Search NASA⌕ Search

SEARCH · Search NASA

Results for “MOSFET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.

36 MATERIALS SCIENCE↗

Comparing the State-of-the-Art SiC MOSFETs: Test results reveal characteristics of four major manufacturers? 900-V and 1.2-kV SiC devices

For decades, silicon (Si)-based semiconductors were the solution for power electronics applications due to their mature technology and low manufacturing costs. However, such semiconductors seem to be approaching their limits of operation in terms of blocking voltage, working temperature, and switching speed. The voltage rating of commercial Si insulated-gate bipolar transistors (IGBTs) is limited to 6.5 kV, and at higher voltages, the maximum switching frequency featured by these semiconductors is no more than several hundred hertz. Here, the development of optimal switching schemes, such as selective harmonics elimination and selective harmonics mitigation, was mainly due to the limitation in switching performance of Si-based semiconductors for high-power converters. Moreover, no Si-based semiconductor is reported to be capable of operating beyond 200?C.

42 ENGINEERING↗

Evaluation of an implantable MOSFET dosimeter designed for use with hypofractionated external beam treatments and its applications for breast and prostate treatments

Purpose: An implantable metal-oxide semiconductor field effect transistors-based dosimeter has recently been developed for the in vivo monitoring of hypofractionated radiotherapy. This DVS-HFT dosimeter is designed for fraction sizes of 340-950 cGy and can also be used for bis in die fraction monitoring. The current work reports on the testing and evaluation of this dosimeter, including both its basic characteristics as well as its performance during simulated clinical treatment plans. Methods: The authors tested the dose rate dependence of this dosimeter (300 MU/min versus 600 MU/min), the treatment time dependence (4 min per treatment versus up to 60 min per treatment), and the dose and energy dependence (6 and 18 MV irradiations of 700-900 cGy per fraction). Additionally, they irradiated the detectors in-phantom with breast and prostate hypofractionated treatments. Results: The detectors showed no significant dose rate, treatment time, energy, or dose dependence. Furthermore, the detectors were found to perform within manufacturer tolerances for all hypofractionated treatments examined, accurately reporting the measured dose (average disagreement of - 0.65%). Conclusions: These dosimeters appear well suited for in vivo monitoring of hypofractionated radiotherapy doses, and thereby, have the potential to improve patient care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compendium of Single Event Failures in Power MOSFETs

This compendium of SEGR and SEB data organizes results from several laboratories comparing failure thresholds for several different manufacturers and technologies. The results of this compendium are aimed at the designer to show the possible variations between manufacturers and processes.

Single Event Failures MOSFETs SEGR SEB↗

Inclusion of Radiation Environment Variability for Reliability Estimates for SiC Power MOSFETs

Variability of the solar energetic particle environment is investigated for single-event-burnout reliability of silicon-carbide power metal-oxide-semiconductor field effect transistors. A probabilistic assessment of failure evaluates the benefits of de-rating voltage, shielding, and mission length. The Prediction of Solar particle Yields for Characterizing Integrating Circuits code is used to calculate a cumulative density function for the fluence of the environment. The lethal ion method is then used to determine what proportion of the environment will cause single-event-burnout. The operating voltage determines the lowest linear-energy-transfer particle that will cause single-event-burnout and that should be included in the environment distribution. The shielding and mission length also determine the final environment distribution of the mission fluence. Through calculating the reliability for different operating voltages, shielding, and mission length for a specific device, it is shown that shielding thickness and operating voltage have a large effect on reliability and can be traded off during the design.

Heavy ion↗

Effective Schottky barrier lowering of Ni silicide/p-Si(100) using an ytterbium confinement structure for high performance n-type MOSFETs

A simple but effective rare earth metal (RE) confinement structure is demonstrated to suppress surface accumulation of Yb generally encountered in the RE metal incorporated Ni silicide system. The confinement structure is realized by inserting a Ti diffusion barrier layer between Yb and Ni layers. Yb atoms can be constrained in a specified reaction region during silicidation as evidenced by Auger electron spectroscopy and cross-section transmission electron microscopy analysis. The RE metal confinement structure provides a complementary metal-oxide-semiconductor compatible approach for further Schottky barrier height engineering and is a promising method for future technology nodes.

36 MATERIALS SCIENCE↗

Identification of localized radiation damage in power MOSFETs using EBIC imaging

The rapidly increasing use of electronics in high-radiation environments and the continued evolution in transistor architectures and materials demand improved methods to characterize the potential damaging effects of radiation on device performance. Here, electron-beam-induced current is used to map hot-carrier transport in model metal-oxide semiconductor field-effect transistors irradiated with a 300 KeV focused He + beam as a localized line spanning across the gate and bulk Si. By correlating the damage to the electronic properties and combining these results with simulations, the contribution of spatially localized radiation damage on the device characteristics is obtained. Furthermore, this identified damage, caused by the He + beam, is attributed to localized interfacial P b centers and delocalized positive fixed-charges, as surmised from simulations. Comprehension of the long-term interaction and mobility of radiation-induced damage are key for future design of rad-hard devices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optoelectronic and structural characterization of trapezoidal defects in 4H-SiC epilayers and the effect on MOSFET reliability

To this day, trapezoidal defects are found in clusters and high counts in wafers representing the industry standard in terms of material quality being produced. This study sheds light on the nature, origin, behavior, and impact of this defect on device yield and reliability. Trapezoidal defects in 4H-SiC epitaxial layers were investigated by photoluminescence (PL) imaging, scanning electron microscopy (SEM), cathodoluminescence spectrum imaging (CLSI), SEM electron beam induced current (EBIC) imaging, and by transmission electron microscopy (TEM) observation. The bar-shaped stacking faults were identified by the PL and CL measurements with a peak emission wavelength of 420 and 450 nm. An optoelectronic behavioral study based on the recombination enhanced dislocation glide mechanism revealed how expanding dislocations and stacking faults interact with each other. Combining the luminescence and microscopy results, the nature of the stacking faults was identified as being a combination of Shockley-type and Frank-type stacking faults. The TEM analysis showed that these defects originate from the substrate and the stacking sequences of some of the faults were determined as (…2, 4, 2…) and (…2, 3, 2…) in the Zhdanov's notation by high-resolution TEM. The origin of this defect is speculated based on our results and previous reports. The EBIC imaging showed that the high density of SFs in these towers is a strong site of carrier recombination, which presumably has an impact on the transfer characteristics of SiC devices. Furthermore, these defects have shown to impact metal oxide semiconductor field effect transistors electrical performance via an increase in the on-state resistance depending on the coverage percentage of the tower of defects in the active area of the device.

4H-SiC↗