Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Reliability Evaluation of Base-Metal-Electrode (BME) Multilayer Ceramic Capacitors for Space Applications

This paper reports reliability evaluation of BME ceramic capacitors for possible high reliability space-level applications. The study is focused on the construction and microstructure of BME capacitors and their impacts on the capacitor life reliability. First, the examinations of the construction and microstructure of commercial-off-the-shelf (COTS) BME capacitors show great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and approximately 0.5 micrometers, which is much less than that of most PME capacitors. The primary reasons that a BME capacitor can be fabricated with more internal electrode layers and less dielectric layer thickness is that it has a fine-grained microstructure and does not shrink much during ceramic sintering. This results in the BME capacitors a very high volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT) and regular life testing as per MIL-PRF-123. Most BME capacitors were found to fail· with an early dielectric wearout, followed by a rapid wearout failure mode during the HALT test. When most of the early wearout failures were removed, BME capacitors exhibited a minimum mean time-to-failure of more than 10(exp 5) years. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically between 10 and 20. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. Since BME capacitors have a much smaller grain size than PME capacitors, it is reasonable to predict that BME capacitors with thinner dielectric layers may have an equivalent life expectancy to that of PME capacitors with thicker dielectric layers.

Liu, David (Donghang)↗

The Effect of 1–10-MeV Neutrons on the JESD89 Test Standard

Here, the JESD89 test standard defines how terrestrial neutron testing is conducted [1] . The test standard covers a number of different types of radiation used for testing, including protons, neutrons, and alphas, and different types of testing, including life testing and accelerated testing. Broad-spectrum neutron testing is the most common type of accelerated radiation testing for the terrestrial radiation environment. Unlike most test standards, the JESD89 defines the minimum energy for determining the cumulative fluence for the deployed and test environment. Currently, the minimum energy is set at 10 MeV. As the test standard is currently being rewritten, changing the minimum energy to 1 MeV is being explored, because it is believed that the onset to neutron-induced single-event effects (SEEs) is less than 10 MeV. There are three separate problems with lowering the minimum energy: determining whether electronics have a sensitivity to neutron-induced SEEs below 10 MeV, determining whether the test spectra match the terrestrial environment in the 1–10-MeV range, and the measurement error caused by not including the fluence from 1 to 10 MeV. In this paper, we present information on these factors and whether the minimum energy should be lowered to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Star tracker for the Apollo telescope mount

The star tracker for the Apollo Telescope Mount (ATM) has been designed specifically to meet the requirements of the Skylab vehicle and mission. The functions of the star tracker are presented, as well as descriptions of the optical-mechanical assembly (OMA) and the star tracker electronics (STE). Also included are the electronic and mechanical specifications, interface and operational requirements, support equipment and test requirements, and occultation information. Laboratory functional tests, environmental qualification tests, and life tests have provided a high confidence factor in the performance of the star tracker in the laboratory and on the Skylab mission.

Lee, C. E.↗

The Space Shuttle's testing gauntlet

The Space Shuttle verification program is detailed, with verification network flowcharts. Performance qualification tests, life endurance tests, structural verification tests, and vibration/dynamic tests of components, subsystems, and major systems at various test levels are dealt with. Ground tests, static firings of the Shuttle main engine, external-tank separation tests, ground vibration tests of vehicle mated to external tank, and main propulsion tests and test scheduling are described. Functions of the Shuttle avionics integration laboratory and electronic systems test laboratory are discussed. Test preparations and procedures for orbital flight testing, launch pad tests, and Shuttle approach- and landing-tests are described.

Mcintosh, G. P.↗

Long term behavior of silicon germanium thermoelectric generators

Results of tests of the long term performance of SiGe radioisotope thermoelectric generators (RTG) are presented. Three modules were monitored for 17,000-32,300 hr at hot junction temperatures of 1,085, 1,055, and 1,000 C; coating the unicouples with a 12,000 A thick layer of Si3N4 protected the modules from Si sublimation. Output degraded less than 0.3-0.4%/1,000 hr over the testing period. Life tests on a multihundredwatt (MHW) SiGe generator with 312 couples at a hot shoe temperature of 1,040 C dealt with power of 150 W at 30 V, with 0.5%/1,000 hr performance degradation. Si deposition on the insulation was found to enhance electrical conductance until a saturation point was reached. Disassembly of a test module after 16,750 hr revealed a Mo build-up, SiN4 coating deterioration, and Ti diffustion from the hot shoe to cooler regions of the junction. The presence of an Al2O3 insulator was recognized as preventing coating loss. Performance records from the Voyager and Les-8 satellites' RTG's are compared and show similar, 0.25%/1,000 hr degradation rates; RTG storage is judged to be feasible and the tests lead to projections of a 600,000 hr lifetime for a SiGe RTG.

Shields, V.↗

Design of a mirror pointing and occulting mechanism for the Ultraviolet Coronagraph Spectrometer (UVCS)

The Mirror and Occulter Mechanism (MOM), a lightweight stable optical assembly which is a critical component to the Ultraviolet Coronagraph Spectrometer to be flown on the European SOHO spacecraft, is discussed. The MOM combines the functions of precision mirror pointing and occultation of stray light into a single package. The mirror mechanism and occulter mechanism designs are described and development testing and life testing activities are discussed.

Highman, Clifton O.↗

Lunar-Mars Life Support Test Project: Human Factors and Crew Interactions - Phase 2

Phase 2 of the Lunar-Mars Life Support Test Project was conducted in June and July of 1996 at the NASA Johnson Space Center. The primary objective of Phase 2 was to demonstrate and evaluate an integrated physicochemical air revitalization and regenerative water recovery system capable of sustaining a human crew of four for 30 days inside a closed chamber. The crew (3 males and 1 female) was continuously present inside a chamber throughout the 30-day test. The objective of this paper was to describe crew interactions and human factors for the test. Crew preparations for the test included training and familiarization of chamber systems and accommodations, and medical and psychological evaluations. During the test, crew members provided metabolic loads for the life support systems, performed maintenance on chamber systems, and evaluated human factors inside the chamber. Overall, the four crew members found the chamber to be comfortable for the 30-day test. The crew performed well together and this was attributed in part to team dynamics, skill mix (one commander, two system experts, and one logistics lead), and a complementary mix of personalities. Communication with and support by family, friends, and colleagues were identified as important contributors to the high morale of the crew during the test. Lessons learned and recommendations for future testing are presented by the crew in this paper.

Ming, D. W.↗

Technology development and demonstration of a low thrust resistojet thruster

Three thrusters were fabricated to definitized thruster drawings using new rhenium vapor deposition technology. Two of the thrusters were operated using ammonia as propellant and one was operated using hydrogen propellant for performance determination. All demonstrated consistent operational specific impulse performance while demonstrating thermal performance better than the development units from which they evolved. Two of the thrusters were subjected to environmental structural testing including vibration, acceleration and shock loading to specifications. Both of the thrusters subjected to the environmental tests passed all required tests. The third, spare, thruster was introduced into the life test portion of the program. Two thrusters were then subjected to a life cycling test program under typical spacecraft operating power levels. During the life test sequence, the hydrogen thruster accrued 720 operating life test cycles, more than 370 on-off cycles and 365 hours of powered up time. The ammonia accrued approximately 380 on-off cycles and 392.2 on time hours of operation during the 720 cycling hour test. Both thrusters completed the scheduled operational life test in reasonably good condition, structurally integral and capable of indefinite further operation.

Pfeifer, G. R.↗

Modelling a nickel-cadmium battery as a heterogeneous device

A common failure mode for nickel-cadmium batteries involves a nonuniform degradation of the performance of individual cells. This behavior is manifested as a divergence in voltage during cyclic operation. An empirically based performance model is presented which simulates a battery composed of heterogeneous cells. Battery performance is studied as a function of the distribution of cell performance characteristics. The technique has successfully predicted cell voltage divergence behavior observed during cycle life testing. It is noted that this work enhances understanding of life-test results and may improve life-test design and data analysis.

Glueck, Peter R.↗

Protocol Development for the NASA-JSC Lunar-Mars Life Support Test Project (LMLSTP) Phase 3 Project: A Report on Baseline Studies at KSC for Continuous Salad Production

The Phase 3 Lunar-Mars Life Support Test Project (LMLSTP) was conducted in a 20-foot chamber at Johnson Space Center. The overall objective of the Phase 3 project was to conduct a 90-day regenerative life support system test involving 4 human subjects to demonstrate an integrated biological and physicochemical life support system. A secondary objective of the Phase 3 LMLSTP was to demonstrate the ability to produce salad-type vegetable by integration of a small benchtop growth chamber located within the crew habitat area. This small chamber, commercially manufactured as the Controlled Environment Research Ecosystem (CERES 2010(TM)), functioned as a means to continuously provide fresh lettuce crops for crew members. The CERES 2010(TM) growth chamber utilized hardware components developed for effective plant biomass production in spaceflight applications. These components included: (1) LED lighting; (2) Astroculture(TM) Root Trays; and (3) Zeoponic media. In planning for the LMLSTP Phase 3, a request was put forward for KSC scientists to generate a protocol for successful continuous planting, culturing, and harvesting of the salad-crop, lettuce. By conducting baseline tests with components of the CERES 2010(TM), a protocol was developed.

Goins, G. D.↗

Space-and Ground-Based Non-Accelerated Long Lifetime Data for Ruggedized Commercial Non-Planar Ring Oscillator (NPRO) Lasers

Lifetime data is presented for ruggedized commercial NPRO lasers used in the Tropospheric Emission Spectrometer (TES) Instrument on NASA’s Aura Earth-orbiting spacecraft, including 20 years of data from two life test units on the ground, 12 years of on-orbit data from TES Laser A, and 2 years of on-orbit data from TES Laser B. The TES lasers are diode-pumped Non-Planar Ring Oscillator (NPRO) lasers using Nd:YAG crystals. Since accelerated life testing was not possible on the complete laser, early prototype lasers that had gone through thermal cycling and vibration testing were placed on non-accelerated life tests with the hope of gathering at least a couple of years of data before launch. Long-term lifetime data for hybrid laser systems in space applications is not abundant, and out of necessity, accelerated reliability testing is usually done over a relatively short time with a large number of devices. The data presented in this paper is unique as it tracks the optical power output over time of a total of four lasers on the order of decades rather than months or years. Two of the lasers have each been on life test for over 20 years on the ground and are still operating, and the other two lasers have been on-orbit for 14 years. TES Laser A was still operating when the TES Instrument was decommissioned in January 2018. Therefore, the data presented covers over 450,000 non-accelerated device-hours, with 23% of those hours being in space.

Kane, T.J.↗

An Overview of Long Duration Sodium Heat Pipe Tests

High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.

Rosenfeld, John H.↗

Out-of-core Evaluations of Uranium Nitride-fueled Converters

Two uranium nitride fueled converters were tested parametrically for their initial characterization and are currently being life-tested out of core. Test method being employed for the parametric and the diagnostic measurements during the life tests, and test results are presented. One converter with a rhenium emitter had an initial output power density of 6.9 W/ sq cm at the black body emitter temperature of 1900 K. The power density remained unchanged for the first 1000 hr of life test but degraded nearly 50% percent during the following 1000 hr. Electrode work function measurements indicated that the uranium fuel was diffusing out of the emitter clad of 0.635 mm. The other converter with a tungsten emitter had an initial output power density of 2.2 W/ sq cm at 1900 K with a power density of 3.9 W/sq cm at 4300 h. The power density suddenly degraded within 20 hr to practically zero output at 4735 hr.

Shimada, K.↗

Endurance cycling results in extreme environments

A new test bed for life testing flash memories in extreme environments is introducted. the test bed is based on a state-of-the-art development board. Since space applications often desire state-of-the-art devices, such a basis seems appropriate. Comparison of this tester to other such systems, including those with data presented here in the past is made. Limitations of different testers for varying applications are discussed. Recently developed data, using this test bed is also presented.

microelectronics↗

IVGEN Post Flight Analysis

The Intravenous Fluid Generation (IVGEN) Experiment was a technology demonstration experiment that purified ISS potable water, mixed it with salt, and transferred it through a sterilizing filter. On-orbit performance was verified as appropriate and two 1.5 l bags of normal saline solution were returned to earth for post-flight testing by a FDA certified laboratory for compliance with United States Pharmacopiea (USP) standards. Salt concentration deviated from required values and an analysis identified probable causes. Current efforts are focused on Total Organic Content (TOC) testing, and shelf life.The Intravenous Fluid Generation (IVGEN) Experiment demonstrated the purification of ISS potable water, the mixing of the purified water with sodium chloride, and sterilization of the solution via membrane filtration. On-orbit performance was monitored where feasible and two 1.5-liter bags of normal saline solution were returned to earth for post-flight testing by a FDA-registered laboratory for compliance with United States Pharmacopeia (USP)standards [1]. Current efforts have been focused on challenge testing with identified [2] impurities (total organic-carbon), and shelf life testing. The challenge testing flowed known concentrations of contaminants through the IVGEN deionizing cartridge and membrane filters to test their effectiveness. One finding was that the filters and DI-resin themselves contribute to the contaminant load during initial startup, suggesting that the first 100 ml of fluid be discarded. Shelf life testing is ongoing and involves periodic testing of stored DI cartridges and membrane filters that are capped and sealed in hermetic packages. The testing is conducted at six month intervals measuring conductivity and endotoxins in the effluent. Currently, the packaging technique has been successfully demonstrated for one year of storage testing. The USP standards specifies that the TOC be conducted at point of generation as opposed to point of consumption. Samples were generated and shipped to an FDA facility however, testing determined that the samples failed the TOC specification with most likely due to leaching from the sample container. Shelf life testing is examining packaging techniques and periodic testing of samples of DI cartridges that are capped and sealed in hermetic packages. Periodic testing of the purified water output will be conducted at six month intervals.

microgravity applications↗

Development of an Accelerated Test Design for Predicting the Service Life of the Solar Array at Mead, Nebraska

An accelerated life test is described which was developed to predict the life of the 25 kW photovoltaic array installed near Mead, Nebraska. A quantitative model for accelerating testing using multiple environmental stresses was used to develop the test design. The model accounts for the effects of thermal stress by a relation of the Arrhenius form. This relation was then corrected for the effects of nonthermal environmental stresses, such as relative humidity, atmospheric pollutants, and ultraviolet radiation. The correction factors for the nonthermal stresses included temperature-dependent exponents to account for the effects of interactions between thermal and nonthermal stresses on the rate of degradation of power output. The test conditions, measurements, and data analyses for the accelerated tests are presented. Constant-temperature, cyclic-temperature, and UV types of tests are specified, incorporating selected levels of relative humidity and chemical contamination and an imposed forward-bias current and static electric field.

Gaines, G. B.↗