Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leaks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Fully Redundant On-Line Mass Spectrometer System Used to Monitor Cryogenic Fuel Leaks on the Space Shuttle

This paper presents an on-line mass spectrometer designed to monitor for cryogenic leaks on the Space Shuttle. The topics include: 1) Hazardous Gas Detection Lab; 2) LASRE Test Support; 3) Background; 4) Location of Systems; 5) Sample Lines for Gas Detection; 6) Problems with Current Systems; 7) Requirements for New System (Nitrogen and Helium Background); and 8) HGDS 2000. This paper is in viewgraph form.

Griffin, T. P.↗

Non-Pyrotechnic Zero-Leak Normally Closed Valve

This valve is designed to create a zero-leak seal in a liquid propulsion system that is a functional replacement for the normally closed pyrovalve. Unlike pyrovalves, Nitinol is actuated by simply heating the material to a certain temperature, called the transition temperature. Like a pyrovalve, before actuation, the upstream and downstream sections are separated from one another and from the external environment by closed welded seals. Also like pyrovalves, after actuation, the propellant or pressurant gas can flow without a significant pressure drop but are still separated from the external environment by a closed welded seal. During manufacture, a Nitinol bar is compressed to 93 percent of its original length and fitted tightly into the valve. During operation, the valve is heated until the Nitinol reaches the transition temperature of 95 C; the Nitinol "remembers" its previous longer shape with a very large recovery force causing it to expand and break the titanium parent metal seal to allow flow. Once open, the valve forever remains open. The first prototype valve was designed for high pressure [5,000 psi (=34.5 MPa)] and low flow, typical requirements for pressurant gas valves in liquid propulsion systems. It is possible to modify the dimensions to make low-pressure models or high-flow models, for use downstream of the propellant tanks. This design is simpler, lower risk, and less expensive than the pyrovalve. Although the valve must be in a thermally controlled state (kept below 80 C) to prevent premature actuation, the pyrovalves and electrically actuated initiators have far more taxing handling requirements.

Gillespie, Rebecca↗

Hydrogen Leak Detection Sensor Database

This slide presentation reviews the characteristics of the Hydrogen Sensor database. The database is the result of NASA's continuing interest in and improvement of its ability to detect and assess gas leaks in space applications. The database specifics and a snapshot of an entry in the database are reviewed. Attempts were made to determine the applicability of each of the 65 sensors for ground and/or vehicle use.

Baker, Barton D.↗

Compact Instruments Measure Helium-Leak Rates

Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.

Stout, Stephen↗

Investigation of the Leak Response of a Carbon-Fiber Laminate Loaded in Biaxial Tension

Designers of pressurized structures have been reluctant to use composite materials because of concerns over leakage. Biaxial stress states are expected to be the worst-case loading condition for allowing leakage to occur through microcracks. To investigate the leakage behavior under in-plane biaxial loading, a cruciform composite specimen was designed that would have a relatively large test section with a uniform 1:1 biaxial loading ratio. A 7.6-cm-square test section was desired for future investigations of the leakage response as a result of impact damage. Many iterations of the cruciform specimen were evaluated using finite element analysis to reduce stress concentrations and maximize the size of the uniform biaxial strain field. The final design allowed the specimen to go to relatively high biaxial strain levels without incurring damage away from the test section. The specimen was designed and manufactured using carbon/epoxy fabric with a four-ply-thick, quasi-isotropic, central test section. Initial validation and testing were performed on a specimen without impact damage. The specimen was tested to maximum biaxial strains of approximately 4500micro epsilon without apparent damage. A leak measurement system containing a pressurized cavity was clamped to the test section and used to measure the flow rate through the specimen. The leakage behavior of the specimen was investigated for pressure differences up to 172 kPa

Jackson, Wade C.↗

Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

Ramspacher, Daniel J.↗

Columbus IFHX Ammonia Leak Analysis

After the Columbus Moderate Temperature Loop (MTL) InterFace Heat eXchanger (IFHX) low temperature event of GMT 345-2013, NASA investigated relevant transient scenarios involving IFHX rupture after water freezing and subsequent thawing. NASA recommended development of a Fault Detection Isolation and Recovery (FDIR) plan that would, in the event of a heat exchanger freeze event, close the Water On/Off Valves (WOOVs) to isolate the heat exchanger and prevent ammonia from the external flow loops from spreading into the cabin. NASA performed a preliminary simplified analysis for the reference case of IFHX rupture, but for a deeper understanding TAS developed detailed SINDA-FLUINT models of the Columbus ITCS that were built and run through the SINAPS GUI. This allowed simulation of the ammonia leakage physics including the variation of environmental parameters, thus providing more accurate and specific input to the FDIR under development. The result was finalization of the IFHX WOOVs closure sequence and wait times to contain the ammonia propagation to Columbus and allow identification of the leaking IFHX. In addition, the analysis results provided reference pressure profiles to be used on console and by the Engineering as support for the telemetry data assessment in case of failure.This paper gives an overview on the issue and focuses on the analytical aspects of the multiphase fluid dynamics involved.

Tilloca, A.↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

The NREL Sensor Laboratory: Hydrogen Leak Detection for Large Scale Deployments: Preprint

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for sensor developers, end-users, and regulatory agencies within the national and international hydrogen community. The Laboratory continues to provide as its core capability the unbiased verification of hydrogen sensor performance to assure sensor availability and their proper use. However, the mission and strategy of the NREL Sensor Laboratory has evolved to meet the needs of the growing hydrogen market. The Sensor Laboratory program has expanded to support research in conventional and alternative detection methods as hydrogen use expands to large-scale markets as envisioned by the DOE National Clean Hydrogen Strategy and Roadmap. Current research encompasses advanced methods of hydrogen leak detection including stand-off and wide area monitoring approaches for large scale and distributed applications. In addition to safety applications, low-level detection strategies to support the potential environmental impacts of hydrogen and hydrogen product losses along the value chain are being explored. Many of these applications utilize detection strategies that supplement and may supplant the use of traditional point sensors. The latest results of the hydrogen detection strategy research at NREL will be presented.

detection↗

Methane Mitigation Using Linear Motor Leak Recovery Compressor

GTI Energy (GTI), in collaboration with The University of Texas at Austin - Center for Electromechanics (UT‑CEM), designed, fabricated, and tested a linear motor–driven compressor intended to mitigate methane emissions at natural gas facilities across transmission, storage, gathering, and processing sectors of the gas value chain.

02 PETROLEUM↗