Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Lithium Loaded Glass Fiber Neutron Detector Tests

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of the lithium-loaded glass fibers option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a small system manufactured by Nucsafe (Oak Ridge, TN).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Separating and Stabilizing Phosphate from High-Level Radioactive Waste: Process Development and Spectroscopic Monitoring

Removing phosphate from alkaline high-level waste sludges at the Department of Energy's Hanford Site in Washington State is necessary to increase the waste loading in the borosilicate glass waste form that will be used to immobilize the highly radioactive fraction of these wastes. We are developing a process which first leaches phosphate from the high-level waste solids with aqueous sodium hydroxide, and then isolates the phosphate by precipitation with calcium oxide. Tests with actual tank waste confirmed that this process is an effective method of phosphate removal from the sludge and offers an additional option for managing the phosphorus in the Hanford tank waste solids. The presence of vibrationally active species, such as nitrate and phosphate ions, in the tank waste processing streams makes the phosphate removal process an ideal candidate for monitoring by Raman or infrared spectroscopic means. As a proof-of-principle demonstration, Raman and Fourier transform infrared (FTIR) spectra were acquired for all phases during a test of the process with actual tank waste. Quantitative determination of phosphate, nitrate, and sulfate in the liquid phases was achieved by Raman spectroscopy, demonstrating the applicability of Raman spectroscopy for the monitoring of these species in the tank waste process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microseismic Monitoring of Laboratory Hydraulic Fracturing Experiments in Granitic Rocks for Different Fracture Propagation Regimes

While hydraulic fracturing (HF) is a widely employed process, the underlying fracturing processes are still heavily contested. The attributes of the HF generated fracture network can exhibit substantial variation when dealing with specific HF propagation regimes encountered in the field. In this study, HF experiments were performed on true-triaxially loaded Barre granite cubes, with microseismic monitoring, to identify and characterize the fracturing mechanisms associated with different viscosity injection fluids. Utilizing fluids with high (oil/1450 cP) and low (water/1 cP) viscosity represented two key HF propagation regimes: viscosity- and toughness-dominated. The experiments conducted with oil involved higher breakdown pressures, larger fluid volumes, and slower fracture propagation speeds. Furthermore, the frequency–magnitude distribution (b value) for all experiments (1.9–2.3) was similar to those encountered for large-scale operations. Slightly larger b values were encountered during the initiation phase (2.4–2.7) relative to the fracture propagation and post-fracturing phases (1.9–2.2). Techniques such as polarity and moment-tensor inversion were utilized to characterize the source mechanisms. For the HF experiments with oil, tensile fractures were most dominant (92%) in the initiation phase compared to fracture propagation and post-fracturing phases (70–75%). Similar tensile fracturing dominancy was not observed with water, attributable to fluid permeation and leak-off. Regardless of the injection fluid or classification criteria employed, tensile fractures were the dominant type consistently, with fewer occurring in water experiments but the specific ratio of crack types varied with different source mechanism criteria employed.

58 GEOSCIENCES↗

Autonomous grain combine control system

A system for controlling a grain combine having a rotor/cylinder, a sieve, a fan, a concave, a feeder, a header, an engine, and a control system. The feeder of the grain combine is engaged and the header is lowered. A separator loss target, engine load target, and a sieve loss target are selected. Grain is harvested with the lowered header passing the grain through the engaged feeder. Separator loss, sieve loss, engine load and ground speed of the grain combine are continuously monitored during the harvesting. If the monitored separator loss exceeds the selected separator loss target, the speed of the rotor/cylinder, the concave setting, the engine load target, or a combination thereof is adjusted. If the monitored sieve loss exceeds the selected sieve loss target, the speed of the fan, the size of the sieve openings, or the engine load target is adjusted.

Hoskinson, Reed L.↗

ProgLIMI: Programmable LInk Metric Identification in Software-Defined Networks

In this paper, we propose the Programmable LInk Metric Identification (ProgLIMI) infrastructure for software-defined networking (SDN) networks. ProgLIMI identifies round-trip link metrics (RTLMs) from accumulated end-to-end metrics of selected measurement paths by leveraging the flexible routing control capability of SDN networks. ProgLIMI mainly solves three sub-problems: (1) monitor placement; (2) linearly independent measurement path construction; and (3) flow rule design. To reduce measurement cost, ProgLIMI tries to minimize the number of required monitors and flow rules. In this paper, we address the three sub-problems for both full and hybrid SDN networks. For full SDN networks, ProgLIMI can achieve full RTLM identification using only one monitor and two flow rules in each SDN switch. In contrast, the RTLM identification in hybrid SDN networks is more complicated due to the routing constraint of hybrid SDN networks. We first prove that the monitor placement problem in hybrid SDN networks is NP-hard. We then formulate the monitor placement and measurement path selection problem in hybrid SDN networks and propose a greedy heuristic algorithm to solve the problem efficiently. Our evaluations on both physical testbed and simulation platform reveal that ProgLIMI can accurately identify the RTLMs (delay and loss rate). Besides, ProgLIMI is also resource efficient, i.e., it only requires two flow rules in each SDN switch and a small number of monitors, and the extra probing traffic load incurred by ProgLIMI is also low.

97 MATHEMATICS AND COMPUTING↗

COVID-19 trends at the University of Tennessee: predictive insights from raw sewage SARS-CoV-2 detection and evaluation and PMMoV as an indicator for human waste

Wastewater-based epidemiology (WBE) has become a valuable tool for monitoring the prevalence of SARS-CoV-2 on university campuses. However, concerns about effectiveness of raw sewage as a COVID-19 early warning system still exist, and it’s not clear how useful normalization by simultaneous comparison of Pepper Mild Mottle Virus (PMMoV) is in addressing variations resulting from fecal discharge dilution. This study aims to contribute insights into these aspects by conducting an academic-year field trial at the student residences on the University of Tennessee, Knoxville campus, raw sewage. This was done to investigate the correlations between SARS-CoV-2 RNA load, both with and without PMMoV normalization, and various parameters, including active COVID-19 cases, self-isolations, and their combination among all student residents. Significant positive correlations between SARS-CoV-2 RNA load a week prior, during the monitoring week, and the subsequent week with active cases. Despite these correlations, normalization by PMMoV does not enhance these associations. These findings suggest the potential utility of SARS-CoV-2 RNA load as an early warning indicator and provide valuable insights into the application and limitations of WBE for COVID-19 surveillance specifically within the context of raw sewage on university campuses.

60 APPLIED LIFE SCIENCES↗

High Frequency Monitoring and Nitrate Sourcing Reveals Baseflow and Stormflow Controls on Total Dissolved Nitrogen and Carbon Export Along a Rural‐Urban Gradient

Abstract Efforts to reduce nitrogen and carbon loading from developed watersheds typically target specific flows or sources, but across gradients in development intensity there is no consensus on the contribution of different flows to total loading or sources of nitrogen export. This information is vital to optimize management strategies leveraging source reductions, stormwater controls, and restorations. We investigate how solute loading and sources vary across flows and land‐use using high frequency monitoring and stable nitrate isotope analysis from five catchments with different sanitary infrastructure, along a gradient in development intensity. High frequency monitoring allowed estimation of annual loading and attribution to storm versus baseflows. Nitrate loads were 16 kg/km 2 /yr. from the forested catchment and ranged from 68 to 119 kg/km 2 /yr., across developed catchments, highest for the septic served site. Across developed catchments, baseflow contributions ranged from 40% of N loading to 75% from the septic served catchment, and the contribution from high stormflows increased with development intensity. Stormflows mobilized and mixed many surface and subsurface nitrate sources while baseflow nitrate was dominated by fewer sources which varied by catchment (soil, wastewater, or fertilizer). To help inform future sampling designs, we demonstrate that grab sampling and targeted storm sampling would likely fail to accurately predict annual loadings within the study period. The dominant baseflow loads and subsurface stormflows are not treated by surface water management practices primarily targeted to surface stormflows. Using a balance of green and gray infrastructure and stream/riparian restoration may target specific flow paths and improve management.

Delesantro, Joseph M.↗

A gas-loading system for LANL two-stage gas guns

A novel gas loading system was designed for the specific application of remotely loading high purity gases into targets for gas-gun driven plate impact experiments. The high purity gases are loaded into well-defined target configurations to obtain Hugoniot states in the gas phase at greater than ambient pressures.The small volume of the gas samples is challenging, as slight changing in the ambient temperature result in measurable pressure changes. Therefore, the ability to load a gas gun target and continually monitor the sample pressure prior to firing provides the most stable and reliable target fielding approach. We present the design and evaluation of a gas loading system built for the LANL 50 mm bore two-stage light gas gun. Targets for the gun are made of 6061 Al or OFHC Cu, and assembled to form a gas containment cell with a volume of approximately 1.38 cc. The compatibility of materials was a major consideration in the design of the system, particularly for its use with corrosive gases. Piping and valves are stainless steel with wetted seals made from Kalrez® and Teflon®. Preliminary testing was completed to ensure proper flow rate and that the proper safety controls were in place. The system has been used to successfully load Ar, Kr, Xe, and anhydrous ammonia with purities of up to 99.999 percent. The design of the system and example data from the plate impact experiments will be shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron Dosimetry for the GE Hitachi 16-10393 Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work (SOW) No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the GE Hitachi 16-10393 irradiation which was conducted in positions B11 of the ATR. Three other irradiations included in the SOW will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the GE Hitachi assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis. The measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the CSM assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 12 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Boise State University JW 15-8242 Irradiation in ATR (Rev.1)

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the Boise State University (BSU) JW 15-8242 irradiations which were conducted in positions A6, A7 and A8 of the ATR. We previously reported data for this experiment after about 1 dpa in a report issued in January 2021 (1). This report is for longer irradiations to about 3 dpa. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the BSU assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ monitoring of dislocation, twinning, and detwinning modes in an extruded magnesium alloy under cyclic loading conditions

This work investigates the microscopic deformation mechanisms of an extruded, precipitation-strengthened AZ80 magnesium (Mg) alloy subjected to strain-controlled low-cycle fatigue using in situ neutron diffraction measurements. Results demonstrate that the plastic deformation during cyclic loading is dominated by the alternating {10.2} extension twinning and detwinning mechanisms. The observed deformation mode is strongly texture and precipitate dependent. For the initial texture, the tested material has two major texture components which result in the occurrence of extension twinning during both compression and reverse tension in the first two cycles. The prolonged detwinning process in the following cycles is proposed to relieve the shear stress field of {00.2} grains, leading to the disappearance of twinning. The precipitation strengthening results in an increase of the critical resolved shear stress (CRSS) by similar to 33 MPa for the extension twinning in this AZ80 alloy. Here, the synergistic effects of the initial texture, precipitation strengthening, and load sharing of various grain families and phases contribute to the complicated evolution of dominant deformation mechanisms, among which elevated dislocation activities are believed to be responsible for the relatively poor low-cycle-fatigue lifetime when compared to other Mg alloys.

36 MATERIALS SCIENCE↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A digital twin based on OpenFAST linearizations for real-time load and fatigue estimation of land-based turbines

Monitoring a wind turbine requires intensive instrumentation, which would be too cost-prohibitive to deploy to an entire wind plant. This work presents a technique that uses readily available measurements to estimate signals that would otherwise require additional instrumentation. This study presents a digital twin concept with a focus on estimating wind speed, thrust, torque, tower-top position, and loads in the tower using supervisory control and data acquisition (SCADA) measurements. The model combines a linear state-space model obtained using OpenFAST linearizations, a wind speed estimator, and a Kalman filter algorithm that integrates measurements with the state model to perform state estimations. The measurements are: top acceleration, generator torque, pitch, and rotational speed. The article extends previous work that derived the linear state-space model using a different method. The new implementation, based on OpenFAST linearization capability, allows for a systematic extension of the method to more states, inputs, outputs, and to the offshore environment. Results from the two methods are compared, and the validation is made with additional measurements using the GE 1.5-MW turbine located at the National Renewable Energy Laboratory test site. Real-time damage equivalent loads of the tower bottom moment are estimated with an average accuracy of approximately 10%. Overall, the results from this proof of concept are encouraging, and further application of the model will be considered.

17 WIND ENERGY↗

Creation of Laboratory-scale Testbed for Autonomous Monitoring and Control of Subsurface Systems

This report describes the results of an LDRD project aiming to develop a laboratory-scale testbed for autonomous subsurface monitoring and control systems. Modifications were made to an existing polyaxial loading frame to incorporate electrical resistivity tomography (ERT) and acoustic emission (AE) monitoring systems. This allows engineered subsurface processes to be studied under realistic temperatures and stresses in a scaled-down laboratory environment with similar monitoring systems as are deployed in field-scale systems. The paper outlines some challenges that were faced in implementing the ERT system at the laboratory scale and the solutions that were devised. Results are shown from two demonstration tests—one focusing on the ERT system, and one focusing on the AE system.

42 ENGINEERING↗