Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

FECM/NETL Hydrogen Pipeline Cost Model (2024): Description and User’s Manual

The FECM/NETL Hydrogen Pipeline Cost Model (H2_P_COM) estimates costs for transporting gaseous hydrogen in a pipeline from a source, such as a hydrogen production facility, to a final destination which may be a user of the hydrogen or a distribution center where hydrogen in the pipeline is diverted to multiple end users. This document provides two main functions. First, the document describes the equations and algorithms that are used by the model to calculate technical quantities (such as the minimum inner pipe diameter needed to transport a user-specified H 2 mass flow rate a specified distance) and engineering-economic quantities (such as capital costs, operating costs, and cash flows). Second, the document is a user’s manual for the model that describes the procedures the user must follow to run the model. The model can be accessed at this URL: https://www.netl.doe.gov/energy-analysis/details?id=db897190-8e26-40b1-9535-ee78ac934193

08 HYDROGEN↗

C Modules Enrichment

Module C1 discusses the step in the nuclear fuel cycle where the UF6 solid in cylinders from the conversion plant is processed to enrich the percentage of U-235 from 0.711% to the 3–5% typical of the enrichment used for light-water reactor nuclear fuel fabrication. It involves receipt of UF6 feed stock in 12.5 ton cylinders, enrichment operations, formation of enriched UF6 solid, and shipment of 2.3 ton cylinders to fuel fabricators. In this module, “SWU” is taken as shorthand for kg-SWU, the formal units for enrichment work, assuming that heavy metal mass flows will be gauged in kg.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Autonomous Infrared and Small (Wide) Angle X-Ray Scattering (IR-S(W)AXS) Capability

Thin water films are 2-D, nanoconfined layers that form on solid surfaces exposed to humid atmospheres—environments ubiquitous across catalysis, corrosion science, soil science, and subsurface geochemistry. At relative humidity (RH) values below saturation, these films are Å–nm thick and exhibit properties that differ sharply from bulk water, including disrupted H-bonding and impeded mass transport. Owing to their high surface-to-volume ratio, dissolution of the solid can rapidly drive strong supersaturation with respect to secondary phases. Reactivity in thin water films is highly sensitive to film thickness, and critically, thickness evolves during reaction because the hygroscopicity of the interfacial system changes as ions accumulate or diminish in the film and as reaction products transform. To accurately probe and control these dynamics, a capability is needed that can measure and automatically maintain a constant water-film thickness while simultaneously monitoring solid dissolution, nucleation, and growth. This project developed an autonomous Infrared/Small Angle X-ray Scattering-Wide Angle X-ray Scattering (IR/(W)SAXS) for investigating reactivity in thin water films on solid surfaces exposed to humidified gases. The capability consists of an IR spectrometer, a (W)SAXS instrument, and a mass flow controller system for generating variably humidified gas flows to a custom reaction cell. Progress on each of the major components of the capability are detailed below.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

Effects of Inlet Area Ratio on Operability of an Axial Air Inlet Rotating Detonation Combustor

This research presents the first results from a new Rotating Detonation Combustor (RDC) design with an axial air inlet and rear-facing angled fuel injection. This design features a variable air inlet that allows for the study of the effect of inlet area ratio on operation and to directly study the coupling between the air plenum and channel of the RDC while minimizing inlet pressure losses. This device maintains the same downstream channel configuration as those previously tested in our laboratory, which includes a 154 mm outer channel diameter and a constant area channel with a width of 7.6 mm. All tests were completed with a downstream hydrogen-air afterburner capable of flashing back in the channel to initiate detonation operation. Initial tests demonstrated successful operation at air mass flow rates from 160 to 770 g/s and equivalence ratios from 0.53 to 1.05 at multiple air inlet to channel area ratios, indicated that sensors installed within the air feed plenum are able to characterize the dynamic characteristics of waves within the detonation channel, and verified that the design goals for this configuration were achieved.

Shepard, Joshua↗

Markov Chain Monte Carlo Parameter Estimation of Deflagration Losses in a Rotating Detonation Engine

One of the practical challenges of the studies of rotating detonation engines (RDEs) is the direct estimation of losses from experimental measurements. This study attempts at resolving this limitation by combining a reduced order model (ROM) of the detonation wave characteristics with a Markov chain Monte Carlo parameter estimation framework. The model considers simple deflagration losses and the overall impact of deflagration on RDE performance. To evaluate this model, a Markov Chain Monte Carlo (MCMC) sampling technique was applied to estimate the loss parameters within the model for a set of conditions operated in hydrogen-air over a range of mass flow rates and equivalence ratios. The MCMC parameter estimation framework allowed for the determination of a posterior distribution of the loss parameters for each test condition, an examination of the correlation between the loss parameters and measured performance metrics of the RDE, and an uncertainty propagation of these parameters. The predicted model loss parameters were then compared to indirect experimental measurements of the deflagration combustion fractions to evaluating the validity of the approach, and shed light on the benefits and drawbacks of the model, measurement techniques, and the estimation framework.

33 ADVANCED PROPULSION SYSTEMS↗

Beneath the Bark: Assessing Woody Stem Water and Carbon Fluxes and Its Prevalence Across Climates and the Woody Plant Phylogeny

While woody stems are known to influence carbon and water dynamics, direct exchange with the atmosphere is seldom quantified, limiting our understanding of how these processes influence the exchange of mass and energy. The presence of woody stem chlorophyll in a diversity of climates and across a range of species suggests an evolutionary advantage to sustaining carbon assimilation and water relations through permeable stem tissue. However, no formal evaluation of this hypothesis has been performed. In this mini-review, we explore the interactions between woody stems and the atmosphere by examining woody stem photosynthesis and bark-atmosphere water exchange. Specifically, we address the following questions: (1) How do water and carbon move between the atmosphere and woody stems? (2) In what climate space is woody stem photosynthesis and bark water uptake advantageous? (3) How ubiquitous across plant families is woody stem photosynthesis and bark-atmosphere water exchange? In the literature, only seven species have been identified as exhibiting bark water uptake while over 300 species are thought to conduct woody stem photosynthesis. The carbon dioxide and water gained from these processes can offset respiration costs and improve plant water balance. These species span diverse biomes suggesting a broad prevalence of bark-atmosphere permeability. Finally, our results demonstrate that there may be an evolutionary component as demonstrated by a high Pagel’s lambda for the presence of stem photosynthesis. We end with recommendations for future research that explores how bark water and carbon interactions may impact plant function and mass flow in a changing climate.

54 ENVIRONMENTAL SCIENCES↗

Engineering-Scale Integrated Energy System Data Projection Demonstration via the Dynamic Energy Transport and Integration Laboratory

The objective of this study is to demonstrate and validate the Dynamic Energy Transport and Integration Laboratory (DETAIL) preliminary scaling analysis using Modelica language system-code Dymola. The DETAIL preliminary scaling analysis includes a multisystem integral scaling package between thermal-storage and hydrogen-electrolysis systems. To construct the system of scaled equations, dynamical system scaling (DSS) was applied to all governing laws and closure relations associated with the selected integral system. The existing Dymola thermal-energy distribution system (TEDS) facility and high-temperature steam electrolysis (HTSE) facility models in the Idaho National Laboratory HYBRID repository were used to simulate a test case and a corresponding scaled case for integrated system HYBRID demonstration and validation. The DSS projected data based on the test-case simulations and determined scaling ratios were generated and compared with scaled case simulations. The preliminary scaling analysis performance was evaluated, and scaling distortions were investigated based on data magnitude, sequence, and similarity. The results indicated a necessity to change the normalization method for thermal storage generating optimal operating conditions of 261 kW power and mass flow rate of 6.42 kg/s and the possibility of reselecting governing laws for hydrogen electrolysis to improve scaling predictive properties. To enhance system-scaling similarity for TEDS and HTSE, the requirement for scaling validation via physical-facility demonstration was identified.

08 HYDROGEN↗

Physical Properties of Moist, Fermented Corn Kernels

A novel approach to producing corn stover biomass feedstock has been investigated. In this approach, corn grain and stover are co-harvested at moisture contents much less than typical corn silage. The grain and stover are conserved together by anaerobic storage and fermentation and then separated before end use. When separated from the stover, the moist, fermented grain had physical characteristics that differ from typical low-moisture, unfermented grain. A comprehensive study was conducted to quantify the physical properties of this moist, fermented grain. Six corn kernel treatments, either fermented or unfermented, having different moisture contents, were used. Moist, fermented kernels (26 and 36% w.b. moisture content) increased in size during storage. The fermented kernels’ widths and thicknesses were 10% and 15% greater, respectively, and their volume was 28% greater than the dry kernels (15% w.b.). Dry basis particle density was 9% less for moist, fermented kernels. Additionally, the dry basis bulk density was 29% less, and the dry basis hopper-discharged mass flow rate was 36% less. Moist, fermented grain had significantly greater kernel-to-kernel coefficients of friction and angles of repose compared to relatively dry grain. The friction coefficient on four different surfaces was also significantly greater for fermented kernels. Fermented corn kernels had lower individual kernel rupture strengths than unfermented kernels. These physical differences must be considered when designing material handling and processing systems for moist, fermented corn grain.

09 BIOMASS FUELS↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automation of Nanoparticle Synthesis Processes in a Plasma Environment Using LabVIEW

This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.

PECVD↗

Sensitivity and Uncertainty Quantification of Transition Scenario Simulations

This report documents the first collective attempt at developing and applying capabilities to quantify uncertainties, assess parametric sensitivities, and optimize multiple parameters and metrics in fuel cycle simulations generated by the SA&I Campaign. To do this, external codes that were designed to perform sensitivity analysis and uncertainty quantification (SA&UQ) needed to be coupled to the SA&I Campaign’s nuclear fuel cycle simulators (NFCS). In FY20, two approaches were pursued: 1) coupling Cyclus to an ORNL-internal code called MOT (Metaheuristic Optimization Tool) and 2) coupling DYMOND to the opensource SA&UQ tool kit Dakota. The primary objective of having these NFCS/SA&UQ coupled capabilities is to better inform DOE-NE and other stakeholders on the results generated from the NFCS. For a given set of fuel cycle strategies, policies, and technology assumptions that make up a fuel cycle scenario, these NFCS have traditionally been used by the SA&I Campaign to provide quantitative answers in terms of year-by-year mass flows, infrastructure requirements, costs, etc. With these newly developed coupled capabilities, the SA&I Campaign can now efficiently simulate hundreds or thousands of these scenarios, sample large ranges of parameters and assumptions, and use the unique features of the SA&UQ tools to process the data. This enables providing answers with known and propagated uncertainties, determining the sensitivity of important metrics to different parameters and assumptions, quantifying how much fuel cycle and technology parameters impact each other, and producing optimized fuel cycle strategies for single and multiple variables. To demonstrate these new capabilities, the Cyclus/MOT was used to model several scenarios ranging from simple fleet retirements to transitions to advanced reactors. Specifically, for a transition scenario from LWRs to SFRs and advanced LWRs, uncertainty quantification, sensitivity analysis, and optimization studies were applied to cases involving single and multiple parameter (input) and single and multiple metric (output) variations. In addition, a similar transition scenario was modeled to demonstrate how to optimize the reprocessing capacity parameter to minimize two performance metrics while taking into account uncertainties from two other parameters. Lastly, a depletion module based on SCALE/ORIGEN was added in Cyclus to simulate the third scenario that was designed to quantify the impact of the modeling assumption that all LWR used nuclear fuel have the same burnup. The newly developed DYMOND/Dakota capability was also applied to a transition scenario from the existing fleet to small modular reactors and fast reactors. This particular scenario involves not only explicit isotopic depletion via ORIGEN-2, but also includes multirecycling and utilizing the criticality search feature to determine the fresh fuel composition of recycled fuel, a feature unique to the DYMOND NFCS. A large database of simulations were run with 4 main parameters that were sampled: start date of reprocessing, reprocessing capacity, energy demand growth rate, and advanced reactor share of the fleet. The 4 main metrics were uranium consumption, enrichment requirements, waste generation, and levelized cost of electricity using data from the Cost Basis Report. The demonstrated SA&UQ results include those that inform on how to choose parameters to avoid “failed” scenarios, Sobol’ indices that inform on the importance of various parameters individually and synergistically, and Analysis of Variance (ANOVA) studies that decompose parameter ranges into groups and informs on whether variations are statistically significant.

Feng, B.↗

Using Machine Learning to Predict Future Temperature Outputs in Geothermal Systems

Optimizing the power output, and economic value, of geothermal power plants over decades of operation is a major challenge in renewable energy. Optimizing the output requires the ability to predict the mass flow rates and the output temperatures of production wells based on the inputs of injection wells, as well as the time history of the system. Machine Learning (ML) that incorporates the known physics of geothermal systems is one possible solution to this challenge. In this work, we explore the ability of ML algorithms to predict future temperature outputs based on historical data. Considering the challenges with obtaining an empirical dataset from field data that is large enough to enable reliable ML, we propose an alternate approach: developing a high-fidelity reservoir model and using computational resources to build a dataset that enables ML. As a first step towards achieving this goal, we present preliminary results from applying ML to predict the temperature timeseries of simple modeled geothermal systems. We describe the application of relevant state-of-the-art ML approaches, such as the Long Short-Term Memory (LSTM) networks and Convolutional Neural Networks (CNN), to extract temporal structures in the model data. We assess the accuracy of the forecasts we obtain, compare the selected approaches, and share the lessons learned that would inform the process of training and utilizing ML algorithms for larger and more complex geothermal systems.

GEOTHERMAL ENERGY↗

Performance Analysis of a Membrane-based Ionic Liquid Desiccant (ILD) Dehumidifier

Air dehumidification through cooling is an energy-intensive process, which consumes about 20-40% of the overall energy for air-conditioning. Liquid desiccant dehumidification can separate dehumidification from space cooling and has potential to improve the cooling efficiency and reduce the overall energy consumption for air-conditioning. However, the drawbacks such as liquid carryover and corrosion, membrane contamination and blocking, limit its application. To eliminate these problems, a new dehumidifier using nonporous membrane and ionic liquid desiccant (ILD) was developed. The dehumidification performance of the new dehumidifier was characterized through a series of lab tests. Test results indicate that the new dehumidifier can achieve a moisture removal rate up to 180.3 g/h and a dehumidification effectiveness up to 12.7%. A parametric study found that the dehumidification performance is sensitive to the flowrates of the air and the ILD solution. A higher mass flow ratio between the ILD solution and the air could result in better dehumidification performance.

Wang, Lingshi↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

GOOML: Geothermal Operational Optimization with Machine Learning

Geothermal Operational Optimization with Machine Learning (GOOML) is a project focused on maximizing increased availability and capacity from existing industrial-scale geothermal generation assets. The GOOML project will develop a suite of machine learning-based algorithms that analyze historical production datasets and provide predictive setpoints for geothermal field operations. Historical datasets from New Zealand and the US will provide the input to develop digital geothermal system twins which allow prediction of market conditions, maintenance operations and steamfield optimization. The algorithms will identify key parameters within fields and suggest setpoints for components of the system to maintain optimal generation. Set-points can be instructed to follow mass flow restrictions, generation maximization and optimal field/reservoir balance and give field operators a guide by which generation can be optimized. The datasets that will be used to develop GOOML are sourced from operating geothermal fields in New Zealand and the United States with varying degrees of complexity. This will ensure that most geothermal systems can utilize the GOOML tool to assist in optimizing operations. GOOML aims to achieve a step-change in geothermal operations by developing state-of-the-art machine learning algorithms, comprehensive data analytics, and a first-of-its-kind automated, intelligent geothermal system model.

algorithms↗