At least 271 records · Page 15

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

A BI-LEVEL APPROACH TO FUTURE POWER SYSTEM CO-OPTIMIZATION WITH HIGH PENETRATION OF RENEWABLE ENERGY AND RESPONSIVE DEMAND

Electricity generation accounts for nearly half of the total CO2 emissions in the United States. For this reason, the development and integration of renewable resources will play an essential role in achieving the societal objective of mitigating climate change through reduction of greenhouse gas emissions. In conjunction with the environmental benefits of renewable energy, the most common renewable sources, such as wind and solar, also increase the uncertainties surrounding generation in power systems, which adds significant challenges to the system operation and planning. The uncertainties and forecasting errors surrounding renewable generation are normally addressed through the use of reserves from traditional generators. At greater levels of renewable penetration, sufficient generator reserves may not be available or economically viable. In contrast, the promise of demand-side resources in this arena lies in the spatially widespread availability, rapid response potential, and lower cost of features that already exist in the system. However, the challenge of responsive demand arises from the need to understand, manage, and incentivize a very large number of resources to participate effectively in efficient operation of the complex power system. Since demand response comes from the distribution system, microgrids as the basic building blocks of future distribution systems will be a critical environment for the study of demand response. To support integration of microgrids with flexible loads in future power systems, the operational mode of power systems will need to evolve. Therefore, it is going to be critical to have new and efficient co-optimization methods for coordination of the various power market participants and the scheduling of resources in the power systems of the future. Motivated by the rapid increase in renewable penetration, the need for effective demand response programs, and a changing system structure, this dissertation seeks to define a new strategy that supports co-optimization of various participants in power systems with emphasis on high renewable penetration and demand response. This strategy has three components; 1) an exploration of the capabilities of different types of demand response programs in a microgrid, 2) development and implementation of a bi-level framework for co-optimization of the main grid with high renewable penetration and a microgrid with demand response capabilities, and 3) expansion of the bi-level framework from a microgrid to a general distribution system to explore the advantages of the bi-level co-optimization approach over the traditional optimization approach. Conclusions of this work illustrate that the stochastic rolling horizon approach could effectively manage the operation of a microgrid with various demand response programs. In addition, the bi-level approach is a promising co-optimization framework for the transmission and distribution levels that could increase system renewable penetration and reduce operation costs. Compared to the traditional framework, the bi-level framework yields more equitable cost sharing patterns among the market participants as well as better support for the power system evolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Expert Elicitation on Wind Farm Control

Wind farm control is an active and growing field of research in which the control actions of individual turbines in a farm are coordinated, accounting for inter-turbine aerodynamic interaction, to improve the overall performance of the wind farm and to reduce costs. The primary objectives of wind farm control include increasing power production, reducing turbine loads, and providing electricity grid support services. Additional objectives include improving reliability or reducing external impacts to the environment and communities. In 2019, a European research project (FarmConners) was started with the main goal of providing an overview of the state-of-the-art in wind farm control, identifying consensus of research findings, data sets, and best practices, providing a summary of the main research challenges, and establishing a roadmap on how to address these challenges. Complementary to the FarmConners project, an IEA Wind Topical Expert Meeting (TEM) and two rounds of surveys among experts were performed. From these events we can clearly identify an interest in more public validation campaigns. Additionally, a deeper understanding of the mechanical loads and the uncertainties concerning the effectiveness of wind farm control are considered two major research gaps.

17 WIND ENERGY↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources: Preprint

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfil their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

distributed energy resource↗

Runaway electron-induced plasma facing component damagein tokamaks

This Roadmap article addresses the critical and multifaceted challenge of plasma facing component (PFC) damage caused by runaway electrons (REs) in tokamaks, a phenomenon that poses a significant threat to the viability and longevity of future fusion reactors such as ITER and DEMO. The dramatically increased RE production expected in future high-current tokamaks makes it very difficult to avoid or mitigate REs in such devices when a plasma discharge terminates abnormally. Preventing damage from the intense localised heat loads they can cause requires a holistic approach that considers plasma, REs and PFC damage. Despite decades of progress in understanding the physics of REs and the thermomechanical response of PFCs separately, their complex interplay remains poorly understood. This document aims to initiate a coordinated, interdisciplinary approach to bridge this gap by reviewing experimental evidence, advancing diagnostic capabilities, and improving modelling tools across different scales, dimensionalities, and fidelities. Key topics include RE beam formation and transport, damage mechanisms in both brittle and metallic PFCs, and observed effects in major facilities such as JET, DIII-D, WEST and EAST. The Roadmap emphasises the urgency of predictive, high-fidelity modelling validated against well-diagnosed controlled experiments, particularly in the light of recent changes in ITER’s wall material strategy and the growing importance of private sector fusion initiatives. Each section of the Roadmap article is written to provide a concise overview of one area of this multidisciplinary subject, with an assessment of the status, a look at current and future challenges, and a brief summary. The ultimate goal of this initiative is to guide future mitigation strategies and design resilient components that can withstand the intense localised loads imposed by REs, thus ensuring the safe and sustainable operation of the next generation of fusion power plants.

Ratynskaia, Svetlana [KTH Royal Inst. of Technolog↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗

GridPIQ Reference Data

GridPIQ uses dozens of publicly available datasets to provide context for a user's grid project, as well as defaults for users to choose from. Users can choose to import their own data to better customize their analysis or use GridPIQ-supplied defaults. This allows users to get up and running with an analysis very quickly without having to spend significant time pulling together input data. To run an electric vehicle (EV) smart charging project, a user will need to provide or select from prepopulated values for the regional load profile shape and peak load, region of interest and closest weather station, EV charging profile, number of EVs to add for the analysis, maximum EV charging power, location of chargers relative to grid infrastructure, and allowable charging times (for coordinated charging mode). The outputs of the analysis are changes in air quality, EV energy consumption, EV peak demand, and EV hourly consumption profile—before and after project implementation." For a detailed description of the tool methodology, including all the publicly available datasets used by the tool, see the [GridPIQ documentation](https://gridpiq.pnnl.gov/v2-beta/doc/).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Central Asia Seismic Hazard Assessment (CASHA): A Probabilistic Seismic Hazard Assessment for Kazakhstan, Kyrgyzstan and Tajikistan

Probabilistic seismic hazard assessments (PSHA) underpin the calculation of earthquake loads in most building codes around the world. In Central Asia, the building codes are slowly being updated to incorporate some of the contemporary concepts of seismic hazard representation. There is also a regional desire to coordinate hazard assessments and building code modernization. However, some challenges remain. Expertise in the region related to seismic hazard assessments is still largely compartmentalised, requiring a significant amount of training and capacity building in seismic hazard assessment related topics. In addition, there are vast amounts of seismic data (bulletin and waveforms), both from analogue and digital eras, that the region’s countries stored but until recently did not use or share among themselves or with the broader seismological community around the world. Finally, after the collapse of the Soviet Union in the 1990s, many of the countries’ seismic networks suffered a major setback with the lack of attention and budget to update existing equipment and installation of new instruments. In order to address these issues, the United States Department of Energy through Lawrence Livermore National Laboratory (LLNL) initiated a project in 2016 to engage and train local scientists in Central Asia to install new equipment, to enhance the quality of seismic monitoring and reporting, to improve and harmonise the regional earthquake catalogue, and to conduct national probabilistic seismic hazard assessments using the new and improved datasets. To achieve the seismic hazard assessment related goals, a series of workshops were held in Almaty, Kazakhstan; Bishkek, Kyrgyzstan; and Dushanbe, Tajikistan from 2016 until 2020. During the time that the COVID-19 pandemic restricted travel, workshops continued online (22 online workshops were hosted in two years). Finally, in May 2022, an in-person workshop in Istanbul, Turkey brought together all project participants along with civil engineers engaged with building code activities in their respective countries, providing a platform to discuss the implementation of the hazard models into updates of building codes in each country, as well as to discuss model parameters, sensitivity analyses and model results in terms of hazard maps, uniform hazard spectra and hazard deaggregations. The workshops were a combination of lectures and hands-on exercises, and included international participation as well as local scientists and engineers. The workshops served several purposes, including training, coordination of data collection, interactions between local earth scientists and engineers, and brainstorming and knowledge exchange among local and international experts. This report outlines the new earthquake catalogue compilation effort and the PSHA project undertaken in Kyrgyzstan, Tajikistan, and Kazakhstan as part of this initiative. The southern part of this region is tectonically active with moderate to high levels of both shallow crustal seismic activity and occurrence of deeper earthquakes under the Hindu Kush and Pamir mountain ranges. Deeper earthquakes also occur near southwestern Kazakhstan, under the eastern Greater Caucasus and Caspian Sea. Large portions of central and northern Kazakhstan, on the other hand, are in stable continental regions with low levels of seismic activity. This study systematically compiles and improves all available data on local seismicity, active faults, and ground motion attenuation characteristics of the region; and builds a framework to enable a contemporary PSHA to be carried out with the engagement of local scientists. While the project was regional, the seismic hazard assessments are primarily driven by the countries’ own national preferences and understanding of data collection, interpretation, and validation of results.

58 GEOSCIENCES↗

Getting brighter: Impacts of improved day-ahead solar forecasts in high-solar, high-storage electricity systems

This paper analyzes the impacts of improved day-ahead solar forecasts on costs and dispatch in the solar-rich Southeast U.S. It uses an optimized high-solar, high-storage resource portfolio in which solar generation capacity accounts for 45 % of total installed capacity (34 %–36 % of generation) and energy storage capacity (43 GW) is equivalent to 33 % of peak demand. In a base scenario, improved day-ahead solar forecasts reduce production costs by $\$87$ million per year ($\$0.13$ per MWh load, $2023$$). This level of savings is within the range or lower than earlier studies of solar forecast improvements at lower levels of solar generation (<25 % of total generation). In this study, solar expansion was accompanied by two important sources of flexibility for managing solar forecast error: energy storage and day-ahead solar curtailment. Furthermore, the analysis finds that regional coordination complements day-ahead solar forecast improvements while natural gas commitment flexibility is a substitute for forecast improvements, as the improved solar forecast leads to sub-optimal commitment of thermal units. Day-ahead solar forecast improvements reduce reserves required to manage forecast error by 30 %. Fewer reserves to manage large, infrequent solar forecast errors could be an important benefit of improved solar forecasts.

14 SOLAR ENERGY↗

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Complete separation of benzene-cyclohexene-cyclohexane mixtures via temperature-dependent molecular sieving by a flexible chain-like coordination polymer

Abstract The separation and purification of C6 cyclic hydrocarbons (benzene, cyclohexene, cyclohexane) represent a critically important but energy intensive process. Developing adsorptive separation technique to replace thermally driven distillation processes holds great promise to significantly reduce energy consumption. Here we report a flexible one-dimensional coordination polymer as an efficient adsorbent to discriminate ternary C6 cyclic hydrocarbons via an ideal molecular sieving mechanism. The compound undergoes fully reversible structural transformation associated with removal/re-coordination of water molecules and between activated and hydrocarbon-loaded forms. It exhibits distinct temperature- and adsorbate-dependent adsorption behavior which facilitates the complete separation of benzene, cyclohexene and cyclohexane from their binary and ternary mixtures, with the record-high uptake ratios for C 6 H 6 /C 6 H 12 and C 6 H 10 /C 6 H 12 in vapor phase and highest binary and ternary selectivities in liquid phase. In situ infrared spectroscopic analysis and ab initio calculations provide insight into the host-guest interactions and their effect on the preferential adsorption and structural transformation.

36 MATERIALS SCIENCE↗