observation types can benefit event location at local to near–regional distances. We apply the method to synthetic data and to real observations from a mining blast in Bingham Mine in Utah. Our findings suggest that, for relatively sparse or azimuthally limited observations, the relative strengths of the two different phenomenologies enable more precise joint–event localization than either seismic or infrasonic measurements alone.

58 GEOSCIENCES↗

The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions

This brief report describes commissioning measurements performed using a newly constructed fast neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M3FT-13OR0402054, “Imager commissioning and 3D source configuration measurements” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast Neutron Imaging to Quantify Nuclear Materials - ORNL.” In addition to representing the first measurements made with the new device, these measurements also demonstrate for the first time the ability to localize one or more neutron sources in three dimensions by combining imaging data from multiple measurements in which the imager was positioned at different locations. The development and use of fast-neutron imaging technology are motivated by a desire to locate and quantify plutonium holdup in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. Considering the goal of quantitative measurements, fast neutrons (as opposed to the more numerous gamma rays) are preferred in many situations because of their ability to penetrate equipment and nuclear material that are essentially opaque to gamma radiation. However, there are many challenges associated with constructing a practical imager for fast neutrons. For example, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager that is sufficiently compact to be suitable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Moreover, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid, unlike the organic liquid scintillators that are typically used to achieve fast-neutron detection. Last of all, a single-sided measurement geometry, as is typically used in imaging applications, necessitates accurate measurement of the location of a deposit of plutonium holdup in three dimensions in order to correctly infer the source strength. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34. This report presents a description and preliminary analysis of mock holdup measurements intended to determine the three-dimensional location of one or more neutron sources placed in prototypical equipment from a set of imaging measurements that scanned the extent of the equipment.

Hausladen, Paul↗