Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Long-term thermal aging behavior and strength reduction in a laser powder bed fusion 316H stainless steel

The long-term thermal stability of structural alloys is essential for ensuring the safe and reliable operation of nuclear reactors and other power plants. While extensive research has explored the effects of thermal aging on conventional stainless steels, the behavior of additively manufactured (AM) alloys remains less understood. This study examines the thermal aging response of laser powder bed fusion (LPBF) 316H stainless steel (SS) at temperatures ranging from 550 °C to 750 °C over durations of up to 10,000 h (approximately 1.14 years). Advanced characterization techniques, including electron microscopy and synchrotron X-ray diffraction, were used to investigate dislocation recovery and phase evolution. Based on these findings, a time-temperature-precipitation (TTP) diagram was developed for LPBF 316H SS, revealing a 10- to100-fold acceleration in precipitation kinetics compared to wrought 316H SS. A physics-informed model was calibrated using the short-term experimental data, enabling predictions of average precipitate sizes, volume fractions of M 23 C 6 and Laves phases, and changes in molybdenum solute concentration for aging up to 1 × 10⁶ h (114 years). These microstructural insights were further utilized to estimate yield strength and extrapolate strength reduction factors over the extended aging period. Despite the accelerated aging kinetics, LPBF 316H SS demonstrated superior yield strength retention compared to its wrought counterpart. In conclusion, this study establishes a framework for evaluating long-term performance using short-term experimental data and supports the accelerated qualification of AM materials for high-temperature structural applications.

Laser powder bed fusion↗

Benchmarking magnetised three-wave coupling for laser backscattering: analytic solutions and kinetic simulations

Understanding magnetised laser–plasma interactions is important for controlling magneto-inertial fusion experiments and developing magnetically assisted radiation and particle sources. For nanosecond pulses at non-relativistic intensities, interactions are dominated by coherent three-wave interactions, whose nonlinear coupling coefficients became known only recently when waves propagate at oblique angles with the magnetic field. In this paper, backscattering coupling coefficients predicted by warm-fluid theory are benchmarked using particle-in-cell simulations in one spatial dimension, and excellent agreements are found for a wide range of plasma temperatures, magnetic field strengths and laser propagation angles, when the interactions are mediated by electron-dominant hybrid waves. Systematic comparisons between theory and simulations are made possible by a rigorous protocol. On the theory side, the initial boundary value problem of linearised three-wave equations is solved, and the transient-time solutions allow the effects of growth and damping to be distinguished. On the simulation side, parameters are carefully chosen and calibration runs are performed to ensure that comparisons are well controlled. Fitting simulation data to analytical solutions yields numerical growth rates that match theory predictions within error bars. Although warm-fluid theory is found to be valid for a wide parameter range, genuine kinetic effects have also been observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low loss fiber-coupled volumetric interconnects fabricated via direct laser writing

Photonic integrated circuits (PICs) are vital for high-speed data transmission. However, optical routing is limited in PICs composed of only one or a few stacked planes. Further, coupling losses must be low in deployed systems. Previously, we developed the subsurface controllable refractive index via beam exposure (SCRIBE) technique to write accurate 3D gradient refractive index (GRIN) profiles within a mesoporous silica scaffold. Here, we apply SCRIBE to fabricate low loss, broadband, polarization insensitive, fiber-coupled, single-mode volumetric interconnects that include waveguides traversing arbitrary 3D paths. By seamlessly integrating mode-matching subsurface lenses and GRIN waveguide tapers, calibrating for positional writing errors, implementing multipass exposure, automating alignment, and switching to antireflection coated fibers, we reduced the insertion loss for a fiber-PIC-fiber interconnect from 50 to 2.14 dB, or 1.47 dB, excluding the fiber array’s loss. Further, we establish an upper bound of 0.45 dB loss per coupler. We report quality factors of 27,000 and 77,000 and bending losses of 6 and 3 dB/cm for 15 and 30 µm radii microrings, respectively. We also demonstrate Bézier escalators, polarization-rotating and polarization-splitting interconnects, and a seven-channel 25 µm pitch volumetric interconnect. The SCRIBE platform presents a clear path toward realizing 3D PICs with unique functionality.

Optics↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Temperature-dependent mechanical properties and crystal plasticity parameters for additively manufactured Haynes-214 alloy: Experiments and numerical modeling

Our experimental mechanical testing data demonstrated that the additively manufactured (AM) laser powder bed fusion (L-PBF) Haynes-214 alloy exhibits non-linear mechanical properties as the temperature rises from ambient to 870 °C. Crystal plasticity (CP) simulations provide an effective approach to gaining deeper insights into microstructure-property linkages under thermomechanical loading. This method can reduce the need for costly high-temperature mechanical testing while accounting for the effects of crystallographic texture and grain morphology on the mechanical behavior of AM materials. However, calibrating a CP model is time-consuming because individual simulations are computationally expensive and hundreds (or more) of iterations over parameter sets may be required. To address this issue, we have designed a machine learning-differential evolution (ML-DE) CP framework that can accurately interpolate the tensile properties of AM L-PBF Haynes-214 alloy across a wide temperature range from ambient to 870 °C, with minimal reliance on experimental data. The framework uses electron backscatter diffraction (EBSD) measurements to generate statistically equivalent microstructural volume elements to serve as inputs to the CP modeling framework. Stress–strain curves were generated from 1000 CP simulations, which serve as the training data set for the three ML regression algorithms explored: linear, extra-trees, and multi-layer perceptron. These three regression models were independently evaluated to compare their efficiency and identify the most suitable algorithm for the given problem. Results revealed that the extra-trees ML regressor outperforms the other models in both qualitative and quantitative aspects with an R 2 of 0.98. Subsequently, the differential evolution optimization approach is employed to calibrate the ML-based CP material parameters with experimental results obtained at various temperatures. Finally, temperature-dependent CP material parameters are formulated. The effectiveness and efficiency of the designed framework are validated through comparison with experimental results, demonstrating a high degree of agreement. These calibrated parametric constitutive equations enable further use of the CP model to study the deformation behavior of this alloy under a wide range of thermo-mechanical loading conditions.

36 MATERIALS SCIENCE↗

Equation of state of boron carbide B 4 ⁢C

We present the results of recent experiments conducted on the Sandia Z machine and a new tabular equation of state for B 4 ⁢C. The equation of state was calibrated to a combination of density functional calculations reported here and fits to preexisting data. It was constructed partly to recover the effects of a shock-driven, polymorphic phase transition of unknown character beginning at particle velocities of just under 3 km/s (shock pressures of 95 GPa). Some of the Z experiments included sound speeds determined by the overtaking rarefaction method, from which we calculate the Grüneisen parameter and compare with previous experiments conducted at the OMEGA laser [Fratanduono et al ., Phys. Rev. B 94 , 184107 (2016)], our own first principles calculations, and another recent tabular equation of state [Zhang et al ., Phys. Rev. E 102 , 053203 (2020)]. We also compare our results with previous static compression, thermophysical, and melt studies, finding mixed consistency. We predict the onset and completion of shock melting at 225 and 265 GPa, respectively, and predict a melt curve that is largely flat to pressures of several hundred GPa.

36 MATERIALS SCIENCE↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermonuclear performance variability near ignition at the National Ignition Facility

We describe our current understanding of the variability and degradation mechanisms observed through a series of five indirectly driven inertial fusion implosions fielded at the National Ignition Facility in the fall of 2021, four of which attempted to reproduce the first experiment to achieve Lawson's criterion for ignition with a thermonuclear yield of 1.35 MJ on August 8, 2021. A large number of absolutely calibrated (imaging, time-resolved, and spectrally resolved) x-ray and neutron diagnostics are fielded on the NIF along multiple lines of sight for each experiment. This allows for a reconstruction of the DT fuel and ablator mix injected into the hotspot around peak burn. We show that nuclear yield variations are well reproduced by numerical modeling when the measured low mode asymmetries and mix mass are included. Furthermore, these observed perturbations during burn are linked to small variations in laser delivery and capsule defects. Stringent specifications are then set to achieve robust ignition with the implosion design studied in this paper.

Divol, L. (ORCID:0000000269699898)↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The influence of tillage and fertilizer on the flux and source of nitrous oxide with reference to atmospheric variation using laser spectroscopy

Nitrous oxide (N 2 O) is the third most important long-lived greenhouse gas and agriculture is the largest source of N 2 O emissions. Curbing N 2 O emissions requires understanding influences on the flux and sources of N 2 O. We measured flux and evaluated microbial sources of N 2 O using site preference ( S P ; the intramolecular distribution of 15 N in N 2 O) in flux chambers from a grassland tilling and agricultural fertilization experiments and atmosphere. We identified values greater than that of the average atmosphere to reflect nitrification and/or fungal denitrification and those lower than atmosphere as increased denitrification. Our spectroscopic approach was based on an extensive calibration with 18 standards that yielded S P accuracy and reproducibility of 0.7 ‰ and 1.0 ‰, respectively, without preconcentration. Chamber samples from the tilling experiment taken ~ monthly over a year showed a wide range in N 2 O flux (0–1.9 g N 2 O-N ha -1 d -1 ) and S P (- 1.8 to 25.1 ‰). Flux and S P were not influenced by tilling but responded to sampling date. Large fluxes occurred in October and May in no-till when soils were warm and moist and during a spring thaw, an event likely representing release of N 2 O accumulated under snow cover. These high fluxes could not be ascribed to a single microbial process as S P differed among chambers. However, the year-long S P and flux data for no-till showed a slight direct relationship suggesting that nitrification increased with flux. The comparative data in till showed an inverse relationship indicating that high flux events are driven by denitrification. Corn ( Zea mays ) showed high fluxes and S P values indicative of nitrification ~ 4 wk after fertilization with subsequent declines in S P indicating denitrification. Although there was no effect of fertilizer treatment on flux or S P in switchgrass ( Panicum virgatum) , high fluxes occurred ~1 month after fertilization. In both treatments, S P was indicative of denitrification in many instances, but evidence of nitrification/fungal denitrification also prevailed. At 2 m atmospheric N 2 O S P had a range of 31.1 ‰ and 14.6 ‰ in the grassland tilling and agricultural fertilization experiments, respectively. These data suggest the influence of soil microbial processes on atmospheric N 2 O and argue against the use of the global average atmospheric S P in isotopic modeling approaches.

Environmental Sciences & Ecology↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗