Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Novel Approach to Simulating Diagnostic Capabilities in Medical Resource Risk Assessment

Diagnostics represent a key subset of medical resources considered for helping mitigate and control spaceflight medical risk. Historically, when modeling the medical risk domain for spaceflight, diagnostic resources have been handled like any other medical resource used for treatment. That is to say, the resource being unavailable will result in the related condition having suboptimal treatment outcomes. However in the real world, should a diagnostic resource be unavailable, a more analogous effect would be that the condition might be misdiagnosed, and thus inappropriate treatment applied. This talk presents an alternative means of representing diagnostic resources within the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT) that can simulate the effect both in risk, resource consumption, and competition for resources of a missing or depleted diagnostic. The scenario where a differential diagnosis may not be possible for abdominal conditions that use an ultrasound machine as a diagnostic tool is considered. Two approaches for modeling the effect of not having a diagnostic capability on the medical system are demonstrated. In the “simple” approach, it is assumed that any abdominal condition requiring the ultrasound machine for diagnosis is mis-diagnosed and treated as an appendicitis. This is represented by replacing the treatment for the affected conditions with the treatment for appendicitis, thereby changing the optimized medical set available for treatment for the remainder of the mission. In the “complex” approach, MEDPRAT treatment clusters are utilized to capture and represent overlapping treatment between the misdiagnosed condition and appendicitis. This elicits both the effect that inappropriate treatment is applied, resulting in wasted resource consumption, and that treatment which was truly needed for the misdiagnosed condition was not applied, which reduces the treatment effectiveness. In this talk, results comparing the simple and complex diagnostic capability approach to a baseline where the diagnostic is treated as a traditional resource is presented. Either approach provides an option for a more analogous representation of diagnostic resources and provides insight into how the modeled spaceflight medical resources and outcomes change when that diagnostic is unavailable.

C. M. Gasiewski↗

Exploration Atmosphere Demonstration of A Multi-Functional Integrated Medical Device (Tempus Pro)

INTRODUCTION The Exploration Medical Capability (ExMC) element within the Human Research Program and the Exploration Medical Integrated Product Team (XMIPT) within the Mars Campaign Office seek to advance medical system design and risk-informed decision-making for exploration missions. This includes assessment of candidate devices and their compatibility within a variety of increasingly Earth-independent medical scenarios. The Tempus Pro (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf (COTS), multi-functional integrated medical device capable of vital signs monitoring, with built-in procedure support (iAssist), patient record and telemedicine communication features, and medical imaging (e.g., camera, laryngoscope, ultrasound) that meets multiple exploration medical capability needs. One of several hypobaric atmospheres being considered for exploration vehicles is 8.2 psi with 34% oxygen. To assess the useability of the Tempus Pro in such environments by individuals without formal medical training, the unit was tested in May and June of 2023 at the Johnson Space Center 20-Foot Exploration Atmosphere Chamber in conjunction with the Exploration Atmospheres-2 (EA-2) study. TECHNOLOGY DEMONSTRATION Eight subjects in the EA-2 study were assigned roles as the caregiver or patient – or both in the case of a self-exam – and caregivers were asked to place sensors for 3-Lead ECG, non-invasive blood pressure (NIBP), pulse oximetry (SpO2), and temperature using Tempus Pro’s iAssist. Depending on the procedure, additional tasks included an oropharyngeal exam of the throat with the laryngoscope and capturing ultrasound images of a cardiac subxiphoid view or of the user’s choice from a pre-specified list. Scenarios ranged from remote-guided to fully autonomous operations and surveyed the effectiveness of support, amount of support desired, and importance of support by type (e.g., written crew procedures, iAssist and device guidance, remote console guidance, etc.). Feedback from the subjects and the support personnel was also gathered to inform future designs for training and support and to determine what operations are plausible given different levels of each. An unweighted NASA task load index (TLX) was used to profile the demands of using the device, however the sample size does not support statistics. The research was exploratory in nature and qualitative information was the main goal. Calibration checks on the Tempus Pro were conducted before and after chamber testing to ensure the device was in useable condition. RESULTS All subjects performed their tasks successfully and found the Tempus Pro easy to use with the support provided. The calibration checks outside the chamber showed that the Tempus Pro remained unchanged and measurements inside the chamber were within normal values. Caregivers taking the NASA TLX reported mean scores ≤ 41/100 showing the tasks to be undemanding and less demanding with repeated use (~20/100). Novice users were able to easily connect sensors and take vital signs with the guidance from Tempus Pro’s iAssist feature. For more complex tasks, such as the oropharyngeal exam and ultrasound image acquisition, guidance beyond iAssist was needed, primarily from a supporting physician. Feedback on the importance of support types varied by person and scenario but greater than 50% of the support used by each was non-native to the device. Overall opinions were positive, but the ultrasound users expressed a lack of confidence in their results and 3 out of 4 desired more time, training, or support. Subjects found the sensors to be comfortable and comparable to prior experiences with such devices, except for the blood pressure cuff, which squeezed too tightly for uncomfortably long periods. Many observations provoked discussion, especially regarding ultrasound, that will aide decisions about future demonstrations.

R. S. Miller↗

RECONSTRUCTION OF INDIVIDUAL DOSES DUE TO MEDICAL EXPOSURES FOR MEMBERS OF THE TECHA RIVER COHORT

Purpose: To describe a methodology for reconstruction of doses due to medical exposures for members of the Techa River Cohort (TRC) who received diagnostic radiation at the clinic of the Urals Research Center for Radiation Medicine (URCRM) in 1952–2005. To calculate doses of medical exposure for the TRC members and compare with the doses that resulted from radioactive contamination of the Techa River. Material and Methods: Reconstruction of individual medical doses is based on data on x-ray diagnostic procedures available for each person examined at the URCRM clinics and values of absorbed dose in 12 organs per typical x-ray procedure calculated with the use of a mathematical phantom. Personal data on x-ray diagnostic examinations have been complied in the computerized “Registry of x-ray diagnostic procedures.” Sources of information are archival registry books from the URCRM x-ray room (available since 1956) and records on x-ray diagnostic procedures in patient-case histories (since 1952). The absorbed doses for 12 organs of interest have been evaluated per unit typical x-ray procedure with account taken of the x-ray examination parameters characteristic for the diagnostic machines used at the URCRM clinics. These parameters have been evaluated from published data on technical characteristics of the x-ray diagnostic machines used at the URCRM clinics in 1952–1988 and taken from the x-ray room for machines used at the URCRM in 1989–2005. Absorbed doses in the 12 organs per unit typical x-ray procedure have been calculated with use of a special computer code, EDEREX, developed at the Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev. Individual accumulated doses of medical exposure have been calculated with a computer code, MEDS (Medical Exposure Dosimetry System), specifically developed at the URCRM. Results: At present, the “Registry of x-ray diagnostic procedures” contains information on individual x-ray examinations for over 9,500 persons including 6,415 TRC members. Statistical analysis of the Registry data showed that the more frequent types of examinations were fluoroscopy and radiography of the chest and fluoroscopy of the stomach and the esophagus. Average absorbed doses accumulated by year 2005 calculated for the 12 organs varied from 4 mGy for testes to 40 mGy for bone surfaces. Maximum individual medical doses could reach 500–650 mGy and in some cases exceeded doses from exposure at the Techa River. Conclusions: For the first time the doses of medical exposure were calculated and analyzed for members of the Techa River Cohort who received diagnostic radiation at the URCRM clinics. These results are being used in radiation-risk analysis to adjust for this source of confounding exposure in the TRC.

dose reconstruction↗

Association Between Anticholinergic Medication Use and Cognition, Brain Metabolism, and Brain Atrophy in Cognitively Normal Older Adults

Importance of this Paper: The use of anticholinergic (AC) medication is linked to cognitive impairment and an increased risk of dementia. To our knowledge, this is the first study to investigate the association between AC medication use and neuroimaging biomarkers of brain metabolism and atrophy as a proxy for understanding the underlying biology of the clinical effects of AC medications. Objective: To assess the association between AC medication use and cognition, glucose metabolism, and brain atrophy in cognitively normal older adults from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) and the Indiana Memory and Aging Study (IMAS). Design, Setting, and Participants: The ADNI and IMAS are longitudinal studies with cognitive, neuroimaging, and other data collected at regular intervals in clinical and academic research settings. For the participants in the ADNI, visits are repeated 3, 6, and 12 months after the baseline visit and then annually. For the participants in the IMAS, visits are repeated every 18 months after the baseline visit (402 cognitively normal older adults in the ADNI and 49 cognitively normal older adults in the IMAS were included in the present analysis). Participants were either taking (hereafter referred to as the AC + participants [52 from the ADNI and 8 from the IMAS]) or not taking (hereafter referred to as the AC - participants [350 from the ADNI and 41 from the IMAS]) at least 1 medication with medium or high AC activity. Data analysis for this study was performed in November 2015. Main Outcomes and Measures: Cognitive scores, mean fludeoxyglucose F 18 standardized uptake value ratio (participants from the ADNI only), and brain atrophy measures from structural magnetic resonance imaging were compared between AC + participants and AC - participants after adjusting for potential confounders. The total AC burden score was calculated and was related to target measures. The association of AC use and longitudinal clinical decline (mean [SD] follow-up period, 32.1 [24.7] months [range, 6-108 months]) was examined using Cox regression. Results: The 52 AC + participants (mean [SD] age, 73.3 [6.6] years) from the ADNI showed lower mean scores on Weschler Memory Scale–Revised Logical Memory Immediate Recall (raw mean scores: 13.27 for AC + participants and 14.16 for AC - participants; P = .04) and the Trail Making Test Part B (raw mean scores: 97.85 seconds for AC + participants and 82.61 seconds for AC - participants; P = .04) and a lower executive function composite score (raw mean scores: 0.58 for AC + participants and 0.78 for AC - participants; P = .04) than the 350 AC - participants (mean [SD] age, 73.3 [5.8] years) from the ADNI. Reduced total cortical volume and temporal lobe cortical thickness and greater lateral ventricle and inferior lateral ventricle volumes were seen in the AC + participants relative to the AC - participants. Conclusions and Relevance of this Paper: The use of AC medication was associated with increased brain atrophy and dysfunction and clinical decline. Thus and finally, use of AC medication among older adults should likely be discouraged if alternative therapies are available.

60 APPLIED LIFE SCIENCES↗

The incidence of burnout or compassion fatigue in medical dosimetrists as a function of various stress and psychologic factors

ABSTRACT: Burnout and compassion fatigue (CF) adversely affect medical professionals, including those employed in radiation oncology. Previously conducted research acknowledged the presence of burnout in populations of radiation therapists, radiation oncologists, and oncology nursing staff. The aim of the following research was to measure the incidence of burnout or CF in the specific population of medical dosimetrists surveyed. As professional members of the radiation oncology team, this group had not been included in published research data to date. The hypothesis of the subsequent study stated that a comparable incidence of burnout would be observed among medical dosimetrists as had been reported by earlier researchers for a population of radiation therapists. A survey tool based on the Maslach Burnout Inventory (MBI) and distributed to full members of the American Association of Medical Dosimetrists (AAMD) was utilized as the research measurement method. Results obtained indicated an incidence rates of burnout or CF for medical dosimetrists were less than the rates previously measured for radiation therapists (53% vs 11% for emotional exhaustion [EE] and 45% vs 27% for depersonalization [DP]). The incidence of burnout was based on the Burnout Inventory (BI) developed for the research project. Each of the subscales, EE, DP, and decreased personal accomplishment (PA), was considered and analyzed independently. Although not as prevalent among medical dosimetrists as a variety of additional radiation oncology professionals, a significant portion of the population demonstrated signs of burnout or CF. Future concerns abound for the population of medical dosimetrists as a large number of members scored positive for intermediate risk of burnout and CF. Additionally, a large portion of the population was found to be rapidly approaching retirement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-03: The Ottawa Medical Physics Institute (OMPI): A Practical Model for Academic Program Collaboration in a Multi-Centre City

Purpose: To build a world-class medical physics educational program that capitalizes on expertise distributed over several clinical, government, and academic centres. Few if any of these centres would have the critical mass to solely resource a program. Methods: In order to enable an academic program, stakeholders from five institutions made a proposal to Carleton University for a) a research network with defined membership requirements and a process for accepting new members, and b) a graduate specialization (MSc and PhD) in medical physics. Both proposals were accepted and the program has grown steadily. Our courses are taught by medical physicists from across the collaboration. Our students have access to physicists in: clinical radiotherapy (the Ottawa Cancer Centre treats 4500 new patients/y), radiology, cardiology and nuclear medicine, Canada’s primary standards dosimetry laboratory, radiobiology, and university-based medical physics research. Our graduate courses emphasize the foundational physics plus applied aspects of imaging, radiotherapy, and radiobiology. Active researchers in the city-wide volunteer-run network are appointed as adjunct professors by Physics, giving them access to national funding competitions and partial student funding through teaching assistantships while opening up facilities in their institutions for student thesis research. Results: The medical physics network has grown to ∼40 members from eight institutions and includes five full-time faculty in Physics and 17 adjunct research professors. The graduate student population is ∼20. Our graduates have proceeded to a spectrum of careers. Our alumni list includes a CCPM Past-President, the current COMP President, many clinical physicists, and the heads of at least three major clinical medical physics departments. Our PhD was Ontario’s first CAMPEP-accredited program. Conclusion: A self-governing volunteer network is the foundational element that enables an MSc/PhD medical physics program in a city with multiple physicist employers. It enriches graduate education with an unusually broad range of expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

Self-reported health behaviors, including sleep, correlate with doctor-informed medical conditions: data from the 2011 Health Related Behaviors Survey of U.S. Active Duty Military Personnel

Health behaviors and cardiometabolic disease risk factors may differ between military and civilian populations; therefore, in U.S. active duty military personnel, we assessed relationships between demographic characteristics, self-reported health behaviors, and doctor-informed medical conditions. Methods Data were self-reported by 27,034 active duty military and Coast Guard personnel who responded to the 2011 Department of Defense Health Related Behaviors Survey. Multivariate linear and logistic regressions were used to estimate cross-sectional associations between (1) demographic characteristics (age, sex, service branch, marital status, children, race/ethnicity, pay grade) and self-reported behaviors (exercise, diet, smoking, alcohol, sleep); (2) demographic characteristics and doctor-informed medical conditions (hypertension, hypercholesterolemia, low high density lipoprotein (HDL) cholesterol, hyperglycemia) and overweight/obesity; and (3) behaviors and doctor-informed medical conditions. Results Among respondents (age 29.9 ± 0.1 years, 14.7% female), females reported higher intake than men of fruit, vegetables, and dairy; those with higher education reported higher intakes of whole grains; those currently married and/or residing with children reported higher intake of starches. Older age and female sex were associated with higher odds (ORs 1.25 to 12.54 versus the youngest age group) of overweight/obesity. Older age and female sex were also associated with lower odds (ORs 0.29 to 0.65 versus male sex) of doctor-informed medical conditions, except for blood glucose, for which females had higher odds. Those currently married had higher odds of high cholesterol and overweight/obesity, and separated/divorced/widowed respondents had higher odds of high blood pressure and high cholesterol. Short sleep duration (< 5 versus 7–8 h/night) was associated with higher odds (ORs 1.36to 2.22) of any given doctor-informed medical condition. Strength training was associated with lower probability of high cholesterol, high triglycerides, and low HDL, and higher probability of overweight/obesity. Dietary factors were variably associated with doctor-informed medical conditions and overweight/obesity. Conclusions This study observed pronounced associations between health behaviors—especially sleep—and medical conditions, thus adding to evidence that sleep is a critical, potentially modifiable behavior within this population. When possible, adequate sleep should continue to be promoted as an important part of overall health and wellness throughout the military community.

60 APPLIED LIFE SCIENCES↗

STS-3 medical report

The medical operations report for STS-3, which includes a review of the health of the crew before, during, and immediately after the third Shuttle orbital flight is presented. Areas reviewed include: health evaluation, medical debriefing of crewmembers, health stabilization program, medical training, medical 'kit' carried in flight, tests and countermeasures for space motion sickness, cardiovascular profile, biochemistry and endocrinology results, hematology and immunology analyses, medical microbiology, food and nutrition, potable water, shuttle toxicology, radiological health, and cabin acoustic noise. Environmental effects of shuttle launch and landing medical information management, and management, planning, and implementation of the medical program are also dicussed.

Pool, S. L.↗

Shuttle abort landing site emergency medical services

NASA and DOD studies of medical-planning and logistical problems are reviewed as applicable to providing emergency medical care at remote transoceanic abort landing (TAL) sites. Two options are analyzed including a modified surgical response team and a combination physician/medical technician team. The two concepts are examined in terms of cost-effectiveness, specific types of medical support such as blood procurement, and search-and-rescue requirements. It is found that the physician/technician team is more economically efficient, and the description of the concept permits the development of an effective TAL-site astronaut medical-support system. A balance is struck between the competing problems of cost and medical capability by planning for on-scene medical stabilization and air evacuation to DOD tertiary medical centers.

Mckenas, David K.↗

Linking medical records to an expert system

This presentation will be done using the IMR-Entry (Intelligent Medical Record Entry) system. IMR-Entry is a software program developed as a front-end to our diagnostic consultant software MEDAS (Medical Emergency Decision Assistance System). MEDAS (the Medical Emergency Diagnostic Assistance System) is a diagnostic consultant system using a multimembership Bayesian design for its inference engine and relational database technology for its knowledge base maintenance. Research on MEDAS began at the University of Southern California and the Institute of Critical Care in the mid 1970's with support from NASA and NSF. The MEDAS project moved to Chicago in 1982; its current progress is due to collaboration between Illinois Institute of Technology, The Chicago Medical School, Lake Forest College and NASA at KSC. Since the purpose of an expert system is to derive a hypothesis, its communication vocabulary is limited to features used by its knowledge base. The development of a comprehensive problem based medical record entry system which could handshake with an expert system while creating an electronic medical record at the same time was studied. IMR-E is a computer based patient record that serves as a front end to the expert system MEDAS. IMR-E is a graphically oriented comprehensive medical record. The programs major components are demonstrated.

Naeymi-Rad, Frank↗

A prototype Crew Medical Restraint System (CMRS) for Space Station Freedom

The Crew Medical Restrain System (CMRS) is a prototype system designed and developed for use as a universally deployable medical restraint/workstation on Space Station Freedom (SSF), the Shuttle Transportation System (STS), and the Assured Crew Rescue Vehicle (ACRV) for support of an ill or injured crewmember requiring stabilization and transportation to Earth. The CMRS will support all medical capabilities of the Health Maintenance Facility (HMF) by providing a restraint/interface system for all equipment (advance life support packs, defibrillator, ventilator, portable oxygen supply, IV pump, transport monitor, transport aspirator, and intervenous fluids delivery system) and personnel (patient and crew medical officers). It must be functional within the STS, ACRV, and all SSF habitable volumes. The CMRS will allow for medical capabilities within CPR, ACLS and ATLS standards of care. This must all be accomplished for a worst case transport time scenario of 24 hours from SSF to a definitive medical care facility on Earth. A presentation of the above design prototype with its subsequent one year SSF/HMF and STS/ACRV high fidelity mock-up ground based simulation testing will be given. Also, parabolic flight and underwater Weightless Test Facility evaluations will be demonstrated for various medical contingencies. The final design configuration to date will be discussed with future space program impact considerations.

Johnston, S. L.↗

Apparatus for detecting at least one predetermined condition and providing an informational signal in response thereto in a medication infusion system

A medication infusion system provides redundant safety and includes condition detecting and informational alarm signal generating apparatus for indicating if (1) a fluid leak occurs in different portions of the system; (2) a programmable input from a patient or physician would result in exceeding a safe dosage limit; (3) the reservoir containing medication has been filled; (4) the intended medication pumping does not correlate with the pumping actually effected; (5) battery voltage is low; (6) the medication reserve is low; and (7) the system has been switched off. The apparatus may provide subcutaneous electrical, thermal, or audible stimulation to the patient and also provides a signal which a physician may monitor. The stimulation may be coded to separately identify each above-listed deviation in nominal system performance. In addition, the number of medication requests are correlated with actual medication dispensing to assure proper operation. An identification scheme is provided which matches the patient with his or her corresponding medication.

Fischell, Robert E.↗

Medical Operations Console Procedure Evaluation: BME Response to Crew Call Down for an Emergency

International Space Station (ISS) Mission Operations are managed by multiple flight control disciplines located at the lead Mission Control Center (MCC) at NASA-Johnson Space Center (JSC). ISS Medical Operations are supported by the complementary roles of Flight Surgeons (Surgeon) and Biomedical Engineer (BME) flight controllers. The Surgeon, a board certified physician, oversees all medical concerns of the crew and the BME provides operational and engineering support for Medical Operations Crew Health Care System. ISS Medical Operations is currently addressing the coordinated response to a crew call down for an emergent medical event, in particular when the BME is the only Medical Operations representative in MCC. In this case, the console procedure BME Response to Crew Call Down for an Emergency will be used. The procedure instructs the BME to contact a Surgeon as soon as possible, coordinate with other flight disciplines to establish a Private Medical Conference (PMC) for the crew and Surgeon, gather information from the crew if time permits, and provide Surgeon with pertinent console resources. It is paramount that this procedure is clearly written and easily navigated to assist the BME to respond consistently and efficiently. A total of five BME flight controllers participated in the study. Each BME participant sat in a simulated MCC environment at a console configured with resources specific to the BME MCC console and was presented with two scripted emergency call downs from an ISS crew member. Each participant used the procedure while interacting with analog MCC disciplines to respond to the crew call down. Audio and video recordings of the simulations were analyzed and each BME participant's actions were compared to the procedure. Structured debriefs were conducted at the conclusion of both simulations. The procedure was evaluated for its ability to elicit consistent responses from each BME participant. Trials were examined for deviations in procedure task completion and/or navigation, in particular the execution of the Surgeon call sequence. Debrief comments were used to analyze unclear procedural steps and to discern any discrepancies between the procedure and generally accepted BME actions. The sequence followed by BME participants differed considerably from the sequence intended by the procedure. Common deviations included the call sequence used to contact Surgeon, the content of BME and crew interaction and the gathering of pertinent console resources. Differing perceptions of task priority and imprecise language seem to have caused multiple deviations from the procedure s intended sequence. The study generated 40 recommendations for the procedure, of which 34 are being implemented. These recommendations address improving the clarity of the instructions, identifying training considerations, expediting Surgeon contact, improving cues for anticipated flight control team communication and identifying missing console tools.

Johnson-Troop↗

Exploration Medical Capability

Exploration Medical Capability (ExMC) is an element of NASA's Human Research Program (HRP). ExMC's goal is to address the risk of the Inability to Adequately Recognize or Treat an Ill or Injured Crewmember. This poster highlights the approach ExMC has taken to address this goal and our current areas of interest. The Space Medicine Exploration Medical Condition List (SMEMCL) was created to identify medical conditions of concern during exploration missions. The list was derived from space flight medical incidents, the shuttle medical checklist, the International Space Station medical checklist, and expert opinion. The conditions on the list were prioritized according to mission type by a panel comprised of flight surgeons, physician astronauts, engineers, and scientists. From the prioritized list, the ExMC element determined the capabilities needed to address the medical conditions of concern. Where such capabilities were not currently available, a gap was identified. The element s research plan outlines these gaps and the tasks identified to achieve the desired capabilities for exploration missions. This poster is being presented to inform the audience of the gaps and tasks being investigated by ExMC and to encourage discussions of shared interests and possible future collaborations.

Watkins, Sharmila↗

Integrated Medical Model (IMM) 4.0 Enhanced Functionalities

The Integrated Medical Model is a probabilistic simulation model that uses input data on 100 medical conditions to simulate expected medical events, the resources required to treat, and the resulting impact to the mission for specific crew and mission characteristics. The newest development version of IMM, IMM v4.0, adds capabilities that remove some of the conservative assumptions that underlie the current operational version, IMM v3. While IMM v3 provides the framework to simulate whether a medical event occurred, IMMv4 also simulates when the event occurred during a mission timeline. This allows for more accurate estimation of mission time lost and resource utilization. In addition to the mission timeline, IMMv4.0 features two enhancements that address IMM v3 assumptions regarding medical event treatment. Medical events in IMMv3 are assigned the untreated outcome if any resource required to treat the event was unavailable. IMMv4 allows for partially treated outcomes that are proportional to the amount of required resources available, thus removing the dichotomous treatment assumption. An additional capability IMMv4 is to use an alternative medical resource when the primary resource assigned to the condition is depleted, more accurately reflecting the real-world system. The additional capabilities defining IMM v4.0the mission timeline, partial treatment, and alternate drug result in more realistic predicted mission outcomes. The primary model outcomes of IMM v4.0 for the ISS6 mission, including mission time lost, probability of evacuation, and probability of loss of crew life, are be compared to those produced by the current operational version of IMM to showcase enhanced prediction capabilities.

Spae Adaptation Syndrome↗

The First Government Sanctioned Delivery of Medical Supplies by Remotely Controlled Unmanned Aerial System (UAS)

The first government sanctioned delivery of medical supplies by UAS occurred at Wise, Virginia, on July 17, 2015. The "Let's Fly Wisely" event was a demonstration of the humanitarian use of UAS to facilitate delivery of medical supplies to remote or otherwise difficult-to-reach areas. The event was the result of coordinated efforts by a partnership which included the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), Virginia Polytechnic Institute, the Mid-Atlantic Aviation Partnership (MAAP), Flirtey Corporation, Lonesome Pine Airport, Remote Area Medical (RAM), Health Wagon, SEESPAN Aerial Interactive, Rx Partnership, and Wise County, Virginia. The historic event occurred during the annual Remote Area Medical clinic at the Wise County Fairgrounds. The medical supplies in small packages were delivered to the Wise County Fairgrounds from the Lonesome Pine Airport by UAS operated by Firtey. A larger supply of medical supplies were delivered to the Lonesome Pine Airport from the Tazewell County Airport by NASA Langley's SR22 UAS Surrogate Research aircraft. The UAS Surrogate aircraft was remotely controlled for most of the flight by a UAS Ground Control Station located at the Lonesome Pine Airport. The medical supplies were delivered from the UAS Surrogate to Flirtey for final delivery by Hex Multi-Rotor UAS in smaller packages and multiple trips to the fairgrounds. A Certificate of Authorization (COA) issued by the Federal Aviation Administration (FAA) designated the site as an authorized UAS test site. The paper will present additional details of the historic delivery of pharmaceuticals by UAS during the "Let's Fly Wisely" event. The paper will also provide details of NASA's SR22 UAS Surrogate Research aircraft. The UAS Surrogate was designed to investigate the procedures, aircraft sensors and other systems that may be required to allow Unmanned Aerial Systems (UAS) to safely operate with manned aircraft in the National Airspace System (NAS).

Howell, Charles T., III↗