Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long Time Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

ExCALiBR: An Instrument for Uncovering the Origin of the Moon’s Organics.

Lipids are organic molecules of great astrobiological interest for future NASA missions to the Moon, Mars and Icy Worlds. Lipids are essential for life as we know it, and likely also required for putative extraterrestrial organisms. These robust organics can be synthesized abiotically and survive for long periods of geological time. Laboratory characterization techniques are well established but are laborious, operator dependent, and require large volumes of consumables, precluding in situ analysis. We are developing an autonomous, miniaturized fluidic system, integrating lab techniques for lipid analysis while minimizing rea-gent volumes and concentrating organics for analysis, thereby increasing signal-to-noise ratios by orders of magnitude. This system, the Extractor for Chemical Analysis of Lipid Biomarkers in Regolith (ExCALiBR), will enable future organic surveys by extracting and concentrating lipids from approximately 50 grams of regolith using a fluidic and microfluidic sample processor made of materials compatible with non-aqueous solvents required for extraction. ExCAL-iBR can be deployed on a lander or used on a crewed mission.

M B Wilhelm↗

Detectability Simulations of a Near-infrared Surface Biosignature on Proxima Centauri b with Future Space Observatories

Telescope missions are currently being designed that will make direct imaging of habitable exoplanets possible in the near future, and studies are needed to quantify the detectability of biosignature features in the planet's reflectance spectrum. We simulated the detectability of a near-infrared-absorbing surface biosignature feature with simulated observations of the nearby exoplanet Proxima Centauri b. We modeled a biosignature spectral feature with a reflectance spectrum based on an anoxygenic photosynthetic bacterial species that has strong absorption at 1 μm, which could make it well suited for life on an M-dwarf-hosted planet. We modeled the distribution of this organism across the planet's surface based on climate states from a 3D general circulation model (GCM) that were Archean- and Proterozoic-like exo-Earth analogs. We included the GCM states' prognostically simulated water clouds and added organic haze into the Archean-like atmospheres. We simulated observations of these Proxima Centauri b scenarios with the LUVOIR-A and B telescope concepts, with LUVOIR-B serving as a proxy to the planned Habitable Worlds Observatory. We calculated the integration times necessary to detect the biosignature and found that it would be detectable on Proxima Centauri b if the organism is moderately abundant (greater than a 1%–4% global surface area coverage), as long as the atmosphere is transmitting in the wavelength range under consideration. Small amounts of methane, clouds, and haze do not greatly impede detectability. We found preliminary evidence that such a biosignature would be detectable on exoplanets within 15 pc, but further investigations are needed to corroborate this.

Exoplanet astronomy↗

Reduced Organic Outgassing in the NASA Osiris-Rex and Hayabusa2 Curation Facility by Careful Selection and Implementation of Cleanroom Construction Materials

In October 2021, NASA Johnson Space Center (JSC) Astromaterials Acquisition and Cu-ration Office in JSC bldg. 31 completed construction and commissioning of the OSIRIS-REx and Hayabusa2cleanroom laboratory suites along with new precision cleaning and advanced curation laboratories: •OSIRIS-REx Curation Cleanroom: ISO Class 5•Hayabusa2 Curation Cleanroom: ISO Class 5•Final Precision Cleaning Cleanroom: ISO Class 5•Advanced Precision Cleaning Cleanroom: ISO Class 6•PreClean Precision Cleaning Cleanroom: ISO Class 6•Advanced Curation Cleanroom: ISO Class 7The new curation facilities are designed for initial receiving, basic characterization, curation processing, and preliminary examination of carbonaceous asteroidal material. The facilities are also designed to enable long-term pristine sample storage to preserve the scientific integrity of each sample to enable decades of future re-search by the international science community. The scientific study of organics in general is critical for both missions. The OSIRIS-REx mission executed a stringent contamination control plan [1] where all sample hardware at time of sample acquisition would be at Level 100 A/2 per IEST-STD-CC1246D (non-volatile residue (NVR) < 500 ng/cm2). In addition, the mission imposed a requirement of <180 ng/cm2 for amino acids (and hydrazine) [1]. Given these mission requirements, long-term storage preservation requirements, and information from the Organic Contamination Baseline Study at JSC [2], the JSC Curation team decided to carefully select cleanroom construction materials that would not hinder the scientific search for amino acids and the study of organics in the samples [3].

astromaterials curation↗

An Integrated Musculoskeletal Countermeasure Battery for Long-Duration Lunar Missions

During extended periods of skeletal unloading, losses in strength and density of the proximal femur will occur. In long-duration spaceflight, resistive exercise is used to replace the normal loads exerted on the spine and hip. At the present time, there is no conclusive evidence that hip bone loss has been prevented in this scenario. Our group has recently developed and clinically evaluated a multifunctional exercise system, the Combined Countermeasure Device (CCD). The CCD comprises a low-footprint Stuart Platform for lower-body resistance exercise and balance training, and a cardiovascular exercise bicycle. A consideration for resistance exercise was targeting of the hip abductor and adductor muscles, which attach directly at the hip and which should subject it to the largest loads. In our training study, we found that CCD exercise increased hip adductor and abductor strength, and modeling results suggest that this exercise exerts forces on the hip of approx. 4-6 body weights at 1g, compared to forces of approx.2.5 body weight y squatting exercise. In our current study, we hypothesize that abductor and adductor exercise will increase the density and strength of the proximal femur.

Lang, T. F.↗

A low-power battery ampere-hour meter

A digital device has been developed to meter the current drain of a battery in ampere hours. The device consists of a voltage controlled oscillator (VCO), a frequency divider, an accumulator, and a liquid crystal display. A voltage proportional to load current is converted into a clock signal whose pulse rate is scaled by the frequency divider to the desired engineering units. Final output pulses are counted and displayed. The use of MOSFET and CMOS integrated circuits allows continuous battery-powered operation over a 3-month time period to an accuracy of +/- 2 percent. The instrument will find application where accurate monitoring of battery charge/discharge status is required over long time intervals.

Tripp, John S.↗

Perspectives on African Ozone from Sondes, Dobson and Aircraft Measurements

We have been studying variability in ozone over Africa using data from ozonesondes (vertical profiles from surface to stratosphere), aircraft (the MOZAIC dataset with cruise altitude and landing/takeoff profiles) and the ground (Dobson spectrophotometer total ozone column measurement). The following may give context for ozone investigations during AMMA: 1. Total ozone measurements since 1989 show considerable variability in mean value among the African stations in Algeria, Kenya, Egypt, South Africa, as well as in seasonal cycles and year-to-year. Trends are not evident. 2. The impacts of convection, stratospheric injection, biomass burning and lightning appear in ozone sounding profile data. Time-series analysis and case studies point to periodic influences of long-range interactions with the Atlantic ("ozone paradox," wave-one") and Indian Oceans. 3. Tropospheric ozone variations, observed in tropospheric profiles and integrated column amount, follow general seasonal patterns but short- term variability is so strong that simple averages are inadequate for describing "climatology" and statistical classification approaches may be required.

Thompson, A. M.↗

Habituation and adaptation of the vestibuloocular reflex: a model of differential control by the vestibulocerebellum

We habituated the dominant time constant of the horizontal vestibuloocular reflex (VOR) of rhesus and cynomolgus monkeys by repeated testing with steps of velocity about a vertical axis and adapted the gain of the VOR by altering visual input with magnifying and reducing lenses. After baseline values were established, the nodulus and ventral uvula of the vestibulocerebellum were ablated in two monkeys, and the effects of nodulouvulectomy and flocculectomy on VOR gain adaptation and habituation were compared. The VOR time constant decreased with repeated testing, rapidly at first and more slowly thereafter. The gain of the VOR was unaffected. Massed trials were more effective than distributed trials in producing habituation. Regardless of the schedule of testing, the VOR time constant never fell below the time constant of the semicircular canals (approximately 5 s). This finding indicates that only the slow component of the vestibular response, the component produced by velocity storage, was habituated. In agreement with this, the time constant of optokinetic after-nystagmus (OKAN) was habituated concurrently with the VOR. Average values for VOR habituation were obtained on a per session basis for six animals. The VOR gain was adapted by natural head movements in partially habituated monkeys while they wore x 2.2 magnifying or x 0.5 reducing lenses. Adaptation occurred rapidly and reached about +/- 30%, similar to values obtained using forced rotation. VOR gain adaptation did not cause additional habituation of the time constant. When the VOR gain was reduced in animals with a long VOR time constant, there were overshoots in eye velocity that peaked at about 6-8 s after the onset or end of constant-velocity rotation. These overshoots occurred at times when the velocity storage integrator would have been maximally activated by semicircular canal input. Since the activity generated in the canals is not altered by visual adaptation, this finding indicates that the gain element that controls rapid changes in eye velocity in the VOR is separate from that which couples afferent input to velocity storage. Nodulouvulectomy caused a prompt and permanent loss of habituation, returning VOR time constants to initial values. VOR gain adaptation, which is lost after flocculectomy, was unaffected by nodulouvulectomy. Flocculectomy did not alter habituation of the VOR or of OKAN. Using a simplified model of the VOR, the decrease in the duration of vestibular nystagmus due to habituation was related to a decrement in the dominant time constant of the velocity storage integrator (1/h0).(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

A preliminary study of head-up display assessment techniques. 2: HUD symbology and panel information search time

Twelve commercial pilots were shown 50 high-fidelity slides of a standard aircraft instrument panel with the airspeed, altitude, ADI, VSI, and RMI needles in various realistic orientations. Fifty slides showing an integrated head-up display (HUD) symbology containing an equivalent number of flight parameters as above (with flight path replacing VSI) were also shown. Each subject was told what flight parameter to search for just before each slide was exposed and was given as long as needed (12 sec maximum) to respond by verbalizing the parameter's displayed value. The results for the 100-percent correct data indicated that: there was no significant difference in mean reaction time (averaged across all five flight parameters) between the instrument panel and HUD slides; and a statistically significant difference in mean reaction time was found in responding to different flight parameters.

Guercio, J. G.↗

Developing a Simulation-Based Training Program for Non-Traditional Caregivers

Simulation-based training enables learning in controlled environments which nevertheless mimic real-world scenarios. It has proven effective in the training of medical personnel and affords rapid assimilation and integration of necessary skills. Non-traditional caregivers often operate in austere environments, where resource and personnel limitations preclude more standard provision of care by highly trained and fully equipped health care teams. In these settings, training time for the caregivers may be limited, with long gaps between time of the training and use of the skills, a limited grasp of the underlying physiology, and unfamiliarity with "medical English" which can render it difficult to communicate concepts to more advanced practitioners when such interaction can take place, as for example, when telemedicine can be used to project medical skills further forward . Methods: Simulation-based training can assist in the familiarization of caregivers to the environment, ensure adequate execution of skills at the appropriate time(s), and allow practice of telemedicine communication patterns between the mentor and caregiver. Results: Scenario-based training can and has been used for initial and sustainment training modules, including self-taught modules for use in the field. Strict identification of the critical concepts is vital, as is development and practice of technically simple procedures wherever possible. Medical devices can off-load tasks from caregivers, as well as to minimize the necessary level of caregiver knowledge, while integrated simulations among all members of the mission team can improve communication and efficiency. Discuss ion: Nontraditional caregivers face unique challenges when learning to provide medical care. Scenario-based curricula allow lesson plans to be tailored to each group's individual needs, as well as being suited for the participation of numerous groups, including the caregiver, evacuation/transport staff, decision-makers, and hospital-based physician.

Bacal, Kira↗

Long-Term Electronic Timer

Timing circuit turns on power source on command, then turns it off again after preset interval. In comparison with prior devices, unit consumes little power and is smaller, lighter in weight, and less complicated. Timer includes oscillator and counter in integrated circuit. Timing interval equals oscillator period multiplied by number of cycles to be counted.

Temple, G.↗

Space transfer vehicle concepts and requirements study. Volume 2, book 4: Integrated advanced technology development

The Space Transfer Vehicle (STV) program provides both an opportunity and a requirement to increase our upper stage capabilities with the development and applications of new technologies. Issues such as man rating, space basing, reusability, and long lunar surface storage times drive the need for new technology developments and applications. In addition, satisfaction of mission requirements such as lunar cargo delivery capability and lunar landing either require new technology development or can be achieved in a more cost-effective manner with judicious applications of advanced technology. During the STV study, advanced technology development requirements and plans have been addressed by the Technology/Advanced Development Working Group composed of NASA and contractor representatives. This report discusses the results to date of this working group. The first section gives an overview of the technologies that have potential or required applications for the STV and identifies those technologies baselined for the STV. Figures are provided that list the technology categories and show the priority placed on those technology categories for either the space-based or ground-based options. The second section covers the plans and schedules for incorporating the technologies into the STV program.

Weber, Gary A.↗

CSM solutions of rotating blade dynamics using integrating matrices

The dynamic behavior of flexible rotating beams continues to receive considerable research attention as it constitutes a fundamental problem in applied mechanics. Further, beams comprise parts of many rotating structures of engineering significance. A topic of particular interest at the present time involves the development of techniques for obtaining the behavior in both space and time of a rotor acted upon by a simple airload loading. Most current work on problems of this type use solution techniques based on normal modes. It is certainly true that normal modes cannot be disregarded, as knowledge of natural blade frequencies is always important. However, the present work has considered a computational structural mechanics (CSM) approach to rotor blade dynamics problems in which the physical properties of the rotor blade provide input for a direct numerical solution of the relevant boundary-and-initial-value problem. Analysis of the dynamics of a given rotor system may require solution of the governing equations over a long time interval corresponding to many revolutions of the loaded flexible blade. For this reason, most of the common techniques in computational mechanics, which treat the space-time behavior concurrently, cannot be applied to the rotor dynamics problem without a large expenditure of computational resources. By contrast, the integrating matrix technique of computational mechanics has the ability to consistently incorporate boundary conditions and 'remove' dependence on a space variable. For problems involving both space and time, this feature of the integrating matrix approach thus can generate a 'splitting' which forms the basis of an efficient CSM method for numerical solution of rotor dynamics problems.

Lakin, William D.↗

On the buoyancy-driven motion of a drop towards a rigid surface or a deformable interface

The deformation of a viscous drop, driven by buoyancy toward a solid surface or a deformable interface, is analyzed in the asymptotic limit of small Bond number, for which the deformation becomes important only when the drop is close to the solid surface or interface. Lubrication theory is used to describe the flow in the thin gap between the drop and the solid surface or interface, and boundary-integral theory is used in the fluid phases on either side of the gap. The evolution of the drop shape is traced from a relatively undeformed state until a dimple is formed and a long-time quasi-steady-state pattern is established. A wide range of drop to suspending phase viscosity ratios is examined. It is shown that a dimple is always formed, independently of the viscosity ratio, and that the long-time thinning rates take simple forms as inverse fractional powers of time.

Yiantsios, Stergios G.↗

Comparative Analysis of Radiometer Systems Using Non-Stationary Processes

Radiometers require periodic calibration to correct for instabilities in the receiver response. Various calibration techniques exist that minimize the effect of instabilities in the receivers. The optimal technique depends upon many parameters. Some parameters are constrained by the particular application and others can be chosen in the system design. For example, the measurement uncertainty may be reduced to the limits of the resolution of the measurement (sensitivity) if periodic absolute calibration can be performed with sufficient frequency. However if the period between calibrations is long, a reference-differencing technique, i.e. Dicke-type design, can yield better performance. The measurement uncertainty not only depends upon the detection scheme but also on the number of pixels between calibrations, the integration time per pixel, integration time per calibration reference measurement, calibration reference temperature, and the brightness temperature of what is being measured. The best scheme for reducing the measurement uncertainty also depends, in large part, on the stability of the receiver electronics. In this presentation a framework for evaluating calibration schemes for a wide range of system architectures is presented. Two methods for treating receiver non-stationarity are compared with radiometer measurements.

Racette, Paul↗

Jovian Northern Ethane Aurora and the Solar Cycle

Thermal infrared auroral spectra from Jupiter's North polar region have been collected from 1979 to 1998 in a continuing study of long-term variability in the northern thermal IR aurora, using C2H6 emission lines near 12 microns as a probe. Data from Voyager I and 2 IRIS measurements and ground based spectral measurements were analyzed using the same model atmosphere to provide a consistent relative comparison. A retrieved equivalent mole fraction was used to compare the observed integrated emission. Short term (days), medium term (months) and long term (years) variability in the ethane emission was observed. The variability Of C2H6 emission intensities was compared to Jupiter's seasonal cycle and the solar activity cycle. A positive correlation appears to exist, with significantly greater emission and short term variability during solar maxima. Observations on 60 N latitude during increased solar activity in 1979, 1989, and most recently in 1998 show up to 5 times brighter integrated line emission of C2H6 near the north polar "hot spot" (150-210 latitude) than from the north quiescent region. Significantly lower enhancement was observed during periods of lower solar activity in 1982, 1983, 1993, and 1995. Possible sources and mechanisms for the enhancement and variability will be discussed.

Kostiuk,T.↗

Algorithm for rapid integration of turbulence model equations on parabolic regions

While developing a three-dimensional boundary layer program using a standard parabolic matching scheme, the author has found computing time with the Wilcox-Rubesin (1979) two-equation turbulence model to be very lengthy. The long computing time occurs because converged solutions are possible only when very small streamwise steps are taken. The proposed remedy reduces computing time by increasing the maximum permissible step size.

Wilcox, D. C.↗

Real-time simulation for Space Station

Development of a new Space Station simulation designed to provide long-term support to the Space Station Program is well under way. A description of the two Engineering Directorate simulation facilities, the Systems Engineering Simulator and the Shuttle Avionics Integration Laboratory, is presented. The function of each in support of the Space Shuttle Program is discussed, with emphasis on functions applicable to Space Station. The function of the Systems Engineering Simulator in Space Station development is described. Finally, a comprehensive and detailed description of the new Space Station simulation under development on the System Engineering Simulator is presented.

St. John, Robert H.↗

Individualized Behavioral Health Monitoring Tool

Behavioral health risks during long-duration space exploration missions are among the most difficult to predict, detect, and mitigate. Given the anticipated extended duration of future missions and their isolated, extreme, and confined environments, there is the possibility that behavior conditions and mental disorders will develop among astronaut crew. Pulsar Informatics, Inc., has developed a health monitoring tool that provides a means to detect and address behavioral disorders and mental conditions at an early stage. The tool integrates all available behavioral measures collected during a mission to identify possible health indicator warning signs within the context of quantitatively tracked mission stressors. It is unobtrusive and requires minimal crew time and effort to train and utilize. The monitoring tool can be deployed in space analog environments for validation testing and ultimate deployment in long-duration space exploration missions.

Mollicone, Daniel↗