Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC MEMORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Tunable spin wave spectra in two-dimensional Ni{sub 80}Fe{sub 20} antidot lattices with varying lattice symmetry

Ferromagnetic antidot lattices are important systems for magnetic data storage and magnonic devices, and understanding their magnetization dynamics by varying their structural parameters is an important problems in magnetism. Here, we investigate the variation in spin wave spectrum in two-dimensional nanoscale Ni{sub 80}Fe{sub 20} antidot lattices with lattice symmetry. By varying the bias magnetic field values in a broadband ferromagnetic resonance spectrometer, we observed a stark variation in the spin wave spectrum with the variation of lattice symmetry. The simulated mode profiles showed further difference in the spatial nature of the modes between different lattices. While for square and rectangular lattices extended modes are observed in addition to standing spin wave modes, all modes in the hexagonal, honeycomb, and octagonal lattices are either localized or standing waves. In addition, the honeycomb and octagonal lattices showed two different types of modes confined within the honeycomb (octagonal) units and between two such consecutive units. Simulated internal magnetic fields confirm the origin of such a wide variation in the frequency and spatial nature of the spin wave modes. The tunability of spin waves with the variation of lattice symmetry is important for the design of future magnetic data storage and magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Microstructure and twinning in epitaxial NiMnGa films

Although magnetic shape memory alloys have attracted large scientific interest, miniaturization as single-crystalline thin films is still a greatly unresolved issue. In the present work we investigate the microstructure of epitaxial NiMnGa thin films which are fabricated by sputter deposition on magnesium oxide substrates at elevated temperatures. Transmission and scanning electron microscopy as well as atomic force microscopy studies are employed to relate surface topography to twin formation in 7 M martensitic NiMnGa films. Additional findings include pore formation in substrate proximity as well as minor precipitation with reduced nickel and gallium contents.

36 MATERIALS SCIENCE↗

Emergent Quantum Magnetism and Cryogenic Spin-Memory in Twisted Bilayer Graphene

Recently developed techniques for assembling moiré heterostructures have enabled unprecedented control of the interlayer interactions within the heterostructure, allowing for the realization of strongly correlated electronic states. The experimentally realized states, to date, include a variety of topological states, superconductivity, and strange metal behavior. However, the phenomenology varies significantly from sample to sample. Here we will present microscopy techniques for further characterization of both the progenitor exfoliated materials and the composite moiré heterostructure. The application of these techniques has allowed for an unprecidented degree of characterization in ambient conditions. Additionally we will explore the use of resistively detected electron spin resonance (ESR) as a novel probe for spin order in moirés. While our results do not show clearly dispersive features that would unambiguously evince spin excitations within the sample, the technique is still promising.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computerized spectrum analysis

Automatic spectral data reduction and analysis system consisting of densitometer, analog-digital converter and IBM 1800 process computer with magnetic disk memory

Kylstra, C. D.↗

Titan probe technology assessment and technology development plan study

The need for technology advances to accomplish the Titan probe mission was determined by defining mission conditions and requirements and evaluating the technology impact on the baseline probe configuration. Mission characteristics found to be technology drivers include (1) ten years dormant life in space vacuum; (2) unknown surface conditions, various sample materials, and a surface temperature; and (3) mission constraints of the Saturn Orbiter Dual Probe mission regarding weight allocation. The following areas were identified for further development: surface sample acquisition system; battery powered system; nonmetallic materials; magnetic bubble memory devices, and the landing system. Preentry science, reliability, and weight reduction and redundancy must also be considered.

Castro, A. J.↗

Design, development, and field demonstration of a remotely deployable water quality monitoring system

A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

Wallace, J. W.↗

Feasibility of self-structured current accessed bubble devices in spacecraft recording systems

The self-structured, current aperture approach to magnetic bubble memory is described. Key results include: (1) demonstration that self-structured bubbles (a lattice of strongly interacting bubbles) will slip by one another in a storage loop at spacings of 2.5 bubble diameters, (2) the ability of self-structured bubbles to move past international fabrication defects (missing apertures) in the propagation conductors (defeat tolerance), and (3) moving bubbles at mobility limited speeds. Milled barriers in the epitaxial garnet are discussed for containment of the bubble lattice. Experimental work on input/output tracks, storage loops, gates, generators, and magneto-resistive detectors for a prototype device are discussed. Potential final device architectures are described with modeling of power consumption, data rates, and access times. Appendices compare the self-structured bubble memory from the device and system perspectives with other non-volatile memory technologies.

Nelson, G. L.↗

Concept of a programmable maintenance processor applicable to multiprocessing systems

A programmable maintenance processor concept applicable to multiprocessing systems has been developed at the NASA Ames Research Center's Dryden Flight Research Facility. This stand-alone-processor is intended to provide support for system and application software testing as well as hardware diagnostics. An initial machanization has been incorporated into the extended aircraft interrogation and display system (XAIDS) which is multiprocessing general-purpose ground support equipment. The XAIDS maintenance processor has independent terminal and printer interfaces and a dedicated magnetic bubble memory that stores system test sequences entered from the terminal. This report describes the hardware and software embodied in this processor and shows a typical application in the check-out of a new XAIDS.

Glover, Richard D.↗

Spectral transmissometer and radiometer - Design and initial results

A new solid-state spectral transmissometer and radiometer is described. The radiometer measures upwelling radiance, downwelling irradiance, and beam transmittance from 390 to 750 nm with channel widths of 2.35 nm. The spectrometer consists of a 256 element CCD linear array collecting light dispersed by a reflection grating in a modified Littrow configuration. The spectrometer is time and space-shared among the three signal types. The instrument has been deployed as a free-drifting buoy and in the profiling mode, with data stored internally on a magnetic bubble memory or sent up a conducting cable as desired. Power can be supplied either by a detachable external battery pack or through conducting cable. The instrument has been deployed in the oligotrophic North Pacific Central Gyre and in the eutrophic Straits of Juan de Fuca, and preliminary results for each region are discussed.

Carder, Kendall L.↗

Programmable Maintenance Processor For XAIDS

Programmable maintenance processor (MAINT) made of commercially available integrated circuits. Autonomous one of four digital electronic processors in extended aircraft interrogation and display system (XAIDS). Developed for testing of system and application computer programs as well as for testing equipment. MAINT has independent terminal and printer interfaces and dedicated magnetic bubble memory storing system-testing sequences entered from terminal. Software for MAINT written in PLM86 programming language and broken into four separate modules.

Glover, Richard↗

Domain-wall oscillations studies by time-resolved soft x-ray mircorscopy

Fast magnetization dynamics in the micro- and nanometer regime are an interesting field of research. On these length scales magnetic structures can be designed to contain a single vortex or a single domain wall. Both size and speed of these patterns are of great interest in todays research for prospective non-volatile data storage devices. Especially the possibility to move domain-walls by spin-polarized current gained a lot of interest. Magnetic configurations can be imaged by soft X-ray magnetic microscopy with a spatial resolution down to 15 nm. By a stroboscopic pump and probe measurement scheme a temporal resolution below 100 ps is achieved. This provides the opportunity to directly image changes in magnetic domains and domain-wall motion. We image oscillations of a single domain wall in a confining potential in time steps of 200 ps by time resolved X-ray microscopy at the full-field soft X-ray transmission microscope at the Advanced Light Source in Berkeley (beamline 6.1.2). Domain walls are prepared in permalloy nanostructures with a restoring potential. The oscillation of a 180{sup o} domain wall is triggered by nanosecond current pulses. The spin-polarized current and the accompanying Oersted field can contribute to the motion of the wall. By analysis of the distinct domain-wall dynamics the dominant contribution is determined. In our geometry the motion of the wall is determined by the Oersted field although the spin-polarized current directly flows through the ferromagnetic structure. An analytical model of a rigid particle precisely describes the domain-wall motion. Oscillations are studied for different pulse length and amplitudes. From the observed oscillations we extract the driving force, the confining potential, and the domain-wall mass. Nonharmonic terms determine the motion of the wall. The influence of the nonharmonic potential is studied by looking at various phase spaces of the domain-wall motion.

36 MATERIALS SCIENCE↗

Macrospin modeling of sub-ns pulse switching of perpendicularly magnetized free layer via spin-orbit torques for cryogenic memory applications

We model, using the macrospin approximation, the magnetic reversal of a perpendicularly magnetized nanostructured free layer formed on a normal, heavy-metal nanostrip, subjected to spin-orbit torques (SOTs) generated by short (≤0.5 ns) current pulses applied to the nanostrip, to examine the potential for SOT-based fast, efficient cryogenic memory. Due to thermal fluctuations, if solely an anti-damping torque is applied, then, for a device with sufficiently low anisotropy (H{sub anis}{sup 0} ∼ 1 kOe) suitable for application in cryogenic memory, a high magnetic damping parameter (α∼0.1−0.2) is required for reliable switching over a significant variation of pulse current. The additional presence of a substantial field-like torque improves switching reliability even for low damping (α≤0.03).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗