The theory of an active magnetic regenerative refrigerator

The adiabatic temperature change with field which is limited to about 2 K/Tesla for ferromagnets near their Curie temperatures by the change of magnetization with temperature and the lattice heat capacity is discussed. Practical magnetic refrigerators operate on a regenerative cycle such as the Brayton cycle. This cycle can be executed through the use of an active magnetic regenerator, i.e., a regenerator composed of magnetic material that is cycled in an out of a magnetic field with appropriate fluid flows. The theory of these devices is predicted by solving the partial differential equations that describe fluid and the magnetic solid. The active magnetic regenerator is described along with the method of calculation. Temperature profiles for a normal regenerator and a magnetic regenerative refrigerator are shown.

Barclay, J. A.↗

Resonant Tunneling Spin Pump

The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

Ting, David Z.↗

Momentum Flux Measuring Instrument for Neutral and Charged Particle Flows

An instrument to measure the momentum flux (total pressure) of plasma and neutral particle jets onto a surface has been developed. While this instrument was developed for magnetized plasmas, the concept works for non-magnetized plasmas as well. We have measured forces as small as 10(exp -4) Newtons on a surface immersed in the plasma where small forces are due to ionic and neutral particles with kinetic energies on the order of a few eV impacting the surface. This instrument, a force sensor, uses a target plate (surface) that is immersed in the plasma and connected to one end of an alumina rod while the opposite end of the alumina rod is mechanically connected to a titanium beam on which four strain gauges are mounted. The force on the target generates torque causing strain in the beam. The resulting strain measurements can be correlated to a force on the target plate. The alumina rod electrically and thermally isolates the target plate from the strain gauge beam and allows the strain gauges to be located out of the plasma flow while also serving as a moment arm of several inches to increase the strain in the beam at the strain gauge location. These force measurements correspond directly to momentum flux and may be used with known plasma conditions to place boundaries on the kinetic energies of the plasma and neutral particles. The force measurements may also be used to infer thrust produced by a plasma propulsive device. Stainless steel, titanium, molybdenum, and aluminum flat target plates have been used. Momentum flux measurements of H2, D2, He, and Ar plasmas produced in a magnetized plasma device have been performed.

Chavers, Greg↗

Sustained arc ignition system

Circuitry for maintaining an arc or spark across a spark gap for a desired length of time is disclosed. A high voltage, direct current source is connected in series with a secondary winding of a high voltage, stepup transformer or coil and a spark gap such as a spark plug for example. The high voltage source may be on continuously or may be turned on and off by a control circuit such as a solid state switch which is, in turn, responsive to a timing device such as a set of ignition contact points or a magnetic pulse generator operating in synchronism with a spark ignition engine. The timing device also provides signals to a current switching circuit which interrupts, current flow through a primary winding of the high voltage coil at the prescribed time that a spark is desired at the spark gap.

Birchenough, A. G.↗

Study of Plasma Radiation Shielding

The Plasma Radiation Shield is an active device using free electrons, electric and magnetic fields for the purpose of shielding astronauts from energetic solar flare-produced protons. The concept of Plasma Radiation Shielding is reviewed in the light of current studies. The available evidence indicates that the concept is physically sound, but important practical questions remain in at least two areas: these have to do with establishment and control of the extremely high voltages required, and with integration of the concept into a realistic space vehicle design.

Source record↗

Partial reflection data collection and processing using a small computer

Online data collection of the amplitudes of circularly polarized radio waves, partially reflected from the D region of the earth's ionosphere, has enabled the calculation of an electron-density profile in the height region 60-90 km. A PDP 15/30 digital computer with an analog to digital converter and magnetic tape as an intermediary storage device are used. The computer configuration, the software developed, and the preliminary results are described.

Birley, M. H.↗

Compact Ion Source for Mass Spectrometers

Cyclotron-resonance device uses miniature components and permanent magnet for small size, low weight, and low cost. Gas molecules are ionized by electrons from hot filament. Magnetic field, acting with electrostatic drift field, causes ions to move in circles with a superimposed drift perpendicular to both fields, toward the exit. Compact source can be used for studying ion-molecule reactions by ion cyclotron-resonance methods in conventional mass spectrometer with either magnetic sector or quadrupole sector.

Anicich, V. G.↗

Hall-Effect Ground-Fault Interruptor

Tested ground-fault interruption circuit utilizing Hall-effect device to sense differential current in magnetic core tips and opens circuit.

Okin, L.↗

Fiber-Optic Lateral-Displacement Sensor

Proposed fiber-optic sensor monitors axial position of shaft or bearing in turbomachine. Device senses position of non-magnetic as well as magnetic material and calibrates before assembly in machine. More compact. Concept extends to measure rotational speed of shaft.

Roschak, Edmund J.↗

Germanium Resistance Thermometer For Subkelvin Temperatures

Improved germanium resistance thermometer measures temperatures as small as 0.01 K accurately. Design provides large area for electrical connections (to reduce electrical gradients and increase sensitivity to changes in temperatures) and large heat sink (to minimize resistance heating). Gold pads on top and bottom of germanium crystal distribute electrical current and flow of heat nearly uniformly across crystal. Less expensive than magnetic thermometers or superconducting quantum interference devices (SQUID's) otherwise used.

Castles, Stephen H.↗

Ultra-stable superconducting cavity maser oscillator

An ultra-stable superconducting triple cavity ruby maser oscillator (10) is obtained by providing the oscillator with a superconducting quantum interference device (SQUID) (50), which measures the magnetic field at the ruby (14) and compensates for changes by adjusting the RF pump signal amplitude (42), thereby attaining stabilities of about four orders of magnitude greater than presently attainable.

Strayer, Donald M.↗

Improved Readout Scheme for SQUID-Based Thermometry

An improved readout scheme has been proposed for high-resolution thermometers, (HRTs) based on the use of superconducting quantum interference devices (SQUIDs) to measure temperature- dependent magnetic susceptibilities. The proposed scheme would eliminate counting ambiguities that arise in the conventional scheme, while maintaining the superior magnetic-flux sensitivity of the conventional scheme. The proposed scheme is expected to be especially beneficial for HRT-based temperature control of multiplexed SQUIDbased bolometer sensor arrays. SQUID-based HRTs have become standard for measuring and controlling temperatures in the sub-nano-Kelvin temperature range in a broad range of low-temperature scientific and engineering applications. A typical SQUIDbased HRT that utilizes the conventional scheme includes a coil wound on a core made of a material that has temperature- dependent magnetic susceptibility in the temperature range of interest. The core and the coil are placed in a DC magnetic field provided either by a permanent magnet or as magnetic flux inside a superconducting outer wall. The aforementioned coil is connected to an input coil of a SQUID. Changes in temperature lead to changes in the susceptibility of the core and to changes in the magnetic flux detected by the SQUID. The SQUID readout instrumentation is capable of measuring magnetic-flux changes that correspond to temperature changes down to a noise limit .0.1 nK/Hz1/2. When the flux exceeds a few fundamental flux units, which typically corresponds to a temperature of .100 nK, the SQUID is reset. The temperature range can be greatly expanded if the reset events are carefully tracked and counted, either by a computer running appropriate software or by a dedicated piece of hardware.

Penanen, Konstantin↗

(abstract) All Epitaxial Edge-geometry SNS Devices with Doped PBCO and YBCO Normal Layers

We will present our results on tapered-edge-geometry SNS weak link fabricated from c-axis oriented base-, counterelectrode and normal layers using a variety of processing conditions. To date, we have employed a variety of different normal materials (Co-doped YBCO, Y-doped PBCO, Ca-doped PBCO). We have been examining the junction fabrication process in detail and we will present our methods. In particular, we have been examining both epitaxial and non-epitaxial milling mask overlayers and we will present a comparison of both methods. These devices behave similar to the expectations of the resisively shunted junction model and conventional SNS proximity effect models but with some differences which will be discussed. We will present the detailed systematics of our junctions including device parameters versus temperature, rf and dc magnetic response for the various processing conditions.

epitaxial doped PBCO YBCO junction fabrication mil↗

Scalar Atomic Defect-Based Solid-State Self-calibrating Magnetometer (3SM) for Space Plasma Analysis

The Earth’s magnetosphere is a system of multiple, co-located particle populations interacting via plasma waves. Things to understand are driving processes, radiation belt and ring current issues, auroral physics, internal plasma processes, and magnetosphere-ionosphere mapping issues. These plasma-physics processes enable the Earth’s magnetosphere to evolve in response to temporal changes in the solar wind and they underlie the phenomena of space weather, which impacts spacecraft systems, astronauts, radio communications, and ground based electric-power grids. The objective of 3SM is to measure magnetic field strength and to calibrate the Vector Magnetometer (VM) device to maintain absolute accuracy during a mission. The 3SM features make the instrument preferably suited not only for the traditional role of scalar magnetometers as absolute references for the calibration of the on-board vector instruments, but also for extended operational capacities, such as higher frequency scalar measurements (of potential interest for magnetosphere studies for the low frequency part of the spectrum) or autonomous scalar / vector operations. Diamond has been the solid-state platform of choice for quantum device technologies for some time, however, it suffers from difficulties such as scalability, integration, and cost. While the diamond platform is very useful for quantum technologies, further development is needed to make it viable. The material platform of choice for NASA Glenn’s Quantum Sensing And Spin Physics (Q-SASP) is silicon carbide (SiC). This is due to the much higher industry development of the SiC material platform for high-power and high-temperature electronics. It leverages both the decades-long SiC development expertise and infrastructure at NASA Glenn and its growing capabilities in quantum metrology. To make SiC devices usable for quantum technologies such as quantum sources, a much deeper understanding of defects is needed. Q-SASP is developing quantum metrology capabilities to evaluate the energy structure, defect formation energy, band structure augmentation, generation/recombination rates, and limits of dipole-dipole coupling in non-metal implanted SiC devices. This can be achieved by analysis of zero-field splitting, low-field resonance, and singlet-triplet mixing through various forms of Electrically Detectable Magnetic Resonance (EDMR) and Near-Zero Field Magnetic Resonance (NZFMR) spectroscopy. This work will discuss recent system developments, device developments, computational modeling, and spectroscopy results and analysis of defects created by non-metal implantations in SiC devices. The defect formation energies of V Si ,V C , V C V Si , N C V Si , N Si , N C in 4H-SiC are previously reported values in other research [2]-[3]. The defect formation energies of PSi and PC were calculated in GPAW [fig 1A]. The basic underlying mechanism of the zero-field phenomenon is the mixing of singlet and triplet states [4]-[5]. In most spin-dependent transport, two electron spins are involved, and thus one must consider each of their interactions with the field. We investigated the electronic and magnetic properties of 4H-SiC and 6H-SiC. The defect formation energy helps us determine what types of defects we are observing in the SiC EDMR experiment. They have very low formation energy (it is negative). The phosphorus substitution in 4H-SiC is a very stable defect. The band diagrams provide us with vital information about how the electronic properties of SiC (such as band gap) change as we add non-metal defects. The zero-field splitting parameters allow us to study the inflection point in the NZFMR [fig 1B]. We clearly observed zero-field splitting. We also noted that the zero-field splitting remained constant with changing bias. We aspect it zero-field splitting to remain constant while the hyperfine and exchange interaction perturbations shift under the influence of an external magnetic field. This is the essence of quantum magnetometry and self-calibration.

space plasma↗

Annular momentum-control device

Rotating ring stores momentum in mechanical system. Drag is reduced by suspending rotating part in magnetic field. Combination of composites and forroceramic materials are used, providing a strong stiff device, which is better damped than metals.

Lyman, J.↗

Microwave Driven Magnetic Plasma Accelerator Studies (CYCLOPS)

A microwave-driven cyclotron resonance plasma acceleration device was investigated using argon, krypton, xenon, and mercury as propellants. Limited ranges of propellant flow rate, input power, and magnetic field strength were used. Over-all efficiencies (including the 65% efficiency of the input polarizer) less than 10% were obtained for specific impulse values between 500 and 1500 sec. Power transfer efficiencies, however, approached 100% of the input power available in the right-hand component of the incident circularly polarized radiation. Beam diagnostics using Langmuir probes, cold gas mapping, r-f mapping and ion energy analyses were performed in conjunction with an engine operating in a pulsed mode. Measurements of transverse electron energies at the position of cyclotron resonant absorption yielded energy values more than an order of magnitude lower than anticipated. The measured electron energies were, however, consistent with the low values of average ion energy measured by retarding potential techniques. The low values of average ion energy were also consistent with the measured thrust values. It is hypothesized that ionization and radiation limit the electron kinetic energy to low-values thus limiting the energy which is finally transferred to the ion. Thermalization by electron-electron collision was also identified as an additional loss mechanism. The use of light alkali metals, which have relatively few low lying energy levels to excite, with the input power to mass ratio selected so as to limit the electron energies to less than the second ionization potential, is suggested. It is concluded, however, that the over-all efficiency for such propellants would be less than 40 per cent.