Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RELAXATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

259 records · Page 15

Non-Thermal Hard X-Ray Emission in Galaxy Clusters Observed with the BeppoSAX PDS

We study the X-ray emission in a sample of galaxy clusters using the BeppoSAX PDS instrument in the 20-80 keV energy band. We estimate the nonthermal hard X-ray (HXR) cluster emission by modeling the thermal contribution from the cluster gas and the nonthermal contamination from the unobscured active galactic nuclei (AGNs) in the clusters. We also evaluate the systematic uncertainties due to the background fluctuations. Assuming negligible contamination from the obscured AGNs, the resulting nonthermal component is detected at a 2 sigma level in approx. 50% of the nonsignificantly AGN-contaminated clusters: A2142, A2199, A2256, A3376, Coma, Ophiuchus, and Virgo. The data are consistent with a scenario whereby relaxed clusters have no hard X-ray component of nonthermal origin, whereas merger clusters do, with a 20-80 keV luminosity of approx. 10(exp 43)-10(exp 44) h(sup -2 sub 50) ergs/s. The co-added spectrum of the above clusters indicates a power-law spectrum for the HXR emission with a photon index of 2.8(sup +0.3 sub -0.4) in the 12-115 keV band, and we find indication that it has extended distribution. These indications argue against significant contamination from obscured AGNs, which have harder spectra and a centrally concentrated distribution. These results are supportive of the assumption of the merger shock acceleration of electrons in clusters, which has been proposed as a possible origin of the nonthermal hard X-ray emission models. Assuming that the cosmic microwave background photons experience inverse Compton scattering from the merger-accelerated relativistic electrons and thus produce the observed HXR, the measured hard X-ray slope corresponds to a differential momentum spectra of the relativistic electrons with a slope of mu = 3.8-5.0. In presence of cluster magnetic fields this relativistic electron population produces synchrotron emission with a spectral index of 1.4-2.1, consistent with radio halo observations of merger clusters. Thus both hard X-ray and radio observations of merger clusters are consistent with the inverse Compton model.

Nevalainen, J.↗

The MR appearance of volume overload in the lower extremities

PURPOSE: Our goal was to describe the MR findings of volume overload (VO) in the lower extremities. METHOD: Fifteen individuals were studied, including eight healthy controls and seven patients with VO (four cardiac, three renal). MR evaluation included various SE techniques. Edema detection, localization, and symmetry were assessed subjectively. Relaxation time estimates were also made of the subcutaneous tissue, marrow, and three muscles. RESULTS: Subcutaneous tissue was markedly edematous in seven of seven patients and asymmetric in four of seven, whereas marrow was normal in all patients. Muscle edema was mild and asymmetric in six and two of seven patients, respectively. Perifascial fluid collections were identified in six of seven patients. CONCLUSION: Subcutaneous tissue edema is the dominant feature of VO in the lower extremities. Perifascial fluid is common but does not necessarily distribute symmetrically. Muscle edema is relatively mild. These findings should aid in identifying VO as the potential cause of swelling in patients with swollen legs.

Non-NASA Center↗

The Atmosphere-Space Transition Region Explorer (ASTRE) – A Low Perigee Satellite to Investigate the Coupling of the Earth’s Upper Atmosphere and Magnetosphere

The Atmosphere-Space Transition Region Explorer (ASTRE) is a mission concept designed to carry out an unprecedented study of the interaction between the Earth’s atmosphere and the ionized gases of space within the atmosphere-space transition region. By gathering direct measurements of the coupling of ion and neutral gases in this region, ASTRE provides the critical missing link in our knowledge of the transfer, dissipation, and regulation of energy and momentum between the sun and the upper atmosphere. ASTRE provides the first detailed, systematic investigation of this important unexplored region, vastly improves and constrains models of the upper atmosphere, and fills a critical gap in our understanding of how the coupled lower ionosphere/upper atmosphere “works” as a system. To achieve its science objectives, ASTRE gathers accurate measurements of plasma and neutral gases, electric and magnetic fields, and energetic particles using well-proven, in situ instruments with excellent flight heritage. Furthermore, as described herein, all the instruments have been designed to perform well in the low perigee environment, including altitudes of 150 km and lower. ASTRE utilizes a three-axis stabilized satellite that uses on-board propulsion to carry out systematic, low perigee measurements at high latitudes. The satellite design incorporates a “form follows function” approach with a cylindrical shape and conductive body-mounted solar arrays to minimize drag and perturbations to the space environment. Atomic-oxygen resistant materials are utilized and a passive thermal design with heat pipes and radiator panels minimizes the impact of aero-heating. ASTRE launches into a 250 km × 1500 km elliptical insertion orbit with an inclination of 83°. Perigee precesses from its highest northern latitude to its highest southern latitude every ~60 days. Hydrazine propulsion provides over 2000 orbits with perigee below 200 km, with a significant fraction as low as 150 km, during high latitude, two-week campaigns when perigee precesses to either the northern or southern high latitude region. At mid and low latitudes, the perigee is near 225 km. Because very conservative assumptions were made with respect to the orbital analysis and drag, including continuous 3-sigma “worst-case” solar flux and atmospheric density, when additional propellant is included (accommodated in the current design) and some of the stringent assumptions are relaxed, the ASTRE mission described herein may be expected to include repeated excursions to altitudes of ~130 km or even lower. This paper presents an overview of the ASTRE mission, its science motivation, and objectives. It includes a discussion of the science-driven requirements and traceability, followed by a “proof-of concept” implementation that includes notional instruments and a straightforward spacecraft design. Three key points are demonstrated: 1) There is a critical knowledge gap in the high latitude, atmosphere-space transition region below 250 km; 2) The instrument and measurement techniques needed to obtain the ASTRE measurements are well-proven and function well in the low-altitude environment; and 3) A mature spacecraft design, flight dynamics analysis, and concept of operations have been developed that demonstrate that the ASTRE mission can be achieved in a straightforward manner using current technologies.

Ionosphere↗

Reduced xenon diffusion for quantitative lung study--the role of SF(6)

The large diffusion coefficients of gases result in significant spin motion during the application of gradient pulses that typically last a few milliseconds in most NMR experiments. In restricted environments, such as the lung, this rapid gas diffusion can lead to violations of the narrow pulse approximation, a basic assumption of the standard Stejskal-Tanner NMR method of diffusion measurement. We therefore investigated the effect of a common, biologically inert buffer gas, sulfur hexafluoride (SF(6)), on (129)Xe NMR and diffusion. We found that the contribution of SF(6) to (129)Xe T(1) relaxation in a 1:1 xenon/oxygen mixture is negligible up to 2 bar of SF(6) at standard temperature. We also measured the contribution of SF(6) gas to (129)Xe T(2) relaxation, and found it to scale inversely with pressure, with this contribution approximately equal to 1 s for 1 bar SF(6) pressure and standard temperature. Finally, we found the coefficient of (129)Xe diffusion through SF(6) to be approximately 4.6 x 10(-6) m(2)s(-1) for 1 bar pressure of SF(6) and standard temperature, which is only 1.2 times smaller than the (129)Xe self diffusion coefficient for 1 bar (129)Xe pressure and standard temperature. From these measurements we conclude that SF(6) will not sufficiently reduce (129)Xe diffusion to allow accurate surface-area/volume ratio measurements in human alveoli using time-dependent gas diffusion NMR.

Non-NASA Center↗

Is Doppler tissue velocity during early left ventricular filling preload independent?

BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.

Non-NASA Center↗

Hyperpolarized (129)Xe T (1) in oxygenated and deoxygenated blood

The viability of the new technique of hyperpolarized (129)Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin-lattice relaxation time, T(1), of (129)Xe is sufficiently long in the blood. In previous experiments by the authors, the T(1) was found to be strongly dependent upon the oxygenation of the blood, with T(1) increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79-86) reported extremely long T(1) values deduced from an indirect experiment in which hyperpolarized (129)Xe was used to create a 'blood-foam'. They found that oxygenation decreased T(1). Pivotal to their experiment is the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T(1) of (129)Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized (129)Xe has been bubbled through the sample. This study confirms that oxygenation increases the T(1) of (129)Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO(2) oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.

NASA Discipline Life Support Systems↗

MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times

The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.

NASA Discipline Musculoskeletal↗