Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A low energy electron magnetometer

The concept of a highly sensitive magnetometer based on the deflection of low energy electron beams in magnetic fields is analyzed. Because of its extremely low mass and consequently high e/m ratio, a low energy electron is easily deflected in a magnetic field, thus providing a basis for very low field measurement. Calculations for a specific instrument design indicate that a low energy electron magnetometer (LEEM) can measure magnetic fields as low as 1000 nT. The anticipated performance of LEEM is compared with that of the existing high resolution magnetometers in selected applications. The fast response time of LEEM makes it especially attractive as a potential instrument for magnetic signature analysis in large engineering systems.

Singh, J. J.↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

COMPARISON OF FORCE-FREE CORONAL MAGNETIC FIELD MODELING USING VECTOR FIELDS FROM HINODE AND SOLAR DYNAMICS OBSERVATORY

Photospheric magnetic vector maps from two different instruments are used to model the nonlinear force-free coronal magnetic field above an active region. We use vector maps inferred from polarization measurements of the Solar Dynamics Observatory/Helioseismic and Magnetic Imager (HMI) and the Solar Optical Telescope's Spectropolarimeter (SP) on board Hinode. Besides basing our model calculations on HMI data, we use both SP data of original resolution and scaled down to the resolution of HMI. This allows us to compare the model results based on data from different instruments and to investigate how a binning of high-resolution data affects the model outcome. The resulting three-dimensional magnetic fields are compared in terms of magnetic energy content and magnetic topology. We find stronger magnetic fields in the SP data, translating into a higher total magnetic energy of the SP models. The net Lorentz forces of the HMI and SP lower boundaries verify their force-free compatibility. We find substantial differences in the absolute estimates of the magnetic field energy but similar relative estimates, e.g., the fraction of excess energy and of the flux shared by distinct areas. The location and extension of neighboring connectivity domains differ and the SP model fields tend to be higher and more vertical. Hence, conclusions about the magnetic connectivity based on force-free field models are to be drawn with caution. We find that the deviations of the model solution when based on the lower-resolution SP data are small compared to the differences of the solutions based on data from different instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Readout Scheme for SQUID-Based Thermometry

An improved readout scheme has been proposed for high-resolution thermometers, (HRTs) based on the use of superconducting quantum interference devices (SQUIDs) to measure temperature- dependent magnetic susceptibilities. The proposed scheme would eliminate counting ambiguities that arise in the conventional scheme, while maintaining the superior magnetic-flux sensitivity of the conventional scheme. The proposed scheme is expected to be especially beneficial for HRT-based temperature control of multiplexed SQUIDbased bolometer sensor arrays. SQUID-based HRTs have become standard for measuring and controlling temperatures in the sub-nano-Kelvin temperature range in a broad range of low-temperature scientific and engineering applications. A typical SQUIDbased HRT that utilizes the conventional scheme includes a coil wound on a core made of a material that has temperature- dependent magnetic susceptibility in the temperature range of interest. The core and the coil are placed in a DC magnetic field provided either by a permanent magnet or as magnetic flux inside a superconducting outer wall. The aforementioned coil is connected to an input coil of a SQUID. Changes in temperature lead to changes in the susceptibility of the core and to changes in the magnetic flux detected by the SQUID. The SQUID readout instrumentation is capable of measuring magnetic-flux changes that correspond to temperature changes down to a noise limit .0.1 nK/Hz1/2. When the flux exceeds a few fundamental flux units, which typically corresponds to a temperature of .100 nK, the SQUID is reset. The temperature range can be greatly expanded if the reset events are carefully tracked and counted, either by a computer running appropriate software or by a dedicated piece of hardware.

Penanen, Konstantin↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

Momentum Flux Measuring Instrument for Neutral and Charged Particle Flows

An instrument to measure the momentum flux (total pressure) of plasma and neutral particle jets onto a surface has been developed. While this instrument was developed for magnetized plasmas, the concept works for non-magnetized plasmas as well. We have measured forces as small as 10(exp -4) Newtons on a surface immersed in the plasma where small forces are due to ionic and neutral particles with kinetic energies on the order of a few eV impacting the surface. This instrument, a force sensor, uses a target plate (surface) that is immersed in the plasma and connected to one end of an alumina rod while the opposite end of the alumina rod is mechanically connected to a titanium beam on which four strain gauges are mounted. The force on the target generates torque causing strain in the beam. The resulting strain measurements can be correlated to a force on the target plate. The alumina rod electrically and thermally isolates the target plate from the strain gauge beam and allows the strain gauges to be located out of the plasma flow while also serving as a moment arm of several inches to increase the strain in the beam at the strain gauge location. These force measurements correspond directly to momentum flux and may be used with known plasma conditions to place boundaries on the kinetic energies of the plasma and neutral particles. The force measurements may also be used to infer thrust produced by a plasma propulsive device. Stainless steel, titanium, molybdenum, and aluminum flat target plates have been used. Momentum flux measurements of H2, D2, He, and Ar plasmas produced in a magnetized plasma device have been performed.

Chavers, Greg↗

Axial Halbach Magnetic Bearings

Axial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control.

Eichenberg, Dennis J.↗

Radial Halbach Magnetic Bearings

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Radial Halbach magnetic bearings are based on the same principle as that of axial Halbach magnetic bearings, differing in geometry as the names of these two types of bearings suggest. Both radial and axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control. Axial Halbach magnetic bearings were described in Axial Halbach Magnetic Bearings (LEW-18066-1), NASA Tech Briefs, Vol. 32, No. 7 (July 2008), page 85. In the remainder of this article, the description of the principle of operation from the cited prior article is recapitulated and updated to incorporate the present radial geometry. In simplest terms, the basic principle of levitation in an axial or radial Halbach magnetic bearing is that of the repulsive electromagnetic force between (1) a moving permanent magnet and (2) an electric current induced in a stationary electrical conductor by the motion of the magnetic field. An axial or radial Halbach bearing includes multiple permanent magnets arranged in a Halbach array ("Halbach array" is defined below) in a rotor and multiple conductors in the form of wire coils in a stator, all arranged so the rotary motion produces an axial or radial repulsion that is sufficient to levitate the rotor. A basic Halbach array (see Figure 1) consists of a row of permanent magnets, each oriented so that its magnetic field is at a right angle to that of the adjacent magnet, and the right-angle turns are sequenced so as to maximize the magnitude of the magnetic flux density on one side of the row while minimizing it on the opposite side. The advantage of this configuration is that it makes it possible to approach the theoretical maximum force per unit area that could be exerted by a given amount of permanent-magnet material. The configuration is named after physicist Klaus Halbach, who conceived it for use in particle accelerators. Halbach arrays have also been studied for use in magnetic-levitation ("maglev") railroad trains. In a radial Halbach magnetic bearing, the basic Halbach arrangement is modified into a symmetrical arrangement of sector-shaped permanent magnets mounted on the outer cylindrical surface of a drum rotor (see Figure 2). The magnets are oriented to concentrate the magnetic field on their radially outermost surface. The stator coils are mounted in a stator shell surrounding the rotor.

Eichenberg, Dennis J.↗

Response induction coil magnetometers to perturbations in orientation

© 1996-2018 Society of Exploration Geophysicists. All rights reserved. We explore the data collected by a 3-component induction coil magnetometer system with respect to motion of the instruments in earths static magnetic field. The sensitivtiy of the inductiuon coil magnetometer leads to unprecediented accuracy on tilt measurements. We model the signals observed during seismic events as being perturbations in coil orientation. In theory, these perturbations can include ground roll, ocean motion, nearby cultural seismicity, or any other field with a tilting effect. Using data from a magnetic observatory near Parkfield CA we invert several time series of coil data during different levels of seismic activity in an attempt to determine the magnitudes of rotation at which our model accurately describes the coil data. Finally, we explore the transfer function between the coils and nearby seismic instruments (accelerometers, tiltmeters, and velocity seismometers).

Kappler, K↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Emissions Tests Of Two Dc-To-Dc Converters

Report describes tests to characterize unwanted electric and magnetic fields, at frequencies up to few megahertz, radiated by two dc-to-dc converters, one 20-kHz square-wave converter; the other, a 33-kHz sine-wave converter. Part of effort to develop "quiet" power converter for use aboard spacecraft. Converter required to interfere minimally with delicate instruments measuring electric and magnetic fields.

Mclyman, W. T.↗

The ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron beam energy region. Experimental results

New experimental results on ratio R{sub dp} of the quasielastic charge-exchange yield at the outgoing proton angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield, are presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. The intense neutron beam with small momentum spread was produced by breakup of deuterons which were accelerated and extracted to the experimental hall. In both reactions mentioned above the outgoing protons with the momenta p{sub p} approximately equal to the neutron-beam momentum p{sub n,beam} were detected in the directions close to the direction of incident neutrons, i.e., in the vicinity of the scattering angle {theta}{sub p,lab} = 0 deg. Measured in the same data-taking runs, the angular distributions of the charge-exchange-reaction products were corrected for the well-known instrumental effects and averaged in the vicinity of the incident-neutron-beam direction. These corrected angular distributions for every of nd {yields} p(nn) and np {yields} pn charge-exchange processes were proportional to the differential cross sections of the corresponding reactions. The data were accumulated by Delta-Sigma setup magnetic spectrometer with two sets of multiwire proportional chambers located upstream and downstream of the momentum analyzing magnet. Inelastic processes were considerably reduced by the additional detectors surrounding the hydrogen and deuterium targets. The time-of-flight system was applied to identify the detected particles. The accumulated data treatment and analysis, as well as possible sources of the systematic errors are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Construction of an alternating gradient magnetometer

A magnetometer is described which was constructed to facilitate the study and characterization of the magnetic properties of high transition temperature superconductors. This instrument was used to measure the dc magnetic susceptibility of several superconducting compounds as a function of temperature. The construction of the magnetometer and the operating parameters are discussed in detail.

Garland, Michael M.↗

DSIF FR-900 video recorders

Deep Space Instrumentation Facility FR-900 ROTARY head magnetic tape recorders for acquiring video data from lunar orbiter

MAGNETIC TAPE RECORDER↗

Global Geospace Science (GGS) Program and the Polar Satellite

The Global Geospace Science (GGS) program's Polar satellite is reported on. The satellite aims to measure: the plasma flux in the polar magnetosphere and the geomagnetic tail; the plasma flux to and from the ionosphere, and the deposition of particle energy in the upper atmosphere. To accomplish these objectives, the satellite was placed on a 86 deg inclination, elliptical orbit whose apogee is located over the northern polar region. The spacecraft carries instruments for observing and measuring the magnetic field and charged particles as well as the imaging instruments.

Hoffman, R. A.↗

Magnetic back-to-back locator

A back-to-back locator instrument includes a first portion with an array of two or more magnetic sensors, and an indicator arrangement. A second portion of the instrument includes an array of correspondingly located magnets. Each of the first and second portions includes a marking arrangement, which either allows marking of the underlying surface, or viewing of a mark on the surface for properly locating the instrument portion thereon. When the two portions are congruent or registered, the indicator arrangement gives a maximum indication of corresponding locations. In a particular use, corresponding locations on the inside and outside of a tank are identified. The indicator arrangement may include a separate indicator for each magnetic sensor. A flux concentrator may be associated with each magnetic sensor.

Phillips, Scott G.↗